Telit Communications S p A WE865D Hardware Manual

WE865-DUAL Hardware User Guide

1vv0300787 Rev. 1 - 03/10/08
This document is relating to the following products:
WE865-DUAL HW User Guide
1vv0300787 Rev. 1 - 03/10/08
WE865DUA000-001
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 2 of 48
WE865-DUAL HW User Guide
1vv0300787 Rev. 1 - 03/10/08

Contents

1 Overview ...........................................................................................................................6
1.1 Related documents ................................................................................................................7
2 Mechanical description....................................................................................................8
3 Pin-out.............................................................................................................................10
3.1 Pin table.................................................................................................................................10
3.2 Ball grid ......................................................................................................................
...........12
4 Electrical description .....................................................................................................13
4.1 Power supply ........................................................................................................................13
4.1.1 Unique supply voltage for WE865-DUAL and GE863-PRO3......................................................... 13
4.1.1.1Current consumption ................................................................................................................. 15
4.1.1.2Shut-down mode........................................................................................................................ 15
4.2 Power supply design guidelines.........................................................................................16
4.2.1 +5V input source............................................................................................................................ 17
4.2.2 +12V input source.......................................................................................................................... 18
4.2.3 Battery source................................................................................................................................ 20
4.3 Reset signals ........................................................................................................................20
4.3.1 Reset.............................................................................................................................................. 21
4.3.2 Manual reset .................................................................................................................................. 22
4.4 SDIO signals .........................................................................................................................23
5 Thermal design guidelines ............................................................................................24
6 PCB layout design guidelines.......................................................................................25
7 Antenna...........................................................................................................................26
7.1 Wi-Fi antenna guidelines .....................................................................................................26
7.2 Wi-Fi antenna PCB trace guidelines
...................................................................................27
7.3 Wi-Fi antenna installation guidelines
.................................................................................28
8 Integration with the GE863-PRO3..................................................................................29
8.1 Power supply ........................................................................................................................30
8.2 SDIO signals
.........................................................................................................................31
9 WE865-DUAL - Evaluation kit........................................................................................32
9.1 WE865-DUAL Interface board..............................................................................................35
9.1.1 Mechanical description .................................................................................................................. 35
9.1.2 Main components .......................................................................................................................... 36
9.1.3 Jumpers settings............................................................................................................................ 38
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 3 of 48
WE865-DUAL HW User Guide
1vv0300787 Rev. 1 - 03/10/08
9.1.4 Pin table ......................................................................................................................................... 39
10Mounting the WE865-DUAL on the application board ................................................40
10.1Stencil....................................................................................................................................40
10.2PCB pad design
10.3Solder paste
10.4Solder reflo
....................................................................................................................40
...................................................................................................................
w
.........................................................................................................................43
.......43
11Moisture sensitivity........................................................................................................45
12Conformity assessment issues ....................................................................................46
13Safety recommendations...............................................................................................47
14Document change log....................................................................................................48
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 4 of 48
WE865-DUAL HW User Guide
1vv0300787 Rev. 1 - 03/10/08
DISCLAIMER
The information contained in this document is proprietary information of Telit Communications S.p.A. including its affiliates (“TELIT”). The contents are confidential and any disclosure to persons other than the Officers, employees, agents or subcontractors of the owner or licensee of this document, without the prior written consent of Telit, is strictly prohibited.
Telit makes every effort to ensure the quality of the information it makes available. Notwithstanding the foregoing, Telit does not make any warranty as to the information contained herein, and does not accept any liability for any injury, loss or damage of any kind incurred by use of or reliance upon the information.
Telit disclaims any and all responsibility for the application of the devices characterized in this document, and notes that the application of the device must comply with the safety standards of the applicable country, and where applicable, with the relevant wiring rules.
Telit reserves the right to make modifications, additions and deletions to this document due to typographical errors, inaccurate information, or improvements to programs and/or equipment at any time without a notice. Such changes will, nevertheless be incorporated into new editions of this document.
All rights reserved.
© 2008 Telit Communications S.p.A.
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 5 of 48

1 Overview

WE865-DUAL HW User Guide
1vv0300787 Rev. 1 - 03/10/08
This document is a user guide for developing a wireless application which integrates the Telit WE865-
DUAL with the GE863-PRO
3
GSM/GPRS module creating a unique solution for a short and long range. This document cannot embrace the whole hardware solutions and products that may be designed. The information given is a guide line and a starting point for properly developing products with the Telit WE865-DUAL module. For further hardware details please refer to the Telit “WE865-DUAL Product Description” document.
NOTICE
(EN) The integration of the Wi-Fi WE865-DUAL module within user application shall be done according to the design rules described in this manual.
(IT) L’integrazione del modulo Wi-Fi WE865-DUAL all’interno dell’applicazione dell’utente dovrà rispettare le indicazioni progettuali descritte in questo manuale.
(DE) Die integration des Wi-Fi WE865-DUAL Moduls in ein Gerät muß gemäß der in diesem Dokument beschriebenen Kunstruktionsregeln erfolgen.
(SL) Integracija Wi-Fi WE865-DUAL modula v uporabniški aplikaciji bo morala upoštevati projektna navodila, opisana v tem piročniku.
(SP) La utilización del modulo Wi-Fi WE865-DUAL debe ser conforme a los usos para los cuales ha sido deseñado descritos en este manual del usuario.
(FR) L’intégration du module Wi-Fi WE865-DUAL dans l’application de l’utilisateur sera faite selon les règles de conception décri tes dans ce manuel.
ה םדומ לש היצרגטניאה ךילהתהב הז ךמסמב תוטרופמה תויחנהה תא םשייל שקבתמ רוטרגטניאהWi-Fi WE865-DUAL
רצומה םע
The information presented in this document is believed to be accurate and reliable. However, no responsibility is Assumed by Telit Communications S.p.A. for its use, nor any infringement of patents or other rights of third parties which may result from its use. No license is granted by implication or otherwise under any patent rights of Telit Communications S.p.A. other than for circuitry embodied in Telit products. This document is subject to change without notice.
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 6 of 48
WE865-DUAL HW User Guide
1vv0300787 Rev. 1 - 03/10/08

1.1 Related documents

The following documents are related to this user guide:
[1] Telit WE865-DUAL Product Description 80312ST10046A [2] Telit WE865-DUAL Software User Guide 1vv0300788 [3] Telit GE863-PRO³ Hardware User Guide 1vv0300773a [4] Telit GE863-PRO³ Software User Guide 1vv0300788 [5] Telit GE863PRO [6] Telit GE863PRO [7] Telit GE863PRO3Linux Development Environment User Guide1vv0300780
All documentation can be downloaded from Telit’s official web site www.telit.com indicated.
3
EVK User Guide 1vv0300776
3
Linux SW User Guide 1vv0300781
if not otherwise
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 7 of 48

2 Mechanical description

The Telit WE865-DUAL module overall dimensions are:
Length: 22.15 mm (max)
Width: 22.15 mm (max)
Thickness: 3.48 mm (max)
Weight 3.5 g
WE865-DUAL HW User Guide
1vv0300787 Rev. 1 - 03/10/08
Figure 1
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 8 of 48
WE865-DUAL HW User Guide
1vv0300787 Rev. 1 - 03/10/08
Figure 2 (Bottom side)
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 9 of 48
WE865-DUAL HW User Guide
1vv0300787 Rev. 1 - 03/10/08

3 Pin-out

3.1 Pin table

Ball Signal I/O Function
SDIO
A1 SDIO[0]
B2 SDIO[1]
A2 SDIO[2]
B3 SDIO[3]
A3 SDIO_CLK
A4 SDIO_CMD
C3 TEST_1 O Test line n. 1 - TEST
C4 TEST_2 I Test line n. 2 - TEST
C5 TEST_3 I Test line n. 3 - TEST
D5 TEST_4 I Test line n. 4 - TEST
B1 EN_A* I Enable/shut-down 10KOhm pull-up control
C1 MR_RESET* I Manual reset
D1 EN_B* I Enable/shut-down 10KOhm pull-up control
D2 RESET I Reset for host processor
H5 RF_ANT RF RF output - antenna
E1 VDD PWR Power input pin - power supply
E2 VDD PWR Power input pin - power supply
F1 VCC_A PWR Power input pin - power supply
F2 VCC_A PWR
F3 VCC_A PWR
A5 N.C.
A6 N.C.
I/O I/O SDIO DATA[1]
I/O I/O SDIO DATA[3]
I/O SDIO CLOCK
I/O
SDIO DATA[0] (or SPI MISO) 10KOhm pull-up SDIO (or SPI)
(or SPI INTERRUPT)
SDIO DATA[2] 10KOhm pull-up SDIO
(or SPI CHIP SELECT)
(or SPI CLOCK)
SDIO CMD (or SPI MOSI ) 10KOhm pull-up SDIO (or SPI)
Testing and Certification
Miscellaneous Functions
Power Supply
Power input pin
Power input pin
RESERVED1
Internal PULL
UP/DOWN
10KOhm pull-up SDIO (or SPI)
10KOhm pull-up SDIO (or SPI)
- SDIO (or SPI)
100KOhm pull-
up control
47KOhm pull-
down control
- power supply
- power supply
Type
1
All the reserved pins must be kept not connected (N.C.)
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 10 of 48
WE865-DUAL HW User Guide
1vv0300787 Rev. 1 - 03/10/08
Ball Signal I/O Function
A7 N.C.
A8 N.C.
B4 N.C.
B5 N.C.
B6 N.C.
B7 N.C.
B8 N.C.
C5 N.C.
C6 N.C.
C8 N.C.
D3 N.C.
D4 N.C.
D6 N.C.
D7 N.C.
D8 N.C.
E3 N.C.
E4 N.C.
E6 N.C.
E8 N.C.
F4 N.C.
F5 N.C.
F6 N.C.
F7 N.C.
F8 N.C.
G2 N.C.
G6 N.C.
G7 N.C.
G8 N.C.
H1 N.C.
H2 N.C.
H4 N.C. H7 N.C.
H8 N.C.
Table 1
Internal PULL
UP/DOWN
Type
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 11 of 48
WE865-DUAL HW User Guide
1vv0300787 Rev. 1 - 03/10/08

3.2 Ball grid

A B C D E F G H
1 SDIO[0] EN_A* MR_RESET* EN_B* VDD VCC_A GND NC
2 SDIO[2] SDIO[1] GND RESET VDD VCC_A NC NC
3 SDIO_CLK SDIO[3] TEST_1 NC NC VCC_A GND GND
4 SDIO_CMD NC TEST_2 NC NC NC GND NC
5 NC NC TEST_3 TEST_4 GND NC GND RF_ANT
6 NC NC NC NC NC NC NC GND
7 NC NC GND NC GND NC NC NC
8 NC NC NC NC NC NC NC NC
Table 2
NOTE: The drawing above is a top view.
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 12 of 48
WE865-DUAL HW User Guide
1vv0300787 Rev. 1 - 03/10/08

4 Electrical description

The power supply circuitry and board layout are a very important part in the full product design and they strongly reflect on the product overall performances, hence read carefully the requirements and the guidelines that will follow for a proper design.

4.1 Power supply

Powering of the module:
wide range voltage operation from 3.4V up to 4.2V (typical voltage 3.8V) the same as for GE863-PRO
The above voltage range is chosen in order to use the same voltage range for the Wi-Fi module WE865-DUAL and the GE863-PRO

4.1.1 Unique supply voltage for WE865-DUAL and GE863-PRO3

In order to get the suitable voltage range valid for both WE865-DUAL and GE863-PRO need to be connected as described below.
3
.
3
.
signal ball 3.8V (typ)
F1
VCC_A
VDD
F2
F3 E1 E2
Table 3
3
certain balls
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 13 of 48
)
)
)
)
)
WE865-DUAL HW User Guide
1vv0300787 Rev. 1 - 03/10/08
3.8 V (typ)
WE865-DUAL
VCC_A (F1
VCC_A (F2
VCC_A (F3
VDD (E1
VDD (E2
Figure 3
The table below shows the operating and absolute voltage ranges.
VOLTAGE RANGES @ 25 °C
Min [V] Typ [V] Max [V]
Operating range 3.4 3.8 4.2
Table 4
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 14 of 48
WE865-DUAL HW User Guide
1vv0300787 Rev. 1 - 03/10/08
4.1.1.1 Current consumption
CURRENT CONSUMPTION @ 3.8V at 25 °C
Operating mode Typ Unit
Continuous Receive 100 mA Continuous Transmit (maximum output power) 180 mA Stand-by (receive beacons every 100 ms) 5 mA Deep Sleep 3 mA Shut-down mode <1 mA
Table 5
NOTE: continuous receive and transmit mode measures were taken at channel 6.
4.1.1.2 Shut-down mode
In order to minimize the current consumption it is possible to completely shut-down the WE865-DUAL. That is achieved by acting on the relevant signal outside the module, which directly acts on the power device enable/Shut-down signals. The shut-down is achievable by driving low both the EN_B* (ball D1) and EN_A* (ball B1) signals, to be connected together. As EN_B* (ball D1) and EN_A* (ball B1) are internally connected to pull-up, do not drive these signals during normal operation.
LOGIC CONFIGURATION
signal ball Shut-down mode Operating mode
EN_A* B1 to be driven low internally pulled-up 2 EN_B* D1 to be driven low internally pulled-up 1
Table 6
2
If the shut-down mode is not used, no external connection is needed.
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 15 of 48
VOLTAGE LEVELS @ 25 °C
SIGNAL
Min [V] Max [V]
VIL
EN_A*, EN_B* 0 0.20
Table 7
EN_A*
WE865-DUAL HW User Guide
1vv0300787 Rev. 1 - 03/10/08
WE865-DUAL
EN_B*
Figure 4

4.2 Power supply design guidelines

The power supply circuitry is a very important part in the full product design and it strongly affects the product overall performances, hence read carefully the requirements and the guidelines that will follow for a proper design. The table below shows the WE865-DUAL operating voltage range:
VOLTAGE RANGE
Nominal Supply Voltage 3.8V
Minimum Supply Voltage 3.4V
Max Supply Voltage 4.2V
Table 8
The electrical design of the power supply strongly depends on the power source the current is drained from. Please refer to electrical design guidelines in the GE863-PRO information.
3
Hardware User Guide for further
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 16 of 48
WE865-DUAL HW User Guide
1vv0300787 Rev. 1 - 03/10/08

4.2.1 +5V input source

A linear regulator can be used to generate the 3.8V output voltage. When using a linear regulator, a proper heat sink shall be provided in order to dissipate the generated power. A protection diode should be inserted close to the power input, in order to save the WE865-DUAL from power polarity inversion. This can be the same diode as for spike protection.
The figure below shows a possible solution for the switching power supply. It must be taken into account that the power supply performance strongly depends on the layout design.
Figure 5
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 17 of 48
WE865-DUAL HW User Guide
1vv0300787 Rev. 1 - 03/10/08

4.2.2 +12V input source

Due to the big difference between the input source and the desired output voltage, a linear voltage regulator is not suited and not recommended. A switching power supply will be preferable because of its better efficiency especially in presence of peak current load. When using a switching regulator, 500 kHz switching frequency (or more) is preferable because of its smaller inductor size and its faster transient response. This allows the regulator to respond quickly to any current peak absorption. A protection diode should be inserted close to the power input, in order to save the WE865-DUAL from power polarity inversion. This can be the same diode as for spike protection.
The figure below shows a possible solution for the switching power supply. It must be taken into consideration that the switching power supply performances strongly depend on the layout design.
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 18 of 48
WE865-DUAL HW User Guide
1vv0300787 Rev. 1 - 03/10/08
Figure 6
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 19 of 48
WE865-DUAL HW User Guide
1vv0300787 Rev. 1 - 03/10/08

4.2.3 Battery source

The desired nominal output for the power supply is 3.8V and the maximum voltage allowed is 4.2V, thus a single 3.7V Li-Ion cell battery type is suited for supplying the power to the WE865-DUAL module.
Please refer to GE863-PRO and battery usage.
A protection diode should be inserted close to the power input, in order to save the WE865-DUAL from power polarity inversion. Otherwise the battery connector should be done in a way to avoid polarity inversions when connecting the battery. When integrating the GE863-PRO take into account that battery charger control circuitry is embedded inside the GE863-PRO refer to GE863-PRO
3
Hardware User Guide for more details) and can be used with Li-ION batteries only. Using other type of batteries, an external charger will be needed. The battery capacity should be suitable chosen dependently on the customer’s application current consumption and the battery life requirements. When integrating the GE863-PRO DUAL modules together in the user application, the battery capacity must be at least 800mAh in order to withstand any current peak (please refer to GE863-PRO
3
electrical design guidelines for further information regarding type
3
with the WE865-DUAL modules together in the user application,
3
with the WE865-
3
Hardware User Guide for more details).
3
(please

4.3 Reset signals

The WE865-DUAL has a power-on-reset (POR) circuit inside, so no specific reset is required in the initialization phase. Two signals are available to reset the module:
an active high host reset (RESET)
an active low manual reset (MR_RESET*)
In addition to the active high RESET signal issued by the host system (GE863-PRO can be integrated in the customer application.
Even if it is not mandatory to drive the available reset lines in the module, it is recommended to employ those signals to prevent critical situations.
When resetting during normal operation, after the release of the reset the module is unconditionally shut down, without doing any detach operation from the network where it is associated.
3
), a reset button
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 20 of 48
WE865-DUAL HW User Guide
1vv0300787 Rev. 1 - 03/10/08

4.3.1 Reset

An active high host reset (RESET, ball D2), allowing the WE865-DUAL to be reset by an external device (host). This pin is internally pulled-down, do not drive the signal during normal operation.
The signal must be asserted for a period greater than 1ms.
VOLTAGE LEVELS @ 25 °C
Min [V] Max [V] Remark
VIH 2,0 3,0 -
Table 9
WE865-DUAL
RESET
Figure 7
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 21 of 48
WE865-DUAL HW User Guide
1vv0300787 Rev. 1 - 03/10/08

4.3.2 Manual reset

An active low manual reset (MR_RESET*, ball C1), see the table below for the allowed voltage levels. As the pin is internally pulled-up, do not drive the signal during normal operation.
The signal must be asserted for a period greater than 1ms.
VOLTAGE LEVELS @ 25 °C
Min [V] Max [V] Remark
VIL -0,3 0,825
Table 10
WE865-DUAL
MR_RESET*
Figure 8
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 22 of 48
WE865-DUAL HW User Guide
1vv0300787 Rev. 1 - 03/10/08

4.4 SDIO signals

A 4-data bit SDIO interface is available on the WE865-DUAL that must be connected to the host processor (Telit GE863-PRO WE865-DUAL SDIO voltage levels are fully compatible with the GE863-PRO 47 Ohm series resistor on each SDIO line and 12pF capacitor on clock line must be inserted in order to avoid noise (see Electrical design guidelines chapter). Refer to §8.2.
Voltage levels for all the
3
).
SDIO pins are reported in the table:
3
I/O voltage levels.
VOLTAGE LEVELS @ 25 °C
Min [V] Max [V] Remark
VIL -0,3 0,825
VIH 2,0625 3,6 VOL 0 0,125 I = 4mA VOH 2,475 3,3 I = 4mA
Table 11
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 23 of 48
WE865-DUAL HW User Guide
1vv0300787 Rev. 1 - 03/10/08

5 Thermal design guidelines

The thermal design for the power supply heat sink should be done taking into account the current consumption involved in the appropriate power supply configuration. Please refer to §4.1.1.1 for detailed info
rmation on the current consumption.
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 24 of 48
WE865-DUAL HW User Guide
1vv0300787 Rev. 1 - 03/10/08

6 PCB layout design guidelines

In case of implementing the input power supply circuitry as described in the previous §4.2.2, the PCB traces connecting the switching out possible. It is recommended to place the inductor and the diode very close to the power switching IC. This is done in order to reduce the radiated field (noise) of the switching frequency (100-500 kHz usually).
The use of a good common ground plane is generally suggested. The placement of the power supply on the board should be done in such a way to guarantee that the high current return paths in the ground plane are not overlapped to any noise sensitive lines. The power supply input cables should be kept separate from noise sensitive lines.
put to the inductor and the switching diode must be as short as
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 25 of 48
WE865-DUAL HW User Guide
1vv0300787 Rev. 1 - 03/10/08

7 Antenna

The antenna connection and board layout design are the most important part in the full product design and they strongly reflect on the product overall performances, hence read carefully and follow the requirements and the guidelines for a proper design.

7.1 Wi-Fi antenna guidelines

General guidelines for an antenna and antenna line on PCB for a Telit WE865-DUAL device
ANTENNA REQUIREMENTS
Frequency range [MHz] 2400-2500 Gain [dBi] 2 Impedance [Ohm] 50 Maximum Input Power [mW] >100 VSWR recommended 2
Table 12
Frequency range indicated in order to support 14 Wi-Fi channels. Smaller ranges are allowed or requested for application over 11 or 13 channels.
Please refer to IEEE specifications and to the proper regulatory body directives about 802.11 channels and antenna specifications in different countries.
When using the Telit WE865-DUAL, since there's no antenna connector on the module, the antenna must be connected to the WE865-DUAL through the PCB with the antenna pad.
Please consider that antenna design and choice is dependent on the specific application.
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 26 of 48
This transmission line shall fulfill the following requirements:
ANTENNA LINE ON PCB REQUIREMENTS
Impedance [Ohm] 50 Maximum Attenuation [dB] 0.3
Coupling with other signals is not allowed
Table 13
WE865-DUAL HW User Guide
1vv0300787 Rev. 1 - 03/10/08

7.2 Wi-Fi antenna PCB trace guidelines

Ensure that the antenna line impedance is 50 ohm.
Keep the antenna line on the PCB as short as possible in order to limit losses.
Antenna line must have uniform characteristics, constant cross section, avoid meanders
and abrupt curves.
Keep, if possible, one layer of the PCB used only for the Ground plane.
Surround (on the sides, over and under) the antenna line on PCB with Ground, avoid
having other signal tracks facing directly the antenna line track.
The ground around the antenna line on PCB has to be strictly connected to the Ground Plane by placing vias once per 2mm at least.
Place EM noisy devices as far as possible from WE865-DUAL antenna line.
Keep the antenna line far away from the WE865-DUAL power supply lines.
If you have EM noisy devices around the PCB hosting the WE865-DUAL, such as fast
switching ICs, take care of the shielding of the antenna line by burying it inside the layers of PCB and surround it with Ground planes, or shield it with a metal frame cover.
If you don't have EM noisy devices around the PCB of WE865-DUAL, by using a strip-line on the superficial copper layer for the antenna line, the line attenuation will be lower than a buried one.
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 27 of 48
WE865-DUAL HW User Guide
1vv0300787 Rev. 1 - 03/10/08

7.3 Wi-Fi antenna installation guidelines

Install the antenna in a place covered by the Wi-Fi signal.
The antenna must be installed to provide a separation distance of at least 20 cm
from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.
Antenna shall not be installed inside metal cases.
Antenna shall be installed also according Antenna manufacturer instructions.
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 28 of 48
WE865-DUAL HW User Guide
1vv0300787 Rev. 1 - 03/10/08

8 Integration with the GE863-PRO3

NOTE: It is mandatory to leave available the TEST lines in the customer design:
TEST_1
TEST_2
TEST_3
TEST_4
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 29 of 48
Figure 9 (Block diagram)
WE865-DUAL HW User Guide
1vv0300787 Rev. 1 - 03/10/08

8.1 Power supply

When integrating the WE865-DUAL with the Telit GE863-PRO chapters a 3.8V (typ) voltage must be provided to the WE865-DUAL. The WE865-DUAL power enable signals (EN_A* and EN_B*) must be connected together and be driven by the GE863-PRO In the GE863-PRO
3
3
GPIO PC29 (ball F5) through a N-channel MOSFET.
the power supply inputs of the GSM engine and the ARM processor part have been kept separate, VBATT is the input for the GSM part, VBATT2 is the input for ARM. It is possible to connect together the two power inputs since they have compatible ranges, but if it is desired the two power supplies can be kept separate. If keeping separated VBATT and VBATT2 is the chosen solution, the WE865-DUAL 3.8V power balls (VCC_A) should be connected to the same voltage source feeding VBATT2.
3V8 (typ) 3V8 (typ)
3
module, as described in previous
3V8 (typ)
3V8 (typ)
VBATT VBATT2
VCC_A
EN_A*
VDD
WE865-DUAL
PC29
EN_B*
GE863-PRO3
GND GND
Figure 10
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 30 of 48
WE865-DUAL HW User Guide
1vv0300787 Rev. 1 - 03/10/08

8.2 SDIO signals

A 4-data bit SDIO interface is available on the WE865-DUAL that must be connected to the host processor (Telit GE863-PRO The WE865-DUAL SDIO voltage levels are fully compatible with the GE863-PRO 47 Ohm series resistor on each SDIO line and 12pF capacitor on clock line must be inserted in order to avoid noise (see Electrical design guidelines chapter). Refer to block diagram in Figure 7.
3
).
3
I/O voltage levels.
Figure 11
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 31 of 48
WE865-DUAL HW User Guide
1vv0300787 Rev. 1 - 03/10/08

9 WE865-DUAL - Evaluation kit

The WE865-DUAL can be provided with an evaluation/testing kit. The kit consists of:
EVK-PRO (EVK-PRO
WE865-DUAL interface board
In such a case, the WE865-DUAL module is directly soldered on its interface board. The figure below shows how the boards must be assembled in order to allow the system working.
3
evaluation kit for GE863-PRO3 module
3
main board + GE863-PRO3 interface board)
WE865-DUAL interface board
GE863-PRO3 interface board
EVK-PRO
3
main board
Figure 12
All the boards are connected each other via 40-pins connectors. The core of the evaluation system is the EVK-PRO functional blocks depending on the implemented function. Refer to the “EVK-PRO additional information on the EVK-PRO
3
description and usage.
3
EVALUATION KIT, which can be split into several
3
User Guide” for
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 32 of 48
GE863-PRO
WE865-DUAL HW User Guide
1vv0300787 Rev. 1 - 03/10/08
3
WE865-DUAL interface board
WE865-DUAL
EVK-PRO
3
Figure 13
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 33 of 48
WE865-DUAL HW User Guide
1vv0300787 Rev. 1 - 03/10/08
EVK-PRO3
WE865-DUAL interface board
WE865-DUAL
GE863-PRO
3
Figure 14
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 34 of 48

9.1 WE865-DUAL Interface board

9.1.1 Mechanical description

WE865-DUAL HW User Guide
1vv0300787 Rev. 1 - 03/10/08
Figure 15
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 35 of 48

9.1.2 Main components

Main components TOP side list:
WE865-DUAL module PL101: 2 pin jumper PL102: 2 pin jumper SW101: Reset button – Push to drive MR_RESET* low) SO104: RF connector (alternative to AT101) PL103: 5 pin header - SPI for test
WE865-DUAL HW User Guide
1vv0300787 Rev. 1 - 03/10/08
Figure 16
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 36 of 48
Main components BOTTOM side list:
SO101: Interface connector SO102: Interface connector SO103: Interface connector
WE865-DUAL HW User Guide
1vv0300787 Rev. 1 - 03/10/08
Figure 17
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 37 of 48
WE865-DUAL HW User Guide
1vv0300787 Rev. 1 - 03/10/08

9.1.3 Jumpers settings

The figure below shows the PL101 and PL102 jumpers on the TOP side in the interface board
Figure 18
PL101 - Short the jumper to drive EN_A* low PL102 - Short the jumper to drive EN_B* low
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 38 of 48

9.1.4 Pin table

Pin n. Signal name Signal name Signal name Signal name
1 RESERVED RESERVED RESERVED TEST_1 2 RESERVED RESERVED RESERVED TEST_2 3 RESERVED RESERVED RESERVED TEST_3 4 RESERVED RESERVED RESERVED TEST_4 5 RESERVED RESERVED RESERVED GND 6 RESERVED RESERVED RESERVED ­7 SDIO[0] RESERVED RESERVED ­8 SDIO_CMD RESERVED RESERVED -
9 SDIO_CLK RESERVED RESERVED ­10 SDIO[1] RESERVED RESERVED ­11 SDIO[2] RESERVED RESERVED ­12 SDIO[3] RESERVED RESERVED ­13 RESERVED RESERVED RESERVED ­14 RESERVED RESERVED RESERVED ­15 RESERVED RESERVED RESERVED ­16 RESERVED RESERVED RESERVED ­17 RESERVED RESERVED RESERVED ­18 RESERVED RESERVED RESERVED ­19 RESERVED RESERVED RESERVED ­20 RESERVED RESERVED RESERVED ­21 RESERVED RESERVED RESERVED ­22 RESERVED RESERVED RESERVED ­23 RESERVED RESERVED RESERVED ­24 RESERVED RESERVED RESERVED ­25 RESERVED RESERVED RESERVED ­26 RESERVED RESERVED RESERVED ­27 RESERVED RESERVED RESERVED ­28 RESERVED RESERVED RESERVED ­29 RESERVED RESERVED RESET ­30 RESERVED RESERVED RESERVED ­31 RESERVED RESERVED RESERVED ­32 RESERVED RESERVED RESERVED ­33 RESERVED RESERVED RESERVED ­34 RESERVED RESERVED RESERVED ­35 RESERVED RESERVED RESERVED ­36 VBATT RESERVED RESERVED ­37 RESERVED RESERVED GND ­38 RESERVED RESERVED RESERVED ­39 GND GND GND ­40 GND GND RESERVED -
WE865-DUAL HW User Guide
1vv0300787 Rev. 1 - 03/10/08
SO101 SO102 SO103 PL103
Table 14
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 39 of 48
WE865-DUAL HW User Guide
1vv0300787 Rev. 1 - 03/10/08
10 Mounting the WE865-DUAL on the
application board
The Telit WE865-DUAL module has been designed in order to be compliant with a standard lead-free SMT process.

10.1 Stencil

Stencil’s apertures layout can be the same of the recommended footprint (1:1), we suggest a thickness of stencil foil 120μm.

10.2 PCB pad design

"Non solder mask defined” (NSMD) type is recommended for the solder pads on the PCB.
Figure 19
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 40 of 48
WE865-DUAL HW User Guide
1vv0300787 Rev. 1 - 03/10/08
Figure 20
Recommendations for PCB pad dimensions
Dimension Value [mm]
Ball pitch 2 Solder resist opening diameter A 1,150 Metal PAD diameter B 1 +/- 0,05
Table 15
Placement of microvias not covered by solder resist is not recommended inside the “Solder resist Opening”,unless the microvia carry the same signal of the pad itself.
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 41 of 48
WE865-DUAL HW User Guide
1vv0300787 Rev. 1 - 03/10/08
Figure 21
Holes in pad are allowed only for blind holes and not for through holes. Recommendations for PCB pad surfaces:
Finish Layer tickness [um] Properties
Electro-less Ni /
Immersion Au
3-7 /
0,05-0,15
Table 16
good solder ability protection,
high shear force values
The PCB must be able to resist the higher temperatures, which are occurring at the lead-free process. This issue should be discussed with the PCB-supplier. Generally, the wet-ability of tin-lead solder paste on the described surface plating is better compared to lead-free solder paste.
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 42 of 48

10.3 Solder paste

WE865-DUAL HW User Guide
1vv0300787 Rev. 1 - 03/10/08
Lead free
Solder paste
Table 17

10.4 Solder reflow

The following is the recommended solder reflow profile
Sn / Ag / Cu
Figure 22
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 43 of 48
WE865-DUAL HW User Guide
1vv0300787 Rev. 1 - 03/10/08
Profile Feature
Pb-Free
Assembly
3 °C / second
Average ramp-up rate (TL to TP) Preheat:
- Temperature Min (Tsmin)
- Temperature Max (Tsmax)
- Time (min to max) (ts) Tsmax to TL:
- Ramp-up rate Time maintaned above:
- Temperature (TL)
- Time (tL)
max 150 °C
200 °C 60-180 seconds
3 °C / second max
217 °C 60-150
seconds Peak Temperature (Tp): 245 + 0/-5 °C Time within 5 °C of actual Peak
Temperature (tp)
10-30 seconds
6 °C/second Ramp-down rate
max Time 25 °C to Peak Temperature 8 minutes max
Table 18
NOTE: All temperatures refer to topside of the package, measured on the package body surface.
IMPORTANT: WE865-DUAL module can accept only one reflow process
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 44 of 48
WE865-DUAL HW User Guide
1vv0300787 Rev. 1 - 03/10/08

11 Moisture sensitivity

The level of moisture sensibility of Telit WE865-DUAL modules is “3”, according with standard IPC/JEDEC J-STD-020, take care of all the relative requirements for using this kind of components. Moreover, the customer has to take care of the following conditions:
The shelf life of WE865 inside of the dry bag shall be 12 month from the bag seal date, when stored in a non-condensing atmospheric environment of <40°C / 90% RH
Environmental condition during the production: ≤ 30°C / 60% RH according to IPC/JEDEC J- STD-033A paragraph 5
The maximum time between the opening of the sealed bag and the reflow process shall be 168
Hours if the condition b) “IPC/JEDEC J-STD-033A paragraph 5.2” is respected
A baking is required if conditions b) or c) are not respected
A baking is required if the humidity indicator inside the bag indicates 10% RH or more
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 45 of 48
WE865-DUAL HW User Guide
1vv0300787 Rev. 1 - 03/10/08

12 Conformity assessment issues

Assessment of the final product must be made against the Essential requirements of the R&TTE Directive Articles 3.1(a) and (b), safety and EMC respectively, and any relevant Article 3.3 requirements.
The WE865-DUAL module is conform with the following European Union Directives:
R&TTE Directive 1999/5/EC (Radio Equipment & Telecommunications Terminal Equipments)
Low Voltage Directive 73/23/EEC and product safety
Directive 89/336/EEC for conformity for EMC
In order to satisfy the essential requisite of the R&TTE 99/5/EC directive, the WE865-DUAL module is compliant with the following standards:
Use of RF Spectrum. Standard: EN 300 328 v1.7.1 (2006-10)
EMC (Electromagnetic Compatibility). Standards: EN 301 489-1 and EN 301 489-17
LVD (Low Voltage Directive) Standards: EN 60 950
The WE865-DUAL module is conform with the following US Directives:
Use of RF Spectrum. Standards: FCC 47 Part 15
EMC (Electromagnetic Compatibility). Standards: FCC 47 Part 15
To meet the FCC's RF exposure rules and regulations:
- The system antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all the persons and must not be co-located or operating in conjunction with any other antenna or transmitter.
- The system antenna(s) used for this module must not exceed 2 dBi for all operating configurations.
- Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.
Manufacturers of mobile, fixed or portable devices incorporating this module are advised to clarify any regulatory questions and to have their complete product tested and approved for FCC compliance.
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 46 of 48
WE865-DUAL HW User Guide
1vv0300787 Rev. 1 - 03/10/08

13 Safety recommendations

READ CAREFULLY
Be sure the use of this product is allowed in the country and in the environment required. The use of this product may be dangerous and has to be avoided in the following areas:
Where it can interfere with other electronic devices in environments such as hospitals, airports,
aircrafts, etc
Where there is risk of explosion such as gasoline stations, oil refineries, etc
It is responsibility of the user to enforce the country regulation and the specific environment regulation.
Do not disassemble the product; any mark of tampering will compromise the warranty validity.
We recommend following the instructions of the hardware user guides for a correct wiring of the product. The product has to be supplied with a stabilized voltage source and the wiring has to be conforming to the security and fire prevention regulations.
The product has to be handled with care, avoiding any contact with the pins because electrostatic discharges may damage the product itself.
The system integrator is responsible of the functioning of the final product; therefore, care has to be taken to the external components of the module, as well as of any project or installation issue, because the risk of disturbing the external networks or devices or having impact on the security. Should there be any doubt, please refer to the technical documentation and the regulations in force.
Every module has to be equipped with a proper antenna with specific characteristics. The antenna has to be installed with care in order to avoid any interference with other electronic devices and has to guarantee a minimum distance from the body (20 cm). In case of this requirement cannot be satisfied, the system integrator has to assess the final product against the SAR regulation EN 50360.
The European Community provides some Directives for the electronic equipments introduced on the market. All the relevant information’s are available on the European Community website:
http://europa.eu.int/comm/enterprise/rtte/dir99-5.htm
The text of the Directive 99/05 regarding telecommunication equipments is available, while the applicable Directives (Low Voltage and EMC) are available at:
http://europa.eu.int/comm/enterprise/electr_equipment/index_en.htm
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 47 of 48

14 Document change log

RReevviissiioonn DDaattee
ISSUE#0 20/08/08 Preliminary Release ISSUE#1 03/10/08 Updated mechanical dimensions
CChhaannggeess
Updated pin-out and ball grid Updated power configuration section Added current consumption Updated reset section Updated antenna section Updated integration section with GE863-PRO3 Updated evaluation kit section Added conformity assessment issues section Added safety recommendations section
WE865-DUAL HW User Guide
1vv0300787 Rev. 1 - 03/10/08
Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 48 of 48
Loading...