TM-201L/TM-209
1. Description
Measures light from visible luminaries equipped with
white light LED, fluorescent, metal halide, high-pressure
sodium and incandescent sources.
2. Safety Precaution
CAUTION
Take extreme care for the following
conditions while measuring
z Do not operate the meter under the environment
with explosive gas (material), combustible gas
(material) steam or filled with dust.
z In order to avoid reading incorrect data, please
replace the battery immediately when the symbol
“
” appears on the LCD.
z In order to avoid the damage caused by
contamination or static electricity, do not touch the
circuit board before you take any adequate action.
z Operating Environment: Indoors use. This
instrument has been designed for being used in an
environment of pollution degree 2.
z Operation Altitude: Up to 2000M.
z Operating Temperature & Humidity: 5 ~ ℃40, ℃
0%~ 80%RH.
z Storage Temperature & Humidity: -10 ~ ℃60, ℃
0%~ 70%RH.
zEMC: EN61326-1(2006), IEC 61000-4-2(2008, IEC
61000-4-3(2006) + (2007).
EN-1
TM-201L/TM-209
3. Preface
The flux of light received in a unit area of a certain side
being show is popularly known as illumination. In both
United Kingdom and America its unit is known as
footcandles light, but in Europe it is known as meter
candlelight.
One foot-candles light is the illumination of light that
falls on one side that lies in a distance one foot away
from a one foot-candlelight and exactly intersecting the
light. Its abbreviated form is written as 1 Fc=1 Lm/ft,
similarly, one-meter candlelight is the illumination of
light that falls on a side that lies in a distance one meter
away from a one meter candlelight and exactly
intersects the light. It is also called Lux i,e. the flux of
light being received in each sq. meter is called the
illumination of one lumen.
office buildings, restaurants, schools, library,
hospitals, photographic, many video, parking
garages, museums, art galleries, stadiums, building
security.
z Data hold.
z Maximum hold.(TM-201L)
z Maximum/Average/Minimum Hold.(TM-209)
z Zero adjustment.
z Auto power off and disable function.(TM-209)
z Auto ranging.(TM-209)
zIf a single light source is used and is regarded as
a single-point light source, the luminous intensity
of the light source can be calculated and
displayed, by setting the distance from the light
source to the measuring point.
2
)
EN-8
TM-201L/TM-209
8. Instrument Description of TM-201L
1. Display (LCD).
2. MAX HOLD.
3. Power Button: ON/OFF.
4. Lux/Fc button
5. DATA HOLD button.
6. Range button.
7. Photo detector.
8. Zero Adjustment.
EN-9
TM-201L/TM-209
9. Instrument Description of TM-209
1. Display (LCD).
2. Lux/Fc/CD button
3. MEM/READ.
4. MAX/AVG/MIN and setup
upward.
5. Power ON/OFF and disable auto power off.
6. Real time auto zero.
7. DATA HOLD and Light source select (L.S.).
8. Setup downward.
9. Photo detector.
EN-10
TM-201L/TM-209
(%)
)
zRelative Spectral (Sensitivity)
The deviation from the comparative standards for
luminosity is determined by JIS standard C 1609-1993.
Peak sensitivity wavelength: 550 nm
Typ. Ta=23℃
100
90
80
70
60
50
40
30
20
10
0
380 440 500 560 620 680 740
V(λ) *
TM-209
RELATIVE SENSITIVITY
WAVELENGTH (nm
*CIE luminous spectral luminous
EN-11
TM-201L/TM-209
10. Attention
zSet for referring the testing of source of light is
located at the right top end (0 degree) of the light
sensor ball plane.
zWhen the meter is not in use, please keep the
cap of the light sensor in its place to avoid the
photo diode from wearing out.
zWhen it is not in use for a long time, please take
the batteries away. And avoid keeping it in a
place of high temperature and humidity.
EN-12
TM-201L/TM-209
11. Recommended Levels of Illumination
Suitable levels of illuminance
(According to the JIS standard Z 9110-1979)
Offices
Illuminance (lux)Place
1500 to 750
Offices, designing, drawing rooms
750 to 300 Offices, conference rooms, computer
rooms
300 to 100 Workrooms, corridors, stairways,
restrooms
75 to 30 Indoor emergency stairways
Factories
Illuminance (lux)Place
3000 to 1500
Where such work as assembling,
inspecting testing, selecting,
extremely precision visual work
1500 to 750 Assembling, inspecting, testing,
selecting, precision visual work
750 to 300 Assembling, inspecting, testing,
selecting and visual ordinary work
300 to 150 Wrapping and packing
75 to 30 Indoor emergency stairways
EN-13
Schools
Illuminance(lux)Place
TM-201L/TM-209
1500 to 300
Precision drawing or drafting,
precision experimenting, library
750 to 200 Classrooms, library reading rooms,
staff rooms, gymnasia
300 to 75 Lecture halls, assembly rooms,
locker rooms, corridors, stairways
and restrooms
75 to 30 Warehouses and emergency
stairways
10 to 2 School passages
EN-14
12. Battery Replacement
WARNING
TM-201L/TM-209
If the symbol ”
please replace the battery immediately
1. Remove the battery cover
2. Replace the battery.
3. Install the battery cover.
13. END OF LIFE
Caution: this symbol indicates that
equipment and its accessories shall be
subject to a separate collection and
correct disposal
”
appears on the LCD,
EN-15
TM-201L/TM-209
EN-16
TM-201L/TM-209
TENMARS ELECTRONICS CO., LTD
6F, 586, RUI GUANG ROAD, NEIHU,
E-mail: service@tenmars.com
http://www.tenmars.com
TAIPEI 114, TAIWAN.
EN-17
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.