piece).
Ranges and measurement ranges:
NOTE 1 : the lowermost digit is fixed at 0 at
speeds of 20,000 r/min and over.
NOTE 2 : the lowermost digit is fixed at 0 when
the averaging setting is off.
7
Page 10
TM-4100/TM-4100D
Rotational speed measurement:
Ranges and measurement range
Note 1 : The lowermost digit is fixed at 0 at
speeds of 20,000r/min and over.
Note 2 : The lowermost digit is fixed at 0 when the
averaging setting is off.
(1) Rotational speed measurement
R
MODE
Rotation
speed
measurem
ent
(r/m)
Rotational
speed
measurem
ent
(r/s)
Period
Measurem
ent
(ms)
A
N
G
1
2
3
4
1
2
3
4
1
2
Contactless
measurement
AVG =
ON
30.00 to
199.99
200.0 to
1999.9
2000 to
19999
20000
to
99990
0.5000
to
1.9999
2.000 to
19.999
20.00 to
199.99
200.0 to
1600.0
0.6000
to
1.9999
2.000 to
19.999
AVG =
OFF
-
300.0 to
1999.0
2000 to
19990
20000
to
99990
-
5.000 to
19.990
20.00 to
199.90
200.0 to
1600.0
0.6000
to
1.9990
2.000 to
19.990
Contact
measurement
AVG =
ON
15.00 to
199.99
200.0 to
1999.9
2000 to
19999
--
0.2500
to
1.9999
2.000 to
19.999
20.00 to
199.99
200.0 to
333.0
--
3.000 to
19.999
AVG =
OFF
-
150.0 to
1999.0
2000 to
19990
-
2.500 to
19.990
20.00 to
199.90
200.0 to
333.0
3.000 to
19.990
8
Page 11
TM-4100/TM-4100D
20.00 to
3
199.99
200.0 to
4
1999.9
Count
Measurem
ent(count)
(Input conditions Up to rotational speed
(2)Circumferential speed measurement
MODE Range
Circumferential
measurement
(m/min)
Circumferential
measurement
(m/s)
Accuracy AVG=ON AVG=OFF
Up to 9.999
counts
10.000 counts or
more
20.000 count or
more(r/min
mode only)
Period
measurement
only
20.00 to
199.90
0 to 999999
measurement upper limit)
AVG=ON AVG=OFF
1
2
3
1
2
3
0.0250 to
±1dgt. ±10dgt.
±2dgt. ±20dgt.
±20dgt. ±100dgt.
±0.5%rdg. Is added to
above-mentioned accuracy.
20.00 to
199.909
200.0 to
-
3999.9
Contact measurement
1.500 to
19.999
20.00 to
199.99
200.0 to
1999.9
1.9999
2.000 to
19.999
20.00 to
33.30
20.00 to
19.90
200.0 to
399.0
-
15.00 to
199.90
200.0 to
1999.0
0.2500 to
1.9990
2.000 to
19.990
20.00 to
33.30
9
Page 12
TM-4100/TM-4100D
EMC
This meter was designed in accordance with EMC
Standards in force and its compatibility has been
tested in accordance with EN61326-1 (2006).
zAc / The pulse output wiring diagram:
6 Measurement Procedures and
Preparation
Precautions in Measurement of High-Rotation
Objects Detection of reflected light uses
modulated light is input for a fixed period of time
(about 0.2ms) or longer, a single pulse is detected.
For this reason, if the light pulse generated by the
passing reflective tape is less than 0.2ms
detection is not possible.
The range that can be detected with a 12mm
square target of reflective tape is indicated below.
※Radius is the distance between the center of
the rotating object and the center of the tape.
10
Page 13
TM-4100/TM-4100D
Chapter Measurement Procedures
If the reflective tape cannot be attached within this
detection range, increase the area of the reflective
tape so that the generated pulse is 0.2ms to
higher.
For measurement of 30,000r/min. or higher, uses
the following method:
11
Page 14
TM-4100/TM-4100D
For measurement of 30,000 r/min. or higher, use
the following.
Method :
Chapter Measurement Procedures
If the reflective tape cannot be attached within this
detection range, increase the area of the reflective
tape so that the generated pulse is 0.2ms to
higher.
6.1 Battery Loading:
Remove the battery cover on the back and put a
9V battery inside.
Battery replacement: When the symbol of “
appears on the LCD display, the battery should be
replaced with a new one.
The battery symbol will be displayed on the LCD,
this symbol “
” is a battery low indicator.
6.2 Power Button:
z Press “” button to power on.
z Again Press “
” button to power off.
”
12
Page 15
TM-4100/TM-4100D
6.3 Data Hold /Backlight Button:
Press the “”button, LCD display“”,
Lock reading, and then a“” lifting "lock.
>>>>
Press the “” button for more than 2 seconds
to turn on or turn off the backlight function
Backlight light turns off automatically after 30
→Minimun value (
※ This function is not available during count
measurement (the key is disabled).
lights up)
6.6 RESET/CLR Button:
Operation method :
Operation description : The current value,
maximum value, minimum value, count measured
value, and circumferential speed value are reset
to zero.
key input
14
Page 17
TM-4100/TM-4100D
Notes :
The measured value is also cleared when
switching measurement modes and changing the
averaging setting.
6.7 AVG and Ring call ON/OFF Button:
Operation method : key input
Operation description:
The current value, maximum value, minimum
value is reset to zero.
Note:
The measured value is also cleared when
switching measurement modes and changing the
averaging setting.
Push“
mode.
Press “
disable the buzzer. When the “
the LCD Display which means the buzzer is on.
” button to enable or disable AVG
” key more 2 seconds toenable or
” symbol is on
15
Page 18
TM-4100/TM-4100D
6.8 Manual Data Memory Storing
Push“” button, this meter will save the
current measured result, and REC with a number
001~200 will appear.
Manual data memory Storing: 200 data sets.Over
load Indication: “OL”.
6.9 Viewing Data Record
Press and hold “” first, and then press
” button together to enable record reading
“
function, the LCD will display “M“ ,Press “
” button to read the next or previous
“
records ,Press and hold “
then press “
” button together to disable the
” button first, and
this function.
” or
16
Page 19
TM-4100/TM-4100D
7 Setup Mode
Press and hold “” button first ,and then
press“
Press “
from set1 to set7 mode, LCD will display from set1
to set7.
Press“
Set 1: Automatic shutdown on / off setting.
Set 2: Adjust auto-shutdown time setting.
Set 3: Record time: time. Points second set.
Set 4: Screen backlight on / off setting.
Set 5: backlight Seconds and setting
Set 6: Buzzer sounds on / off setting.
Set 7: ft. and m setting.
Setting method, see the 7.1 ~7.7 paragraphs.
7.1 St1 Automatic PowerOn/off:
After entering st1 screen then click "" to
switch from "" to "" then click ""
button to confirm the action, on behalf of not
” button to enter the Setup Mode set1.
” button to change the setup function
” button to exit the setup mode.
automatically shut down. Test mode LCD screen
17
Page 20
TM-4100/TM-4100D
no longer displays "" symbol.
Will be appeared on the LCD display.
To reply to automatic shutdown feature, please
follow the steps to cancel automatic shutdown st1,
LCD screen, select the "
" button to confirm the test status LCD
screen on the "
automatic shutdown.
Press “” key to save and exit.
" symbol to restore light, for
" symbol, then click "
7.2 St2 Auto Power off Time Setting:
After entering to St2 automatic shutdown time
setting function, then the LCD screen will display
the time, st2, and symbols together to adjust
minutes.
Press "
value to adjust the duration of the auto power off
time.
" button or "" button to enter the
18
Page 21
TM-4100/TM-4100D
Setting Auto Power Off time from:15 to 99
minutes.
Press "
the setting mode.
The auto power off time default setting is 15
minutes.
" button and enter the settings from
>>>
7.3 St3 Record Interval Time Setup
Entered into the records of each storage interval
st3 time setting
By the press "
modify the time value of the duration.
Press "
" button or " " button to
" button or "" button to shift the
19
Page 22
TM-4100/TM-4100D
cursor to move from hour to minute, then to
second for the setup.
Press "
time, and from the setting mode.
7.4 St4 Screen Backlight ON / OFF
Setting Note:
After entering st4 screen then click "" to
switch from “" to " " then click "
“button to confirm the action, performed without
backlight.
To reply to st4 backlight ON, please follow the
steps to cancel without backlight unit, select the
LCD screen on the “" symbol, then click”
a backlight.
Auto Power off Time function
" button to determine the set of the
“button to confirm, on the implementation of
20
Page 23
TM-4100/TM-4100D
>>>
7.5 St5 Backlight off Time to Select the
Setting
After enteringst6screenthen click " " to
switchconverted to a5.00>> 0.30>> 1.00>> 1.30>>
2.00>> 2.30>> 3.00>> 3.30>> 4.00>> 4.30>> 5.00
cycle
>>
Select the time you wantand thenclick" "
buttonto confirm
7.6 St6 Buzzer Sound ON / OFF Note
After entering st6 screen then click "" to
switch from “" to " " then click " "
21
Page 24
button to confirm the action.
TM-4100/TM-4100D
7.7 St7 ft. / m Unit Conversion Options:
Into the ST7 screen displayed on the” "switch "
“button for the conversion unit, the screen
displays”
"Press""button to confirm the
selection unit.
Such as to be altered in accordance with the
above instructions, and then operate a return to
the original unit
>>>
22
Page 25
TM-4100/TM-4100D
8 Battery replacement
If the symbol “ ” appears on the
LCD, please replace the battery
immediately
z Turn off the instrument.
z Remove the battery cover.
z Replace the battery.
z Install the battery cover.
warring
※ Please take out the battery in case of using
adapter.
9 Safety Precaution
For cleaning the instrument use a soft dry cloth.
Never use a wet cloth, solvents or water, etc...
Operation Altitude : Up to 2000M.
Operating Environment : Indoors use.
This instrument has been designed for being used
in an environment of pollution degree 2.
23
Page 26
10 Safety Information
TM-4100/TM-4100D
In some cases, work in the vicinity of
powerful radiation sources can be a risk of
your life.
Be aware that persons with electronic
implants (e.g. cardiac pacemakers) are
subject to particular dangers in some cases.
Observe the local safety regulations of the
facility operation.
Observe the operating instructions for
equipment, which is used to generate,
conduct, or consumer electromagnetic
energy.
Be aware that secondary radiators (e.g.
reflective objects such as a metallic fence)
can cause a local amplification of the field.
Be aware that the field strength in the near
vicinity of radiators increases proportionally to
the inverse cube of the distance. This means
that enormous field strengths can result in the
immediate vicinity of small radiation sources
(e.g. leak in wave guides, inductive ovens)
Field strength measuring device can
underrate pulsed signals. Particularly with
radar signals, significant measurement errors
DANGER
24
Page 27
TM-4100/TM-4100D
can arise.
All field strength measuring devices have a
limited specified frequency range. Fields with
spectral components outside of this frequency
range are generally incorrectly evaluated and
tend to be underrated. Before using field
strength measuring devices, you should thus
be certain that all field components to be
measured lie in the specified frequency range
of the measuring device.
11 End of life
Caution :
This symbol indicates that
equipment and its accessories shall
be subject to a separate collection
and correct disposal
25
Page 28
Professional Electrical and
Environment Test & Measurement
Instruments:
Battery Capacity ,Impedance Tester,
TACHO Meter ,LED light meter ,Temperature &
Humidity meter ,Infrared Thermometer ,Sound
level meter ,Light meter ,EMF meter ,UV Light
meter ,RF mete r ,Hot wire Anemometer ,CO
meter ,Anemometer ,Lan cable tester ,CO
meter ,Solar power meter ,Radiation meter,
Clamp meter ,Multimeter ,Phase Rotation test,
Digital Insulation teste
r.
Our products of high quality are selling
well all over the world
TENMARS ELECTRONICS CO., LTD
6F, 586, RUI GUANG ROAD, NEIHU,
TAIPEI 114, TAIWAN.
E-mail : service@tenmars.com
Http : //www.tenmars.com
2