Telular TL9XC Users Manual

DRAFT COPY
90 Series
Wireless Remote Tank Monitor
HOST AND CLIENT CONFIGURATION
Document Rev. -
Document No. 910-00017
January 4, 2016
Page 2
Table of Contents
Contents
FCC Statement ..................................................................................................................4
WARNING! For Your Safety .......................................................................................5
1 Revision History ............................................................................................................6
2 Series 90 Introduction ...................................................................................................7
Overview ................................................................................................................7
For Your Safety .......................................................................................................7
3 Theory of Operation ......................................................................................................8
Transfer of Data ................................ ...................................................................... 9
Product Highlights ..................................................................................................9
4 Installation .....................................................................................................................9
Safety Precautions ...................................................................................................9
Initial Inspection ................................................................................................... 10
Installation Precautions ......................................................................................... 10
4.3.1 Installation of the 90 SERIES ...................................................................... 11
System Control Drawing for the Uplink Model Only ............................................. 12
5 Accessing the TankLink Website ................................................................................. 14
Tank Measurements – Website Tank Configuration .............................................. 14
Setting the Number of Callouts per Day ................................................................ 15
5.2.1 Scheduled Callouts ................................................................ ....................... 15
5.2.2 Call On % Change ........................................................................................ 16
5.2.3 Affectivity of Callout Setting Changes or Programming ............................... 16
Normal Operation.................................................................................................. 16
6 Series 90 Specifications .............................................................................................. 17
Cellular Specifications ................................................................................................. 17
7 Servicing and Troubleshooting .................................................................................... 18
Error Codes ........................................................................................................... 18
Battery Replacement ............................................................................................. 20
Troubleshooting ................................ .................................................................... 21
Obtaining Technical Support ................................................................................. 21
8 Replacement Parts ....................................................................................................... 22
9 Terms and Conditions of Service ................................................................................. 22
10 Product Warranty and Notices ..................................................................................... 24
Page 3
IC STATEMENT
This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement
FCC Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device must not be allowed to cause harmful interference (2) This device must accept any interference that may cause undesired operation.
Page 4
WARNING! – For Your Safety
For Your Safety:
Read these installation and operation instructions carefully. Failure to follow these
instructions may result in death or serious injury.
Caution: The battery pack used in this device may present a fire or chemical burn hazard if
mistreated. Do not recharge, disassemble, heat above 100°C (212°F) or dispose of in fire. Replace battery pack with TankLink P/N 394-00023 only. Use of another battery pack may present a risk of fire or explosion.
Only qualified service personnel must install or repair this equipment. Do not disassemble the housing unless the area is known to be non-hazardous. Remove the
electronic enclosure from the hazardous area prior to changing the battery pack. Refer to section 3 for installation details.
Substitution of parts may impair the intrinsic safety of this equipment. This equipment must be installed in accordance with local requirements and the National
Electric Code.
Copyright 2015 TankLink Inc.
No part of this document may be copied, reproduced, or translated without the prior written consent of TankLink Inc. No part of this document may be stored or transmitted in any electronic form without the prior written consent of TankLink Inc.
TankLink Inc. has made every effort to ensure the accuracy and completeness of this document. However, as we are continually making improvements to our products, we cannot guarantee the accuracy of this document. We will not be liable for any inaccuracies, omissions, or future changes.
TankLink and the TankLink logo are registered trademarks of TankLink Inc. All other trademarks referenced herein are the properties of their respective organizations.
Page 5
Version
Date
Description of Changes January 4, 2016
Draft Release
1 Revision History
Page 6
2 Series 90 Introduction
Overview
The Series 90 are wireless communication devices that provide quick and easy access to remote tank information such as product level and volume. Intended for supplier-managed inventory programs, the Series 90 utilizes the latest internet and cellular technologies to provide instant access to inventory information around the globe. Coupled with the TankLink® information website, the Series 90 can provide a tremendous advantage over conventional systems for inventory management, asset control, or information exchange.
The Series 90 is also available in Host and Client Model configurations. This is advantageous where a number of tanks are collocated together such that a single Host unit may communicate with several Clients. The advantage is that only one Cellular radio can perform all communications with the TankLink Data Center for itself and its Clients. Thus simplifing installation and maintenance. Contact TankLink sales for more information.
For Your Safety
Read these installation and operation instructions carefully. Failure to follow these instructions may be dangerous or illegal.
Only qualified service personnel must install or service this equipment.
Page 7
3 Theory of Operation
Figure 1
Page 8
Loading...
+ 18 hidden pages