Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights
Reserved. Page 2 of 38
SPECIFICATIONS SUBJECT TO CHANGE WITHOut Notice
Notice
While reasonable efforts have been made to assure the accuracy of this document, Telit
assumes no liability resulting from any inaccuracies or omissions in this document, or from
use of the information obtained herein. The information in this document has been carefully
checked and is believed to be entirely reliable. However, no responsibility is assumed for
inaccuracies or omissions. Telit reserves the right to make changes to any products described
herein and reserves the right to revise this document and to make changes from time to time
in content hereof with no obligation to notify any person of revisions or changes. Telit does
not assume any liability arising out of the application or use of any product, software, or
circuit described herein; neither does it convey license under its patent rights or the rights of
others.
It is possible that this publication may contain references to, or information about Telit
products (machines and programs), programming, or services that are not announced in your
country. Such references or information must not be construed to mean that Telit intends to
announce such Telit products, programming, or services in your country.
LE51-868 S RF Module User Guide
1VV0301131Rev.0 – 2014-01-16
Copyrights
This instruction manual and the Telit products described in this instruction manual may be,
include or describe copyrighted Telit material, such as computer programs stored in
semiconductor memories or other media. Laws in the Italy and other countries preserve for
Telit and its licensors certain exclusive rights for copyrighted material, including the
exclusive right to copy, reproduce in any form, distribute and make derivative works of the
copyrighted material. Accordingly, any copyrighted material of Telit and its licensors
contained herein or in the Telit products described in this instruction manual may not be
copied, reproduced, distributed, merged or modified in any manner without the express
written permission of Telit. Furthermore, the purchase of Telit products shall not be deemed
to grant either directly or by implication, estoppel, or otherwise, any license under the
copyrights, patents or patent applications of Telit, as arises by operation of law in the sale of a
product.
Computer Software Copyrights
The Telit and 3rd Party supplied Software (SW) products described in this instruction manual
may include copyrighted Telit and other 3rd Party supplied computer programs stored in
semiconductor memories or other media. Laws in the Italy and other countries preserve for
Telit and other 3rd Party supplied SW certain exclusive rights for copyrighted computer
programs, including the exclusive right to copy or reproduce in any form the copyrighted
computer program. Accordingly, any copyrighted Telit or other 3rd Party supplied SW
computer programs contained in the Telit products described in this instruction manual may
not be copied (reverse engineered) or reproduced in any manner without the express written
permission of Telit or the 3rd Party SW supplier. Furthermore, the purchase of Telit products
shall not be deemed to grant either directly or by implication, estoppel, or otherwise, any
license under the copyrights, patents or patent applications of Telit or other 3rd Party supplied
SW, except for the normal non-exclusive, royalty free license to use that arises by operation
of law in the sale of a product.
Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights
Reserved. Page 3 of 38
LE51-868 S RF Module User Guide
1VV0301131Rev.0 – 2014-01-16
Usage and Disclosure Restrictions
License Agreements
The software described in this document is the property of Telit and its licensors. It is
furnished by express license agreement only and may be used only in accordance with the
terms of such an agreement.
Copyrighted Materials
Software and documentation are copyrighted materials. Making unauthorized copies is
prohibited by law. No part of the software or documentation may be reproduced, transmitted,
transcribed, stored in a retrieval system, or translated into any language or computer language,
in any form or by any means, without prior written permission of Telit
High Risk Materials
Components, units, or third-party products used in the product described herein are NOT
fault-tolerant and are NOT designed, manufactured, or intended for use as on-line control
equipment in the following hazardous environments requiring fail-safe controls: the operation
of Nuclear Facilities, Aircraft Navigation or Aircraft Communication Systems, Air Traffic
Control, Life Support, or Weapons Systems (High Risk Activities"). Telit and its supplier(s)
specifically disclaim any expressed or implied warranty of fitness for such High Risk
Activities.
Trademarks
TELIT and the Stylized T Logo are registered in Trademark Office. All other product or
service names are the property of their respective owners.
For detailed information about where you can buy the Telit modules or for recommendations
on accessories and components visit:
http://www.telit.com
To register for product news and announcements or for product questions contact Telit
Technical Support Center (TTSC).
Our aim is to make this guide as helpful as possible. Keep us informed of your comments and
suggestions for improvements.
Telit appreciates feedback from the users of our information.
1.4. Document Organization
This document contains the following chapters
“Chapter 1: “Introduction” provides a scope for this document, target audience, contact and
support information, and text conventions.
“Chapter 2: “Requirements” gives an overview of the limitations imposed by Reference
standards.
“Chapter 3: “General Characteristics” describes in detail the characteristics of the product.
Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights
Reserved. Page 7 of 38
“Chapter 4: “Technical Description” describes in detail the signals and pin-out of the product.
“Chapter 5: “Process information” describes in detail the delivery, storage, soldering and
placement of the product.
“Chapter 6: “Board Mounting Recommendations” describes in detail the interface and
coupling of the product.
“Chapter 8: “Glossary” shows acronyms used in the document.
“Chapter 9: “Document history” describes the revision history of the document.
1.5. Text Conventions
Danger – This information MUST be followed or catastrophic equipment failure or bodily
injury may occur.
LE51-868 S RF Module User Guide
1VV0301131Rev.0 – 2014-01-16
Caution or Warning – Alerts the user to important points about integrating the module, if
these points are not followed, the module and end user equipment may fail or malfunction.
Tip or Information – Provides advice and suggestions that may be useful when
integrating the module.
All dates are in ISO 8601 format, i.e. YYYY-MM-DD.
Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights
Reserved. Page 8 of 38
1.6. Related Documents
• [1] EN 300 220-2 v2.4.1, ETSI Standards for SRD , May 2012
• [2] ERC Rec 70-03, ERC Recommendation for SRD, October 2012
• [3] 2002/95/EC, Directive of the European Parliament and of the Council, 27 January 2003
• [4] SR Tool User Guide, 1vv0300899
• [5] 2006/771/EC, Harmonization of the radio spectrum for use by short-range devices
• [6] 2009/381/EC, Amending Decision 2006/771/EC on harmonization of the radio
spectrum for use by short-range devices
• [7] Sigfox Stand-Alone Module User Guide, 1vv0301109
LE51-868 S RF Module User Guide
1VV0301131Rev.0 – 2014-01-16
Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights
Reserved. Page 9 of 38
Band g3
869.400
– 869.650
500 25 kHz or the whole band
10
2. Requirements
2.1. General Requirements
The LE51-868 S module is a multi-channel radio board, delivering up to 35 mW in the 868
MHz ISM band (unlicensed frequency band).
It is delivered with preloaded protocol stack:
• LE51-868 S SIGFOX™ Network Software.
LE51-868 S is pin-to-pin compatible with LE, NE and ME modules working at different
frequencies.
LE51-868 S is also pin-to-pin compatible with Telit ZE Family (ZigBee 2007 and ZigBee
PRO stack).
LE51-868 S RF Module User Guide
1VV0301131Rev.0 – 2014-01-16
2.2. 868 MHz band Requirements
The “ERC recommendation 70-03” describes the different usable sub-bands in the 868 MHz
license free band, in terms of bandwidth, maximum power, duty cycle and channel spacing.
LE51-868 S can operate on Annex 1, g1 band where “ERC recommendation 70-03” gives the
following limitations:
This band is free to use but the module and the user must respect some limitations. Most of
these restrictions are integrated in the conception of the module, except the duty cycle. For
example, the g1 sub-band from 868.000 to 868.600 MHz band is limited to a 1% duty cycle.
This means that each module is limited to a total transmit time of 36 seconds per hour. It is
the responsibility of the user to respect the duty cycle. Sigfox has also a limitation on this
band to ensure unsaturated network.
In order to fulfil the ETSI 70-03 specification requirement regarding duty cycle on ISM band
and to be aligned with Sigfox network management, each hour the application can send up to
72 Bytes (e.g., 6 messages of 12 bytes each).
Maximum radiated
power (mW)
Channel spacing
(kHz)
Duty cycle
(%)
Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights
Reserved. Page 10 of 38
Furthermore, the module complies with the ETSI 300-220-2 v2.3.1 standards (specific for
SRD) whose main requirements are described in Appendix 1.
Finally, the module complies with the European Directive 2002/95/EC concerning the
Restrictive Usage of Hazardous Substances (RoHS).
Country
Restriction
Reason/Remark
Spain
Limited implementation
to the band 863
-
868 MHz
The Netherlands
Not Implemented
Under stu
dy
LE51-868 S RF Module User Guide
1VV0301131Rev.0 – 2014-01-16
National Restrictions for non specific SR devices Annex 1 band g1-g4:
Band G
Austria Not Implemented Planned
Finland Limited Implementation
Audio, video and voice not allowed Planned 2011
Georgia Not Implemented
Sweden Not Implemented
Ukraine Limited implementation
Band G1
Georgia
Russian
Federation
Not Implemented
Not Implemented
863-865 / 868-868.6 / 868.6-868.7 /
869.2-869.25 MHz
Ukraine Not Implemented e.i.r.p. ≤25 mW
2.3. Other Requirements
The module complies with the European Directive 2002/95/EC concerning the Restrictive
Usage of Hazardous Substances (RoHS).
2.4. Functional Requirements
The LE51-868 S module is a complete solution from serial interface to RF interface. The
LE51-868 module has a digital part and a RF part. The radio link on Sigfox network is a
mono-directional link, since RX features are not required to be compliant with the network
protocol.
The digital part has the following functionalities:
Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights
Reserved. Page 11 of 38
Operating
LE51-868 S RF Module User Guide
• Packet handling
2.5. Software
The LE51-868 S module is provided pre-flashed with one of the available Telit in-house
Protocol Stack.
Please refer to Protocol Stack User Guide [7] for detailed information.
2.6. Temperature Requirements
Minimum Typical Maximum Unit
Temperature - 40 25 + 85 °C
Relative humidity @
25°C
Storage
Temperature - 40 25 + 85 °C
20 75 %
1VV0301131Rev.0 – 2014-01-16
Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights
Reserved. Page 12 of 38
LE51-868 S RF Module User Guide
1VV0301131Rev.0 – 2014-01-16
3. General Characteristics
3.1. Mechanical Characteristics
Size :
Height :
Weight :
PCB thickness:
Cover* :
Components :
Connectors :
Mounting :
Number of pins :
Rectangular 25.8 x 15 mm
3 mm
1.7 g
0.8 mm
• Dimensions : 25 x 14.2 x 2.2mm
• Thickness : 200µm
All SMD components, on one side of the PCB.
The terminals allowing conveying I/O signals are LGA
• SMD
• LGA on the 4 external sides
30
*: The metallic shield used on LE51-868 S covers all the SMD components
Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights
Reserved. Page 13 of 38
3.2. Mechanical dimensions
LE51-868 S RF Module User Guide
1VV0301131Rev.0 – 2014-01-16
Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights
Reserved. Page 14 of 38
LE51-868 S RF Module User Guide
3.3. Recommended Land pattern
3.4. DC Characteristics
1VV0301131Rev.0 – 2014-01-16
Measured on DIP interface with T = 25°C, Vdd = 3V, 50Ω impedance and default power
register setting if nothing else noted.
Max limits apply over the entire operating range, T=-40°C to +85°C, Vdd=2V to 3.6V and all
channels.
Characteristics LE51-868 S Min. Typ. Max.
Power Supply
(VDD):
Consumption
Stand-by (32.768 kHz On) :
I/O low level :
I/O high level :
Transmission:
Command/Data mode
Reception :
+2.0V +3.0V +3.6V
55mA@25mW 66mA@35mW
11mA 13mA
TBD < 2uA
GND - 0.2x V
0.8x V
DD
- V
DD
DD
Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights
Reserved. Page 15 of 38
LE51-868 S RF Module User Guide
1VV0301131Rev.0 – 2014-01-16
3.5. LE51-868 S Functional Characteristics
Measured on DIP interface with T = 25°C, Vdd = 3V, 50Ω impedance and default power
register setting if nothing else noted.
Frequency Band 868.178 MHz – 868.222 MHz
RF Data Rate 100 bps
Number of channels 1
Total slot number 480
Slot Width 100 Hz
Blacklisted slots
Center Frequency 868.2 MHz
Total Bandwidth 48 kHz
Modulation Format (D)BPSK
Technology Sigfox Protocol
RF Output Power
0 to 19; 221 to 259; 460 to 480
Transmission
Up to 30mW @3.0 Volts
Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights
Reserved. Page 16 of 38
LE51-868 S RF Module User Guide
1VV0301131Rev.0 – 2014-01-16
Limits allowed by ETSI Standard are reported in the table below:
Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights
Reserved. Page 17 of 38
3.6. Digital Characteristic
Function Characteristics
• 128 kB + 8 kB in system programmable flash
µC
Serial link
• 8 kB RAM
• 2 kB E2PROM
• RS232 TTL Full Duplex
• 1200 to 115200 bps
• 7 or 8 bits
• Parity management
• Flow control
o Hardware (RTS/CTS)
LE51-868 S RF Module User Guide
1VV0301131Rev.0 – 2014-01-16
Embedded software
functionality
• Flexibility:
o Pre flashed
o Customization capability
o Download over the air
3.7. Absolute Maximum Ratings
Voltage applied to Vcc, VDD :
Voltage applied to “TTL” Input :
-0.3V to +3.6V
-0.3V to VDD+0.3V
Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights
Reserved. Page 18 of 38
3.8. Ordering Information
The following equipments can be ordered:
• The SMD version (LE51-868 S)
• The DIP interface version (LE51-868 S)
• The Demo Case (LE51-868 S) composed by n.1 evaluation boards, n.1 DIP interface
boards, RF antennas, serial cable, battery.
The versions below are considered standard and should be readily available. For other
versions, please contact Telit. Please make sure to give the complete part number when
ordering.
LE51-868 S RF Module User Guide
1VV0301131Rev.0 – 2014-01-16
Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights
Reserved. Page 19 of 38
B
LE51
-
868 S
LE51-868 S RF Module User Guide
1VV0301131Rev.0 – 2014-01-16
Equipment
SMD Version
LE51-868 S/SMD
DIP Version
Demo Case
D LE51-868 S
Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights
Reserved. Page 20 of 38
LE51-868 S RF Module User Guide
1VV0301131Rev.0 – 2014-01-16
4. Technical Description
4.1. Module Top View (cover side)
CAUTION: reserved pins must not be connected
CAUTION: In case you want to use in the same application Telit ZE51 or ZE61 modules
J9 and J8 should not be connected, since reserved on these modules (see foot notes on PinOut tables.
Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights
Reserved. Page 21 of 38
LE51-868 S RF Module User Guide
1VV0301131Rev.0 – 2014-01-16
4.2. Pin-out of the module LE51-868 S
Pin Pin name Pin type Signal level Function
J30 GND Gnd RF Ground connection for external antenna
J29 Ext_Antenna RF RF I/O connection to external antenna
J28 GND Gnd RF Ground connection for external antenna
J27 GND Gnd Ground
J26 GND Gnd Ground
J25 VDD Power Digital and Radio part power supply pin
J24 CTS I TTL Clear To Send
J23 RESET I TTL µC reset ( Active low with internal pull-up )
J22 RTS O TTL Request To Send
J21 RXD I TTL RxD UART – Serial Data Reception
J20 GND Gnd Ground
J19 TXD O TTL TxD UART – Serial Data Transmission
J18 WAKEUP I TTL Wake-up (Active high with internal pull-down: when set to 1 the
J17 GND Gnd Ground
J16 PROG I TTL Signal for serial µC flashing (Active high with internal pull-down)
J15 GND Gnd Ground
J14 PDI_DATA I/O TTL Program and Debug Interface DATA
J13 GND Gnd Ground
J12 GND Gnd Ground
J11 GND Gnd Ground
J10 PDI_CLK I TTL Program and Debug Interface CLOCK
J9
IO91
J8
IO8_A
J7 IO7_A I/O analog Analog Input N°7 (Logic I/O capability)
J6 IO6_A I/O analog Analog Input N°6 (Logic I/O capability)
J5 IO5_A I/O analog Analog Input N°5 (Logic I/O capability)
J4 IO4_A I/O analog Analog Input N°4 (Logic I/O capability)
J3 IO3_A I/O analog Analog Input N°3 (Logic I/O capability)
J2 STANDBY
STATUS
J1 RADIO STATUS O TTL
I/O
I/O
O TTL
TTL
analog
module is awakened)
Digital I/O N°9 with interrupt
Analog Input I/O N°8 with interrupt (Logic I/O capability)
Signal indicating stand-by status
Signal indicating reception or transmission of radio frame
1, 2
In case you want to use in the same application Telit ZE51 or ZE61 modules J9 and J8 should not be connected, since
reserved on these modules.
Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights
Reserved. Page 22 of 38
LE51-868 S RF Module User Guide
1VV0301131Rev.0 – 2014-01-16
4.3. Pin-out of the DIP Interface
Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights
Reserved. Page 23 of 38
LE51-868 S RF Module User Guide
1VV0301131Rev.0 – 2014-01-16
4.4. Pin-out correspondence table
Pin-Out correspondence between LE51-868 S/DIP and LE51-868 S/SMD.
LE51-868 S/DIP LE51-868 S/SMD Comments
Connector Pin Name Pin Pin Name
1
2 GND
3 P1 J5 IO5_A
4 P2 J9 IO9_I Reserved Pin
J1
J2
J4
RF connection
J3
5 P3 J2 STANDBY STATUS
6 P4 J1 RADIO STATUS
7 P5 J4 IO4_A
8 P6 J3 IO3_A
9 GND
10 J25 VDD
A 50 Ohm coplanar wave
guide and a matching network
connect J29 to J3
and flashing
Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights
Reserved. Page 24 of 38
LE51-868 S RF Module User Guide
1VV0301131Rev.0 – 2014-01-16
4.5. Description of the signals
Signals Description
RESET
TXD, RXD
CTS
RTS
IO
WAKEUP
RADIO STATUS
STANDBY STATUS
External hardware reset of the radio module.
Active on low state.
Serial link signals, format NRZ/TTL:
TXD is for outgoing data. RXD is for incoming data.
The ‘1’ is represented by a high state.
Incoming signal. Indicates whether the module can send serial data to
user (Active, on low state) or not (inactive, on high state).
Outgoing signal. Indicates whether the user can transmit serial data
(active, on low state) or not (inactive, on high state).
I/O, configurable as input or as output.
Input signal which indicates to the module to wake up from low-power
mode.
Output signal which indicates the status of the radio. Set to VCC during
radio transmission or as soon as a radio frame is detected with correct
synchronization word. The signals returns to GND at the end of
transmission or as soon as the frame reception is finished.
The ‘STAND BY STATUS’ output signal is set to logical ‘1’ while the
module is operating and return to ‘0’ during stand by periods.
Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights
Reserved. Page 25 of 38
5. Process Information
5.1. Delivery
LE51-868 S modules are delivered in plastic tray packaging, each tray including 50 units. The
dimensions of the tray are the following: 329 mm x 176 mm x 5.6 mm. Each unit is placed in
a 26.6 mm x 16 mm location. An empty tray weights 45 g and a loaded tray weights around
130 g.
LE51-868 S RF Module User Guide
1VV0301131Rev.0 – 2014-01-16
Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights
Reserved. Page 26 of 38
5.2. Storage
The optimal storage environment for LE51-868 S modules should be dust free, dry and the
temperature should be included between -40°C and +85°C.
In case of a reflow soldering process, LE51-868 S radio modules must be submitted to a
drying bake at +60°C during 24 hours. The drying bake must be used prior to the reflow
soldering process in order to prevent a popcorn effect. After being submitted to the drying
bake, LE modules must be soldered on host boards within 168 hours.
Also, it must be noted that due to some components, LE51-868 S modules are ESD sensitive
device. Therefore, ESD handling precautions should be carefully observed.
5.3. Soldering pad pattern
The surface finished on the printed circuit board pads should be made of Nickel/Gold surface.
The recommended soldering pad layout on the host board for the LE51-868 S is shown in the
diagram below:
LE51-868 S RF Module User Guide
1VV0301131Rev.0 – 2014-01-16
All dimensions in mm
Neither via-holes nor wires are allowed on the PCB upper layer in area occupied by the
module.
5.4. Solder past
LE51-868 S module is designed for surface mounting using half-moon solder joints (see
diagram below). For proper module assembly, solder paste must be printed on the target
surface of the host board. The solder paste should be eutectic and made of 95.5% of SN, 4%
of Ag and 0.5% of Cu. The recommended solder paste height is 180 µm.
Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights
Reserved. Page 27 of 38
LE51-868 S RF Module User Guide
1VV0301131Rev.0 – 2014-01-16
The following diagram shows mounting characteristics for ME integration on host PCB:
5.5. Placement
The LE51-868 S module can be automatically placed on host boards by pick-and-place
machines like any integrated circuit.
5.6. Soldering Profile (RoHS Process)
It must be noted that LE51-868 S module should not be allowed to be hanging upside down
during the reflow operation. This means that the module has to be assembled on the side of
the printed circuit board that is soldered last.
The recommendation for lead-free solder reflow in IPC/JEDEC J-STD-020D Standard should
be followed.
Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights
Reserved. Page 28 of 38
LE51-868 S RF Module User Guide
1VV0301131Rev.0 – 2014-01-16
The barcode label located on the module shield is able to withstand the reflow temperature.
CAUTION - It must also be noted that if the host board is submitted to a wave soldering
after the reflow operation, a solder mask must be used in order to protect the LE51-868 S
radio module’s metal shield from being in contact with the solder wave.
Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights
Reserved. Page 29 of 38
LE51-868 S RF Module User Guide
1VV0301131Rev.0 – 2014-01-16
6. Board Mounting Recommendation
6.1. Electrical environment
The best performances of the LE51-868 S module are obtained in a “clean noise”
environment. Some basic recommendations must be followed:
...) must be placed as far as possible from the LE51-868 S module.
• Switching components circuits (especially RS-232/TTL interface circuit power
supply) must be decoupled with a 100 µF tantalum capacitor. And the decoupling
capacitor must be as close as possible to the noisy chip.
6.2. Power supply decoupling on LE51-868 S
module
The power supply of LE51-868 S module must be nearby decoupled. A LC filter must be
placed as close as possible to the radio module power supply pin, VDD.
Power Supply
Symbols Reference Value Manufacturer
L1 LQH31MN1R0K03 1µH Murata
C1 GRM31CF51A226ZE01 22µF Murata
C2 Ceramic CMS 25V 100nF Multiple
L1
C1 C2
Vdd
Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights
Reserved. Page 30 of 38
LE51-868 S RF Module User Guide
6.3. RF layout considerations
Basic recommendations must be followed to achieve a good RF layout:
• It is recommended to fill all unused PCB area around the module with ground plane
• The radio module ground pin must be connected to solid ground plane.
• If the ground plane is on the bottom side, a via (plated hole) must be used in front of
each ground pad. Especially J28 and J30 (RF Gnd) pins should be grounded by means
of several holes to be located right next to the pins, thus minimizing inductance and
preventing mismatch and losses.
1VV0301131Rev.0 – 2014-01-16
Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights
Reserved. Page 31 of 38
LE51-868 S RF Module User Guide
1VV0301131Rev.0 – 2014-01-16
6.4. Antenna connections on printed circuit
boards
Special care must be taken when connecting an antenna or a connector to the module. The RF
output impedance is 50Ω, so the strip between the pad and the antenna or connector must be
50Ω following the tables below. Ground lines should be connected to the ground plane with
as many vias as possible, but not too close to the signal line.
PCB material PCB thickness H (mm) Coplanar line W (mm) Coplanar line G (mm)
0.8 1 0.3
FR4
1.6 1 0.2
Table 1 : Values for double face PCB with ground plane around and under coplanar wave guide
(recommended)
PCB material PCB thickness H (mm) Coplanar line W (mm) Coplanar line G (mm)
0.8 1 0.22
FR4
1.6 1 0.23
Table 2 : Values for simple face PCB with ground plane around coplanar wave guide (not recommended)
Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights
Reserved. Page 32 of 38
6.5. LE51-868 S Interfacing
LE51-868 S RF Module User Guide
1VV0301131Rev.0 – 2014-01-16
Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights
Reserved. Page 33 of 38
LE51-868 S RF Module User Guide
1VV0301131Rev.0 – 2014-01-16
Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights
Reserved. Page 34 of 38
LE51-868 S RF Module User Guide
1VV0301131Rev.0 – 2014-01-16
Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights
Reserved. Page 35 of 38
LE51-868 S RF Module User Guide
7. Safety Recommendations
READ CAREFULLY
Be sure the use of this product is allowed in the country and in the environment required. The
use of this product may be dangerous and has to be avoided in the following areas:
• Where it can interfere with other electronic devices in environments such as hospitals,
airports, aircrafts, etc.
• Where there is risk of explosion such as gasoline stations, oil refineries, etc. It is
responsibility of the user to enforce the country regulation and the specific
environment regulation.
Do not disassemble the product; any mark of tampering will compromise the warranty
validity. We recommend following the instructions of the hardware user guides for a correct
wiring of the product. The product has to be supplied with a stabilized voltage source and the
wiring has to be conforming to the security and fire prevention regulations. The product has to
be handled with care, avoiding any contact with the pins because electrostatic discharges may
damage the product itself. Same cautions have to be taken for the SIM, checking carefully the
instruction for its use. Do not insert or remove the SIM when the product is in power saving
mode.
The system integrator is responsible of the functioning of the final product; therefore, care has
to be taken to the external components of the module, as well as of any project or installation
issue, because the risk of disturbing the GSM network or external devices or having impact
on the security. Should there be any doubt, please refer to the technical documentation and the
regulations in force. Every module has to be equipped with a proper antenna with specific
characteristics. The antenna has to be installed with care in order to avoid any interference
with other electronic devices and has to guarantee a minimum distance from the body (20 cm).
In case of this requirement cannot be satisfied, the system integrator has to assess the final
product against the SAR regulation.
The European Community provides some Directives for the electronic equipments
introduced on the market. All the relevant information’s are available on the European
Community website:
The text of the Directive 99/05 regarding telecommunication equipments is available,
while the applicable Directives (Low Voltage and EMC) are available at:
Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights
Reserved. Page 36 of 38
8. Glossary
LE51-868 S RF Module User Guide
1VV0301131Rev.0 – 2014-01-16
ACP
AFA
bps
BPSK
BW
dB
dBm
E2PROM
e.r.p
ETSI
GFSK
I
ISM
kB
kbps
kcps
kHz
LBT
LGA
MHz
mW
O
PER
ppm
RAM
RF
RoHS
RxD
SMD
SRD
TxD
UART
µC
Adjacent Channel Power
Adaptive Frequency Agility
Bits per second
Binary Phase Shift Keying
Bandwidth
Decibel
Power level in decibel milliwatt (10 log (P/1mW))
Electrically Erasable Programmable Read Only Memory
Effective radiated power
European Telecommunication Standard Institute
Gaussian Frequency Shift Keying
Input
Industrial, Scientific and Medical
KiloByte
Kilobits per second
Kilochips per second
Kilo Hertz
Listen Before Talk
Land Grid Array
Mega Hertz
milliwatt
Output
Packet Error Rate
Parts per million
Random Access Memory
Radio Frequency
Restriction of Hazardous Substances
Receive Data
Surface Mounted Device
Short Range Device
Transmit Data
Universal Asynchronous Receiver Transmitter
microcontroller
Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights
Reserved. Page 37 of 38
9. Document History
Revision Date Changes
0 2014/01/16 First release
LE51-868 S RF Module User Guide
1VV0301131Rev.0 – 2014-01-16
Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights
Reserved. Page 38 of 38
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.