TEMA TELECOMUNICAZIONI S.r.l.
Telecommunications - Electronics
AA-10
for connection with analog trunk
TECHNICAL MANUAL – INSTALLATION
AA-10 System manual SW Version 9
PRELIMINARY DOCUMENTATION
Made in Italy by TEMA TELECOMUNICAZIONI S.r.l.
Recommendations
1. Use only original spare parts and consumables supplied by Tema Telecomunicazioni Srl for this equipment. The company shall not be held responsible for any damage caused by the use of materials that they have not supplied.
2. The device has been carefully manufactured and tested. In any case, the product is not recommended for use in situations in
which incorrect operating may result in damage to persons and/or property.
3. We recommend that you carefully read all this manual before starting to use the device.
4. Do not expose the device to sunlight and protect it from sources of heat, dust, humidity and chemical agents.
5. This manual is the property of Tema Telecomunicazioni Srl and any duplication and reproduction even partial, as well as storage on any type of media is forbidden without written permission from Tema Telecomunicazioni Srl.
Revision Date Revision reason Prepared Checked/Approved
5 10/05/2016 Update GM FL
MAS-AA10-REV05EN Page 1 of 12
Page 2
TEMA TELECOMUNICAZIONI SRL Doorphone PBX interface AA-10
DICHIARAZIONE DI CONFORMITÀ CE
La sottoscritta società TEMA TELECOMUNICAZIONI SRL con sede in Via C. Girardengo, 1/4 - 20161 MILANO
dichiara che il prodotto Interfaccia Citotelefonica – Door Phone Pbx Interface Codici AA-10, AA-11, COM123, COM124 è stato costruito in conformità alle seguenti normative: SICUREZZA EN 60950 EMC EN 55022
EN 55024 EN 61000-6-1 EN 61000-6-3
TERMINALE DI TBR 21 (1998) – Terminal Equipment (TE); Attachment TELECOMUNICAZIONE requirements for pan-European approval for connection to the analogue Public Switched Telephone Networks (PSTNs) of TE (excluding TE supporting the voice telephony service) in which network addressing, if provided, is by means of Dual Tone Multi Frequency (DTMF) signalling.
Inoltre il prodotto sopra menzionato soddisfa i requisiti essenziali delle seguenti direttive:
Direttiva LVD 73/23/EEC (Low Voltage Directive)
Direttiva EMC 89/336/EEC – 92/31/ECC
Direttiva 99/05/EC per apparati di Radio e Telecomunicazioni
MILANO, 27 Maggio 2005 TEMA TELECOMUNICAZIONI SRL Felice Lamanna Amministratore
DECLARATION OF CONFORMITY CE
MAS-AA10-REV05EN Page 2 of 12
Page 3
TEMA TELECOMUNICAZIONI SRL Doorphone PBX interface AA-10
I. IMPORTANT INFORMATIONS REGARDING THE RECOVERY AND RECYCLING OF THIS
ELECTRONIC DEVICE
The crossed-out wheeled bin symbol below indicates that this electronic equipment is intended to be disposed in a separate collection and not in an unsorted municipal waste, in order to provide for the treatment of WEEE (Waste Electrical and Electronic Equipment) using best available recovery and recycling techniques. Specific treatment for WEEE is indispensable in order to avoid the dispersion of pollutants and other hazardous substances into the waste stream, while recycling leads to reduction of disposal of waste and the negative impacts on environment and human health. That is, priority is given to reuse of WEEE in its components, subassemblies and consumables. As the final holder, the user has an important role in contributing to reuse, recycling and other forms of recovery of WEEE and is responsible to return this waste in the collection facilities set up by EC Member Stases and to fulfill other duties in compliance with Directive 2002/96/EC and local laws.
MAS-AA10-REV05EN Page 3 of 12
Page 4
TEMA TELECOMUNICAZIONI SRL Doorphone PBX interface AA-10
1. OVERVIEW OF AA-10 INTERFACE
The AA-10 doorphone-PBX interface is designed to manage the external doorbell of the vast majority of door systems (4 or 5 wires) through an analog trunk of the PBX. When a visitor pushes the doorbell, AA-10 makes a call to the trunk. This will be typically managed by the PBX operator. Then the operator can speak with the visitor at the doorbell and then open the door with a DTMF command. AA-10 is equipped with a relay to open the door, plus two auxiliary relays (e.g. to turn on external lights or to control other devices). Many commands can be given through DTMF, such as: start voice communication with the external doorbell, electric door or gate opening, (de)activation of aux relay 1, (de)activation of aux relay 2 etc. The device parameters can be programmed through the phone as well.
2. MAIN CHARACTERISTICS
The main features of AA-10 are:
Connection to most doorbell systems (4 or 5 wires)
DIN rail mount, fitted with 1 open-door relay plus 2 auxiliary relays
Configurable activation time and number of pulses of the open-door relay
Programmable using a standard DTMF phone
Non-volatile parameter memory (keeps settings even when not powered)
Power and status LEDs
3. GENERAL FUNCTIONS
When the external doorphone button is pushed, the device generates automatically a call to the PBX. As soon as AA-10 detects the operator answer, it stops the ring current and waits for DTMF commands. In the meanwhile it beeps every 2 seconds. In the “normal” mode the operator must dial “1” to activate the communication with the external doorphone. Once the voice connection is established, the operator can activate the open-door relay dialing “2”.
Hanging up, AA-10 returns idle and ready for a new access request. It is also possible to connect with the external doorphone dialing the suitable digits (dependent on the PBX configuration). It will beep every 2 seconds and connect the caller to the doorphone when “1” is dialed. This feature is useful if there is the need to activate a voice connection without an explicit request from the outside. For example when the presence of a guest is detected using a camera.
AA-10 releases the call and returns idle if the operator does not answer within 45 seconds. If the operator answers to a call from AA-10 not during the working hours and does not want to open the door nor speak with the guest, he can simply hang up after hearing the AA-10 tone. An the external doorphone, it will look like if nobody were present inside.
Calling AA-10 opens the possibility to use its additional features, in particular to activate the two auxiliary relays according to their programming. They can be used to open additional doors or gates, as well as to turn on a lamp when it’s dark.
By combining the AA-10 relays with other appliances, it is possible for example to activate the heating/cooling system.
It is possible to set AA-10 to work in “autoconnect” mode. In this mode, AA-10 will work in the same way as described above. The difference is that when the operator answer to the AA-10 call, the system immediately connect the visitor with him (no “1” digit required, as the “normal” mode).
MAS-AA10-REV05EN Page 4 of 12
Page 5
TEMA TELECOMUNICAZIONI SRL Doorphone PBX interface AA-10
- +
- + - +
4. GENERAL DESCRIPTION
4.1. Front view
AA-10
Door Phone Interface - Trunk
Line
Top view
Screw terminals 1 and 2 are for connecting Aux 1 relay (without common contacts)
Screw terminals 3 and 4 are for connecting Aux 2 relay (without common contacts)
Screw terminal 5 is for connecting one wire of the electric door lock (AA-10 will connect this
point to screw terminal 9 in order to open the door); the other wire has to be connected to the doorphone power
Screw terminal 6 (AA-10 audio input) is for connecting the doorphone microphone
Screw terminal 7 (AA-10 audio output) is for connecting the doorphone speaker
Screw terminal 8 is for connecting the doorphone button
Screw terminal 9 is for connecting the doorphone microphone and speaker common signal
Screw terminals 16-17 are for connecting the PBX trunk line
4.2. Volume adjustment
The two trimmers on the top side (see picture below) adjust the microphone and speaker volume.
Mic = external doorphone microphone sensitivity
Alt = external doorphone speaker sensitivity
Bal Mic Alt
Before proceeding to the installation it is advisable to set the trimmers to half range. Then adjust the Mic trimmer to obtain a good listening volume at the operator phone, then adjust the Alt trimmer to obtain a good listening volume at the external doorphone.
In the case that hisses are present (Larsen effect) try to reduce the Mic/Alt audio level by trimmers. Larsen effect depends on the external doorphone acoustic condition. It might be necessary to adjust the trimmers before installing AA-10 on the DIN rail, depending on the position where it will be installed. If it is the case, connect AA-10 and adjust the trimmers before mounting it on the rail.
Bal Mic Alt
MAS-AA10-REV05EN Page 5 of 12
Page 6
TEMA TELECOMUNICAZIONI SRL Doorphone PBX interface AA-10
Line Line
5. INSTALLATION
5.1. Connection examples
In the following, examples of connection with some brands of doorphones are presented. Find your model and connect it as indicated.
Connection to
“ELVOX” doorphone
AA-10
Door Phone Interface - Trunk
Connection to
AA-10
Door Phone Interface - Trunk
MAS-AA10-REV05EN Page 6 of 12
“URMET” doorphone
Page 7
TEMA TELECOMUNICAZIONI SRL Doorphone PBX interface AA-10
Line Line
Connection to
“TERRANEO” doorphone
AA-10
Door Phone Interface - Trunk
Connection to
“BPT” doorphone
AA-10
Door Phone Interface - Trunk
MAS-AA10-REV05EN Page 7 of 12
Page 8
TEMA TELECOMUNICAZIONI SRL Doorphone PBX interface AA-10
Please note the
additional resistor
AA-11
Door Phone Interface - Extension
Connection to
“FARFISA”
doorphone
Please note the
additional resistor
AA-11
Door Phone Interface - Extension
Connection to
“COMELIT”
doorphone
MAS-AA10-REV05EN Page 8 of 12
Page 9
TEMA TELECOMUNICAZIONI SRL Doorphone PBX interface AA-10
6. PARTS COMPRISING THE SYSTEM (PACKING LIST)
AA-10 is shipped with a DIN rail segment, two screws and this manual.
7. TECHNICAL SPECIFICATIONS
Power 12VAC or 18VDC Current consumption 180 mA Operating temperature 0˚C-45˚C Humidity 95% non-condensing Mount DIN rail Size and weight H90 x W52 x D60 mm, 180 gr Doorlock relay max load
24VDC / 5A – (250VAC / 6A relay specification) WARNING: this relay has a pole in common with screw terminal 5, it cannot drive loads connected to powerline
Auxiliary relay max load 24VDC / 1A – (120VAC / 1A relay specification)
WARNING: they cannot drive powerline loads Phone line connection Twisted wire for connection to PBX trunk Line impedance, voltage and current 600 Ω, 48 VDC when idle, 25mA max. off-hook Max line loop resistance 800 Ω Ring generator 65 V
40 V
, 25Hz on open circuit,
RMS
, 25Hz on 3 REN (400 Ω)
RMS
8. OPERATING COMMANDS
These are the commands available when the device calls the operator. It is always possible to reach the device (from a PBX extension) to issue the commands or configure AA-10. The commands are available only after the call is answered.
To enter command mode: - reach AA-10 from the PBX
- dial “1” (only for “normal” mode, not for “autoconnect”)
Digit Command Description
2 3
4 5 6 7
##
Activate door lock relay Activate AUX1 relay Used for example to turn on lights
Activate AUX2 relay Used for example to turn on lights De-activate AUX1 relay Only in steady mode De-activate AUX2 relay Only in steady mode De-activate AUX1 and AUX2 relay Only in steady mode Enter programming mode Described in the following
If a digit is dialed other than those listed, three high-pitch tones are emitted.
8.1. Front panel LEDs Green LED “AL”
Red LED “R”
Lit when the device is powered Reports the device status
Off AA-10 idle Blinking AA-10 active, waiting for DTMF commands / Ring generator Steady on AA-10 active, conversation with doorphone or programming
Opens the electric lock of any door or gate that requires to close a contact for a short time
MAS-AA10-REV05EN Page 9 of 12
Page 10
TEMA TELECOMUNICAZIONI SRL Doorphone PBX interface AA-10
8.2. Table of programming parameters
The table below lists all the programming parameters for AA-10. The parameters are stored in a non-volatile memory and are not lost even in case of loss of power.
To enter programming mode:
“Normal” mode
- reach AA-10 from the PBX
- dial “1 # #”
“Autoconnect” mode
- reach AA-10 from the PBX
- dial “# #”
Digit Parameter name Description
Range = allowed values
Set the Ring frequency ( 25 or 50 Hz). Range: max 1 digit
1 n
Ring Frequency n = 0, Ring 25 Hz n = 1, Ring 50 Hz
Set the Ring cadence: normal (1 second ring, 4 seconds pause) or fast (1 second ring, 2 seconds pause). Range: max 1 digit
Set the max time in seconds during AA-10 waits for operator answer . Range: max 1 digit
2 n
3 n
Ring Cadence n = 0, 1 sec / 4 sec n = 1, 1 sec / 2 sec Time out for answer n = 0, 30 sec n = 1, 45 sec n = 2, 60 sec n = 3, 90 sec
The door lock relay is activated with one or more consecutive pulses. Set “n” for your needings. Range: max 1 digit
4 n
Door lock mode n = 1, pulse once n = 2, pulses twice n = 3, pulses 3 times
Relay AUX1 is activated with a pulse or steadily closed (until it is commanded to de-activate). Set “n” for your needings. Range: max 1 digit Relay AUX2 is activated with a pulse or steadily closed (until it is commanded to de-activate). Set “n” for your needings. Range: max 1 digit Duration of the pulse (for all relays). Note: the door-lock relay is always subjected to this setting, the AUX relays only if programmed in pulse mode. Range: max 1 digit
Operational mode settings. In the “normal” mode the operator must dial “1” to activate the communication with the external doorphone. Otherwise in “autoconnect” mode AA-10 will immediately connect the visitor with the operator (no “1” digit required). Range: max 1 digit WARNING: issue this command only if you want to reset all values to the factory default, losing your settings.
This command acts without asking any confirmation: use it with care!
5 n
6 n
7 n
9 n
8
AUX1 relay mode n = 1, pulse once n = 2, steady
AUX2 relay mode n = 1, pulse once n = 2, steady
Relay pulse duration n = 1, 0.25 sec n = 2, 0.50 sec n = 3, 1.00 sec
Operational mode n = 1, “Normal” n = 2, “Autoconnect”
Reset all values to the factory default
Default Your setting
0
(25 Hertz)
0
(1/4 sec)
1
(45 sec)
2
(2 pulses)
1
(1 pulse)
1
(1 pulse)
1
(0.25 sec)
1
(normal)
- -
For example, if you want that the door-lock is activated twice: reach AA-10 from the PBX, dial 1## to enter programming mode, dial 42 to set the door lock mode parameter, then hang up. After that, whenever the command 2 is dialed the door-lock relay will be closed twice in succession.
MAS-AA10-REV05EN Page 10 of 12
Page 11
TEMA TELECOMUNICAZIONI SRL Doorphone PBX interface AA-10
REMARKS
MAS-AA10-REV05EN Page 11 of 12
Page 12
TEMA TELECOMUNICAZIONI SRL Doorphone PBX interface AA-10
REMARKS
MAS-AA10-REV05EN Page 12 of 12