TellCard Systems EMR KB/KU-AP, EMR KB/KU-SC, EMR KB/KU-PR, EMR KB/KU-OF, EGT/E6291(2) KB/KU1(2) Programming Manual

1
EMR KB/KU – AP/OF/SC/PR Programming Manual
GR1 Mortise Offline Lockset
88307 Rev 0
Firmware Rev 1.0.0
Table of Contents:
EMR KB/KU – AP/OF/SC/PR Features....................................................................Page 2
EMR KB/KU – AP/OF/SC/PR Quick Start Guide......................................................Page 4
EMR KB/KU – AP/OF Configuration Overview.........................................................Page 5
EMR KB/KU – AP/OF Manage Users.......................................................................Page 6
EMR KB/KU – AP/OF Configure Lock Functions......................................................Page 8
EMR KB/KU – AP/OF Configure Settings.................................................................Page 9
EMR KB/KU – AP/OF Reset Options........................................................................Page 11
EMR KB/KU – AP/OF Troubleshooting.....................................................................Page 12
EMR KB/KU SC Configuration Overview..................................................................Page 13
EMR KB/KU SC Manage Users................................................................................Page 14
EMR KB/KU SC Configure Lock Functions...............................................................Page 16
EMR KB/KU SC Configure Settings..........................................................................Page 18
EMR KB/KU SC Troubleshooting..............................................................................Page 20
EMR KB/KU PR Configuration Overview..................................................................Page 21
EMR KB/KU PR Manage Users................................................................................Page 22
EMR KB/KU PR Configure Lock Functions...............................................................Page 24
EMR KB/KU PR Configure Settings..........................................................................Page 25
EMR KB/KU PR Troubleshooting..............................................................................Page 27
EMR KB/KU – SC/PR Reset Options........................................................................Page 28
EMR KB/KU – AP/OF/SC/PR Sample User Chart.....................................................Page 29
FCC Statement
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
EMR KB/KU –
AP/OF/SC/PR Table of Contents
2
Lockset Features
100 users plus one master code
Change function of lock electronically
Emergency Lockdown
EMR KB/KU – AP/OF: Relock
EMR KB/KU – SC:
o Storeroom (Relock) o Classroom (Passage Toggle) o Classroom (Passage Toggle) Timer o Permanent Passage
EMR KB/KU – PR:
o Faculty Privacy (Relock) o Service Station (Passage Toggle) o Service Station (Passage Toggle) Timer
Power options:
o Battery operated with 4 AA Alkaline batteries, or o 12V to 24V DC power input, or o 12V to 24V AC power input
Minimum 100,000 cycles or one year per set of batteries
Low battery warning
Non-volatile memory
All programming entered through keypad
Valid code is 4-8 digits. Digits may be repeated. Codes may start with zero (0)
Entry of three invalid user codes temporarily disables all codes
Mute function: Beeper may be audible or muted
No user numbers to track; user number is access code
Duplicate codes not allowed
Backlit keypad
EMR KB/KU –
AP/OF/SC/PR Features
3
Factory Default Settings
Function:
o AP/OF – Relock o SC – Storeroom (Relock) o PR – Faculty Privacy (Relock)
Sound: ON
Unlock length: 4 seconds
Anti-Tamper Lockout Delay Time: 20 seconds
Power Requirements
Power may be supplied in one of three ways:
Four AA alkaline batteries, or
Hard wired to 12V to 24V DC power supply, or
Hard wired to 12V to 24V AC power supply
External power requirements:
Voltage: 12 to 24VDC or 12 to 24VAC
Current: 0.30 A/12VDC; 0.30 A/24 VDC
EMR KB/KU AP/OF/SC/PR Features
(Cont’d)
4
Install battery pack.
1. After initial battery pack installation, LEDs above keypad will flash rapidly, indicating lock is waiting to accept a master code.
2. Door is unlocked until a valid master code is entered.
Set Master Code Key Stroke Example
1. Key in a master code with any 4-8 digits.
2. Press *.
DEVICE IS NOW LOCKED AND OPERATIONAL WITH MASTER CODE.
Understanding Light and Beeper Feedback:
Success: Two short beeps and green LED
Error: Long beep and red LED
Low battery: Success beep immediately followed by long error beep
Factory reset: Lights rapidly flashing
Keypad Backlighting:
Press and hold any number key to illuminate the keys. Backlight will automatically turn off after 5 seconds of inactivity.
EMR KB/KU –
AP/OF/SC/PR Quick Start Guide
2
1
3 4
5
Steps to Fully Configure Lock for EMR KB/KU - AP/OF
Setting Master Code
1. After initial battery pack installation LEDs above keypad will flash rapidly indicating lock is waiting to accept master code. To conserve battery, LEDs will flash for two minutes.
2. Door is unlocked until a valid master code is entered.
3. Choose and enter a 4-8 digit master code. Press * to complete.
4. Device locks after master code is entered.
DEVICE IS NOW LOCKED AND OPERATIONAL WITH MASTER CODE. Function Overview:
Mode Lock Function
Page Number
0
Emergency Lockdown – Mode 0 Page 8
1
Relock – Mode 1 Page 8
Mode
Lock Setting
Page Number
4
Unlock Delay Time
Page 9
5
Lockout Delay Time
Page 9
6
Remote Release Functionality
Page 10
7
Sound
Page 10
8
Single and Limited Use Code(s)
Page 7
Reset
Reset Options
Page 11
EMR KB/KU –
AP/OF Configuration Overview
6
Set Master Code Key Stroke Example
1. Key in a master code with any 4-8 digits.
2. Press *.
Manage Codes
Valid new user codes are stored with each press of the # key, which results in a successful entry tone. Pressing the * key exits the programming mode.
When entering a string of codes, all valid codes are immediately stored with each press of the # key. If a code is rejected, all valid codes preceding the rejected code are stored in memory.
Key Stroke Example
Add Single
User Code
1. Key in master code.
2. Press #.
3. Key in new code.
4. Press #.
5. Press *.
Add Multiple
User Codes
1. Key in master code.
2. Press #.
3. Key in 1st new code.
4. Press #.
5. Key in 2nd new code.
6. Press #, then *.
Delete Single
User Code
1. Key in master code.
2. Press #.
3. Key in code to delete.
4. Press *.
Delete All
User Codes
1. Key in master code.
2. Press #.
3. Press 10, then #.
4. Press 1, then *.
Delete All
Single and
Limited User
Codes (Regular
codes are
not affected.)
1. Key in master code.
2. Press #.
3. Press 10, then #.
4. Press 2, then *.
2
1
3 4
2
EMR KB/KU –
AP/OF Manage Users
2
1
3 4
#
1 1 2 2 3 3
#
2
1
3 4
#
2 2 3 3 4
4 #
1
1
2 2 3
3 #
1 1 2 2 3
3
2 1 3 4
#
2 1 3 4
#
10
1
#
2
1
3 4
#
10
2
#
7
Single Use Code(s) – Function 8
Single Use Code(s) - Function 8 allows a single entry. When used, the code is immediately erased from memory. Single use code(s) are entered one at a time. Multiple single use codes cannot be entered in a string like the standard user codes.
Key Stroke Example
Single
Use
Code(s) –
Function 8
1. Key in master code.
2. Press #.
3. Press 8.
4. Press #.
5. Key in new code.
6. Press *.
Limited Use Code(s) – Function 8
Limited Use Code(s) - Function 8 allows the user to enter a code for a configurable number of times; minimum number of entries is 1, maximum is 9.The code is erased from memory im­mediately after the last allowed access event. Limited use code(s) are entered one at a time. Multiple limited use code(s) cannot be entered in a string like the standard user codes.
Key Stroke Example
Limited
Use
Code(s) –
Function 8
1. Key in master code.
2. Press #.
3. Press 8.
4. Press #.
5. Key in new code.
6. Press #.
7. Press X (1-9 entries allowed)
8. Press, then *.
# 8
1 1 2 2 3 3
2 1 3 4
#
#
8 1 1 2 2 3 3
#
X
2
1
3 4
#
EMR KB/KU AP/OF Features
(Cont’d)
8
The EMR KB/KU – AP/OF lock has two operational modes (functions): Emergency Lockdown – Mode 0, and Relock – Mode 1. The factory default setting is Relock – Mode 1.
Emergency Lockdown – Mode 0
In Emergency Lockdown – Mode 0, the lock temporarily disables all user codes except the master code, and immediately locks the door. A master code or optional remote release temporarily unlocks door to allow entry, then relocks.
1. Enter master code, followed by #.
2. Press zero (0).
3. Press *.
Key Stroke Example
Emergency
Lockdown –
Mode 0
1. Key in master code.
2. Press #.
3. Press zero (0).
4. Press *.
Relock – Mode 1
In Relock – Mode 1, the lock will unlock for 4 seconds, then relock. This mode is used when you want the lock to remain secure at all times. Setting the device to Relock – Mode 1 immediately secures the door.
1. Enter master code, followed by #.
2. Press 1.
3. Press *.
OF Lock: Relock – Mode 1: Rotating thumbturn on inside puts lock into extended Passage Mode (unlocks) until thumbturn is returned to home position securing the lock.
Key Stroke Example
Relock –
Mode 1
1. Key in master code.
2. Press #.
3. Press 1.
4. Press *.
EMR KB/KU –
AP/OF Configure Lock Functions
2
1
3 4 0
#
2
1
3 4 1
#
9
Unlock Delay Time
The Unlock Delay Time function sets the number of seconds the lock remains unlocked when in Relock – Mode 1. The default time is 4 seconds; minimum is 1 second, maximum is 99 seconds.
Key Stroke Example
Unlock
Delay Time Default =
4 seconds X = Time Choice
(Seconds)
1. Key in master code.
2. Press #.
3. Press 4.
4. Press #.
5. Press X (Time Choice).
6. Press *.
Lockout Delay Time
The Lockout Delay Time function sets the number of seconds the lock will disallow keypad entry after three unsuccessful code entries. The default time is 20 seconds, zero (0) seconds disables the feature; maximum is 99 seconds.
Key Stroke Example
Locked
Delay Time Default =
20 seconds X = Time Choice
(Seconds)
1. Key in master code.
2. Press #.
3. Press 5.
4. Press #.
5. Press X (Time Choice).
6. Press *.
EMR KB/KU – AP/OF Configure Settings
2
1
3 4 4
#
#
X
2 1 3 4 5
# #
X
Loading...
+ 21 hidden pages