Tenmars ST-109R User Manual

Page 1
ST-109R
Integrating Sound Level Meter
User’s Manual
HB2ST109R001
Page 2
Contents
1 Introduction ....................................................... 1
2 Accessories ....................................................... 1
3 Safety Precaution .............................................. 1
4 Instrument Description ...................................... 2
5 Operation .......................................................... 3
5.1 Backlight Button ......................................... 4
5.2 Start/Pause Measuring ............................... 4
5.3 Data Hold: .................................................. 4
5.4 Single Record/ Datalogger Reading ........... 4
5.5 Product Setup ............................................ 5
5.6 Integrating Time Setup ............................... 5
5.7 Auto Power Off ........................................... 5
5.8 Analog/Communication Output Interface .... 6
5.9 Record Data Delete/Back-up ...................... 6
5.10 94dB Calibrate ........................................... 7
5.11 Microphone Connection Inter-face .............. 7
5.12 Microphone Extension Test ........................ 8
5.13 Sensitivity Correction .................................. 9
6 Software Installation ................................ ........ 10
7 General Specifications .................................... 11
8 Electrical specification ..................................... 12
9 Maintenance or Repair .................................... 14
10 Battery Replacement ....................................... 14
11 Product Disposal ............................................. 14
Page 3
Page 4
ST-109R
- 1 -
1
1 Introduction
This Integrating Sound Level Meter (ISLM) is
IEC61672-2002 Class 1 compliant.
2 Accessories
1
Meter
1
User’s Manual
1
AC to DC adaptor
1
Windscreen ball
1
Installation disk
1
USB cable (Mini B type)
1
AC adapter (9~12V/500mA)
4
1.5V AA-LR6-AM3 alkaline battery
3 Safety Precaution
Caution! Please refer to this manual. Improper use may damage the meter ad its components.
Complies with European Directive.
Do not operate in environments with flammable
gas or humid environments.
Operating altitude: up to 2000M. Operating environment: Indoor use; Pollution
degree 2.
Clean with soft cloth when dirty, such as glasses
cloth. Do not clean with chemicals and other solvents.
EMC: EN61326-1:CISPR 11:Group 1, Class B
Class B – Equipment for use in all establishments
other than domestic.
Group1 – RF energy generated is needed for
internal functioning.
Page 5
ST-109R
- 2 -
2
4 Instrument Description
1. Microphone
2. Power Button
3. Backlight Button
4. Start or Pause Test Button
5. Frequency Weighting
Select Button
6. Time Weighting Select
Button
7. Set Button
8. Test function select
button
9. Record dada / Reading
Record dada button
10. Data Hold/ up arrow
button.
11. Clock switch/left arrow button
12. OK button
13. Clock switch/right arrow button
14. Shift switch/end
measurement/down arrow button
15. MICRO SD card slot
16. Analog/RS232 professional output
17. USB
18. DC voltage input
(6V~12V)
Page 6
ST-109R
- 3 -
3
5 Operation
1. Press button to power on or off your product.
2. Press button to selection measurement mode.
Sound pressure level (SPL) Equivalent Energy Sound Level (Leq) Sound exposure level (SEL) Peak sound pressure (PeakMAX)
3. Press button to switch time weight.
4. Press button to switch frequency weight.
5. Press button to switch shift, end integrating
measurement during integrating.
6. Press button to start integrating measuring (SPL exclusive) and revoke auto off function.
7. Display measurement readings on LCD.
Peak sound pressure (PeakMAX) does not support time and frequency weighting.
CAUTION
Please mount windscreen to microphone as shown in figure below to reduce wind noise when ambient wind speed is greater than 10m/sec.
Page 7
ST-109R
- 4 -
4
5.1 Backlight Button
In standby modePress button to turn on backlight, press button again to turn it off
immediately. Backlight will turn off in 15 seconds automatically.
5.2 Start/Pause Measuring
Press button to start integrating Leq/SEL/PeakMAX and MAX/MIN lock-up function with the maximum and minimum values displayed at the lower row of LCD and measurement interval
upper row of LCD. Press button to pause measurement and button to abort measurement.
The longest time that the SPL mode, SEL, and
peak sound pressure mode can last is 99 hours, 59 minutes and 59 seconds.
5.3 Data Hold:
Press button to the on/off data HOLD. If the integrating is started, this function is invalid.
5.4 Single Record/ Datalogger Reading
Each press the button once to display REC message, increment record count by 1 and log one measurement record.
Press and hold button for 1 second to enter record reading mode, press / button to reading
records, press / button to toggle switch time display between hh:mm:ss and yyyy/mm/dd, press
and hold button for 1 second to exit reading function.
Page 8
ST-109R
- 5 -
5
5.5 Product Setup
Press button to enter set-up mode of this product for the following: Press the button to cycle through the following options:
Clock → Auto record → Auto power off → Communication interface → Delete one record → Delete all record → Copy SD card → 94dB calibrate → Back to measurement mode
Select settings
/ Select place settings
/ Select value up/down
Enter data delete/copy Enter setup and exit setup page
Please get your SD card installed before enabling SD card copy function. Please refer to section 5.9 for details.
5.6 Integrating Time Setup
In Leg mode the record and integrating time settings are the same:
Press button to enter Integrating time selection page, the LCD display REC with the following options for selection:
10 seconds → 1 minute → 5 minute → 10 minute → 30 minute → 1 hour → 8 hour → 16 hour → 1 day → Custom.
Press / button to point cursors, / button to change values, with the maximum settings at 23 hours, 59 minutes and 59 seconds.
Enter setup and exit setup page.
5.7 Auto Power Off
The longest auto power off time is 99 minutes; set this to zero to disable the auto off function. The auto power off will be disabled accordingly in the USB connection mode.
Page 9
ST-109R
- 6 -
6
5.8 Analog/Communication Output
Interface
This product features to computer communication inter-face: USB and RS-232. The RS-232 (TTL) and analog output inter-face shares. You may select USB or RS232 inter-face in the set-up mode. The default value is USB. AC signal output: MAX: 5VP-P/130dB, output impedance around 600Ω DC signal output: 10mV/10dB, output impedance around
100Ω
5.9 Record Data Delete/Back-up
You may define the file name with a desktop program: file extension is "*.IAR", file name may contain up to 8 characters including capital letter A~F and number 0~9. The auto backup function copies data from this product to micro SD card and delete them afterwards. Please connect to external power source for micro SD card write-in operation to prevent it from failed due to power outage. You may manually delete records in the mode of a single record or all records. The single record delete function erases the latest one first and move to the earlies one. See section 5.5 for the functions of individual buttons.
ID of this product is "FFFFFFFF" by default. This product supports a micro SD card in the
FAT16/FAT32 format. The maximum space supported in SD/SDHC mode is
32GB.
Page 10
ST-109R
- 7 -
7
5.10 94dB Calibrate
Input 94dB@1KHZ signal. Last calibration records are displayed at the lower right corner of LCD. Current measurement value is displayed at the lower left corner of LCD. Time weight value is Fast by default. Calibration range: 91dB~97dB.
Press button to the selection frequency weight. Press button to select shift.
Press button to select full calibration. Press button to select next setup mode.
Press button to save calibration value and exit set-up mode.
5.11 Microphone Connection Inter-face
Pin 1: signal input Pin 2: ground Pin 3: power supply Pin 4: X
Page 11
ST-109R
- 8 -
8
5.12 Microphone Extension Test
To avoid measurement deviation due to the reflection effect and invalid operations you may measure integrating sound levels by extending the microphone with an extension cord.
Press button to power off this product. Turn the pre-amplifier and microphone
counterclockwise to remove them from the body as shown in figure below:
Connect extension cord to the pre-amplifier and
microphone as shown in the figure below:
Page 12
ST-109R
- 9 -
9
5.13 Sensitivity Correction
Frequency
Deviation pressure
20-400
0
500
0
630
0
800
0
1000
0.2
1250
0.3
1600
0.4
2000
0.5
2500
0.6
3150
0.7
4000
0.9
5000
1.5
6300
2.3
8000
3.5
10000
5
12500
6.5
16000
8.7
20000
10.3
* Microphone specification: ST-109
Page 13
ST-109R
- 10 -
10
6 Software Installation
Operating system support: Windows XP/Windows7 /Windows 8.1/Windows 10
Insert the DVD ROM included with this product in the
DVD drive of the computer connected to this product, click to execute the Installer program.
Remove the DVD once the desktop program is installed
successfully.
Connect this product to a computer with included USB
cable.
To execute desktop program: double click the Integrating
Sound Level Meter program icon to start it.
See Software Installation Guide for details on software
operation.
Page 14
ST-109R
- 11 -
11
7 General Specifications
Readings display: two rows with maximum
value at 1999.
Lower power detection, backlight function, data
lock function (HOLD)
Auto power On/Off function Overload display: "OVER" or "UNDER" Storage interval: 1 second~ 24 hours; up to
35,000 records.
Battery: 1.5V*4(LR6 – AA – AM3 – MN 1500) Battery life: Approximately 30 hours Power consumption at standby mode: 10uW Power consumption at operation mode:
250mW
Operation temperature and humidity: 5~40
with relative humidity up to 80%
Storage temperature and humidity: -10~60
with relative humidity up to 70%
Weight: Approximately 500 grams Dimensions: 285(L)x90(W)x39(H) mm Adapter specification:
Convert external AC 100~240V power to DC 9V/0.5A Specification: Voltage at DC9V/0.5A Plug: O.D.: 5.5mm; I.D.: 2.1mm
Page 15
ST-109R
- 12 -
12
8 Electrical specification
Display Refresh Rate
One time per second
Major Applicable Standards
IEC 616722002 Class1
IEC60651:1979 TYPE 1 IEC60804:2000 TYPE 1
Microphone
High sensitivity, 1/2” pre-polarized
capacitor microphone 50 mV/Pa
Measurement Items
Lxyp,Lxmax,Lxmin,Lxeq,LAE,Lcpeak
Measurement Range
30dB ~ 130dB (A)
35dB ~ 130dB (C)
40dB ~ 130dB (Z)
Dynamic range
60 dB
Measurement shift
30dB ~ 90dB (L) 50dB ~ 110dB (M) 70dB ~ 130dB (H)
Integrate Time Setup
Manual, 10s, 1m, 5m, 10m , 30m, 1h, 8h, 16h, 24h
Page 16
ST-109R
- 13 -
13
Micro SD Card
The max support capacity of micro SD card is 32GB 37,000 data about story space 300KB
Peak value measurement range
70~133 dBC
Time Weighting
Fast, Slow, Impulse, Peak
Frequency Weighting
A/C/Z
Frequency Range
20Hz~16KHz
DC Output
10mV/1dB
AC Output
1Vrms(±10%)/130dB each range
Starting Time
10 Second
Thermal noise
28dBA
Page 17
ST-109R
- 14 -
14
9 Maintenance or Repair
1. When the When symbol is displayed on the LCD, it means that there is insufficient power; please change the battery immediately in order to ensure its accuracy.
2. Do not place the meter in locations that have high
temperature, humidity or that are exposed to direct sunlight.
3. Remember to turn off the power after usage; remove the battery if not used for a long period of time in order to prevent battery leakage and causing damages to internal components.
10 Battery Replacement
1. Turn off the power.
2. Open the battery cover at the back of the meter,
remove the batteries.
3. Insert four batteries in the correct
positive-negative polarity.
4. Put the battery cover back in place.
11 Product Disposal
Note: This symbol indicates that the meter and its accessories must be separated and processed properly.
Page 18
Page 19
Page 20
TENMARS ELECTRONICS CO., LTD.
6F, NO.586 Ruiguang Rd, Neihu Dist.
Taipei City, Taiwan
E-mail: service@tenmars.com
http://www.tenmars.com
Loading...