Tempest EBS-16, EB-16, EB-18, EB-21, EB-24 Operation Manual

...
Page 1
POWER BLOWERS®
Operations Manual
2012 Version
Tempest Gasoline Direct-Drives (Honda)
ELECTRIC
Single Speed Variable Speed VSG VSX VSM
Tempest Power Blower Electric - Single Speed
Tempest Power Blower
Electric - VSG
Tempest Power Blower
Electric - VSX
Tempest Power Blower
Electric - VSM
Page 2
Introduction
TEMPEST TECHNOLOGY CORPORATION® is the leading manufacturer of products and accessories for environmental management in reghting and industrial applica­tions.
TEMPEST® has expanded into other industries and found new applications for its products. e TEMPEST POWER BLOWER® and PPV/PPA are used by construction contractors to control dust, fumes and unhealthy gases like carbon monoxide, greatly improving safety in conned spaces.
TEMPEST® began as a manufacturer of gasoline and electric powered blowers for the re service. ese departments use the TEMPEST POWER BLOWER® to provide “Positive Pressure Ventila­tion / Attack”(PPV/PPA) to remove heat, gases and smoke from the interior of a burning struc­ture.
TEMPEST TECHNOLOGY CORPORATION® has earned a reputation as a leader and innovator in the air movement industry and continues in that role today.
Page 1
Page 3
About This Manual
is manual is produced solely for the use of purchasers and operators of TEMPEST TECHNOLOGY CORPORATION® equipment. Any reproduction, retransmission, or other use of the contents of this manual without written consent of TEMPEST TECH­NOLOGY CORPORATION® is strictly prohibited.
It is the intent of this manual to provide the owner/operator of TEMPEST® products with both general and specic information regarding the safe and proper operation and maintenance of the equipment described within.
CONTACT:
If aer careful review, any questions arise concerning any portion of this manual, please contact TEMPEST TECHNOLOGY CORPORATION® for assistance:
TEMPEST TECHNOLOGY CORP.®
4708 N. BLYTHE AVENUE FRESNO, CA 93722
Toll Free: 800.346.2143 Phone: 559.277.7577 Fax: 559.277.7579
E-MAIL: [email protected] WEB PAGE: www.tempest-edge.com
Page 2
Page 4
Table of Contents
INTRODUCTION 1 ABOUT THIS MANUAL 2 CONTACT INFORMATION 2 SAFETY GUIDE 4 GENERAL INFORMATION 5 BLOWER IDENTIFICATION 5 SERIAL NUMBER LOCATION 5 WARRANTY 5 POWER BLOWER DATA 6-7 POWER BLOWER INFORMATION 8 OPERATING PROCEDURES 9-12 PRE OPERATION 9 VISUAL INSPECTION 9 OPERATION 9 SET-UP 9 STARTING, ADJUSTING, STOPPING - VSX 10 STARTING, ADJUSTING, STOPPING - VSG 11 STARTING, ADJUSTING, STOPPING - VSM 11 STARTING, ADJUSTING, STOPPING - Single Speed 12 MAINTENANCE PROCEDURES 13-16 MAINTENANCE SCHEDULE 13 BLADE REMOVAL AND INSTALLATION, 3-BOLT DESIGN 13-14 BLADE REMOVAL AND INSTALLATION, 2-BOLT REAR DESIGN 15 TROUBLE SHOOTING - VSX 16-18 TROUBLE SHOOTING - VSG 19 TROUBLE SHOOTING - VSM 20 TROUBLE SHOOTING - Single Speed 21 NOTES 22 EXPLODED VIEW - VSM & SINGLE SPEED 23 PARTS LIST - VSM & SINGLE SPEED 24 EXPLODED VIEW - VSX & VSG 25 PARTS LIST - VSX & VSG 26
Page 3
Page 5
Safety Guide
Failure to follow the operating, maintenance and lubrication requirements set forth in this Operation and Maintenance Manual may result in serious personal injury and/or damage to equipment.
e following WARNING statements indicate potentially hazardous conditions for op­erators and equipment. Make certain that anyone who works on or around the blower has read and fully understands the safety precautions listed.
1. Carefully read this Operation and Maintenance Manual before attempting to operate, service or disassemble any part of your TEMPEST POWER BLOWER®.
2. DO NOT operate the unit when mentally or physically fatigued or impaired.
3. Stay away from rotating parts; avoid wearing loose jackets, shirts, and ties. Keep
hands and feet away from the blower.
4. Keep all unauthorized personnel at a safe distance from the blower.
5. Keep all guards in place. DO NOT make repairs while the unit is running. DO NOT operate if any guard or grill is not in place.
6. Always wear eye protection. Loose debris can be picked up in the air
stream and own in the air.
7. Hearing protection is required. Motor and air noise may exceed safe dB levels.
8. DO NOT move blower while it is running!
9. It is the sole responsibility of the owner/operator to develop and practice the
proper use of the TEMPEST POWER BLOWER® in accordance with generally accepted ventilation procedures as well as the department’s own operating proce­ dures before placing the unit into service.
Page 4
Page 6
General Information
Blower Identication
Each TEMPEST POWER BLOWER® has a model number as well as a serial number. e model number signies information such as blade diameter, engine type and horsepow­er. e serial number relates to information referencing the date of manufacture. is information is useful should it become necessary to contact the factory regarding your Power Blower.
SERIAL NUMBER LOCATIONS
ELECTRIC POWER UNITS: e serial number is located on a small plate welded to the frame.
Please write the Serial Number of your TEM­PEST POWER BLOWER® in the spaces below. is will aid us in identifying which model you have when assisting you.
Model
Date
Serial No.
Blower Identication is plate/information may be
located on the le or right side of the Blower.
Warranty
Please visit www.tempest-feedback.com to complete your warranty information and activate your warranty.
Page 5
Page 7
Power Blower Data
TYPE:
Positive Pressure Ventilator
BLADE:
Air Flex Fiberglass Reinforced Polyamide
BUSHING:
Keyed Sha and Set or Cap Screws.
SHROUD:
Turbo 2000 Tapered Aluminum.
DRIVE:
Direct-drive Electric Motor.
BEARINGS:
Locking, Self-Aligning and Permanently Lubricated.
FRAME:
Rugged, Lightweight, Square-Steel Tubing with Powder-Coat Finish.
TILT MECHANISM:
Patented Five-Positions, Foot-Operated Tilt Mechanism (e Winning Step).
GRILL:
Continuous Circular-Wound, External-Weld Steel Wire with 8 Tie Points for Ad­ ditional Safety.
VIBRATION DAMPENERS:
Steel-Reinforced Rubber.
Page 6
Page 8
Power Blower Data Continued
SINGLE SPEED ELECTRIC POWER BLOWERS
Model Part # Blade Size Dimensions (WxDxH) Weight CFM
EBS-16 700-108 16” 18.75” x 14.25” x 19.50” 47 lbs. 3,200
EB-16 700-099 16” 18.50” x 20.00” x 20.50” 66 lbs. 11,804
EB-18 700-056 18” 22.25” x 21.00” x 24.00” 71 lbs. 8,748
EB-21 700-060 21” 25.00” x 21.00” x 26.00” 72 lbs. 11,968
EB-24 700-062 24” 28.25” x 22.50” x 30.00” 75 lbs. 12,867
VSG VARIABLE SPEED BLOWERS
Model Part # Blade Size Dimensions (WxDxH) Weight CFM
EB-16-VSG 700-316 16” 19.25” x 19.25” x 21.25” 83 lbs. 11,125
EB-18-VSG 700-318 18” 23.50” x 20.75” x 24.00” 88 lbs. 11,861
EB-21-VSG 700-321 21” 25.50” x 20.75” x 26.25” 94 lbs. 13,414
EB-24-VSG 700-324 24” 28.25” x 21.25” x 30.00” 100 lbs. 12,901
VSX VARIABLE SPEED BLOWERS
Model Part # Blade Size Dimensions (WxDxH) Weight CFM
EB-16-VSX 700-350 16” 19.25” x 19.25” x 21.25” 86 lbs. 11,804
EB-18-VSX 700-352 18” 23.50” x 20.75” x 24.00” 91 lbs. 8,748
EB-21-VSX 700-354 21” 25.50” x 20.75” x 26.25” 97 lbs. 11,968
EB-24-VSX 700-356 24” 28.25” x 21.25” x 30.00” 102 lbs. 12,867
VSM VARIABLE SPEED BLOWERS
Model Part # Blade Size Dimensions (WxDxH) Weight CFM
EB-16-VSM 700-261 16” 19.00” x 19.25” x 21.25” 66 lbs. 10,650
EB-18-VSM 700-262 18” 22.25” x 20.75” x 24.00” 71 lbs. 8,465
EB-21-VSM 700-263 21” 25.00” x 20.75” x 26.25” 76 lbs. 11,475
Page 7
Page 9
Power Blower Information
e TEMPEST POWER BLOWER® is a high powered, portable blower used for Positive Pressure Ventilation and Attack (PPV/PPA), ventilation techniques that quickly and eciently replaces hazardous interior environments.
PPV and PPA were pioneered in the re ghting industry where re ghters use the TEMPEST POWER BLOWER® to ventilate smoke, heat, and harmful gases from build­ings. is creates a safer environment for them to work in and makes it easier for them to nd victims and extinguish the re.
PPV amd PPA rely on two principles, (1) a cone shaped air pattern, and (2) pressure. To accomplish Positive Pressure Ventilation or Attack, the blower is placed on the outside of the structure. It is positioned so that the cone shaped air pattern created by the blower completely seals the entrance opening (Figure 1.2). When this seal is achieved, the air pressure is increased equally at all points inside the structure. When an exhaust opening is created, all of the interior air moves in one mass towards it. e result is fast, ecient ventilation of the entire structure.
Figure 1.2
NOTE:
e TEMPEST POWER BLOWER® is the most ecient tool for PPV and PPA for two reasons. First, the exclusive Tempest tapered shroud design creates a wide, stable, conical air pattern. Second, the seven blade air move­ment impeller used on all Tempest blowers is designed to create high pres­sure. ese two features make the TEMPEST POWER BLOWER® such a powerful ventilation tool.
As with any new technique, Positive Pressure Ventilation requires training and education in order to be implemented properly and safely. Tempest of­fers access to a complete line of training materials, which cover many appli­cations for this powerful ventilation technique. For more information visit www.tempest-edge.com, www.positivepressuretraining.com or contact us at
1.800.346.2143.
Page 8
Page 10
Operating Procedures
Pre-Operation
VISUAL INSPECTION
Aer receiving and unpacking your blower, be sure to carefully inspect it for any dam­age that might have occurred during shipping. Should you nd any damage:
PLEASE NOTIFY TEMPEST TECHNOLOGY CORP.® IMMEDIATELY AT
1.800.346.2143
Operation
SET-UP, STARTING AND STOPPING
Assuming the previous Pre-Operation instructions have been followed the blower is now ready to run.
WHEN USING A GENERATOR, IT IS IMPERATIVE THAT THE GEN ERATOR BE RUNNING AT FULL CAPACITY BEFORE PLUGGING IN ANY ELECTRIC BLOWER.
CAUTION: DO NOT MOVE THE BLOWER WHILE IT IS IN OPERA­TION. SEVERE PERSONAL INJURY IS POSSIBLE AS WELL AS DAMAGE TO THE BLOWER.
ALWAYS SHUT-DOWN THE BLOWER PRIOR TO MOVING!
SET-UP
Position the blower in the desired location, making sure it is placed on a at, hard and debris free surface.
NOTE:
e following sections cover separate operating instructions for each type of electric blower. Please be sure to follow the operating instructions specic to your particular blower model. (ex. VSG, VSX, VSM, Single Speed)
Page 9
Page 11
Operating Procedures Continued
l 
STARTING - VSX (WILL NOT RUN ON GFCI CIRCUITS)
1. Plug the blower power cord into power source recep-
tacle. e following displays on the LED screen im­ mediately upon applying power:
LED ashes a 3 digit number (parameter version) momentarily, then...
STOP condition indicator is displayed.
2. Using the INCREASE button and/or the DECREASE button, set the desired operation load %. Operation loads range from approximately 10% to 100%.
3. Start the blower by depressing the green button.
ADJUSTING SPEED WITH BLOWER ON
It is safe to change speed while the blower is running simply depress INCREASE or DECREASE buttons to set to desired speed.
395
---
STOPPING
To stop operation, depress the red button.
NOTE:
RPM setting at shut down will be the same RPM setting at restart.
CAUTION:
DO NOT plug the unit in again until the LED display is clear (blank.)
O
Page 10
Page 12
Operating Procedures Continued
STARTING - VSG
1. Check that toggle switch is set to STOP.
2. Plug the blower cord into power source receptacle. If
power is properly brought to the control, the “ON” LED and the “STOP” LED indicators will be lit.
3. Engage START toggle. e toggle is momentary switch to start. e center position is the run location.
STOPPING
Stop unit before unplugging from power source. Make sure toggle is set to STOP.
STARTING - VSM
1. Set speed control knob (rheostat) to STOP.
2. Plug blower power cord into power supply.
3. Adjust rheostat to desired RPM. e GREEN LED
will indicate power is supplied to unit.
STOPPING
Turn rheostat knob to the STOP position to shut the unit o. DO NOT unplug unit before shutting o.
Page 11
Page 13
Operating Procedures Continued
STARTING - Single Speed
-NO SWITCH
Plug blower into power source. Unit will begin running automatically.
-WITH SWITCH
1. Ensure blower toggle is switched to the o position.
2. Plug blower into power source.
3. Switch toggle to the ON position.
STOPPING
-NO SWITCH
Unplug unit from power source or switch o power source.
-WITH SWITCH
Stop unit before unplugging from power source. Make sure toggle switch is set to STOP.
SINGLE SPEED REQUIREMENTS
Based on 115v blower on a 20 amp circuit
Model
Motor HP Starting
Amps
Starting
Watts
Running
Amps
Starting
Watts
EB-16 1.5 54.6 6,300 18.2 2,100
EBS-16 1/3 10.9 1,300 6.3 756
EB-18 1 48 6,000 16 1,900
EB-21 1 48 6,000 16 1,900
EB-24 1 48 6,000 16 1,900
MAXIMUM POWER CORD LENGTH
Based on 1 blower on a 20 amp circuit
Motor HP
14 gauge 12 gauge 10 gauge 8 gauge 6 gauge
EBS-16 215’ 330’ 550’ 850’ 1,350’
EB-16 60’ 95’ 150’ 240’ 380’
EB-18 45’ 65’ 115’ 190’ 300’
Page 12
Page 14
Maintenance Procedures
Although the Tempest Variable Speed Blowers are designed to eliminate most mainte­nance issues, it is imperative that the blowers be inspected before startup on each use. Please review the following list before using this product.
MAINTENANCE SCHEDULE
EVERY USE  INSPECT BLOWER FOR DAMAGE AND FIX IF ANY  TIGHTEN/REPLACE ANY LOOSE OR MISSING PARTS  INSPECT BLADE FOR NICKS/CUTS OR DAMAGE EVERY MONTH OR 10 HOURS  INSPECT & CLEAN SHROUD & GRILLS
If the blade has made contact with a hard object, and damage has occurred, please fol­low these simple instructions for removing and reinstalling the blade assembly.
BLADE REMOVAL/INSTALLATION PROCEDURES
IMPORTANT: Tempest Variable and Single Speed Electric Power Blowers feature two dierent blade to sha mount designs. When attempting to remove/install a blade to your electric blower, you will need to identify which design your blower uses. e instructions on the following pages touch on both designs individually. Using the im­ages provided, match the blade-sha design you have with the ones shown in order to decide which set of directions to follow. If you have any questions, please contact us a
1.800.346.2143
BLADE REMOVAL PROCEDURES
1. Remove the eight bolts holding the front grill in place and remove the grill. (Figure 4.1)
Page 13
Figure 4.1
Page 15
Maintenance Procedures Continued
2. Remove the three bolts from blade and remove the blade from the hub. (Figure 4.2) Remove the two bolts that secure the bushing to the hub. Put the two bolts in the threaded part of the bushing and turn evenly until bushing separates from hub.
BLADE INSTALLATION PROCEDURES
Make sure that the sha and keyway are clean and
1.
smooth before installing the bushing. Remove the hub from the new blade assembly. Put “Loc-Tite” on the screws that secure the bushing
2.
to the hub. Insert the cap screws through the clear­ance holes in the bushing and loosely place the bush­ing into the hub of the blade. Do not press the bush­ing in. Hand start the screws into the hub, turning them just enough to engage the threads in the tapped holes on the hub. e bushing should be loose in the hub. Place the hub and the bushing onto the motor sha. Insert the key into the keyway (Figure 4.3) and tighten the two bolts drawing the bushing and hub together. Slide the blade onto the bushing/hub assembly and place “Lock-Tite” on the three
3.
bolts, then insert the three bolts through the blade and turn evenly but do not tighten. Make sure blade is in line with hub then tighten bolts (Figure 4.3). Locate the blade and bushing so that the blade tips do not hit the rear grill eyelets.
Figure 4.2
Figure 4.3
NOTE:
On some models the blade and bushing may be in beyond or out away from the end of the sha up to ¼” but no further. is is necessary for proper blade clearance.
Tighten the cap screw bolts progressively with a wrench. Tighten each cap screw, par-
4.
tial turns successively until all are tight. Final tightening should be done with torque wrench with the torque set at 7.5 /lbs. for each screw. Over tightening will cause the cap screws to break or crack the blade. (Figure 4.2) Carefully turn the blade and check for clearance between the blade and shroud. Con-
5.
rm that the blade is free to rotate without hitting other parts. Reinstall the front grill and test the blower.
6.
If you have any trouble removing or installing the blade on your blower, contact the
7.
factory for assistance at 1.800.346.2143.
Page 14
Page 16
Maintenance Procedures Continued
BLADE REMOVAL PROCEDURES
Remove the eight bolts holding the front grill in
1.
place and remove the grill. (Figure 4.1, Page 13) Remove the three Allen bolts from blade/hub assem-
2.
bly. DO NOT remove the four nuts/bolts holding the two blade hub halves that secure the blade ns. (Figure 5.1)
3.
Insert bolts into adjoining threaded holes of blade/ hub assembly, hand tighten. (Figure 5.2)
4.
With Allen wrench, consecutively tighten bolt 1,2,3 half turn and repeat until blade separates from bush­ing.
BUSHING REMOVAL
Loosen Allen set screw. Insert small screw driver into bushing slot applying a little pressure to release bushing from engine sha. (Some bushings may have a set screw securing the bushing to the key on the motor sha). Be careful not to damage end of sha. (Figure 5.3)
Figure 5.1
Figure 5.2
BLADE INSTALLATION
1.
Check key. A worn key should be replaced. Make sure motor sha keyway is clean.
2.
Align bushing keyway with sha key and position bushing on sha to insure blade ns are centered between front and rear grill mounting bolts. Put blue “Loc-Tite” on bushing allen set screw and tighten.
3.
Align non-threaded holes of blade/hub assembly with threaded holes of bushing. Put lock washers on bushing bolts. Put blue “Loc-Tite” on bushing bolts. Insert through non-threaded holes of blade/hub as­sembly, hand tighten. With Allen wrench tighten bolts 1,2,3 consecutively until tight, torque to 7 pounds. (Figure 5.4)
4.
Reinstall the front grill and test the blower.
Figure 5.3
Figure 5.4
Page 15
Page 17
Trouble Shooting - VSX
Many factors can contribute to or be the sole cause of problems for electric power blow­ers. is section will identify some of these problems and provide solutions to correct them.
BLOWER FAILS TO START
MAKE SURE BLOWER IS CONNECTED TO POWER SOURCE.
IF LED DISPLAY DOES NOT LIGHT UP:
Conrm that adequate power is being supplied to blower. If power supply is adequate, DISCONNECT BLOWER FROM POWER SOURCE and check for loose or faulty wir­ing on blower electrical system and repair.
Connect blower to power source and attempt restarting, if blower still does not run, contact Tempest at 1.800.346.2143.
IF LED DISPLAY LIGHTS UP AND:
Fault Code is given, reference Fault Code Table on the next page for diagnostics.
If “---“ appears on LED, but motor does not run, DISCONNECT BLOWER FROM POWER SOURCE and check wiring between drive and motor, repair any faulty wiring.
Also check to ensure that the EPM chip is fully inserted into the socket on the top of the blower control. Connect blower to power source and attempt restarting, if blower still does not run, contact manufacturer.
BLOWER RUNS THEN CUTS OFF
Check generator rating. e VSX blower series requires minimum 3.5kw rating for maximum load operation.
Aer the blower cuts o, check the fault code reading on the LED. Reference the fault code chart on the next page.
Page 16
Page 18
Trouble Shooting - VSX
FAULT CODES
FAULT DESCRIPTION & POSSIBLE
CAUSES
JF KEYPAD FAULT: THE COM-
MUNICATION LINK BE­TWEEN THE DRIVE AND THE KEYPAD HAS BEEN LO ST.
LF LOW DC BUS VOLT-
AGE FAULT: TYPICALLY, CIRCUIT BREAKER HAS TRIPPED DUE TO EXCES­SIVE AMP DRAW.
ACTION
CHECK KEYPAD WIRING AND MAKE NECESSARY REPAIRS.
L. CHECK CIRCUIT BREAKER SIZE, RECOMMENDED SIZE FOR VSX SE­RIES IS 20 AMP. CHANGE CIRCUIT BREAKER IF TOO SMALL. LL. CHECK GENERATOR KW RATING, IF TOO SMALL, UPGRADE GENERA­TOR, OR RUN BLOWER LOWER THAN MAXIMUM BLOWER SPEED. LLL. CHECK LINE VOLTAGE AT J­BOX RECEPTACLE. LINE VOLTAGE SHOULD BE 120V, ±10%. MAKE NEC­ESSARY ADJUSTMENTS TO INSURE PROPER SUPPLY VOLTAGE. LLLL. CHECK FOR UNDERSIZED POWER SUPPLY CORD. ACCEPTABLE CORD IS 10/3 AWG X 200 FT. MAX. CHANGE CORD ACCORDINGLY.
PF CURRENT OVERLOAD
FAULT: EXCESSIVE CUR­RENT DRAW BETWEEN DRIVE AND MOTOR.
Page 17
L. CHECK FOR UNDERSIZED POWER SUPPLY CORD. ACCEPTABLE CORD IS 10/3 AWG X 200 FT. MAX. CHANGE CORD ACCORDINGLY.
Page 19
Trouble Shooting - VSX
CHANGING EPM PROGRAM CHIP
When replacing the EPM (program chip), use a ¼” nut driver to remove the opposing self tapping screws on the black cover of the VSX box. e EPM is located in the upper le corner of the white controller under a small piece of protective lm. Remove the tape and using needle nose pliers, remove the EPM and replace with new one. Replace the tape over the EPM, replace black cover and opposing screws.
BLOWER MOVEMENT OR “WALKING”
• Adjust the rubber footpads on the back of the Blower by turning them either in or out.
Adjust the side that is walking. is will help to evenly distribute the weight of the Blower to all four points of the frame
• Most Blowers will walk if not running at full speed, make sure the Blower is running at
full speed.
• Make sure the Blower is sitting at and not on small rocks or other objects.
Page 18
Page 20
Trouble Shooting - VSG
Many factors can contribute to or be the sole cause of problems for electric power blow­ers. is section will identify some of these problems and provide solutions to correct them.
MAKE SURE BLOWER IS CONNECTED TO POWER SOURCE.
IF THE “ON” AND THE “STOP” LEDS DO NOT LIGHT UP:
Conrm that adequate power is being supplied to blower. If power supply is adequate, DISCONNECT BLOWER FROM POWER SOURCE and check for loose or faulty wir­ing on blower electrical system and repair.
Connect blower to power source and attempt restarting, if blower still does not run, contact Tempest at 1.800.346.2143.
BLOWER RUNS THEN CUTS OFF:
Check that the overload indicator light is lit. If the light is lit, this means there is insu­cient voltage going to the unit. is can be caused by too long of a extension cord, faulty extension cord or low voltage from the power source. If none of the above exist, the unit may be set to draw more amperage than the power supply delivers. If this is the case, there is an adjustment inside the drive to correct the amperage draw when running at 100%. Please contact Tempest for instructions.
BLOWER SURGES WHEN RUNNING ON GENERATOR:
Check generator that it meets the proper voltage output to operate the blower.
BLOWER MOVEMENT OR “WALKING”
• Adjust the rubber footpads on the back of the Blower by turning them either in or out.
Adjust the side that is walking. is will help to evenly distribute the weight of the Blower to all four points of the frame
• Most Blowers will walk if not running at full speed, make sure the Blower is running at
full speed.
• Make sure the Blower is sitting at and not on small rocks or other objects.
Page 19
Page 21
Trouble Shooting - VSM
Many factors can contribute to or be the sole cause of problems for electric power blow­ers. is section will identify some of these problems and provide solutions to correct them.
MAKE SURE BLOWER IS CONNECTED TO POWER SOURCE.
BLOWER WILL NOT START WHEN RHEOSTAT TURNED:
Check the LED light on the drive. It should be lit when the rheostat is in the “RUN” po­sition. If not lit, conrm that adequate power is being supplied to blower. If pwer supply is adequate, DISCONNECT BLOWER FROM POWER SOURCE and check for loose or faulty wiring on blower electrical system and repair. Connect blower to power source and attempt restarting. If blower does not run, remove the drive cover and check the internal wiring connections. Check the internal fuse located on the circuit board of the drive also.
If the LED light is on and the blower will not start and all electrical connections have been checked as in the above paragraph, the VSM drive may need to be replaced.
Contact Tempest at 1.800.346.2143 for assistance.
BLOWER MOVEMENT OR “WALKING”
• Adjust the rubber footpads on the back of the Blower by turning them either in or out.
Adjust the side that is walking. is will help to evenly distribute the weight of the Blower to all four points of the frame
• Most Blowers will walk if not running at full speed, make sure the Blower is running at
full speed.
• Make sure the Blower is sitting at and not on small rocks or other objects.
Page 20
Page 22
Trouble Shooting - Single Speed
Many factors can contribute to or be the sole cause of problems for electric power blow­ers. is section will identify some of these problems and provide solutions to correct them.
BLOWER FAILS TO START:
MAKE SURE BLOWER IS CONNECTED TO POWER SOURCE.
• oroughly check the power cord. If the cord shows any signs of serious wear it may
need to be replaced before running properly.
• Many blowers are equipped with an “automatic reset.” is reset will kill power to the
blower when the unit is at risk of overheating. Let the blower cool and attempt to start it again.
• ere may be damage to the internal wiring. Have a qualied technician or electronics
specialists examine the blower circuitry and wiring and make any necessary repairs.
• If your Tempest Single Speed Blower is not running aer pursuing the steps mentioned
above, please contact us at 1.800.346.2143 or [email protected]
BLOWER MOVEMENT OR “WALKING”
• Adjust the rubber footpads on the back of the Blower by turning them either in or out.
Adjust the side that is walking. is will help to evenly distribute the weight of the Blower to all four points of the frame
• Most Blowers will walk if not running at full speed, make sure the Blower is running at
full speed.
• Make sure the Blower is sitting at and not on small rocks or other objects.
Page 21
Page 23
Notes:
Page 22
Page 24
Electric Power Blowers Exploded View - VSM & Single Speed
Page 23
Page 25
Electric Power Blowers Parts List - VSM & Single Speed
NI = Not Ill lustrated REV A
* denotes item includes necessary hardware for installation
NI* ELECTRIC MOTOR ASSEMBLY STD 360-041 360-042 360-042 600-135 600-131 600-131 600-131
NI* ELECTRIC MOTOR ASSEMBLY EP NA NA NA NA 600-132 600-132 600-132
21* FRAME 2012 600-669K 600-670K 600-672K 600-669K 600-670K 600-672K 600-674K
22* HANDLE 2012 600-677K 600-678K 600-679K 600-677K 600-678K 600-679K 600-680K
23* WIN STEP 2012 600-683K 600-684K 600-687K 600-683K 600-684K 600-687K 600-689K
24* SHROUD, RED
25* VSM DRIVE ASSEMBLY 581-085K 581-085K 581-085K NA NA NA NA
705-100
705-105 705-110
18* FRONT GRILL 600-008 600-002 600-003 600-008 600-002 600-003 600-004
19* LEG ASSEMBLY LEFT 2012 600-361K 600-350K 600-350K 600-361K 600-350K 600-350K 600-350K
20* LEG ASSEMBLY RIGHT 2012 600-362K 600-351K 600-351K 600-362K 600-351K 600-351K 600-351K
15 KEYSTOCK SQ STEEL (CUT 1.5") NA NA NA 460-062 460-062 460-062 460-062
16 FOOT TAPERED 580-006 580-006 580-006 580-006 580-006 580-006 580-006
17 SPRING ASSEMBLY 600-001 600-001 600-001 600-001 600-001 600-001 600-001
12 SPRING TORSION 300-019 300-018 300-018 300-019 300-018 300-018 300-018
13 SPRING PLUNGER W/HANDLE 300-170 300-170 300-170 300-170 300-170 300-170 300-170
14 TRIM FRONT 410-012 410-002 410-003 410-012 410-002 410-003 410-004
10 WHEEL FLAT FREE 240-008 240-012 240-012 240-008 240-012 240-012 240-012
11 BLADE ASSEMBLY (DD) (EB)
9 REAR GRILL 230-028 230-023 230-038 230-028 230-023 230-038 230-022
260-074 260-075
7 HANDLE BRACKET 220-069 220-069 220-069 220-069 220-069 220-069 220-069
8 GRIP BASIC BLOWER HANDLE 220-248 220-248 220-248 220-248 220-248 220-248 220-248
5
TAPER LOCK BUSHING
NA 160-048
2 1/4 X 1/2 FLAT SOC C/S ZINC 100-079 100-079 100-079 100-079 100-079 100-079 100-079
3 WASHER #10 HIGH COLLAR LOCK NA 120-034 120-034 NA 120-034 120-034 120-034
4 WASHER 3/8 X 2 FENDER HVY Z 120-037 120-037 120-037 120-037 120-037 120-037 120-037
Item # Description Part number Part number Part number Part number Part number Part number Part number
1 BOLT 10-24 X 1 1/4 SOC P NA 100-059 100-059 NA 100-059 100-059 100-059
VSM 16 VSM 18 VSM 21 EB16 EB18 EB21 EB24
Replacement Parts For Single Speed and VSM Electric Powered Blowers
May 2012 and Later
705-100
705-105 705-110 705-115
260-019
260-069 260-075
260-019 260-021
160-048 160-040
160-039
160-039 160-039
Page 24
Page 26
Electric Power Blowers Exploded View - VSX & VSG
Page 25
Page 27
Electric Power Blowers Parts List - VSX & VSG
NI = Not Ill lustrated REV A
* denotes item includes necessary hardware for installation
NI* ELECTRIC MOTOR ASSEMBLY STD 360-047 360-047 360-047 360-047 360-051 360-051 360-051 360-051
25 VSX OR VSG DRIVE 581-150 581-150 581-150 581-150 581-180K* 581-180K* 581-180K* 581-180K*
22* HANDLE 2012 600-677K 600-678K 600-679K 600-680K 600-677K 600-678K 600-679K 600-680K
23* WIN STEP 2012 600-683K 600-684K 600-687K 600-689K 600-683K 600-684K 600-687K 600-689K
24* SHROUD
705-101
705-106 705-111 705-116
19* LEG ASSEMBLY LEFT 2012 600-361K 600-350K 600-350K 600-350K 600-361K 600-350K 600-350K 600-350K
20* LEG ASSEMBLY RIGHT 2012 600-362K 600-351K 600-351K 600-351K 600-362K 600-351K 600-351K 600-351K
21* FRAME 2012 600-692K 600-693K 600-694K 600-695K 600-692K 600-693K 600-694K 600-695K
18* FRONT GRILL 600-008 600-002 600-003 600-004 600-008 600-002 600-003 600-004
16 FOOT TAPERED 580-006 580-006 580-006 580-006 580-006 580-006 580-006 580-006
17 SPRING ASSEMBLY 600-001 600-001 600-001 600-001 600-001 600-001 600-001 600-001
13 SPRING PLUNGER W/HANDLE 300-170 300-170 300-170 300-170 300-170 300-170 300-170 300-170
14 TRIM FRONT 410-012 410-002 410-003 410-004 410-012 410-002 410-003 410-004
15 KEYSTOCK SQ STEEL (CUT 1.5") 460-062 460-062 460-062 460-062 460-062 460-062 460-062 460-062
10 WHEEL FLAT FREE 240-008 240-012 240-012 240-012 240-008 240-012 240-012 240-012
11 BLADE ASSEMBLY
12 SPRING TORSION 300-019 300-018 300-018 300-018 300-019 300-018 300-018 300-018
260-030 260-068
7 HANDLE BRACKET 220-069 220-069 220-069 220-069 220-069 220-069 220-069 220-069
8 GRIP BASIC BLOWER HANDLE 220-248 220-248 220-248 220-248 220-248 220-248 220-248 220-248
9 REAR GRILL 230-028 230-023 230-038 230-022 230-028 230-023 230-038 230-022
3 WASHER #10 HIGH COLLAR LOCK NA NA 120-034 120-034 NA NA NA 120-034
4 WASHER 3/8 X 2 FENDER HVY Z 120-037 120-037 120-037 120-037 120-037 120-037 120-037 120-037
5
TAPER LOCK BUSHING
160-046* 160-046*
Item # Description Part number Part number Part number Part number Part number Part number Part number Part number
1 BOLT 10-24 X 1 1/4 SOC P NA NA 100-059 100-059 NA NA NA 100-059
2 1/4 X 1/2 FLAT SOC C/S ZINC 100-079 100-079 100-079 100-079 100-079 100-079 100-079 100-079
Replacement Parts For VSX and VSG Electric Powered Blowers
May 2012 and Later
VSX 16 VSX 18 VSX 21 VSX 24 VSG 16 VSG 18 VSG 21 VSG 24
705-102
705-107 705-112 705-117
260-019
260-021 260-030 260-068
260-071 260-080
160-055 160-055
160-045* 160-045*
160-045* 160-039
Page 26
Page 28
“Committed to Fireghter Safety.”
Mission Statement
Tempest Technology Corporation’s mission is the promotion of the use of air as a tool for eliminating hostile interior environments encountered by reghters, rescue teams, industrial workers, and industrial contractors worldwide.
is mission will be accomplished by identifying opportunities where Positive Pressure Ventilation and other ventilation techniques can be applied to make a work or emergency environment safer and educating manufacturers, distributors and end users through live demonstrations and professional training programs.
Tempest will continually improve and expand its existing product line to meet the needs of customers in various domestic and international markets. In order to fully utilize the strength of its resources and worldwide distribution system, Tempest will develop strategic partnerships, add complementary product lines and engage in private labeling agreements with other manufacturers.
www.tempest-edge.com