Teltone ILS-1000 User Manual

ILS-1000
ISDN Li ne S imulator
User Manual 40-400-00001, Rev. A
40-400-00001, Rev. A 47
Contents
IMPORTANT SAFETY INSTRUCTIONS ........................................................................................... 2
Introduction ....................................................................................................................................... 4
Unpacking ....................................................................................................................................... 5
Optional Accessories..................................................................................................... 5
ILS-1000 Operation ....................................................................................................... 9
What To Read Next ..................................................................................................... 10
Chapter 2: ISDN-BRI ......................................................................................................................11
Technology Overview................................................................................................... 11
Layer 1 - Physical Operation .......................................................................................11
Layer 2 - Data Link Operation..................................................................................... 12
Layer 3 - Network Operation....................................................................................... 13
Chapter 3: Provisioning and Operation ........................................................................................ 15
Configuration Software Installation............................................................................. 15
Figure 1 ILS-1000 Configuration Software Opening Screen..................................... 16
General Operation ...................................................................................................... 16
Defaults ....................................................................................................................... 17
Switch Type................................................................................................................. 17
D Channel X.25.......................................................................................................... 17
B Channel Provisioning ............................................................................................... 19
Caller ID ...................................................................................................................... 19
Terminal Display Text .................................................................................................. 20
Electronic Key Telephone Ser vice (EKTS) ................................................................. 20
Multi-Point ................................................................................................................... 21
Call Appearances........................................................................................................ 21
Key Hold...................................................................................................................... 22
Additional Call Offering (ACO).................................................................................... 23
Chapter 4: Simulator Operation .................................................................................................... 24
Simulator Operation .................................................................................................... 24
Restart.........................................................................................................................25
Chapter 5: Reference.................................................................................................................... 26
Status Indications ........................................................................................................ 26
Figure 2 U Interface operation ................................................................................... 26
Figure 3 S/T Interface operation................................................................................ 26
Figure 4 ILS-100 Dimensions and View ................................................................... 27
230VAC Operation ...................................................................................................... 27
Supported Call Control Messages .............................................................................. 28
Typical Call Control Sequence .................................................................................... 29
Figure 5 Call Control Message Exchange example .................................................. 3 0
Troubleshooting .......................................................................................................... 31
Reference Documents ................................................................................................ 34
Warranty and Service ...................................................................................................................... 35
Specifications................................................................................................................................... 37
Glossary ..................................................................................................................................... 39
40-400-00001, Rev. A 1
IMPORTANT SAFETY INSTRUCTIONS
When using your telephone equipment, basic safety precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons, including the following:
1. Read and understand all instructions.
2. Follow all warnings and instructions marked on the product.
3. Unplug this product from the wall outlet before cleaning. Do not use liquid cleaners or aerosol cleaners. Use a damp cloth for cleaning.
4. Do not use this product near water, for example, near a bath tub, wash bowl, kitchen sink, or laundry tub, in a wet basement, or near a swimming pool.
5. Do not place this product on an unstable cart, stand, or table. The product may fall, causing serious damage to the product.
6. Slots and openings in the cabinet and the back or bottom are provided for ventilation. To protect it from overheating, these openings must not be blocked or covered. The openings should never be blocked by placing the product on a bed, sofa, rug, or other similar surface. This product should never be placed near or over a radiator or heat register. This product should not be placed in a built-in installation unless proper ventilation is provided.
7. This product should be operated only from the type of power source indicated on the marking label. If you are not sure of the type of power supply to your home, consult your dealer or local power company.
8. Do not allow anything to rest on the power cord. Do not locate this product where the cord will be abused by persons walking on it.
9. Do not overload wall outlets and extension cords as this can result in fire or electric shock.
10. Never push objects of any kind into this product through cabinet slots as they may touch dangerous voltage points or short out parts that could result in fire or electric shock. Never spill liquid of any kind on the product.
11. To reduce the risk of electric shock, do not disassemble this product, but take it to a qualified serviceman when some service or repair work is required. Opening or removing covers may expose you to dangerous voltages or other risks. Incorrect reassembly can cause electric shock when the appliance is subsequently used.
12. Unplug this product from the wall outlet and refer servicing to qualified service personnel under the follow­ing conditions:
A. When the power supply cord or plug is damaged or frayed. B. If liquid has been spilled into the product. C. If the product has been exposed to rain or water. D. If the product does not operate normally by following the operating instructions. Adjust only those controls that are covered by the operating instructions, because improper adjustment of other controls may result in damage and will often require extensive work by a qualified technician to restore the product to normal operation. E. If the product has been dropped or the cabinet has been damaged. F. If the product exhibits a distinct change in performance.
13. Avoid using a telephone (other than a cordless type) during an electrical storm. There may be a remote risk of electric shock from lightning.
14. Do not use the telephone to report a gas leak in the vicinity of the leak.
2 40-400-00001, Rev. A
SA VE THESE INSTRUCTIONS
Regulatory Compliance
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference in which case the user will be required to correct the interference at his own expense.
COPYRIGHT. The enclosed Software is owned by Teltone Corporation and is protected by copyright law. You must treat the Software like any other copyrighted material (e.g., a book or musical recording) provided that you may either (a) make one copy of the Software for backup or archival purposes, or (b) transfer the Software to a single hard disk provided you keep the original solely for backup or archival purposes.
US GOVERNMENT RESTRICTED RIGHTS. This Product is provided with RESTRICTED RIGHTS. Use, duplication, or disclosure by the Government is subject to restrictions as set forth in subparagraph (c)(1)(ii) of The Rights in Technical Data and Computer Software clause at DF ARS 252.227-7013 or subparagraphs (c)(1) and (2) of The Commercial Computer Software - Restricted Rights at 48 CFR 52.227-19, as applicab le. Manu­facturer is Teltone Corporation, 22121 - 20th Avenue SE, Bothell, Washington, 98021-4408.
Copyright © 1995 Teltone Corporation. Teltone is a registered trademark of Teltone Corporation.
T eltone Corporation 22116-23rd Drive SE Bothell, WA 98021-4413 Phone: 425-487-1515 Fax: 425-487-2288
40-400-00001, Rev. A 3
Introduction
ISDN (Integrated Systems Digital Network) is a system which combines telephone and computer networking in a digital medium. The ISDN BRI (Basic Rate Interface) is the interface for individual users to connect to the public telephone network. An ISDN BRI is composed of three separate channels of information called 2B+D, that is, two full duplex Bearer channels and one full duplex Delta channel combined onto a single pair of wire.
The Teltone ILS-1000 (ISDN Line Simulator) is two ISDN BRI connections in a portable housing. The user interface is either a “U” or an “S/T” connection using an RJ45 modular plug. The “U” connection is similar to the interface that is provided by a local telephone service provider (LEC), such as one of the Bell Operating Compa­nies, or an independent telephone company. The “S/T” connection uses a built in NT-1 (Network Termination 1) to connect to Ter minal Equipment that includes TE1s, TAs, and TE2s. Using these connections, the user is able to place calls, either voice or data, or both, using the National ISDN-1 signalling standard. AT&T 5ESS Custom provisioning is available as a separate option (ILSATT-01).
ISDN is based upon an OSI (Open System Interconnection) model. The ILS-1000 supports layer 1 (physical operation), layer 2 (data link operation), and Layer 3 (network operation.) Layers 4-7 are considered application layers that use the first 3 layers as a base.
The ILS-1000 ISDN Line Simulator has been developed to make the transition from traditional telephony to ISDN networking easier. Software developers, manufactur­ers, integrators, and sales representatives now have an ISDN-BRI The ILS-1000 supports ISDN-BRI end-to-end operation, multiple Call Control protocols, telephony switch services, and simple functional operation on the desktop or lab bench.
server in a box
.
4 40-400-00001, Rev. A
Unpacking
Carefully unpack the items in the shipping container and verify that you have received the following:
1. ILS-1000 ISDN Line Simulator
2. 115 VAC Pow er Cord
3. This User Manual
4. System Configuration Diskette
5. Warranty Registration Card
6. DB9F-DB25M 6-ft RS-232 cable (p/n 742-00022-01)
7. DB9M-DB25F adapter (p/n 742-00020-01)
Optional Accessories:
1. AT&T custom configuration software (diskette) (p/n ILSATT-01)
40-400-00001, Rev. A 5
Chapter 1: Quick Start
The ILS-1000 Line Simulator is easier to operate than most communications devices designed for ISDN-BRI applications. It functions in the background, providing two lines of end-to-end ISDN-BRI service.
Because the Simulator was designed primarily for people who demonstrate, func­tionally test, or configure ISDN-BRI devices, you do not need to understand ISDN protocols or read the entire User’s Manual to use it. Simply follow the instructions outlined below to successfully simulate most ISDN-BRI communications devices and computer applications.
Step 1 Place the Simulator on a flat surface near the ISDN equipment to be
connected.
Step 2 Insert the power cord into the three-pronged outlet located at the rear
of the Simulator. Plug the other end into a standard 115 VAC, 60 Hz wall outlet. NOTE: 230 VAC Power may be used, see Chapter 5 for details.
Step 3 Apply power to the Simulator by pressing the power switch - located
at the rear of the Simulator - to the PWR ON position. An internal self­test, lasting about 30 seconds, is performed. The STATUS LED located on the front panel will switch between Red and Green during this self-test. The STATUS LED changes to a continuous solid green if the self-test is completed satisfactorily.
Step 4 The Simulator is configured at the factory for National ISDN-1 proto-
col. The Simulator is provisioned for default service, as normally practiced for the selected switch type. Most communications devices operate correctly with this provisioning. However, if your communica­tions device does not operate correctly, you may need to change the Simulator’s provisioning. These settings are fully described in Chapter
3. A list of recommended settings for different terminal types (AT&T CUSTOM) is available in the ILS-1000 configuration software.
NOTE: The instructions for many ISDN-BRI communications devices may specify Switch Provisioning required of the tele­phone company. Provisioning is a means of configuring the ISDN switch so it knows what kind and how many calls your communications devices can handle, up to the limits imposed by ISDN-BRI technology. Provisioning also specifies which types of Supplementary Services your equipment may request, such as call appearances, display support, etc.
Step 5 A 3.5" diskette is provided with the ILS-1000 to change the configura-
tion of the ILS-1000. To install this windows based software, place the diskette in the appropriate drive and from Windows Program Manager, select FILE, RUN, A:Setup.
6 40-400-00001, Rev. A
Step 6 After the Simulator’s provisioning is established, press RESTART. The
settings are retained in non-volatile memory until you change them. You now have two ISDN-BRI telephone lines ready to provide Circuit Mode Voice (Speech, 3.1 kHz Audio, 7 kHz Audio), and/or Circuit Mode Data (56 Kbs Restricted, 64 Kbs Clear) services on two B Channels.
Step 7 Refer to the instructions supplied by the manufacturer for installing
your communications device or computer application on an ISDN-BRI telephone line. For most devices, you will use a procedure similar to the following:
NOTE: The instructions may specify that your communications device re­quires power from a secondary source, such as a wall adapter. It may not be necessary to connect a power source when using the Simulator. See Specifi­cations for more details.
Step 8 Determine which ISDN-BRI interface is compatible with your device.
The interface may be either S/T or U. The S/T Interface is commonly called the “Phone” outlet from an NT-1 and is used for most end-user communications devices. However, some adapters and communica­tions devices connect to the U Interface, also called the “Line” outlet. Use 8-Pin Modular (RJ-45) telephone cord for all connections.
IMPORTANT: Either or both Simulator ports may be used during simulation, but only one interface (S/T or U) may be selected at each port. The Simulator auto-detects the active interface. If both interfaces at one port are connected, the Simulator defaults to the S/T interface.
If your communications device is compatible with the S/T Interface, connect to the Simulator’s S/T Interface at either port. Some instructions may require that the device be connected to the “Phone” outlet of an Network Termination-1 (NT-1) device. If you do not have an NT-1 available, use the Simulator’s S/T Interface.
Step 9 If you have an NT-1 and want to install it between your device and the
Simulator, connect the NT-1 “Line” outlet to the Simulator’s U Inter­face at either port. Allow several seconds (5-30) for the port’s U-SYNC light to turn green, then connect your communications device to a “Phone” outlet on the NT-1. Most NT-1’s provide two “Phone” outlets, providing a convenient method for connecting two devices at each Simulator port.
NOTE: The Simulator’s U-SYNC light shows synchronization only for the U Interface. The U-SYNC light is not an indicator for the S/T Interface, which synchronizes in less than a second.
Step 10 Next, you may be instructed to program one or more identification
numbers into your communications device or computer application. The numbers may be a Service Profile ID (SPID) and sometimes a telephone number (Directory Number or DN). The Simulator, like an ISDN switch, expects specific SPID’s and DN’s to be assigned to any particular port. When programming these numbers into your commu­nications device, you must assign the number(s) listed in the following table:
40-400-00001, Rev. A 7
First device at Port 1: SPID 0835866101
DN 835-8661 (1-800-835-8661)
Second device at Port 1: SPID 0835866301
DN 835-8663 (1-800-835-8663)
First device at Port 2: SPID 0835866201
DN 835-8662 (1-800-835-8662)
Second device at Port 2: SPID 0835866401
DN 835-8664 (1-800-835-8664)
NOTE: Not all communications devices are programmed with a SPID or DN. Some devices need an additional number called a Terminal Endpoint Identi­fier (TEI). If you must assign a TEI, use a different number (between 1 and 63) for each device you connect to the Simulator. If automatic TEI assignment is a selectable option, choose it. In short, follow the instructions for your device, using the numbers listed above, when applicable.
Step 11 After any identification numbers are programmed into your device, it
notifies the Simulator using an initialization procedure. If the proce­dure is successful, and your device is connected to the U interface, the U-SYNC LED will light after synchronization is complete.
NOTE: If the U-SYNC LED does not turn on, the device may need to be rebooted or momentarily disconnected (powered down) and reconnected to make it initialize. If the device did not require SPID programming, the U-SYNC LED may not turn on until you place your first call.
Step 12 Repeat the above steps for additional devices. The Simulator provides
power for up to four communications devices and two NT-1’s. Each communications device must be programmed with a different SPID and/or DN.
Step 13 If you later need to rearrange the connections between the Simulator
and your devices, disconnect the devices from the Simulator, press RESTART on the Simulator’s power switch, wait for the STATUS LED to turn to a solid green, then reconnect your devices. If you move a device from one port to another, its SPID and DN must be repro­grammed using available numbers from Table 1. You do not need to restart simulation if you change a device’s SPID or DN when it re­mains at the same port.
IMPORTANT: Some devices let you change the ISDN protocol to support the type of ISDN switch the telephone company has installed. If you change your device’s protocol, you must change the Simulator’s Switch Type configura­tion to match. If you change any one device’s ISDN protocol, then all devices connected to the Simulator must be configured for that protocol.
Step 14 Now you can operate your devices as recommended by the manufac-
8 40-400-00001, Rev. A
turer.
ILS-1000 Operation
When the STATUS LED is a solid green, you can use your communications devices or computer applications as if connected to the telephone company’s ISDN-BRI service.
In general, your ISDN-BRI device will operate the same as conventional telephone equipment, with the obvious exceptions that call processing occurs more rapidly and that voice, high-speed data, and packet mode data may be sent and received simultaneously.
To call from one device to another, you must connect at least two devices to the Simulator. To place a call from device 1 to device 2, dial either the local DN or long distance DN associated with device 2. For example, to call from device 1 (DN= 835-
8661) to device 2 dial the local Directory Number 835-8662 or the long distance number 1-800-835-8662.
If you dial one of the valid Directory Numbers, but no device was assigned to that number, you will hear a ringing tone. If you dial a number assigned to a device that is unable to accept the call, you will hear busy tone and be disconnected after approximately 45 seconds. If you dial a number that is invalid, you will hear a reorder tone (fast busy signal), which means the Directory Number is not in service.
If you dial the number correctly and the device is able to accept the call, the called device begins alerting (rings). When the call is answered, a connection is estab­lished between the devices. You may then talk, transfer files, share computer applications, video conference, exchange e-mail, or perform any other service or feature your ISDN-BRI devices or computer applications support.
If your device supports putting a call on hold or placing multiple calls, you can make additional calls to other devices. You can also make calls in either direction. When you have completed the demonstration, hang up all calls to release their resources.
ISDN-BRI supports up to two connected voice and/or data calls on one line using the B Channels. More than two calls may be present, but any call exceeding the limit of two those that support video conferencing or LAN adaptation, need both B Channels for a single call.
If your communications device requests any of these services, the Simulator pro­vides the necessary processing and resources. A special case, which uses the D Channel and X.25 packet data transmission is also supported and may occur while both B Channels are connected. To enable this ser vice, see Chapter 3 section on D Channel X.25 Packet Handling Function.
Some limitations apply to all ISDN-BRI communications, however. For example, if two devices are connected to a single line and you establish a call between them, both B Channels at that line are allocated to connect the call. In other words, both B Channels are “busy” during one connected call. Consequently, any device that uses two B Channels for a single call, such as a video conferencing application, cannot connect to another device on the same line.
connected
calls must be placed on hold. Some devices, particularly
40-400-00001, Rev. A 9
Another limitation occurs when attempting to place a call to a device that does not support the requested call type. For example, a call placed from an ISDN data terminal to an ISDN voice telephone will be rejected by the telephone.
In some cases, the call type and number of channels are satisfied and the called device answers the call, but the calling application is not compatible with the called application. For example, not all video conferencing applications use the same data encoding. Or, a Terminal Adaptor that converts ISDN to RS-232 may answer a data call that is carrying FAX information. A well-designed application determines that it cannot process the data and releases the call. Otherwise the user must hang up.
What To Read Next
For a technical review of ISDN-BRI operation, including physical layer indications, data link packet protocol, and call control signaling, read Chapter 2.
For a comprehensive review of Simulator provisioning, read Chapter 3. For more details about Simulator operation , read Chapter 4. For troubleshooting guidelines, technical references, read Chapter 5.
10 40-400-00001, Rev. A
Chapter 2: ISDN-BRI
Technology Overview
The Integrated Services Digital Network - Basic Rate Interface (ISDN-BRI) is a technology that gives individuals affordable access to the world’s largest digital network using the copper wire currently entering their home or office. With ISDN­BRI, users may connect almost any form of personal communications device to a single phone line and establish multiple, simultaneous voice and data connections at speeds up to 128 thousand bits per second.
ISDN is an extremely robust networking technology based on the Open Systems Interconnection (OSI) model set forth in the International Standards Organization specification, ISO84.
The OSI model specifies a layered design architecture. Layer 1, or the physical layer, consists of two new interfaces, referred to as the 2, or the data link layer, is a packet transport protocol known as
col - D Channel
Layer 3, or the network layer, is a flexible switching and signaling language referred to as
ISDN Call Control
The ILS-1000 is configured to support the first three layers of the OSI model.
U and S/T Interfaces
Link Access Proto-
(LAP-D), which was adapted from ITU-T Recommendation X.25.
.
. La y e r
ISDN services are referred to as Voice (CMV), Circuit Mode Data (CMD), and Packet Mode Data (PMD). Circuit mode call types support high-speed data and digitized voice, while packet mode calls may be used for computer networking.
All ISDN-BRI user traffic travels over two 64Kbs
Channel
is always used for transporting Call Control signaling packets between the ISDN switch in the central office and the end-user communications device. The B and D Channels may optionally transport user Packet Mode Data.
. The B Channels are always used for circuit mode calls and the D Channel
Call Types
. Common call types are Circuit Mode
B Channels
and one 16Kbs
D
Layer 1 - Physical Operation
Typical ISDN-BRI terminations and interfaces are shown in Chapter 5. Each inter­face, which the telephone company terms a specific task.
U Reference Point
This interface connects the central office to the customer’s premises. It is a 160Kbs, two-wire, bidirectional transmission path that employs 2B1Q encoding to endure long distances. It is designed to provide as much bandwidth as possible over existing copper wire pairs. The U interface signal carries two B channels, one D channel, overhead bits for framing and echo cancellation, and an
tions Channel
(EOC) for testing and monitoring.
reference point
, is designed for a
Embedded Opera-
40-400-00001, Rev. A 11
Network Termination-1 (NT-1)
The U Interface terminates at a device called a This device converts the U Interface to an S/T Interface. It also permits loop back and testing by the telephone company and a means of routing local power to devices previously designed to receive power from the line, such as a telephone.
S/T Reference Point
This interface is a 192 Kbs, four-wire path; two wires are used for transmission, two for reception. The encoding scheme is ASI bipolar. Unlike the U Interface, it syn­chronizes quickly. All ISDN-compatible user devices, or
ment
(TE-1), are connected directly to the S/T interface.
Terminal Adapters
To accommodate a variety of communications equipment, the S/T interface may be connected to a sion from an older or proprietary interface, such as RS-232 or a Local Area Network (LAN) protocol, to an ISDN-BRI S/T Interface. Devices that connect to a TA are called
Type 2 Terminating Equipment
Terminal Adapter
(TA). This device provides any necessary conver-
(TE-2).
Network Termination-1
Type 1 Terminating Equip-
, or NT-1.
Layer 2 - Data Link Operation
Layer 2 of the OSI model establishes a method of transporting binary information via data links. The ISDN data link layer is a variant of X.25 packet exchange called
LAP-D
. All signaling and switching information (Layer 3), and optionally X.25 LAP-B user data, are transported on the D Channel using this protocol. LAP-D packets are of variable length, and are bounded by a flag pattern and terminated with a cyclic redundancy checksum.
There are three categories of packet. Unnumbered Information (UI) packets carry LAP-D protocol commands. These commands establish addresses, initiate se­quenced packet exchanges, or negotiate various protocol parameters. Numbered Information (I) packets carry Layer 3 Call Control messages or X.25 LAP-B user data. These packets are given sequence numbers, referred to as Next Send (NS) and Next Receive (NR), which ensure delivery in correct order. Supervisory (S) packets acknowledge or reject sequenced I packets.
Packet Addressing
Each packet is given an address consisting of two numbers. The first number, called a or destinations within a device. SAPI 0 addresses Call Control functions, and SAPI 16 addresses the data.
SAPI 63 addresses the assigns the second packet address number, called a TEI. The TEI is a unique number for each Terminating Equipment on a particular line. For example, if a packet addressed to SAPI 0 and TEI 3 is sent to four ISDN devices connected to a single line, only the Call Control function (SAPI 0) of the device assigned TEI 3 will acknowledge and process the packet.
Service Access Point Identifier
Packet Handling Function
Signaling Access Controller
or SAPI, addresses one of three
(PHF) associated with X.25 LAP-B user
(SAC), which negotiates and
logical links
Terminal Endpoint Identifier
or
12 40-400-00001, Rev. A
TEI Assignment
Most ISDN Terminating Equipment support a feature called automatic TEI assign­ment. After a device is connected and synchronized, packets are exchanged with the switch to establish the TEI. The switch knows which TEI’s are assigned to that line and can query each device if in doubt. A unique TEI between 64 and 126 is then formulated and returned to the requesting device. TEI 127, the default broadcast TEI, is used for this operation. Some switches or devices do not support automatic assignment, however. The user is then responsible for configuring the device with a unique
fixed TEI
between 1 and 63.
Layer 3 - Network Operation
Once packet exchange is established, the Network Layers of the switch and Termi­nating Equipment can begin the Call Control dialog that replaces conventional telephony signaling. The dialog is based on a set of commands that operate on one or more parameters, similar to a computer Operating System language. Commands are called are over 45 Messages and 65 Information Elements currently used by North Amer i­can ISDN telephone networks. Information elements may contain between one and over 100 bytes of constant or variable data.
For example, the SETUP Message initiates an incoming or outgoing call on de­mand. Several Information Elements are contained in a SETUP Message, and each are expected to be a particular value or variable type. The SETUP Message usually contains the Elements, among others. The Channel ID determines which B or D Channel is used for the connection. The Bearer Capability describes the call as voice, high-speed data, or packet mode data and sets the data rate and other parameters. The Calling Party Number is the caller’s Directory Number in ASCII code.
Messages
Channel ID, Bearer Capability
and parameters are called
, and
Information Elements
Calling Party Number
(IE). There
Information
Other Messages and Information Elements enable tones, transport keypad num­bers, alert the called par ty, connect the call across the network, and disconnect the call and release its resources when either party hangs up. Standardized Message types and Information Elements are listed in Chapter 5. Call Control is extensible, however, and the number of Messages and Information Elements continues to increase.
Multiple versions of ISDN Call Control currently exist. Two common ISDN switches use proprietary Call Control: Northern Telecom’s DMS-100 series and AT&T’s 5E series. The Call Control standard to which these switches are being upgraded and to which current switches are designed is called Economic Community, (ECC) is currently consolidating various national versions to comply with the European Telecommunications Standards Institute (ETSI) protocol.
Consequently, Messages and Information Elements may differ in function and coding, depending on the switch and the vintage. A special Message, NETwork ESCape, is implemented to alert the switch when a proprietary Message coding is used. Information Element codings that are not yet adopted by the ITU-T are preceded by a
Unfortunately, these practices do not ensure that all switches recognize all devices. Any Message that is not recognized by the switch is ignored. For this reason, not all ISDN equipment is compatible at all locations.
Locking Shift
Information Element.
National ISDN-1
. The European
40-400-00001, Rev. A 13
Service Profile ID (SPID) Assignment
Normally, each telephone line is assigned a single Directory Number. When a customer orders services or features, they are programmed into a
Service Profile
stored at the switch. Any call associated with that line can be assumed to apply only to that customer’s Directory Number and Service Profile. When a single ISDN device is connected and serviced this way, the configuration is said to be
point
.
point-to-
However, ISDN also supports
point-to-multipoint
configurations, with multiple but dissimilar devices connected to a single line. In many cases, is not desirable to share the same Directory Number and Service Profile. Consequently, ISDN relies on an initialization procedure for associating Service Profiles with individual Terminating Equipment, rather than lines.
Terminating Equipment that support this procedure are said to be
Auto-Initializing.
The phone company gives an ISDN customer a Service Profile ID (SPID) up to twenty digits long. The customer programs the number into the Te r minating Equip­ment, which sends it to the switch. The switch associates the SPID with a specific Service Profile and Directory Number, and returns a corresponding
Endpoint ID
to the Terminating Equipment. When the switch sends SETUP Messages to a line configured point-to-multipoint, it includes the Endpoint ID, and only matching Ter mi­nating Equipment respond.
NOTE: NI-1 Switch Types are always configured for multi-point operation.