TEMPEST TECHNOLOGY CORPORATION® is the leading manufacturer of products
and accessories for environmental management in reghting and industrial applications.
TEMPEST® has expanded into other industries and found new applications for its
products. e TEMPEST POWER BLOWER® and PPV/PPA are used by construction
contractors to control dust, fumes and unhealthy gases like carbon monoxide, greatly
improving safety in conned spaces.
TEMPEST® began as a manufacturer of gasoline
and electric powered blowers for the re service.
ese departments use the TEMPEST POWER
BLOWER® to provide “Positive Pressure Ventilation / Attack”(PPV/PPA) to remove heat, gases
and smoke from the interior of a burning structure.
TEMPEST TECHNOLOGY CORPORATION® has earned a reputation as a leader and
innovator in the air movement industry and continues in that role today.
Page 1
Page 3
About This Manual
is manual is produced solely for the use of purchasers and operators of TEMPEST
TECHNOLOGY CORPORATION® equipment. Any reproduction, retransmission, or
other use of the contents of this manual without written consent of TEMPEST TECHNOLOGY CORPORATION® is strictly prohibited.
It is the intent of this manual to provide the owner/operator of TEMPEST® products
with both general and specic information regarding the safe and proper operation and
maintenance of the equipment described within.
CONTACT:
If aer careful review, any questions arise concerning any portion of this manual, please contact TEMPEST TECHNOLOGY CORPORATION® for
assistance:
INTRODUCTION 1
ABOUT THIS MANUAL 2
CONTACT INFORMATION 2
SAFETY GUIDE 4
GENERAL INFORMATION 5
BLOWER IDENTIFICATION 5
SERIAL NUMBER LOCATION 5
WARRANTY 5
POWER BLOWER DATA 6-7
POWER BLOWER INFORMATION 8
OPERATING PROCEDURES 9-12
PRE OPERATION 9
VISUAL INSPECTION 9
OPERATION 9
SET-UP 9
STARTING, ADJUSTING, STOPPING - VSX 10
STARTING, ADJUSTING, STOPPING - VSG 11
STARTING, ADJUSTING, STOPPING - VSM 11
STARTING, ADJUSTING, STOPPING - Single Speed 12
MAINTENANCE PROCEDURES 13-16
MAINTENANCE SCHEDULE 13
BLADE REMOVAL AND INSTALLATION, 3-BOLT DESIGN 13-14
BLADE REMOVAL AND INSTALLATION, 2-BOLT REAR DESIGN 15
TROUBLE SHOOTING - VSX 16-18
TROUBLE SHOOTING - VSG 19
TROUBLE SHOOTING - VSM 20
TROUBLE SHOOTING - Single Speed 21
NOTES 22
EXPLODED VIEW - VSM & SINGLE SPEED 23
PARTS LIST - VSM & SINGLE SPEED 24
EXPLODED VIEW - VSX & VSG 25
PARTS LIST - VSX & VSG 26
Page 3
Page 5
Safety Guide
Failure to follow the operating, maintenance and lubrication requirements set forth in
this Operation and Maintenance Manual may result in serious personal injury and/or
damage to equipment.
e following WARNING statements indicate potentially hazardous conditions for operators and equipment. Make certain that anyone who works on or around the blower
has read and fully understands the safety precautions listed.
1. Carefully read this Operation and Maintenance Manual before attempting to
operate, service or disassemble any part of your TEMPEST POWER BLOWER®.
2. DO NOT operate the unit when mentally or physically fatigued or impaired.
3. Stay away from rotating parts; avoid wearing loose jackets, shirts, and ties. Keep
hands and feet away from the blower.
4. Keep all unauthorized personnel at a safe distance from the blower.
5. Keep all guards in place. DO NOT make repairs while the unit is running. DO
NOT operate if any guard or grill is not in place.
6. Always wear eye protection. Loose debris can be picked up in the air
stream and own in the air.
7. Hearing protection is required. Motor and air noise may exceed safe dB levels.
8. DO NOT move blower while it is running!
9. It is the sole responsibility of the owner/operator to develop and practice the
proper use of the TEMPEST POWER BLOWER® in accordance with generally
accepted ventilation procedures as well as the department’s own operating proce dures before placing the unit into service.
Page 4
Page 6
General Information
Blower Identication
Each TEMPEST POWER BLOWER® has a model number as well as a serial number. e
model number signies information such as blade diameter, engine type and horsepower. e serial number relates to information referencing the date of manufacture. is
information is useful should it become necessary to contact the factory regarding your
Power Blower.
SERIAL NUMBER LOCATIONS
ELECTRIC POWER UNITS:
e serial number is located on a small plate
welded to the frame.
Please write the Serial Number of your TEMPEST POWER BLOWER® in the spaces
below. is will aid us in identifying which
model you have when assisting you.
Model
Date
Serial No.
Blower Identication
is plate/information may be
located on the le or right side
of the Blower.
Warranty
Please visit www.tempest-feedback.com to complete your warranty information
and activate your warranty.
Page 5
Page 7
Power Blower Data
TYPE:
Positive Pressure Ventilator
BLADE:
Air Flex Fiberglass Reinforced Polyamide
BUSHING:
Keyed Sha and Set or Cap Screws.
SHROUD:
Turbo 2000 Tapered Aluminum.
DRIVE:
Direct-drive Electric Motor.
BEARINGS:
Locking, Self-Aligning and Permanently Lubricated.
FRAME:
Rugged, Lightweight, Square-Steel Tubing with Powder-Coat Finish.
Continuous Circular-Wound, External-Weld Steel Wire with 8 Tie Points for Ad ditional Safety.
VIBRATION DAMPENERS:
Steel-Reinforced Rubber.
Page 6
Page 8
Power Blower Data Continued
SINGLE SPEED ELECTRIC POWER BLOWERS
Model Part # Blade Size Dimensions (WxDxH) Weight CFM
EBS-16 700-108 16” 18.75” x 14.25” x 19.50” 47 lbs. 3,200
EB-16700-099 16” 18.50” x 20.00” x 20.50” 66 lbs. 11,804
EB-18 700-056 18” 22.25” x 21.00” x 24.00” 71 lbs. 8,748
EB-21 700-060 21” 25.00” x 21.00” x 26.00” 72 lbs. 11,968
EB-24 700-062 24” 28.25” x 22.50” x 30.00” 75 lbs. 12,867
VSG VARIABLE SPEED BLOWERS
Model Part # Blade Size Dimensions (WxDxH) Weight CFM
EB-16-VSG700-316 16” 19.25” x 19.25” x 21.25” 83 lbs. 11,125
EB-18-VSG 700-318 18” 23.50” x 20.75” x 24.00” 88 lbs. 11,861
EB-21-VSG 700-321 21” 25.50” x 20.75” x 26.25” 94 lbs. 13,414
EB-24-VSG 700-324 24” 28.25” x 21.25” x 30.00” 100 lbs. 12,901
VSX VARIABLE SPEED BLOWERS
Model Part # Blade Size Dimensions (WxDxH) Weight CFM
EB-16-VSX700-350 16” 19.25” x 19.25” x 21.25” 86 lbs. 11,804
EB-18-VSX 700-352 18” 23.50” x 20.75” x 24.00” 91 lbs. 8,748
EB-21-VSX 700-354 21” 25.50” x 20.75” x 26.25” 97 lbs. 11,968
EB-24-VSX 700-356 24” 28.25” x 21.25” x 30.00” 102 lbs. 12,867
VSM VARIABLE SPEED BLOWERS
Model Part # Blade Size Dimensions (WxDxH) Weight CFM
EB-16-VSM700-261 16” 19.00” x 19.25” x 21.25” 66 lbs. 10,650
EB-18-VSM 700-262 18” 22.25” x 20.75” x 24.00” 71 lbs. 8,465
EB-21-VSM 700-263 21” 25.00” x 20.75” x 26.25” 76 lbs. 11,475
Page 7
Page 9
Power Blower Information
e TEMPEST POWER BLOWER® is a
high powered, portable blower used for
Positive Pressure Ventilation and Attack
(PPV/PPA), ventilation techniques that
quickly and eciently replaces hazardous
interior environments.
PPV and PPA were pioneered in the re ghting industry where re ghters use the
TEMPEST POWER BLOWER® to ventilate smoke, heat, and harmful gases from buildings. is creates a safer environment for them to work in and makes it easier for them
to nd victims and extinguish the re.
PPV amd PPA rely on two principles, (1) a cone shaped air pattern, and (2) pressure. To
accomplish Positive Pressure Ventilation or Attack, the blower is placed on the outside
of the structure. It is positioned so that the cone shaped air pattern created by the blower
completely seals the entrance opening (Figure 1.2). When this seal is achieved, the air
pressure is increased equally at all points inside the structure. When an exhaust opening
is created, all of the interior air moves in one mass towards it. e result is fast, ecient
ventilation of the entire structure.
Figure 1.2
NOTE:
e TEMPEST POWER BLOWER® is the most ecient tool for PPV and
PPA for two reasons. First, the exclusive Tempest tapered shroud design
creates a wide, stable, conical air pattern. Second, the seven blade air movement impeller used on all Tempest blowers is designed to create high pressure. ese two features make the TEMPEST POWER BLOWER® such a
powerful ventilation tool.
As with any new technique, Positive Pressure Ventilation requires training
and education in order to be implemented properly and safely. Tempest offers access to a complete line of training materials, which cover many applications for this powerful ventilation technique. For more information visit
www.tempest-edge.com, www.positivepressuretraining.com or contact us at
1.800.346.2143.
Page 8
Page 10
Operating Procedures
Pre-Operation
VISUAL INSPECTION
Aer receiving and unpacking your blower, be sure to carefully inspect it for any damage that might have occurred during shipping. Should you nd any damage:
PLEASE NOTIFY TEMPEST TECHNOLOGY CORP.® IMMEDIATELY AT
1.800.346.2143
Operation
SET-UP, STARTING AND STOPPING
Assuming the previous Pre-Operation instructions have been followed the blower is
now ready to run.
WHEN USING A GENERATOR, IT IS IMPERATIVE THAT THE GEN
ERATOR BE RUNNING AT FULL CAPACITY BEFORE PLUGGING IN
ANY ELECTRIC BLOWER.
CAUTION: DO NOT MOVE THE BLOWER WHILE IT IS IN OPERATION. SEVERE PERSONAL INJURY IS POSSIBLE AS WELL AS DAMAGE
TO THE BLOWER.
ALWAYS SHUT-DOWN THE BLOWER PRIOR TO MOVING!
SET-UP
Position the blower in the desired location, making sure it is placed on a at, hard and
debris free surface.
NOTE:
e following sections cover separate operating instructions for each type of
electric blower. Please be sure to follow the operating instructions specic to
your particular blower model. (ex. VSG, VSX, VSM, Single Speed)
Page 9
Page 11
Operating Procedures Continued
l
STARTING - VSX (WILL NOT RUN ON GFCI CIRCUITS)
1. Plug the blower power cord into power source recep-
tacle. e following displays on the LED screen im mediately upon applying power:
LED ashes a 3 digit number (parameter version)
momentarily, then...
STOP condition indicator is displayed.
2. Using the INCREASE button and/or the
DECREASE button, set the desired operation
load %. Operation loads range from approximately
10% to 100%.
3. Start the blower by depressing the green button.
ADJUSTING SPEED WITH BLOWER ON
It is safe to change speed while the blower is running
simply depress INCREASE or DECREASE
buttons to set to desired speed.
395
---
STOPPING
To stop operation, depress the red button.
NOTE:
RPM setting at shut down will be the same RPM setting at restart.
CAUTION:
DO NOT plug the unit in again until the LED display is clear (blank.)
O
Page 10
Page 12
Operating Procedures Continued
STARTING - VSG
1. Check that toggle switch is set to STOP.
2. Plug the blower cord into power source receptacle. If
power is properly brought to the control, the “ON” LED
and the “STOP” LED indicators will be lit.
3. Engage START toggle. e toggle is momentary
switch to start. e center position is the run location.
STOPPING
Stop unit before unplugging from power source. Make
sure toggle is set to STOP.
STARTING - VSM
1. Set speed control knob (rheostat) to STOP.
2. Plug blower power cord into power supply.
3. Adjust rheostat to desired RPM. e GREEN LED
will indicate power is supplied to unit.
STOPPING
Turn rheostat knob to the STOP position to shut the unit o. DO NOT unplug unit
before shutting o.
Page 11
Page 13
Operating Procedures Continued
STARTING - Single Speed
-NO SWITCH
Plug blower into power source. Unit will begin running
automatically.
-WITH SWITCH
1. Ensure blower toggle is switched to the o position.
2. Plug blower into power source.
3. Switch toggle to the ON position.
STOPPING
-NO SWITCH
Unplug unit from power source or switch o power source.
-WITH SWITCH
Stop unit before unplugging from power source. Make
sure toggle switch is set to STOP.
SINGLE SPEED REQUIREMENTS
Based on 115v blower on a 20 amp circuit
Model
Motor HPStarting
Amps
Starting
Watts
Running
Amps
Starting
Watts
EB-16 1.5 54.6 6,300 18.2 2,100
EBS-16 1/3 10.9 1,300 6.3 756
EB-18 148 6,000 16 1,900
EB-21 1 48 6,000 16 1,900
EB-24 1 48 6,000 16 1,900
MAXIMUM POWER CORD LENGTH
Based on 1 blower on a 20 amp circuit
Motor HP
14 gauge 12 gauge 10 gauge 8 gauge 6 gauge
EBS-16 215’ 330’ 550’ 850’ 1,350’
EB-16 60’ 95’ 150’ 240’ 380’
EB-18 45’ 65’ 115’ 190’ 300’
Page 12
Page 14
Maintenance Procedures
Although the Tempest Variable Speed Blowers are designed to eliminate most maintenance issues, it is imperative that the blowers be inspected before startup on each use.
Please review the following list before using this product.
MAINTENANCE SCHEDULE
EVERY USE INSPECT BLOWER FOR DAMAGE AND FIX IF ANY
TIGHTEN/REPLACE ANY LOOSE OR MISSING PARTS
INSPECT BLADE FOR NICKS/CUTS OR DAMAGE
EVERY MONTH OR 10 HOURS INSPECT & CLEAN SHROUD & GRILLS
If the blade has made contact with a hard object, and damage has occurred, please follow these simple instructions for removing and reinstalling the blade assembly.
BLADE REMOVAL/INSTALLATION
PROCEDURES
IMPORTANT: Tempest Variable and Single Speed Electric Power Blowers feature
two dierent blade to sha mount designs. When attempting to remove/install a blade
to your electric blower, you will need to identify which design your blower uses. e
instructions on the following pages touch on both designs individually. Using the images provided, match the blade-sha design you have with the ones shown in order to
decide which set of directions to follow. If you have any questions, please contact us a
1.800.346.2143
BLADE REMOVAL PROCEDURES
1. Remove the eight bolts holding the front grill in
place and remove the grill. (Figure 4.1)
Page 13
Figure 4.1
Page 15
Maintenance Procedures Continued
2. Remove the three bolts from blade and remove the
blade from the hub. (Figure 4.2) Remove the two bolts
that secure the bushing to the hub. Put the two bolts in
the threaded part of the bushing and turn evenly until
bushing separates from hub.
BLADE INSTALLATION PROCEDURES
Make sure that the sha and keyway are clean and
1.
smooth before installing the bushing. Remove the
hub from the new blade assembly.
Put “Loc-Tite” on the screws that secure the bushing
2.
to the hub. Insert the cap screws through the clearance holes in the bushing and loosely place the bushing into the hub of the blade. Do not press the bushing in. Hand start the screws into the hub, turning
them just enough to engage the threads in the tapped
holes on the hub. e bushing should be loose in the
hub. Place the hub and the bushing onto the motor
sha. Insert the key into the keyway (Figure 4.3) and
tighten the two bolts drawing the bushing and hub
together.
Slide the blade onto the bushing/hub assembly and place “Lock-Tite” on the three
3.
bolts, then insert the three bolts through the blade and turn evenly but do not tighten.
Make sure blade is in line with hub then tighten bolts (Figure 4.3). Locate the blade
and bushing so that the blade tips do not hit the rear grill eyelets.
Figure 4.2
Figure 4.3
NOTE:
On some models the blade and bushing may be in beyond or out away from the end
of the sha up to ¼” but no further. is is necessary for proper blade clearance.
Tighten the cap screw bolts progressively with a wrench. Tighten each cap screw, par-
4.
tial turns successively until all are tight. Final tightening should be done with torque
wrench with the torque set at 7.5 /lbs. for each screw. Over tightening will cause the
cap screws to break or crack the blade. (Figure 4.2)
Carefully turn the blade and check for clearance between the blade and shroud. Con-
5.
rm that the blade is free to rotate without hitting other parts.
Reinstall the front grill and test the blower.
6.
If you have any trouble removing or installing the blade on your blower, contact the
7.
factory for assistance at 1.800.346.2143.
Page 14
Page 16
Maintenance Procedures Continued
BLADE REMOVAL PROCEDURES
Remove the eight bolts holding the front grill in
1.
place and remove the grill. (Figure 4.1, Page 13)
Remove the three Allen bolts from blade/hub assem-
2.
bly. DO NOT remove the four nuts/bolts holding
the two blade hub halves that secure the blade ns.
(Figure 5.1)
3.
Insert bolts into adjoining threaded holes of blade/
hub assembly, hand tighten.
(Figure 5.2)
4.
With Allen wrench, consecutively tighten bolt 1,2,3
half turn and repeat until blade separates from bushing.
BUSHING REMOVAL
Loosen Allen set screw. Insert small screw driver into
bushing slot applying a little pressure to release bushing
from engine sha. (Some bushings may have a set screw
securing the bushing to the key on the motor sha). Be
careful not to damage end of sha. (Figure 5.3)
Figure 5.1
Figure 5.2
BLADE INSTALLATION
1.
Check key. A worn key should be replaced. Make
sure motor sha keyway is clean.
2.
Align bushing keyway with sha key and position
bushing on sha to insure blade ns are centered
between front and rear grill mounting bolts. Put blue
“Loc-Tite” on bushing allen set screw and tighten.
3.
Align non-threaded holes of blade/hub assembly
with threaded holes of bushing. Put lock washers on
bushing bolts. Put blue “Loc-Tite” on bushing bolts.
Insert through non-threaded holes of blade/hub assembly, hand tighten. With Allen wrench tighten
bolts 1,2,3 consecutively until tight, torque to 7
pounds. (Figure 5.4)
4.
Reinstall the front grill and test the blower.
Figure 5.3
Figure 5.4
Page 15
Page 17
Trouble Shooting - VSX
Many factors can contribute to or be the sole cause of problems for electric power blowers. is section will identify some of these problems and provide solutions to correct
them.
BLOWER FAILS TO START
MAKE SURE BLOWER IS CONNECTED TO POWER SOURCE.
IF LED DISPLAY DOES NOT LIGHT UP:
Conrm that adequate power is being supplied to blower. If power supply is adequate,
DISCONNECT BLOWER FROM POWER SOURCE and check for loose or faulty wiring on blower electrical system and repair.
Connect blower to power source and attempt restarting, if blower still does not run,
contact Tempest at 1.800.346.2143.
IF LED DISPLAY LIGHTS UP AND:
Fault Code is given, reference Fault Code Table on the next page for diagnostics.
If “---“ appears on LED, but motor does not run, DISCONNECT BLOWER FROM POWER SOURCE and check wiring between drive and motor, repair any faulty wiring.
Also check to ensure that the EPM chip is fully inserted into the socket on the top of the
blower control. Connect blower to power source and attempt restarting, if blower still
does not run, contact manufacturer.
BLOWER RUNS THEN CUTS OFF
Check generator rating. e VSX blower series requires minimum 3.5kw rating for
maximum load operation.
Aer the blower cuts o, check the fault code reading on the LED. Reference the fault
code chart on the next page.
Page 16
Page 18
Trouble Shooting - VSX
FAULT CODES
FAULTDESCRIPTION & POSSIBLE
CAUSES
JFKEYPAD FAULT: THE COM-
MUNICATION LINK BETWEEN THE DRIVE AND
THE KEYPAD HAS BEEN
LO ST.
LFLOW DC BUS VOLT-
AGE FAULT: TYPICALLY,
CIRCUIT BREAKER HAS
TRIPPED DUE TO EXCESSIVE AMP DRAW.
ACTION
CHECK KEYPAD WIRING AND MAKE
NECESSARY REPAIRS.
L. CHECK CIRCUIT BREAKER SIZE,
RECOMMENDED SIZE FOR VSX SERIES IS 20 AMP. CHANGE CIRCUIT
BREAKER IF TOO SMALL.
LL. CHECK GENERATOR KW RATING,
IF TOO SMALL, UPGRADE GENERATOR, OR RUN BLOWER LOWER THAN
MAXIMUM BLOWER SPEED.
LLL. CHECK LINE VOLTAGE AT JBOX RECEPTACLE. LINE VOLTAGE
SHOULD BE 120V, ±10%. MAKE NECESSARY ADJUSTMENTS TO INSURE
PROPER SUPPLY VOLTAGE.
LLLL. CHECK FOR UNDERSIZED
POWER SUPPLY CORD. ACCEPTABLE
CORD IS 10/3 AWG X 200 FT. MAX.
CHANGE CORD ACCORDINGLY.
PF CURRENT OVERLOAD
FAULT: EXCESSIVE CURRENT DRAW BETWEEN
DRIVE AND MOTOR.
Page 17
L. CHECK FOR UNDERSIZED POWER
SUPPLY CORD. ACCEPTABLE CORD
IS 10/3 AWG X 200 FT. MAX. CHANGE
CORD ACCORDINGLY.
Page 19
Trouble Shooting - VSX
CHANGING EPM PROGRAM CHIP
When replacing the EPM (program chip), use a ¼” nut driver to remove the opposing
self tapping screws on the black cover of the VSX box. e EPM is located in the upper
le corner of the white controller under a small piece of protective lm. Remove the
tape and using needle nose pliers, remove the EPM and replace with new one. Replace
the tape over the EPM, replace black cover and opposing screws.
BLOWER MOVEMENT OR “WALKING”
• Adjust the rubber footpads on the back of the Blower by turning them either in or out.
Adjust the side that is walking. is will help to evenly distribute the weight of the
Blower to all four points of the frame
• Most Blowers will walk if not running at full speed, make sure the Blower is running at
full speed.
• Make sure the Blower is sitting at and not on small rocks or other objects.
Page 18
Page 20
Trouble Shooting - VSG
Many factors can contribute to or be the sole cause of problems for electric power blowers. is section will identify some of these problems and provide solutions to correct
them.
MAKE SURE BLOWER IS CONNECTED TO POWER SOURCE.
IF THE “ON” AND THE “STOP” LEDS DO NOT LIGHT UP:
Conrm that adequate power is being supplied to blower. If power supply is adequate,
DISCONNECT BLOWER FROM POWER SOURCE and check for loose or faulty wiring on blower electrical system and repair.
Connect blower to power source and attempt restarting, if blower still does not run,
contact Tempest at 1.800.346.2143.
BLOWER RUNS THEN CUTS OFF:
Check that the overload indicator light is lit. If the light is lit, this means there is insucient voltage going to the unit. is can be caused by too long of a extension cord, faulty
extension cord or low voltage from the power source. If none of the above exist, the unit
may be set to draw more amperage than the power supply delivers. If this is the case,
there is an adjustment inside the drive to correct the amperage draw when running at
100%. Please contact Tempest for instructions.
BLOWER SURGES WHEN RUNNING ON GENERATOR:
Check generator that it meets the proper voltage output to operate the blower.
BLOWER MOVEMENT OR “WALKING”
• Adjust the rubber footpads on the back of the Blower by turning them either in or out.
Adjust the side that is walking. is will help to evenly distribute the weight of the
Blower to all four points of the frame
• Most Blowers will walk if not running at full speed, make sure the Blower is running at
full speed.
• Make sure the Blower is sitting at and not on small rocks or other objects.
Page 19
Page 21
Trouble Shooting - VSM
Many factors can contribute to or be the sole cause of problems for electric power blowers. is section will identify some of these problems and provide solutions to correct
them.
MAKE SURE BLOWER IS CONNECTED TO POWER SOURCE.
BLOWER WILL NOT START WHEN RHEOSTAT TURNED:
Check the LED light on the drive. It should be lit when the rheostat is in the “RUN” position. If not lit, conrm that adequate power is being supplied to blower. If pwer supply
is adequate, DISCONNECT BLOWER FROM POWER SOURCE and check for loose
or faulty wiring on blower electrical system and repair. Connect blower to power source
and attempt restarting. If blower does not run, remove the drive cover and check the
internal wiring connections. Check the internal fuse located on the circuit board of the
drive also.
If the LED light is on and the blower will not start and all electrical connections have
been checked as in the above paragraph, the VSM drive may need to be replaced.
Contact Tempest at 1.800.346.2143 for assistance.
BLOWER MOVEMENT OR “WALKING”
• Adjust the rubber footpads on the back of the Blower by turning them either in or out.
Adjust the side that is walking. is will help to evenly distribute the weight of the
Blower to all four points of the frame
• Most Blowers will walk if not running at full speed, make sure the Blower is running at
full speed.
• Make sure the Blower is sitting at and not on small rocks or other objects.
Page 20
Page 22
Trouble Shooting - Single Speed
Many factors can contribute to or be the sole cause of problems for electric power blowers. is section will identify some of these problems and provide solutions to correct
them.
BLOWER FAILS TO START:
MAKE SURE BLOWER IS CONNECTED TO POWER SOURCE.
• oroughly check the power cord. If the cord shows any signs of serious wear it may
need to be replaced before running properly.
• Many blowers are equipped with an “automatic reset.” is reset will kill power to the
blower when the unit is at risk of overheating. Let the blower cool and attempt to start it
again.
• ere may be damage to the internal wiring. Have a qualied technician or electronics
specialists examine the blower circuitry and wiring and make any necessary repairs.
• If your Tempest Single Speed Blower is not running aer pursuing the steps mentioned
3WASHER #10 HIGH COLLAR LOCKNANA120-034120-034NANANA120-034
4WASHER 3/8 X 2 FENDER HVY Z120-037120-037120-037120-037120-037120-037120-037120-037
5
TAPER LOCK BUSHING
160-046*160-046*
Item # DescriptionPart number Part number Part number Part number Part number Part number Part number Part number
1BOLT 10-24 X 1 1/4 SOC PNANA100-059100-059NANANA100-059
21/4 X 1/2 FLAT SOC C/S ZINC100-079100-079100-079100-079100-079100-079100-079100-079
Replacement Parts For VSX and VSG Electric Powered Blowers
May 2012 and Later
VSX 16VSX 18 VSX 21VSX 24VSG 16VSG 18VSG 21VSG 24
705-102
705-107705-112705-117
260-019
260-021260-030260-068
260-071260-080
160-055160-055
160-045*160-045*
160-045*160-039
Page 26
Page 28
“Committed to Fireghter Safety.”
Mission Statement
Tempest Technology Corporation’s mission is the promotion of the
use of air as a tool for eliminating hostile interior environments
encountered by reghters, rescue teams, industrial workers, and
industrial contractors worldwide.
is mission will be accomplished by identifying opportunities
where Positive Pressure Ventilation and other ventilation techniques
can be applied to make a work or emergency environment safer and
educating manufacturers, distributors and end users through live
demonstrations and professional training programs.
Tempest will continually improve and expand its existing product line
to meet the needs of customers in various domestic and international
markets. In order to fully utilize the strength of its resources and
worldwide distribution system, Tempest will develop strategic
partnerships, add complementary product lines and engage in private
labeling agreements with other manufacturers.
www.tempest-edge.com