An accurate, safe, convenient, and costeffective thermometer calibration system
www.teltru.comwww.teltru.co m
Page 2
Verify Thermometer Accuracy at Your Critical Control Point!
The Tel-Tru Check-Set Series of Thermometer
Calibrators provides accurate, unambiguous, and
cost-effective calibration and accuracy verification for
a wide range of thermometers and temperature
measurement instruments.
The Check-Set series is the perfect temperature
reference device for:
• Plant quality assurance
• Process control
• Food safety
• Instrument calibration and service
• HACCP compliance (Hazard Analysis Critical
Control Points)
The Check-Set is easy to use, reliable, accurate and
compatible with a wide range of:
• Dial and digital thermometers
• Filled system bulbs
• Electronic temperature sensors
Typical users of the Tel-Tru Check-Set Calibrators
are food safety professionals responsible for
operating, inspecting or certifying:
• Food preparation and food service facilities
• Industrial canning, meat, dairy and beverage
processing plants
• Users include:
- HACCP compliance officers
- QA managers
- In-plant maintenance technicians
- Field calibration contractors
- Local, state, and federal agency compliance
officers
FEATURES
• The series includes:
- Check-Set I with one calibration set point
- Check-Set II with two calibration set points
- Check-Set IV with four calibration set points
• High accuracy
- Certificate of Calibration traceable to NIST
- Built-in warning circuitry to alert user when
unit exceeds set-point by 1°F
• Fast calibration verifications
- Simple to use
- Easy operator training
• Serial number assigned to each unit
• Portable - optional padded shoulder strap
available (except CS1-HOT models)
• Rugged enclosure and electronics for reliable
service
• Quick Start Guide
Compatible with thermometers and temperature probes
of all sizes!
2
www.teltru.com
CALIBRATION SERVICE
• An annual factory recertification service is
available.
• Completion of recertification service extends the
warranty one additional year, for up to nine
years.
Page 3
Check-Set Accuracy ±0.2ºF (0.1°C)
GENERAL SPECIFICATIONS
• Accuracy ±0.2°F (0.1°C)
• Input Power 115 volts, 50/60 Hz, 1.5 amps
• Recommended Ambient Operating temperature range:
- 65-85°F (18-29°C)
• Type 304 stainless steel enclosure
• Weight:
- All models: 9 lbs. (4 kg)
• Dimensions:
- Check-Set I HOT: 11 x 65⁄8 x 31⁄8" (279 x 168 x 79mm)
- All other models: 83⁄4 x 87⁄8 x 41⁄4" (222 x 225 x 108mm)
• US patent #6,170,983
IMPORTANT CALIBRATION TEMPERATURES
The Check-Set series of thermometer calibrators
verifies the calibration of your temperature sensing
devices at multiple temperatures. Their accuracy also
allows you to validate your temperature measuring
devices at temperatures specific to your application.
For example, in the food and dairy industry, important
temperatures or “set-points” include:
• 40°F (5°C): Recommended cold food holding
temperature
• 140°F: Recommended hot food holding
temperature
• 150°F: Clean-in-Place return lines
• 160°F: E.Coli safety temperature
• 161°F: HTST flash pasteurization - milk
• 175°F: HTST flash pasteurization - ice cream,
eggnog, frozen desserts
• 212°F: Boiling point of water
Dial Adjustment Tool makes calibrations easy!
(sold separately)
“READY TO USE” TIMES
Users often keep the Check-Set units on all day so they are
ready for use “on demand.” Typical “ready to use” times from
ambient:
ModelCalibration
Temperature
Check-Set I
HOT
Check-Set I
COLD
Check-Set II 40°F 5 min.±0.03°F
Check-Set IV 40°F 6 min.±0.03°F
140°F10 min.±0.06°F
160°F14 min.±0.06°F
212°F20 min.±0.06°F
40°F 5 min.±0.03°F
160°F 7 min.±0.03°F
5°C 5 min.±0.02°C
90°C12 min.±0.02°C
150°F 6 min.±0.03°F
161°F 7 min.±0.03°F
175°F 9 min.±0.03°F
Ready to
Use Time
Stability
Eliminate Error-Prone and Cumbersome Calibration Methods
The Ice Water Method
• Difficult
• A “pain”
• Time consuming
• Error-prone
The Boiling Water Method
• Dangerous
• Time consuming
• Difficult
• Error-prone -- boiling
point of water varies
with altitude
www.teltru.com
3
Page 4
Markets and Applications Served
Commercial Food Service
• Chain Restaurants
• Grocery Chains
• Corporations
• Airlines
• Hotels
• Restaurants
• Theme Parks
• Sports Arenas
Institutional Food Service
• Military Bases
• Public School Districts
• Colleges and Universities
• Hospitals
• Government Medical Centers
• Dept. of Corrections
Food Processing, Storage, and Distribution
• Red Meats
• Poultry
• Seafood
• Sausage and Hot Dogs
• Baked Goods
• Dairy Products
• Grains
• Tomatoes
• Pickles
• Corn Syrup
• Produce
• Wholesale Food Distribution
Training and Education
• Chef Training/Culinary Arts School
• HACCP and Food Safety Training
Environmental Safety and Health Professionals
• City Health Dept.
• County Dept. of Environmental Health
• State Dept. of Health
• Federal Agencies
• Military Food Safety Inspectors
Industrial/OEMs
• Research and Development Lab
• Industrial Laboratory
• Service and Calibration of:
– Refrigeration Equipment
– Industrial Ovens
– Smokers for Meat/Poultry
• Manufacturer of Food and
Beverage Testing Equipment
FOOD
SAFETY/
HACCP
Background
HACCP (Hazard
Analysis Critical
Control Point) is a
systematic
preventative
approach to food safety that involves the definition of
specific measurements to reduce risk. HACCP
techniques focus on the prevention of hazards and
not upon final inspection. HACCP principles are
widely applied to FDA and USDA regulated industries
and a growing list of international industries,
government agencies, and organizations.
Requirements
Satisfactory monitoring of CCPs requires accurate
and precise measurements of parameter values (e.g.
temperature, pressure, pH, etc.) to ensure that
defined Critical Limits are met. Equipment used to
make those measurements must be properly
calibrated.
The HACCP plan must describe instrument
calibration procedures and frequency, responsible
individuals and required documentation records for
instruments used measuring those parameter
values.
Check-Set Series Delivers
Check-Set Calibrators are designed for Food Safety
Professionals as an easy-to-use tool to verify
the calibration of temperature measurement
instruments in compliance with HACCP
requirements.
Check-Set users can check thermometers and other
temperature sensing instruments at temperatures
equal to or close to the critical control points of their
processes.
4
www.teltru.com
Page 5
Markets and Applications Served
DAIRY
Background
The ”Pasteurized Milk
Ordinance” (“PMO”)
regulates the
production,
transportation,
processing, handling, sampling, examination, labeling,
and sale of all “Grade A” milk and milk products, as
well as the inspection of dairy farms, milk plants,
receiving stations, transfer stations, milk tank truck
cleaning facilities, milk tank trucks and bulk milk
hauler/samplers.
Requirements
The PMO defines the performance requirements and
testing methods for test, indicating, and recording
thermometers, and other temperature instruments.
The PMO requires that temperature instruments be
“compared to a certified temperature source” upon
installation and every 3 months thereafter, and after
equipment is altered, serviced, repaired or replaced.
Check-Set Series Delivers
The Tel-Tru Check-Set IV Calibrator is optimized for
compliance with the temperature instrument
calibration and verification requirements of
the dairy industry
cheese processing plants.
Typical users include in-plant staff responsible for
QA, food safety, HACCP compliance and instrument
maintenance. Other users include field calibration
contractors and regulatory agency personnel who
inspect and certify these plants.
Enjoy less plant down time due to faster and easier
certification of temperature instruments
• No ice water, no ice buckets
• No temperature controller circulators
• Easy to carry throughout the plant
• Probe inserts for most probe sizes
including milk, ice cream, and
FOOD
PROCESSING/
RETORTS
Background
Thermal processing
of food in various
types of pressure
retorts is regulated by
the Food and Drug
Administration through the establishment of rules for
equipment, and temperature indicating, recording and
controlling devices.
A major food processing industry trade association
also recommends voluntary guidelines for food
processors to test and document the temperature
distribution within their retorts.
Requirements
FDA Rule 21 CFR 113.40 specifies that each retort
must be equipped with at least one temperatureindicating device, a temperature recording device, and
a temperature controller. These instruments must be
checked with a reference device that is directly
traceable to National Institute of Standards and
Testing (NIST) “to ensure accuracy during processing.”
FDA Rule 21 CFR 113.100 defines the required record
keeping for reference devices including: identification
of the device, a Certificate of Calibration, date and
results of the test, and date of the next test.
The Institute for Thermal Processing (IFTPS)
recommends voluntary guidelines for operators of
retorts in food processing plants to test the thermal
efficiency of their retort equipment:
• All temperature instruments conform to applicable
Federal Regulations and are tested against an
accurate and traceable reference device.
• A calibration process is recommended before and
after testing to assure that the temperature
indicators and sensors on the retort and on an
external monitoring system are consistent and
accurate.
Check-Set Series Delivers
Tel-Tru Check-Set Calibrators are accurate and
certified temperature reference devices that
meet the requirements of the FDA and the
recommendations of the IFTPS
accuracy of temperature instruments in food
processing plants. Tel-Tru Check-Set features include
a unique serial number, a certificate of accuracy
traceable to NIST, and available annual
recertification and maintenance service.
for verifying the
www.teltru.com
5
Page 6
Do you need to verify hot temperatures only?
Drawing A
(CS1-HOT)
What temperature(s) do you
want to verify?
4.0" Insulated Zone 4.0" Te mp. Control Zone
PROBE SENSING AREA
What are the stem diameters of the
instruments you are checking?
STEm-LENGTH COmPATIbILITY
For best results, the sensing area of the probe must be inserted
completely into the Temperature Control Zone. The minimum
immersion depth is dependent on the thermometer type. Check the
manufacturer’s user manual of your thermometer for the correct
immersion length.
CS1 w/ single hole configuration—Code 100
Frequently used in food preparation or food processing plant
environments to verify accuracy of digital or dial thermometers at a
single hot test point. Built-in wrench is for easy calibration adjustment
of spot check or meat cooking dial thermometers.
CS1 w/ multi-hole configuration—Code 400
Used in food preparation, food processing and industrial environments
to verify accuracy of several types of temperature measurement
instruments at a single hot test point. Built-in wrench is for easy
calibration adjustment of spot check or meat cooking dial
thermometers.
OPTIONS AND ACCESSORIES AVAILABLE FOR ALL UNITS ...........................................................................................Part #
Dial Adjustment Tool for 1" and 2" thermometers (set of 3) ..............................................................................................96100055
Cleaning Brushes for models that fit probe diameter up to .150" (set of 3)......................................................................96100054
Cleaning Brushes for multi-hole models (set of 2) ............................................................................................................96100145
Carrying Strap (for all except CS1-HOT) ..........................................................................................................................96100224
FACTORY RECALIBRATION/RECERTIFICATION SERVICE
Tel-Tru Manufacturing Co. offers annual maintenance, inspection, cleaning, and accuracy recertication of each
Check-Set thermometer calibrator. Recertication automatically extends the product warranty one additional year,
for up to nine years. Contact Tel-Tru Customer Service for details.
Visit our website at www.teltru.com/calibrator.asp for more information on the Check-Set series of thermometer calibrators and
accessories.
6
www.teltru.com
Page 7
Do you need to verify cold and/or hot temperatures?
Drawing A
(CS1-HOT)
4.0" Insulated Zone 4.0" Temp. Control Zone
PROBE SENSING AREA
Drawing B
(All other models)
What temperature(s) do you
want to verify?
3.0" Insulated 3.0" Te mp.
Zone Control Zone
PROBE SENSING AREA
What are the stem diameters of the
instruments you are checking?
STEm-LENGTH COmPATIbILITY
For best results, the sensing area of the probe must be inserted
completely into the Temperature Control Zone. The minimum immersion
depth is dependent on the thermometer type. Check the manufacturer’s
user manual of your thermometer for the correct immersion length.
CS1-F42-310 shown with
removable well P/N 96100250
• Designed for use with
refrigeration.
ADDITIONAL WELL INSERTS FOR CHECK-SET I COLD, II AND IV .................................................... PART #
Note: Wells with other hole diameters available upon request
Most
popular
unit
CS2-F50-320 shown with removable well P/N
96100249 - multi-hole configuration and built
in wrench
• Hot-Cold dual set point unit for general
HAACP verification of many types of
temperature instruments in food service, food
processing, and meat packing environments.
• Built-in wrench is for easy calibration adjustment of spot check or meat cooking dial
thermometers.
www.teltru.com
CS4-F80-310 shown with
removable well P/N 96100250
• Designed with 4 critical set
points for use in dairy products
plants.