Tenda PWRS-0026, BCKP-0029 User Manual

Page 1
PWRS-0026
BCKP-0029
6U CompactPCI
Power Supply with UPS
13 Altalef St.
Yehud, Israel 56216 Tel: 972 (3) 632-0533 Fax: 972 (3) 632-0458
www.tenta.com
919 Kifer Road
Tel: (408) 328-1370
Fax: (408) 328-1371
Page 2
Document Revisions
Rev Comment BY Date
E0 Release - Preliminary E0.1 Additions and corrections E1.0 Release, Windows utility added, UPS time
defaults changed
E2.0 Update document format
DG DG DG
TJ
11/25/00 12/07/00 04/16/01
01/10/02
PWRS-0026 User Manual Page 2 of 19
Page 3
Table of Contents
I. Ordering Information ......................................................................4
II. System Configuration.....................................................................5
III. Specifications ..............................................................................7
A. Physical Specifications....................................................................... 7
B. Environmental Specifications............................................................. 8
C. Front Panel Indicators......................................................................... 8
D. Power Specification............................................................................. 8
E. On Board Fuses................................................................................... 9
IV. Power Supply Card....................................................................10
A. Power Supply Block Diagram........................................................... 10
B. UPS Option......................................................................................... 11
C. Functionality ......................................................................................11
V. Logic Board ...................................................................................12
A. LOGIC Board Block Diagram............................................................ 13
VI. BACKUP Board..........................................................................14
A. Battery Backup Block Diagram......................................................... 15
VII. PCI Driver Operation .................................................................16
VIII. Handshake Mode Operation .....................................................17
IX. Memory Map...............................................................................18
X. Warranty.........................................................................................19
PWRS-0026 User Manual Page 3 of 19
Page 4
I. Ordering Information
Part Number Description
AS00026-01 Power supply card, 130 watts, 6U, M type connector AS00030-01 UPS logic board, 6U AS00043-01 Power supply with UPS logic board AS00029-01 Battery back up module, 6U
PWRS-0026 User Manual Page 4 of 19
Page 5
II. System Configuration
This document describes the specifications and functionality of Tenta’s 6U CompactPCI Power Distribution board with UPS. The power supply board provides power signals through M-type connector to the CompactPCI back plane. It may be used stand alone, or with the optional UPS logic and battery backup module. The power supply board form factor, physical dimension and BUS interface comply with CompactPCI Specification PICMG 2.0 R2.1.
PWRS-0026 User Manual Page 5 of 19
Page 6
The full system consists of three main components. The power supply can be used stand alone, or combined with items #2 - #3 for a full UPS system.
1) PS
Power conversion : AC/DC: 90-132 / 180-264 VAC -> 15V
DC/DC: conversion of 15V to 5V,3.3V,±12V
2) LOGIC
Charger for Ni-Cd battery PCI Interface Serial Logic
3) BACKUP
Ni-Cd battery pack Serial Interface
PWRS-0026 User Manual Page 6 of 19
Page 7
III. Specifications
A. Physical Specifications
Criteria Specifications
PS and LOGIC
PCB Dimensions 233MM (9.1875”) Height X 160MM
Form Factor Plug in Euro card, 6U Height, IEEE Connectors M-Type Connector on power board;
Front Panel 262mm Height X 50mm Width x 2mm
Weight 900g
BACKUP
PCB Dimensions 233MM (9.1875”) Height X 80MM
Form Factor Plug in Euro card, 6U Height, IEEE Connectors Metric 2.0mm grid female connector for Front Panel 262mm Height X 50mm Width x 2mm
Weight 800g
(6.2992”) Depth X 1.6MM (0.0629”) Thickness
(1101.1, 101.10 and P1101.11) metric 2.0mm grid female connector for
J1 (cPCI BUS) and J5 (signal distribution) on logic board
Thickness, with power and status indication LED’s
(3.1496”) Depth X 1.6MM (0.0629”) Thickness
(1101.1, 101.10 and P1101.11) J5 (signal distribution) Thickness with dsub9 female
(handshake signal connector)
PWRS-0026 User Manual Page 7 of 19
Page 8
B. Environmental Specifications
Criteria Specifications
Operating temperature Storage -40 to +85 ºC Humidity 5 to 95% non-condensing
0-70 ºC
C. Front Panel Indicators
Label Function
+12V +12 VDC supply, green
-12V -12 VDC supply, green +15V +15 VDC supply, green +5V +5 VDC supply, green +3.3V +3.3 VDC supply, green NT SHT DWN NT in shutdown state, green, blinking PWR FAIL Loss of AC power, red CHRG/COMP Battery charging, orange; Battery fully
charged, green
D. Power Specification
Criteria Voltage Power
AC - DC 90-132 / 180-264 -> 15V ~130W
DC - DC 15V -> 3.3V ~30W 15V -> 5V ~75W 15V -> ±12V ~25W
PWRS-0026 User Manual Page 8 of 19
Page 9
E. On Board Fuses
Fuse Voltage Value
F1 +12V 3A F2 -12V 0.375A F3 +3.3V 5A F4 +5V 10A F5 +5V 10A
PWRS-0026 User Manual Page 9 of 19
Page 10
IV. Power Supply Card
PS PCBA is responsible for converting AC input line to all required DC voltages needed in a cPCI system. It uses an AC/DC of 130W for the f irst phase and is designed for future upgrade to 180W with no additional PCB modifications. Three DC/DC converters provide conversion of the 15V (AC/DC output) to all required DC levels; one for 5V, one for 3.3V and one for ±12V.
A. Power Supply Block Diagram
AC IN
connector
DC-DC
ACL
ACN
AC/DC
Input :
190-132/180-264V
Output :
15V
5V,75W
DC-DC
3V,30W
DC-DC
+-12V,25W
M-type Conne
ctor
Transition Connector
signals
including:
charger status, NT staus and
power failure
LED's
LED Indication
PWRS-0026 User Manual Page 10 of 19
P/S board shown with Logic board
Page 11
B. UPS Option
The UPS option provides battery backup, up to 5 minutes, in order to allow the operating system to safely shut down upon a power failure. This system consists of two major components:
LOGIC is a mezzanine board to the PS card. It contains cPCI backplane connections through J1 and J5. J1 is used for PCI interface to the HOST, and J5 is used for power signal transition between the battery and the charger, and also used to route the control signal for power sequence between HOST and UPS control when in serial handshake mode.
BACKUP is a cPCI card which is inserted from the back side of the cage behind the second slot and contains the battery and serial port handshake connector.
C. Functionality
The UPS provides backup power during a power loss. The logic is dependent upon the driver installed. A driver for serial handshake and for a full PCI mode is available. In either case, a charge circuit continually monitors the battery and provides charging when needed. The charge point has built in hysteresis. During a standard operating system shutdown, the UPS is not activated. During power loss, a shutdown under battery power is completed.
PWRS-0026 User Manual Page 11 of 19
Page 12
V. Logic Board
LOGIC board is responsible for :
1) PCI interface with the HOST, achieved by using a smart PCI to LOCAL bridge
2) UPS control – including charger circuitry, power failure detection and handshake with NT via serial bus or CPCI bus for power shut down sequence.
3) Routing power signals from the BACKUP board to PS during power failure.
The power failure detection circuit is responsible for identifying a power failure and switching the Backup. During a short power loss, the logic (with selectable FAIL_TIME), may rely on internal capacitance to ensure continuous operation rather than aborting to a shutdown mode.
PWRS-0026 User Manual Page 12 of 19
Page 13
A. LOGIC Board Block Diagram
Battery related
signals
configuration
Charger
circuitry
Charge Control
UPS control
system
power
sequence
Control
Serial Interface
PCI to LOCAL
Bridge
Staus
signals
power
fault
staus
indication
LED's
PCI Interface
signals
Isolation
J5 PCI
Connector
Transition connector
battery
on/off
J1 PCI
Connector
PWRS-0026 User Manual Page 13 of 19
Page 14
VI. BACKUP Board
BACKUP holds the battery pack on rear side of the cage, and provides power to the LOGIC board through J5 (CPCI standard connector). A D­sub 9 connector also provides handshake logic signals with a selected COM port.
The battery pack is capable of powering a 130 watt system for a minimium of 5 minutes. The 12 VDC battery pack consists of (10) 1.2 VDC cells in series, and can supply 10.8 amps for more than 5 minutes as shown in the graph below:
120 W 72 W 48 W
Charging time of fully discharged battery pack lasts 5 hours maximum. Typical charging time is 3.6 hours. Battery is rated for 500 full discharge to charge cycles.
PWRS-0026 User Manual Page 14 of 19
Page 15
A. Battery Backup Block Diagram
control
signals
Battery Pack
battery power
CPCI J5
connector
battery on/off
Switch on/
off circuit
Serial port
Serial Handshake Signal Connector
Ref Signal name BACKUP Signal COM x Signal
1 NT_CLSD 4 4 2 NT_SHTDWN_BUF 8 8
battery power
NT & UPS derial interface
PWRS-0026 User Manual Page 15 of 19
Page 16
VII. PCI Driver Operation
A Windows NT driver is provided to manage all UPS functions. After installation, the driver will run as a back ground service, and provides access to all set up parameters through the Control Panel icon. Select and fill in any parameters which need to be modified from default. All communication between the processor and UPS is through the PCI bus.
Default for UPS Time is 120,000 ms. Default for Fail Time is 1,000 ms.
Logic:
On power up, the UPS driver task starts automatically. Assuming that the UPS driver is installed and activated through the Control Panel utility, the UPS is enabled and begins charging. CHRG/COMP will be orange. Upon being fully charged, CHRG/COMP will turn green.
The system continuously checks for a power failure, indicated by the PWR FAIL LED. A voltage loss for less than Fail Time will have no effect on the system. A voltage loss for Fail Tim e or greater will result in System Shutdown with battery backup assistance.
All programs will be shut down, and the Registry will be saved. The UPS will monitor this activity, and upon completion will turn off the System.
If for any reason this does not happen (ie. operating system locks up), the UPS will turn off the System after a time period of UPS_TIME.
Upon a User selected Shutdown of NT, all battery backup functionality is disabled.
PWRS-0026 User Manual Page 16 of 19
Page 17
VIII. Handshake Mode Operation
The following describes the internal logic and variables used in Handshake Mode. The standard NT UPS functionality is used in addition to the following logic. A driver and DOS utility are provided with this functionality.
On power up, UPS_ENABLE = 0 After NT completes boot, set UPS_ENABLE = 1
POWER_OK = 1 until power detection circuit determines power loss, then POWER_OK = 0 FAIL_MODE = 1 if POWER_OK = 0 for more than FAIL_TIME If FAIL_MODE and UPS_ENABLE = 1, provide UPS battery power until time > UPS_TIME or REMOTE_UPS_SHUTDOWN is received.
On standard NT shut-down, UPS functionality is disabled.
Definition of terms:
UPS_ENABLE Internal register which controls enable
state of UPS
POWER_OK Internal register which indicates status of
incoming power line
FAIL_TIME Time that a no power condition is
detected until FAIL_MODE = 1
UPS_TIME Time that power is supplied after
FAIL_MODE = 1
REMOTE_UPS_SHUTDOWN COM port handshake signal from CPU
to shut down supply. Default time delay is 2 minutes.
PWRS-0026 User Manual Page 17 of 19
Page 18
IX. Memory Map
Name Description Enable battery to supply power to the BUS in “fail mode” Offset 0x0 Size 32bit Values 1 Enable
Default Disable Updated by NT program
Name Description Time to supply power for shutdown Offset 0x4 Size 32bit Values 10000ms to 300000ms Scale Factor 127ms Default 120000ms Updated by NT program
Name Description Acceptable duration of power loss before triggering a shutdown Offset 0x8 Size 32bit Values 50ms to 2000ms Scale Factor 16 ms Default 1000 ms Updated by NT program
Name Description Power status Offset 0xC Size 32bit Values 0 no power
Default 1 Updated by Power supply board
UPS_ENABLE
0 Disable
UPS_TIME
FAIL_TIME
POWER_OK
1 power OK
PWRS-0026 User Manual Page 18 of 19
Page 19
X. Warranty
Tenta Technology warrants the original purchaser for two years from the date of delivery for any defect in the product, material or workmanship. Product should be used in suitable installation environment and for the purposes it was designed. Any damages caused by natural disasters such as: fire, flood, wind and lightning are not covered. For more information, please contact Tenta Technology customer support (see locations on front page). Tenta Technology hardware and software are not intended for use in any manner when human life or safety is at risk and not for use in life support equipment.
PWRS-0026 User Manual Page 19 of 19