P141
Heavy Duty Pressure Transmitter
Precision Grade- For Harsh Environments
Designed for the hazardous locations
P141 Pressure Transmitter is designed for use in
hazardous locations. The entirely welded 316LSST
construction is hermetically sealed.
Low Cost
Manufactured for reliable service in aggressive environments
The P141 is manufactured for reliability in aggressive environments
where other transmitters fail. Automated weld procedures,
extreme environmental burn in, and the mounting of electronics
to withstand the most severe shock and vibration applications assure
safety and reliability. Additional EMI/RFI ltering with surge protection
add to the performance of the P141.
Alternate materials for service in corrosive environments
For corrosive environments where 316L or 15-5 SS are not best
suited, the P141 is available in Hastelloy C276, C22 or Inconel 718.
Certication
Each P141 transmitter is shipped with a NIST traceable
calibration certicate.
CE
Conforms to EN50081-2 and EN50082-2
Standard Features
Hermetically Sealed Package
±0.25% FSO Static Accuracy
0-3 psi through 0-15,000 psi
Possible Switch
Replacement
Available Options
±0.1% FSO Static Accuracy
±0.5% FSO Thermal Error Band
Hastelloy or Inconel alt. materials
Low Power
Note: specications are subject to change.
Tel-Tru Manufacturing Co.
408 St. Paul Street
Rochester, New York 14605 USA
Phone: 585-232-1440 • 800-232-5335 • Fax: 585-232-3857 • E-mail: info@teltru.com • Web: www.teltru.com
P141 Pressure Transmitter
Designed for Hazardous Locations
0-3 psi through 0-15,000 psi
Product Specications
Electrical
Excitation
P141A, P141B 8-38 Vdc*
P141C 2-15 Vdc
Output
P141A 4-20 mA
P141B 0-5 Vdc*
P141C 1-2 mV/V*
Zero Balance =± 1% FSO
FSO Setting =± 1% FSO
Resolution Innite (±.001% FSO usable)
Response Time
P141A, P141B < 5 mS
P141C < 1 mS
Insulation Resistance 1000 MO @ 50 Vdc
Reverse Polarity Protected
Warm-up < 10 mS
Power Supply Effect =±.002% FSO per V input (P141A, P141B)
EMI/RFI Internal Filtering (P141A, P141B)
Short Circuit Protected Up to 40 Vdc (P141A, P141B)
Mechanical
Pressure Ranges 0-3 through 0-15,000 psi
(Customer may specify any range/eng. unit FOC)
(Absolute, vacuum, compound available options)
Proof Pressure 2X Full Scale*
Burst Pressure 5X Full Scale*
Materials
Wetted Parts* 316 & 15-5 SST*
Non-wetted Parts 316 SST plus electrical connector*
Pressure Port 1/4" NPT Female*
Electrical Connector NEMA 4X cable exit (24" cable)*
Dimensions per outline below
Weight nominal 15 oz.
Environmental
Compensated Temp Range 0 to 170°F
Operating Temp Range -40 to 200°F
Storage Temp Range -40 to 250°F
* Options available
Performance
Static Accuracy =±0.25% FSO* (BFSL, RSS)*
(combined effects of non-linearity, hysteresis & repeatability)
Repeatability =±0.05% FSO
Temperature Effects =±1.5% FSO over comp range*
(combined effects of Zero & FSO with reference at 70°F)
Long Term Stability =±0.25% FSO per year
Note: specications are subject to change.
Tel-Tru Manufacturing Co.
408 St. Paul Street
Rochester, New York 14605 USA
Phone: 585-232-1440 • 800-232-5335 • Fax: 585-232-3857 • E-mail: info@teltru.com • Web: www.teltru.com
Drawing