Channel 1
Channel 2
Channel 3
Channel 4
Channel 5
Channel 6
INSTALLATION & OPERATION INSTRUCTIONS
IC-6SX Source Assignment Panel
INSTALLATION
INPUTS OUTPUTS
123456 123456789101112
INPUTS
TELEX COMMUNICATIONS, INC. MADE IN USA
IC-6SX SOURCE ASSIGN PANEL
Input channels.
Link Cable
Wiring
1
2
3
4
5
6
7
8
9
10
11
15 pin Male D-Sub
Use shielded cable for
connections greater
than two feet.
12
13
14
15 15
Note: An optional pre-wired, unshielded cable is available.
Use p/n: 9002-7690-000 when ordering.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Expansion Connector (15 pin D-Sub Female)
Pinout
noitpircseDsrebmuNniP
oiduA1lennahC9,1
oiduA2lennahC01,2
oiduA3lennahC11,3
Output channels.
Linking Two Units Together
Inputs 1-6
INPUTS
INPUTS
TELEXCOMMUNICATIONS, INC. MADEIN USA
INPUTS
INPUTS
15 pin Male D-Sub
1122334455661122334455667788991010111112
TELEXCOMMUNICATIONS, INC. MADEIN USA
Inputs not used.
Input (3 pin XLR Female) &
Output (3 pin XLR Male)
Connector
Outputs 1-12
OUTPUTS
IC-6SXSOURCE ASSIGN PANEL
OUTPUTS
IC-6SXSOURCE ASSIGN PANEL
Outputs 13-24
noitpircseD)s(rebmuNniP
oiduAdecnalaB3,2
EXPANSION
Links two IC-6SX
units together.
12
EXPANSION
EXPANSION
Expansion Cable
)DNG(nommoClangiS1
oiduA4lennahC21,4
oiduA5lennahC31,5
oiduA6lennahC41,6
)DNG(nommoClangiS51,8,7
OPERATION
®
1 2 3 4 5 6 7 8 9 10 11 12
Set switches to assign
input channels to output
channels.
9350-7690-000 Rev. A, 3/2001
OUTPUTS
IC-6SX
Source Assign Panel
111111111111
Channel 1
Channel 2
222222222222
Channel 3
333333333333
Channel 4
444444444444
Channel 5
555555555555
Channel 6
666666666666

SPECIFICATIONS
Dimensions: H: 1.75” (44.5 mm) W: 19.0” (482 mm) D: 3.85” (98 mm)
Weight: 3.44 lbs (1.55 kg)
Power: N/A
Matrix Type: Passive, Mechanically Switched
Inputs: 6, Balanced, Female XLR type
Outputs: 12, Balanced, Male XLR type
TRADEMARKS
Audiocom® is a registered trademark of Telex Communications. Names
of other products mentioned herein are used for identification
purposes only and may be trademarks and/or registered trademarks of
their respective companies.
WARRANTY INFORMATION
Products are warranted by Telex Communications, Inc. to be free from
defects in materials and workmanship for a period of one year from
the date of sale.
The sole obligation of Telex during the warranty period is to provide,
without charge, parts and labor necessary to remedy covered defects
appearing in products returned prepaid to Telex. This warranty does
not cover any defect, malfunction or failure caused beyond the control
of Telex, including unreasonable or negligent operation, abuse,
accident, failure to follow instructions in the manual, defective or
improper associated equipment, attempts at modification and repair
not authorized by Telex, and shipping damage. Products with their
serial numbers removed or effaced are not covered by this warranty.
To obtain warranty service, follow the procedures entitled “Procedure
for Returns” and “ Shipping to Manufacturer for Repair or Adjustment”.
This warranty is the sole and exclusive express warranty given with
respect to Audiocom products. It is the responsibility of the user to
determine before purchase that this product is suitable for the user’s
intended purpose.
ANY AND ALL IMPLIED WARRANTIES, INCLUDING THE IMPLIED
WARRANTY OF MERCHANTABILITY ARE LIMITED TO THE
DURATION OF THIS EXPRESS LIMITED WARRANTY.
NEITHER TELEX NOR THE DEALER WHO SELLS TELEX PRODUCTS IS LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY KIND.
CUSTOMER SUPPORT
Technical questions should be directed to:
RETURN SHIPPING INSTRUCTIONS
Procedure for Returns
If a return is necessary, contact the dealer where this unit was
purchased.
If a return through the dealer is not possible, obtain a RETURN
AUTHORIZATION from:
Customer Service Department
Telex Communications, Inc.
Telephone: 1-800-392-3497 or (952) 884-4051
Fax: 1-800-323-0498 or (952) 884-0043
DO NOT RETURN ANY EQUIPMENT DIRECTLY TO THE FACTORY
WITHOUT FIRST OBTAINING A RETURN AUTHORIZATION.
Be prepared to provide the company name, address, phone number, a
person to contact regarding the return, purchase order number, the
type and quantity of equipment, a description of the problem and the
serial number(s).
Shipping to Manufacturer for Repair or Adjustment
All shipments of products should be made via United Parcel Service or
the best available shipper prepaid. The equipment should be shipped
in the original packing carton; if that is not available, use any suitable
container that is rigid and of adequate size. If a substitute container is
used, the equipment should be wrapped in paper and surrounded with
at least four inches of excelsior or similar shock-absorbing material. All
returns must include the return authorization number. Units sent for
repair or adjustment DO NOT need a return authorization number
Factory Service department
Telex Communications, Inc.
West 1st Street
Blue Earth, MN 56013 U.S.A.
Upon completion of any repair the equipment will be returned via
United Parcel Service or specified shipper collect.
Customer Service Department
Telex
12000 Portland Avenue South
Burnsville, MN 55337 U.S.A
Telephone: (952) 884-4051
Fax: (952) 884-0043