Tempdrop TD1 Users Manual

Fertility Tracking Wearable
Table of contents
Clarifications and restrictions Using Tempdrop Maintenance Troubleshooting Safety and certification
4-6
7-11
12-13 14-15 16-19
What is included?
1 Tempdrop Sensor 1 Elastic Armband 1 User Manual 1 Carrying Pouch
Bluetooth connectivity & radiation
Putting your safety first, Tempdrop will not transmit any data while you wear it. Instead, Tempdrop will only transmit data after you manually initiate a data sync.
3
3
Clarifications and restrictions
Tempdrop is a personalized user-specific thermometer that learns how each woman’s minute, daily temperature variations correlate with her specific hormonal fluctuations throughout the ovulatory cycle. It is intended for use with fertility apps or other approaches to fertility monitoring and allows daily, hassle-free, and accurate tracking of your sleeping temperature.
Powered by our patented Active Temperature-Noise Cancellation™ (ATNC) technology, Tempdrop’s accuracy is achieved using multiple sensors and an algorithm developed by top engineers and doctors.
When using sympto-thermal based methods to track fertility
and predict ovulation, reliability depends on daily and accurate input of sleeping temperature (also known as BBT). The accuracy of Tempdrop’s data allows you to identify recurring temperature patterns up to 5 days before ovulation.
Important notice
Alcohol consumption, medications, and various medical conditions may alter your sleeping temperature been drinking alcohol a few hours before sleeping, make a note on that in your fertility app or notebook and examine the eect on your sleeping temperature. We advise you to track your sleeping temperature with Tempdrop for two full ovulatory cycles so you can clearly identify the temperature shift and pattern before and after your ovulation day.
. If you have
4
5
For your information
• Tempdrop is not a medical device
• Tempdrop is not a waterproof or water-resistant product
• Do not drop the Tempdrop sensor
• Ideal operating temperatures are 32-104°F (0-40°C)
• Extreme heat or cold may damage Tempdrop or its
accessories
• Keep Tempdrop away from sources of heat and fire
• Do not expose your Tempdrop to direct sunlight (such as
on a car dashboard) for prolonged periods
• Tempdrop is not for children!
No HumidityNot for children
Wearing your Tempdrop for the first time
Snap the Tempdrop sensor into the armband. The sensor should be worn underneath your armpit with the tip of the sensor pointing towards your elbow as illustrated below:
6
7
Slide the metal latch along the grooves to change the size of the armband. This is needed only until you find your ‘sweetspot’ where the armband is the most comfortable. The armband’s elasticity makes it easy to slide it up your arm.
It is best to wear Tempdrop on the same arm every time
Smaller
Larger
8
The armband should
hold the sensor securely in place should only be tight enough to stay on during sleep without sliding towards your elbow by the morning, but no tighter.
The armband
Installing Tempdrop’s application
Tempdrop’s mobile application is needed to sync the data from the sensor with our algorithm server and to display the calculated temperature.
Install Tempdrop’s app on Google Play (Android) or Apple’s App Store. If you are having difficulty finding it, visit our website for help.
First-Time Users:
Sign up with a valid email address and username. These
details are linked to your Tempdrop history data. Keep them to yourself!
We will not send you any spam emails or sell your information.
9
Using Tempdrop
1. Every night, before you go to sleep, press the pink, drop­shaped button for 3-5 seconds until the button is blinking green and put on Tempdrop as instructed above.
2. Attention!
Do not wear Tempdrop when it is in the process of data
syncing. If the sensor gets stuck while data syncing and won’t stop rapidly blinking, first terminate the process by pressing the button for 3-5 seconds. If the sensor still doesn’t stop, turn off your smartphone’s Bluetooth to dis­connect the sensor.
3. After you wake up, take o Tempdrop and place it next to your smartphone for optimal data sync. Make sure that
the Tempdrop app is open and Bluetooth is enabled. Press Tempdrop’s button for 3-5 seconds. It will blink slowly at first. When the button on Tempdrop starts blinking rapidly and Tempdrop’s logo starts spinning in the app, the sync is taking place.
4. Wait until the syncing process is done and the blinking stops (it should take 2-4 minutes for an 8-hour sleep).
5. Your calculated temperature will be displayed on the Tempdrop app.
6. Please refer to the troubleshooting guide on this manual if you have any issues.
10
11
Cleaning and maintenance
The Sensor - You can use alcohol wipes or a clean, soft cloth to clean the Tempdrop sensor. The Armband - Make sure you remove the sensor from its frame. You may wash the textile armband and the plastic frame with lukewarm water and some laundry soap. Make sure the armband is completely dry before inserting the Tempdrop sensor.
Replacing the battery
If you have been using Tempdrop every day for at least six months and it has stopped working, you
its battery. In order to replace Tempdrop’s battery, you will need to separate the top and bottom plastic shells. Please visit our website for detailed video instructions.
12
may need to replace
Specifications
Dimensions: 45 x 32 x 10.5 mm Weight: 7 grams Armband Circumference Length: min - max = 6’’ - 12’’/15 - 30 cm Power Source and Connectivity: CR2032 Coin Cell Battery
Wireless Low Energy Bluetooth. Sensors: Temperature (multichannel), Tri-axis Acceleration.
Important notice
In the event of an equipment malfunction, all repairs must be performed either by Tempdrop or by an authorized agent. It is the customer’s responsibility to report the need for
service to Tempdrop or to one of its authorized agents. For
service information, contact Tempdrop customer support: support@temp-drop.com
13
Troubleshooting - Issues related to data sync
Issue 1
The syncing process ends immediately and a “No data on device” message is displayed on the app even though you think that the sensor has data on it that wasn’t synced.
Issue 2
The sensor is blinking rapidly and seems “stuck” in data sync mode but Tempdrop’s logo in the app is not spinning. One of these messages may be displayed: “No Data on the device, starting to record” “Error oc­curred during the process. Try again”
Solution
Restart the data sync process by pressing the button for 3-5 seconds. If the problem persists, force close the app (remove from memory), restart the app, and then restart the data-sync process.
14
Solution
Press Tempdrop’s button for 3-5 seconds to terminate the data sync process and press it again to restart the syncing
process. Don’t worry, if the sensor contains data, it will be
uploaded on the next successful sync. If the problem persists, force close the app, start the app, and restart the data sync process.
15
Safety information for the battery
This product contains an internal replicable Li-On battery (CR2032 Lithium coin cell battery). In exceptional circumstances, batteries may leak uids that can cause a chemical burn injury or ruin the product.
To avoid battery leakage:
• Insert batteries as indicated inside the battery compartment.
• Dispose of batteries safely. Do not dispose of this product in a re.
The batteries inside may explode or leak.
• Never short-circuit the battery terminals.
• Use only batteries of the same or equivalent type, as recommended.
• Do not charge non-rechargeable batteries.
This symbol on the product or on its packaging indicates that this product should not be treated as household waste. Instead it should be handed over to the applicable collection point for the recycling of electrical and electronic equipment. By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health. The recycling of these materials will help to conserve natural
16
resources. For more detailed information about the recycling of this product
please contact: support@temp-drop.com.
Warning! Choking hazard
Store the product out of reach of children, infants, and pets. Tempdrop is not a toy – never allow children to play with the sensor and/or armband as they may cause child suocation. Always store the product out of reach of children.
Certif ication
Tempdrop was designed and tested to meet the applicable standards for Electrical Safety, Electromagnetic Compatibility, Sustainability and other regulatory requirements.
For questions related to the regulation compliance of this product, contact:
Tem pdrop Ltd.
20 Hata’as st. Bell House, PO Box 209 Kfar Saba, 44425, Israel
contact@temp-drop.com www.temp-drop.com
17
,
Federal Communications Commission (FCC) Statement Labeling Requirements (FCC 15.19)
This device complies with Part 15 of FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Radio Frequency Interference (RFI) (FCC 15.105)
This equipment has been tested and found to comply with the limits for
Class B digital devices pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a residential environment. This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instruction manual, may cause harmful interference to radio
communications. However, there is no guarantee that interference will
not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment o and on, the interference by one or more of the following measures:
the user is encouraged to try and correct
18
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and the receiver.
• Connect the equipment into an outlet on a circuit dierent from that to
which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
Modif ications (FCC 15.21)
Changes or modications to this equipment not expressly approved by Tempdrop Ltd may void the user’s authority to operate this equipment.
RF Exposure info( FCC 2.1093)
The device meets the exemption from the routine evaluation limits in
section 4.3.1 of KDB 447498 D01. Users can obtain information on RF exposure and compliance in the FCC website.
FCC ID: 2AMAS-TD1
Made In Israel
19
Contact Us
For any inquiry, help, or troubleshooting, email us at: support@temp-drop.com
You may also visit the FAQ page on our website: www.temp-drop.com
Loading...