Wiring Guidelines for Warm Home- Single Family Dwellings Version V3.0WH
one connection, endless possibilities.
For years, TELUS has been providing excellence through ongoing development of existing and
future products and services for our community. As part of the TELUS Future Friendly Home, we
would like to introduce you to our Warm Home. To enjoy the benefits of a Warm Home it does not
have to be expensive, time-consuming, or complicated.
The TELUS Warm Home Program works along with the TELUS Home Solutions Partner Program to
help residential builders and developers provide premium telecommunications solutions to their
homebuyers while raising the development’s profile through carefully planned marketing. The Warm
Home enables the delivery of TELUS services to the homeowner at the time of move in, allowing
the homeowner to focus more on other pressing matters. These services span across three
primary types of media: telephone, high-speed internet access, and television. With such services
available at consumers’ fingertips almost immediately, they’ll have an extra incentive to confirm their
purchase.
This document provides guidelines and recommendations for pre-wiring new homes with Ethernet
cables (Cat 5e) during the construction stage, prior to the installation of drywall. The guidelines are
best used when combined with the TELUS Hub, where all telecommunications cabling comes
together in the home.
As technology continues to evolve, so should the cabling systems to support homeowners’
changing needs. TELUS recommends an integrated end-to-end solution for all category 5e wiring
cabling by fully trained and certified electricians and wiring contractors.. And to make residential
development projects as straightforward as possible, TELUS will continue to make changes to this
document to ensure alignment with Residential Cabling Standards and CSA T525.
For more information about the Warm Home Program, and how we can help you differentiate a
residential development project in your community, please call us today at 1-866-844-1544 or visit
our website:
http://www.telus.com/mybuilding
TELUS Communications Inc. (c) 2006-9-22 Page 2
Page 3
Wiring Guidelines for Warm Home- Single Family Dwellings Version V3.0WH
TABLE OF CONTENTS
1. Terms and Conditions of Use...................................................................................................4
2. General Information..................................................................................................................5
2.1 Definition Of Terms............................................................................................................6
3. Quick Summary of Key Points..................................................................................................7
3.1 Routing Cables [ see Section 4.4 for details ] ...........................................................7
14. Appendix F: Industry standards..............................................................................................33
TELUS Communications Inc. (c) 2006-9-22 Page 3
Page 4
Wiring Guidelines for Warm Home- Single Family Dwellings Version V3.0WH
1. Terms and Conditions of Use
(a) Any installation of premise wire shall be in accordance with the laws, rules, regulations, technical standards and
(b) The prewiring of a premise will have an immediate impact on the service to the premise as well it could affect the
(c) This document makes references to and summaries of the rules as provided in the Canadian Electrical Code
(d) The CEC and the Provincial or Municipal Electrical Inspection Branch may require a permit prior to any prewiring,
(e) While TELUS uses reasonable efforts to include accurate and up-to-date information in this Document your use of
(f) TELUS shall not be liable to the user, or any other person, for damages or loss of any kind or nature, including but
(g) You hereby agree that you shall not use any information contained in this Document in any claims, proceedings,
codes in effect at the time of installation, whether federal or provincial.
network system of TELUS. As a result TELUS advises that any design, installation and wiring is to be carried out
by a trained telecommunication technician. All telecommunications technicians are to be trained and certified by
the manufacturer and supplier of the product or equipment to be installed.
(CEC). The reference and summaries of these rules are provided for brevity and convenience. Prior to any
design, installation or prewiring of a premise, every trained technician is to be familiar with the CEC.
adding to, or rearranging the communications and data interior wiring. They may also require that the work be
inspected upon completion. Contact your local (Provincial or Municipal) Electrical Inspection Branch for further
information regarding these requirements.
If outlets are to be located in exterior walls (or walls between suites) obtain advice on maintaining the integrity of
the vapour barrier or fire-rated wall.
this Document is at your risk. Changes or updates to the contents of this Document may occur without notice to
you.
not limited to injury or death resulting from the user’s or any other person’s unfamiliarity with the CEC, or any other
laws or regulations applicable to prewiring or the installation of wires or cables, or for reliance by the user or any
other person on the matters contained in this document.
suits or actions against TELUS, its suppliers or affiliates. You may not post, publish, reproduce, transmit or
otherwise distribute information or material from this document: (a) constituting or encouraging conduct that would
constitute a criminal offence or give rise to civil liability; (b) which is protected by copyright, or other intellectual
property right or derivative works thereof, without obtaining permission of the copyright holder; (c) otherwise use
this Document in a way that is contrary to law or which would adversely impact use of this Document by other
users including the posting or transmitting of other information.
(h) Neither TELUS, its suppliers, affiliates nor any other party involved in creating, producing, or delivering the
(i) You agree to defend, indemnify and hold TELUS, its suppliers and affiliates harmless from any and all liabilities,
(j) TELUS' failure to insist upon or enforce strict performance of any provision of these Terms and Conditions shall not
(k) By using this document, you agree that these Terms and Conditions shall be governed by the laws of the province
Document is liable for any direct, indirect, incidental, special, consequential, punitive or other damages whatsoever
including business interruption, loss of use, data, information, profits (regardless of the form of action, including but
not limited to contract, negligence or other tortious act) arising out of or in connection with your use of the
Document even if TELUS has been advised of or foresees the possibility of any damages occurring. Without
limiting the foregoing, everything in the Document is provided to you "AS IS" WITHOUT REPRESENTATION,
WARRANTY OR CONDITION OF ANY KIND, EITHER EXPRESS, IMPLIED, OR STATUTORY INCLUDING, BUT
NOT LIMITED TO, IMPLIED REPRESENTATIONS, WARRANTIES OR CONDITIONS OF MERCHANTABILITY,
FITNESS FOR A PARTICULAR PURPOSE, DURABILITY, TITLE, OR NON-INFRINGEMENT OF INTELLECTUAL
PROPERTY RIGHTS.
costs and expenses, including reasonable legal fees related to any violation of these Terms and Conditions by you,
or in connection with your use of this Document or with the placement or transmission of any message or
information from the Document by you.
be construed as a waiver of any provision or rights contained in these Terms and Conditions.
of British Columbia and the federal laws of Canada applicable therein and you agree to be bound by the laws of
these jurisdictions.
TELUS Communications Inc. (c) 2006-9-22 Page 4
Page 5
Wiring Guidelines for Warm Home- Single Family Dwellings Version V3.0WH
2. General Information
Purpose of guide
This guide is intended for use in new construction, additions and remodeled single dwellings for
telephone, TELUS multimedia services, broadband Internet or home networking. This guide
specifically applies to wood frame residences.
What you are responsible for
You are responsible for:
(a) correcting any service difficulty that the installation or prewiring creates and which harms the
telecommunications network;
(b) paying a service charge when TELUS makes a repair visit to your premises in order to remedy
problems resulting from wiring that has been improperly installed or maintained.
Description of prewiring
Prewiring is a method of installing communications and data cabling such that it is concealed within
the interior partition walls of your home. Prewiring is done at the framing (or hollow frame) stage at
the same time as the electrical wiring, and before the application of insulation, drywall, and vapour
barrier. Once the walls have been surfaced, existing wiring cannot be removed or replaced without
disturbing the wall.
TELUS Communications Inc. (c) 2006-9-22 Page 5
Page 6
Wiring Guidelines for Warm Home- Single Family Dwellings Version V3.0WH
2.1 Definition Of Terms
1. BIX – means a block or strip into which conductors from a network cable are punched (eg.
Belden/CDT IDC).
2. Cat-5e – means commonly and readily available standard network cable.
3. DD, Distribution Device – means one or any combination of the following: cross-connect;
router; WAP; switch; or ADSL modem.
4. 8-pin Modular Jack – means a standard socket or jack found within a multimedia outlet (often
called RJ-45).
5. IDC – means an Insulation Displacement Connector being a type of wire connection device in
which the wire is "punched down" into a double metal holder and as a result, the metal holders
strip the insulation away from the wire, thus causing the electrical connection to be made.
6. Inside wire – means the wiring that is under the responsibility and control of the customer.
7. MO, Multimedia Outlet – means a wall mounted or flush mounted unit that may house a
number of sockets or jacks for connecting up Cable-TV, telephone or data network devices.
8. NIB – means Network Interface Box often containing Protector, POTS Splitter, etc.
9. OC, Outlet Cable – means a cable run that originates from the DD and terminates in a room at
a Multimedia Outlet (MO).
10. Set Run – a run of standard Cat-5e cable comprising a group of eight wires or four pairs, each
wire corresponds to a pin on the 8-pin modular jack.
11. CCP/CCB – customer connection point or block.
12. PC – a personal computer.
TELUS Communications Inc. (c) 2006-9-22 Page 6
Page 7
Wiring Guidelines for Warm Home- Single Family Dwellings Version V3.0WH
3. Quick Summary of Key Points
A MUST READ FOR CONTRACTORS
3.1 Routing Cables [ see Section 4.4 for details ]
3 individual Cat-5e runs, in 1" conduit preferred, 90m maximum length.
3do not run cables near power, light fixtures, transformers, fluorescent lighting.
3 do not bend cable sharply - observe minimum bend radii of cable, do not crimp,
pinch or stretch
3 install a single unbroken length between outlet and Distribution Device (DD) which is
located at a centralized location, ie. Star Wiring Topology, no daisy chaining, no splicing of
3.2 Outlet Installation [ Section 5.4 ]
cable sections.
3 room outlets include a single 8-Pin modular jack (RJ-45) for TELUS TV or a double
modular jack (RJ-11 & RJ-45) for Tel/Data.
3minimum install two outlets per room.3
minimum install one outlet adjacent to each Cable-TV outlet.
3terminate all 8 conductors in the outlet cable to the jack according to TIA/EIA-568-A
standard.
3.3 Central Distribution Location / DD [ Section 6 ]
3 all installed runs of outlet cable must be terminated at a centralized location that will
allow placement of a cross connect, switch/router and programmable equipment. This is
the Distribution Device (DD).
3 18" x 18" (minimum) space REQUIRED in closet/storage room at reasonable
working height (48") for cable run terminations, and for the central distribution
location ( ie. the DD).
31 x duplex 15A unswitched power receptacle dedicated to TELUS equipment
and installed next to panel or within the reserved space. [ Section 6.1 ]
3 grounding mandatory if metal cabinet installed [ Section 6.1 ]
panel
3 locate your DD panel/cabinet no closer than 12" (30cm) to a power distribution
runs, with MO location id (e.g. MBR01) and type of service on each if known.
3.4 TELUS Media Hub Installation Notes [ Section 11 ]
TELUS Communications Inc. (c) 2006-9-22 Page 7
3 complete the Label on the inside of the DD Panel cover by identifying the outlet cable
Page 8
Wiring Guidelines for Warm Home- Single Family Dwellings Version V3.0WH
4. Planning Multimedia Outlet Locations and Cable Routing
4.1 Introduction
To enable your home for enhanced systems, TELUS multimedia services, or, as a
smart home, all installed runs of outlet cable must be terminated at a centralized location
that will allow placement of a cross connect, switch/router and programmable equipment
that your system requires. This centralized location is identified by the Distribution Device
(DD) in most diagrams (see Diagram 1, 2 & 3). A prewired cable run to the network
interface box (NIB) from the centralized location or DD will also be required.
When selecting Multimedia Outlet (MO) locations, select those that suit both your present
and future needs. TELUS suggests you consider a minimum of two (2) outlets in each of
the areas shown here in Diagram 3. A separate cable run will be required for each service
or device at each outlet. For example, if the outlet contains two sockets, one for telephony
and one for Internet service, then two sets of four-pair cable may need to be run to this
outlet. For rooms designated as likely candidates for the location of entertainment or
multimedia equipment (e.g. living room, family room, home office, home theatre room or
den), additional wall outlets should be allocated.
It is not necessary to have a communications and data device connected at every prewired
location, however, by planning ahead you reduce the cost of future outlet installations.
Unsightly surface wire, additional installation time and inflexibility of device arrangements
are consequences of not planning. Adequate wiring will give customers flexibility in
arranging their telephone, second line, FAX lines, and multimedia services such as TELUS
PureRadio or networked audio devices.
Please refer to Form P546 (BC) or P630 (AB) for connection to TELUS service and owner /
developer‘s support and housing requirements.
Wiring standards should also be considered to accommodate for tomorrow’s
communication technologies. Security wiring and cablevision wire should also be planned
at this time. For details on wiring standards please see Section 5 - Wire/Cable and
Hardware.
TELUS must be contacted when the pathway is in place to install the service entrance wire
and the demarcation block.
4.2 Outlet Locations - Recommendations and Best Practices
Suggestions for locating outlets can be found in Diagram 3.
In each room, locate outlets as follows:
1) to allow two per room minimum, at least one near the Television and one for the PC
or telephone;
2) on walls that make up a corner where Television or PC might be located;
3) to prevent cross-room or cross doorway cable runs – see Diagram 3; and
4) to suit present and future needs, e.g. TELUS multimedia services use in the
kitchen.
TELUS Communications Inc. (c) 2006-9-22 Page 8
Page 9
Wiring Guidelines for Warm Home- Single Family Dwellings Version V3.0WH
TELUS Communications Inc. (c) 2006-9-22 Page 9
Page 10
Wiring Guidelines for Warm Home- Single Family Dwellings Version V3.0WH
Courtesy of BICSI®
Diagram 2: Typical Residential: LOGICAL VIEW
TELUS Communications Inc. (c) 2006-9-22 Page 10
Page 11
Wiring Guidelines for Warm Home- Single Family Dwellings Version V3.0WH
Courtesy of BICSI® / Modified by TELUS
Diagram 3: Typical Residential Premises Cabling System (Physical View)
4.3 Other Considerations For New Homes
Install a standard electrical outlet box (300 mm/12 in to floor) to a stud at each location that
a computer, television, powered phone may be required to accompany each multimedia
outlet.
TELUS Communications Inc. (c) 2006-9-22 Page 11
Page 12
Wiring Guidelines for Warm Home- Single Family Dwellings Version V3.0WH
4.4 Cable Routing
Plan the route to avoid possible damage from future construction, rubbing, overheating,
dampness, or contact with power wires. The Canadian Electrical Code, Part 1, (Rule 60-
300) requires a minimum of 50 mm (approximately 2") separation from power cables. We
recommend 12 inches.
The cable route must follow a supported path through floor joists, over ceilings, through wall
studs, and behind baseboards. If possible, the route you select should conceal the cable.
TELUS recommends a minimum of two cable runs (ie. two separate four-pair cables)
to each multimedia outlet to provision for future growth or upgrade of the multimedia
outlet (faceplate).
Separate runs will allow for ease of movement and arrangement of an occupants
telephone, Internet or advanced multimedia services; will reduce time to locate faults and
allow sufficient cable pairs for maintenance and provide for future service additions.
Things not to do
•Do not run parallel to power cables within the same stud or joist space, otherwise
transmission and interference problems may be experienced. Refer to Diagram 4 for
suggested correct installation.
•Do not run communications and data cables through holes occupied by electrical
cables.
• Do not run communications and data cables in parallel with any power wiring.
• Multimedia outlets should not be located within the same studs as a power outlet.
• Never run power in same conduit as communications and data cables.
• If power cables are housed in (metal) armored sheathing, then the above limitations
may not apply, likewise minimum separations may not apply since damaging power
emissions (EMI) are shielded by the sheathing.
•Ensure avoidance of fluorescent light fixtures – see Table 1 below for minimum
Diagram 4: Correct placement of cables and outlets
4.5 Telephones And Communications Devices In Bathrooms
The Canada Electrical Code, Rule 60-400 in summary provides: Communication
equipment located in a bathroom shall be permanently fixed on the wall, and shall be
located so that no part may be reached or used from the bath or from the shower
enclosure.
Telephone jacks are not permitted in bathrooms.
TELUS Communications Inc. (c) 2006-9-22 Page 13
Page 14
Wiring Guidelines for Warm Home- Single Family Dwellings Version V3.0WH
4.6 What Type Of Telephony Devices To Connect?
Telephony devices shall be certified and approved by CSA International (CSA) identified by
the following mark.
Note:
Faulty customer-owned telephony equipment could result in a service charge if TELUS is
called to diagnose the problem.
Figures 2 and 3 are extracted, courtesy of BICSI®, from BICSI® Telecommunications Distribution Methods Manual
(TDMM), 10
th
edition, Chapter 17 (Residential Cabling).
TELUS Communications Inc. (c) 2006-9-22 Page 14
Page 15
Wiring Guidelines for Warm Home- Single Family Dwellings Version V3.0WH
5. Wire/Cable and Outlet Hardware
5.1 Wire Or Cable Selection
Telecommunications wiring must comply with all laws and regulations, whether federal or
provincial and the Canadian Electrical Code.
The minimum grade of inside wiring TELUS recommends is (CAT-5e) Inside Wiring Cable
(IWC) or Premises Communication Cable (PCC) that is Canadian Standards Association
(CSA) approved, designated CMR (formerly FT4 (fire-rated)) per CSA standard C22.2 No.
214-M90. The cable should have a minimum of four pairs twisted 24 AWG solid copper
wires. The outside cover of the wire should be clearly stamped “CSA IWC CMR 24 AWG”,
and have a level 5 (voice and data) transmission rating (CAT-5e) except where the local
electrical authority states that CMP (formerly FT6) is required.
Do not use flat wire such as telephone set line cord or lamp wire for prewiring, as it
can cause transmission problems, errors and low throughput.
5.2 Identifying Conductors In Cabling And Multimedia Outlets
To identify the conductors in new cat-5e cable, strip off a portion of the outer sheath. This
will expose the individual conductors, which are twisted together in pairs. Each working
telephone line requires one pair of conductors, and each pair consists of a Tip (T) and a
Ring (R) conductor. Each MO required for Internet use requires all eight conductors or
wires (ie. four pairs). The manufacturer identifies each conductor by a standard colour
code as shown in Table 2.
Wiring Guidelines for Warm Home- Single Family Dwellings Version V3.0WH
Diagram 5 : Standard 8-pin modular jack (TIA/EIA 568A Standard)
5.3 Outlet Types
A multimedia outlet (MO) provides the means to connect to the following:
• Advanced Multimedia Services;
• Data, Broadband/High-Speed Internet and Data Networking;
• Telephone; and/or
• Optional (Co-ax) for Cable-TV.
Multimedia outlets may combine a multitude of sockets, jacks or connectors of any of the
following types: 8-pin modular jack; RCA; S-Video; F-connectors for Cable-TV coax; or
fibre optics. This would be called a multifunction outlet; (e.g. Belden/CDT MDVO
multimedia module or equivalent).
All 8-pin modular jacks must be wired to match the TIA/EIA-568-A pinout configuration. This
industry standard has been adopted by Canada.
If MO's combine 8-pin modular & F-connectors then the 8-pin modular jack portion shall
also conform to TIA/EIA-568-A pinout standards.
Exterior outlets must be weatherproof.
5.4 Installation Best Practices
See also Section 3, Planning Multimedia Outlet Locations and Cable Routing.
5.4.1 Multimedia Outlet Tips
•Connect 8-pin modular jacks within each multimedia outlet according to the TIA/EIA–
568-A standard as above.
•You must wire up all conductors to the multimedia outlet or 8-pin modular jack
(commonly known as RJ-45). Cat-5e cable consists of eight wires;
connected as previously shown.
•The pairs within cat-5e cabling have twists in them. It is important to insure all pairs
have the correct twist ratios maintained right up to the jack or outlet terminations. Do
TELUS Communications Inc. (c) 2006-9-22 Page 16
all should be
Page 17
Wiring Guidelines for Warm Home- Single Family Dwellings Version V3.0WH
not leave longer pieces straight and untwisted. This will ensure maximum data rates
and minimize interference.
•When running outlet cable (four pair, 24 GA CAT-5e minimum) from multimedia outlets
to your wiring distribution location (DD), ensure each run is a home run (that means a
single direct unbroken cable length). No daisy chaining. This may be referred to as
Star Topology or Star Wiring. (see Diagram 2 and 3)
•Again we recommend a minimum of two cable runs (ie. two separate 4-pair
cables) to each MO to provision for future growth or upgrade of MO faceplate.
•Keep cable runs direct and unbroken between MO and distribution device (DD).
Although it may be tempting to splice two short lengths together to economize on cable
costs, doing so will cause interference, limit flexibility and degrade network
performance.
• Place outlets prior to cladding the wall.
• If possible, protect terminations with plastic bags tied on at both MO and DD cable
ends, prior to completing drywall and painting.
•Coloured jacks for installation into MO may be a useful option for identifying services
eg. black for LAN/internet or white for phone.
5.4.2 Cable Or Wiring Tips
•Do not pull communications and data cables through holes occupied by electrical
cables.
• maximum run length is 90m.
• Cables that cross should be at 90 degrees to each other.
• Do not exert > 25lbs of pulling force on 4-pairs (CAT-5e and 6).
• Do not splice wires on runs – pull another if things go wrong.
• Where required, secure the cable every 600 mm, (24") with a round staple designed for
the wire. Do not pinch the wire.
•Use plastic non-metallic staples to support wire and leave the wire loose in the staples.
Do not drive staples all the way in as microbends in the copper reduce transmission
quality.
•Avoid sharp edges and turns and do not kink the cable, minimum bend radii is 10 x
diameter of cable for CAT-5e, 2.5 inch for co-ax RG-6. If a staple pierces the cable, the
entire length of cable must be replaced to prevent transmission problems. Where sheet
metal framing is used, install grommets to protect the cable from the sharp metal
edges.
•When drilling through floor joists, ensure that the structural integrity is not being
jeopardized. For example, prefabricated joists may have manufacturers’
specification/location for drilling holes. Check with your design engineer/manufacturer
or building inspector.
•Leave at least 30 cm, (12") of excess cable at the outlet end.
TELUS Communications Inc. (c) 2006-9-22 Page 17
Page 18
Wiring Guidelines for Warm Home- Single Family Dwellings Version V3.0WH
• For new homes consider using conduit to allow for easy pulling of future wiring.
• Exterior cabling must use exterior grade cable.
• Do not kick cabling under baseboards, cabling is loose and can become snagged and
damaged. Attaching to baseboards is ok.
5.4.3 DD Tips
• Leave a minimum of 1.5m excess on all cable runs at the DD.
• At a minimum, install two cable runs (communications and data) from your (DD) to the
TELUS demarcation point and NIB when required.
•TELUS recommends IDC style strips or blocks and jumpers/patchcords required for
cross-connects.
•It is critical to ensure all pairs have the correct twist ratios maintained right up to the
IDC strip or block terminations. Do not leave longer pieces straight and untwisted. This
will ensure maximum data rates and minimize interference.
TELUS Communications Inc. (c) 2006-9-22 Page 18
Page 19
Wiring Guidelines for Warm Home- Single Family Dwellings Version V3.0WH
5.5 Multimedia Outlets
Examples of Multimedia Outlets follow....
Faceplate with interchangeable jack module Ortronics MDUTFP11
Faceplate with fixed jack (non-interchangeable) ATI 040-514D-68F2-WHT
The 8-pin modular jacks (RJ-45) must meet the TIA/EIA 568 A/B pin out standard in order to meet
industry certification and cabling standards. Combination 8-pin modular & F-connector jacks (e.g.
Belden/CDT MDVO multimedia module or equivalent) shall also conform to TIA/EIA 568 A/B pin out
standards.
TELUS Communications Inc. (c) 2006-9-22 Page 19
Page 20
Wiring Guidelines for Warm Home- Single Family Dwellings Version V3.0WH
6. Distribution Device (DD)
6.1 Hardware
Builders and homeowners will require hardware to terminate in-home wiring from outlets; a
means to patch or distribute smart home services through to outlets, and provide flexible
reconfiguration of such.
A distribution device (DD) is a cross-connect facility used for the termination and connection
of outlet cables, distribution device cords, and equipment cords. There is no requirement
for secondary protection at the DD.
A DD must be installed inside each home in a location that is accessible for cabling
maintenance. The location should be centralized within the home to minimize the length of
outlet cables.
Initial DD space requirements should be sized at a minimum of 450 mm (18”) width and 450
mm (18”) height. The DD should be positioned such that sufficient unobstructed clearance
will be available for some potential protrusion of equipment outside the wall surface.If the
location of DD necessitates security or physical protection, for example, if located in a
closet or a high traffic area, a cabinet is recommended. The cabinet may protrude from the
wall. Clearance is necessary to ensure access to the cabinet.
A 15A, 120 VAC nominal, non-switchable duplex electrical outlet must be provided adjacent
to the space, board or cabinet or within 0.3 m (1 ft) of the DD. The height of the electrical
outlet should be suitable for the DD and associated equipment being installed and shall be
in compliance with the Canadian Electrical Code.
6.1.1 Recommended Solution
TELUS recommends the installation of an approved TELUS Structured Media Box as
Wiring Guidelines for Warm Home- Single Family Dwellings Version V3.0WH
The TELUS Panel: Ortronics MDUTSP
This distribution panel mounts inside the Ortronics Connect series enclosures and TELUS
enclosures. These panels distribute TELUS TV, Telephone, Data (Ethernet) and have a
Security port to interface with alarm panels.
See Section 11: Appendix C: DD Panel Configuration (Ortronics)
6.2 Installation Best Practices
1. Required Space – Ortronics Enclosure
2. Distribution Panel – TELUS MDUTSP1
3. Entry point for runs from Multimedia Outlets in rooms and cable run from NIB.
4. Multiple cat 5e runs from rooms and NIB
5. Entry points to DD Distribution Enclosure
6. Reserved area to mount Modem and Router
7.
Un-switched 120V Duplex outlet
8. For larger homes with more runs, additional components may be required.
Locate your DD panel or cabinet no closer than 12" (30cm) to a power distribution panel,
suggested distance is 24" or 60cm, to protect network equipment from sources of
interference.
Clearly mark all set runs, with MO location id and type of service on each (if known)
suggested e.g. MBR01, KTCH01, DNGR01, LIVR01a LIVR01b. Clearly identify and mark
all services and ports.
Use a tone generator or Fluke MicroscannerPro kit to assist in determining which cable
runs connects to which room. See instructions supplied with your tool.
6.3 Connecting ADSL Service
For single room outlet requiring ADSL service:
1. patch RJ-11 jumper from RJ-11 jack marked ADSL to the RJ-11 jack on
modem
2. patch RJ-45 jumper from ADSL modem to appropriate room outlet jack
For multiple outlets requiring service:
1. install a switch or residential gateway
2. patch RJ-11 jumper from RJ-11 jack marked ADSL to the RJ-11 jack on
modem
3. patch RJ-45 jumper from ADSL Modem Ethernet port into one
switch/gateway/router port (possibly marked WAN or UPLINK port); patch all
TELUS Communications Inc. (c) 2006-9-22 Page 21
Page 22
Wiring Guidelines for Warm Home- Single Family Dwellings Version V3.0WH
outlets to be "ADSL Enabled" into remaining ports on switch/gateway/router
you may own.
7. Connecting Telephone Service
7.1 Safety Precautions
Remember, when working on existing telephone service it is possible to come in contact
with electrical currents. Again, TELUS recommends that installations be carried out by a
trained technician. Work on telephone or any wiring should never be undertaken during
thunder and lightning storms.
To reduce possible feedback of potentially hazardous voltages either caused by lightning
strikes or contact with high voltage power lines, the Canadian Electrical Code requires the
installation of a primary protector as per Rule 60-200 as noted below:
60-200 Provision of Primary Protectors:
(1) A primary protector shall be provided on each electrical communication circuit, except
as provided in Subrule (4).
(2) The primary protector shall be located in, on, or immediately adjacent to the structure or
building served and as close as practicable to the point at which the conductors enter or
attach.
(3) The primary protector shall not be located in any hazardous location as defined in
Sections 18, 20 and 24, nor in the vicinity of flammable or explosive materials.
(4) A primary protector need not be provided if no portion of the circuit is considered
exposed plant.
Primary protection must be provided on circuits considered exposed plant. Where located
outdoors, the
circuit shall be located below grade level and installed in a conduit. These
circuits shall not have any exposure to lightning or contact with power lines at all times.
Direct buried cable/
conductors are generally classed as exposed plant because they are
usually susceptible to lightning strikes.
7.2 Service Connection
In new homes, the telephone entrance cable (aerial or underground) terminates in the NIB
box located on the outside walls of your single-family residential buildings. It is usually
located close to the electrical meter. To gain access to the NIB box or NIB lid and to the
demarcation jacks, loosen the screws and optional customer lock located on the right hand
side of the NIB box or lid. With the outer door swung open, access to the demarcation
jacks and/or inside wire is now possible.
In accordance with regulations, TELUS must be contacted to determine the proper
demarcation point.
7.3 Demarcation Point
The terminals found on demarc blocks and protectors could be marked in a number of
ways:
Conductor Colour Identification TELUS side Customer side
TIP Green T1
RING Red R1
T
in
R
in
T
out
R
out
TELUS Communications Inc. (c) 2006-9-22 Page 22
Page 23
Wiring Guidelines for Warm Home- Single Family Dwellings Version V3.0WH
WARNING!
Altering or adding to the telephone protector could be hazardous to your property or
person and should never be undertaken except by a trained telephone technician.
TELUS Communications Inc. (c) 2006-9-22 Page 23
Page 24
Wiring Guidelines for Warm Home- Single Family Dwellings Version V3.0WH
8. Testing The Wiring And Multimedia Outlets
Verification testing should be performed on all outlet and cable installations. Test for the
following faults:
• opens
• shorts
• miswires
• discontinuities, pin-to-pin or other
• grounds
Example Test steps:
No. Step Expected Result Pass/Fail
1 Insert test cable from test instrument into Modular 8-pin
Jack (RJ-45) socket of Multimedia Outlet
2 Run Wiremap test to ensure correct cable/socket wiring. Pass
3 Run Length test: Length required less than 90m (295 ft) Less than 90m
4 Check for cable faults (indicated by distance Open or
Short is away from outlet under test)
5 Check far-end connector (at DD) is not faulty No faults
1.
Note: This verification check for residential wiring does not test the information carrying
capacity of the link. Network cables installed in typical residences are shorter than those
found in commercial installations and do not suffer as much from losses. Good capacity
can be expected when the guidelines for cable routing and installations have been adhered
to.
No faults or zero
distance
Suggested testing devices include:
• FLUKE MicroScannerPro (or better)
• FLUKE DSP4300
• Agilent Wirescope 350
• ResiTester
or similar.
TELUS Communications Inc. (c) 2006-9-22 Page 24
Page 25
Wiring Guidelines for Warm Home- Single Family Dwellings Version V3.0WH
9. Appendix A: Sample Test Summary Report
Home Network Certification – Verification Check Sheet and Install Record
Installation date: ___
Service contact Ph.: (____) __
Installation #:
Development Name:
Address:
Lot/Block:
City:
Province : Postal Code:
/__ / Crew: __________________
_______________
Installer Company Name:
Address:
City:
Prov: Post Code:
Phone:
Email:
Example is shown on first line with number of drops per cable type.
Note C3 = category 3 C5= category 5 C5e= category 5e C6 = category 6
Test – V = Verified for continuity, wiremap, and length, C = Certified to cabling performance specified per the ANSI/TIA/EIA-570-A Standard
Outlet / Drop
Location
Example: MBR01
Voice Data Coax Other / Note
C3
C5
1 V 1 C
C5e
C6
Test
C3
C5
C5e
C6
Test
RG-6
RG-11
Test
primary TELUS outlet
TELUS Communications Inc. (c) 2006-9-22 Page 25
Page 26
Wiring Guidelines for Warm Home- Single Family Dwellings Version V3.0WH
10. Appendix B: Wiring Terminations
10.1 Wiring Terminations In NIB
Ensure no more than 2 twists are undone when terminating CAT 5e cable
1. Drop Wire and Inside Wiring to be terminated according to the following instructions:
• T stands for Tip and will always be the Predominately White wire with a colored stripe
• R stands for Ring and will always be the Predominately “Colored” wire corresponding to
the Tip colored stripe
• See attachment: IDC Termination Instructions
• Terminate the Copper Drop wire on the protection unit on the door in the following
manner:
•Untwist a SINGLE twist of the CAT5e Drop Wire pair (White / Blue) and terminate
on the IDC connector marked T (in) and R (in)
•Terminate the CAT5e Inside wire on the Pots Splitter unit on the door in the following
manner:
• Strip the ends of the CAT5e Inside Wire pair (White / Blue) ½” from the end
• Untwist a SINGLE twist of the CAT5e Inside Wire pair (White / Blue) and terminate
on the screw terminals of the Pots Splitter marked Phone
• Strip the ends of the CAT5e Inside Wire pair (White / Green) ½” from the end
• Untwist a SINGLE twist of the CAT5e Inside Wire pair (White / Green) and
terminate on the screw terminals of the Pots Splitter marked ATU-R
10.2 IDC Termination Instructions
Open contact
actuator by
simply pulling
back on “Baseball
caps” with thumb
or finger. Do
over open. (Figure
1)
not
Insert wire pair
into color coded
ports. (Figure
2)
Visually inspect for full
wire insertion through
the transparent body.
(Figure 2A)
Close firmly. Hear,
feel, snap and lock
(Figure 3). Repeat for
each connection.
Note: Make sure that
all contact actuators
are left in the “down”
or locked position.
TELUS Communications Inc. (c) 2006-9-22 Page 26
Page 27
Wiring Guidelines for Warm Home- Single Family Dwellings Version V3.0WH
Open contact
actuator to fully
open position by
simply pulling back
on “baseball caps”
with thumb or
finger. Do
not over
open. (Figure 4)
Remove wire by
pulling it out fully.
If existing wire is
to be re-used, cut
off at least ¼”
(6mm) before retermination (Figure
5). Repeat
termination
procedure above.
TELUS Communications Inc. (c) 2006-9-22 Page 27
Page 28
Wiring Guidelines for Warm Home- Single Family Dwellings Version V3.0WH
Wiring Guidelines for Warm Home- Single Family Dwellings Version V3.0WH
11.1 ORTRONICS MDUTSP - IDC / Pin Identification
• INCOMING JACK
o IDC on the back to a RJ45 on the front
4 pair feed from NIB is terminated on the IDC
• Pr 1 – Dialtone
• Pr 2 – Vacant
• Pr 3 – DSL Signal
• Pr 4 – Reserved for 2
All Pairs are connected through to the RJ45 Incoming Jack
• Pair 1 connects to Pins 4 & 5
• Pair 2 connects to Pins 3 & 6
• Pair 3 connects to Pins 1 & 2
• Pair 4 connects to Pins 7 & 8
RJ45 patch cord (included) then patch dial tone to “security in”.
Blank is included for future use if required. An addition RJ45 may be
inserted.
• SECURITY JACK o IN JACK
All 4 pairs plugged into “security in”, Pair 1 is bridged to “in” of RJ31X for
POTS service only when a RJ45 plug is inserted into “RJ31X” port
Pairs1 2, 3 & 4 from the RJ45 are distributed to “security out”
o RJ31X JACK
When the cord to the Alarm Panel is plugged in, dialtone is routed thru the
alarm panel and back out to the out of the RJ31X
Out pair of RJ31X bridged to pair 1 of OUT
o OUT JACK
Patch Cord from OUT to ADO to feed dialtone and DSL to jacks
• ADO JACK o Pairs 1 & 4 are bridged to pairs 1 & 4 of LOC 1 thru LOC 13 and EXP
When the patch cord from SECURITY OUT is connected, dialtone is
supplied to LOC 1 thru LOC 13 and EXP jacks
When the patch cord from SECURITY OUT is connected, DSL is supplied
to “DATA INTO MODEM”
Pairs 2 & 3 are bridged to “DATA INTO MODEM”
•DATA INTO MODEM JACK o RJ11 cord feeds DSL signal to modem (PAIRS 2 & 3, PINS 1,2 & 3,6)
•LOC 1 thru LOC13 & EXP JACKS
o Pairs 1 & 4 are bridged between jacks
o Straight 4-pair IDC on the back to a RJ45 on the front
Inside wire set runs providing POTS and DSL services are terminated on
LOC1 thru LOC13 as required
DSL service is provided to the individual room outlets when a patch cord is
connected from the modem or router as required
Pairs 2 & 3 are passed to IDC on rear at each location(non-bridged)
• TV JACKS o Straight 4-pair IDC on the back to a RJ45 on the front (CAT 5e)
Designated TELUS TV inside wire set runs are terminated as required
Service is provided when a patch cord is connected from a switch
• AUX JACKS
o Straight 4-pair IDC on the back to a RJ45 on the front (CAT 5e)
For future expansion
nd
line
TELUS Communications Inc. (c) 2006-9-22 Page 29
Page 30
Wiring Guidelines for Warm Home- Single Family Dwellings Version V3.0WH
11.2 DD Panel Termination (Ortronics)
All terminations on the Ortronics Panel are to be completed with the appropriate 110 Tools.
NOTES:
1. Terminate the 4 pair CAT 5e feed to the panel on the back of the Incoming Jack.
2. Terminate all Tel/Data runs on Locations 1-13
3. Terminate all TELUS TV runs on TV1-4 locations and AUX 1 & 2 in required
4. Complete the Label on the inside of the panel cover
5. For single set runs to each location, the Ortronics MDUTFP11 or ATI 040-514D-68F2WHT jacks may be used
If 2 set runs are placed to each location, 1 will be dedicated for Tel/Data and the other will be
dedicated for TELUS TV and terminated on the panel as indicated. This scenario requires the
Ortronics jack MDUTFP11 for the Tel/Data and an RJ45 EDVO outlet added in the bottom knockout
position
When single Cat-5e set runs are used with the TELUS MDUTSP1 Panel (Distribution Device), a
dual jack consisting of single RJ-11 and RJ-45 (8-Pin Modular) such as an Ortronics MDUTFP11-88
or an ATI 040-514D-68F2-WHT can be used.
TELUS Communications Inc. (c) 2006-9-22 Page 30
Page 31
Wiring Guidelines for Warm Home- Single Family Dwellings Version V3.0WH
12. Appendix D: 8-PIN Modular Jack Terminating Instructions
The (RJ-45) jacks are to be terminated according to TIA-568-A standards as shown below.
Standard 4-Pair Wiring Color Codes
Pair 1 T
R
Pair 2 T
R
Pair 3 T
R
Pair 4 T
R
White/Blue
Blue/White
White/Orange
Orange/White
White/Green
Green/White
White/Brown
Brown/White
TELUS Communications Inc. (c) 2006-9-22 Page 31
Page 32
Wiring Guidelines for Warm Home- Single Family Dwellings Version V3.0WH
13. Appendix E: Strata Developments
The following is an example of a Strata style development where the TELUS Entrance Cable is
terminated and protected in a structure near the entrance to the development. The MDU Pots
Splitter is also located in this location.
NOTES:
1. A Transition Housing must be placed at each house for transitioning the drop cable to
the 4 pair CAT 5e inside wire from the TELUS Hub.
2. When individual 4 pair drops are placed to each housing unit, all 4 pairs of the drop and
the 4 pair CAT 5e inside wire from the TELUS Hub must be terminated on an approved
CAT 5e connector. (i.e. a grease filled BIX strip complete with BIX Wire Retainer clips).
TELUS Communications Inc. (c) 2006-9-22 Page 32
Page 33
Wiring Guidelines for Warm Home- Single Family Dwellings Version V3.0WH
14. Appendix F: Industry standards
Standards pertaining to the creation of this TELUS wiring guide:
National Building Code of Canada
Canadian Electrical Code and British Columbia / Alberta Electrical Code
CAN/CSA No.T525-94 – Residential Wiring for Telecommunications
CAN/CSA C22.2 No.182.4 – M plugs, Receptacles Connectors for Communication Systems
CAN/CSA T530 – M90 Building Facilities Design Guidelines for Telecommunications
CAN/CSA T528 – Design Guidelines for Telecommunications
CN/CSA T528 – Design Guidelines for Administration of Telecommunications Infrastructure in
Commercial Buildings
CS-03 – Terminal Attachment Program
TIA/EIA-568-A – 8-pin modular jack wiring configurations
TIA-570-A and TIA-570-B "Residential Telecommunications – Infrastructure Standard"
Acknowledgements
Diagrams 2 and 3 in this guide, are extracted, courtesy of BICSI®, from BICSI® Telecommunications Distribution Methods Manual (TDMM), 10
Cabling).
th
edition, Chapter 17 (Residential
Additional Information
For British Columbia : use Form P546 - Residential Service Entrance Requirements,
For Alberta : use Form P630 - Residential Service Entrance Requirements,
Forms are available from the Building Industry Consulting Service Web site at:
http://www.telus.com/bics
or call TELUS Prewire at :
1-800-665-5259 in British Columbia
1-888-530-6900 in Alberta
TELUS Communications Inc. (c) 2006-9-22 Page 33