INSTRUCTIONS RMK-2002/RMF-2003
Parts List:
Digital Indicator Kit
RMK-2002/RMF-2003 for
2" focusers on TV-76,
TV-85, TV-102, NP101
- Digital Indicator
- Indicator Dovetail
- Dovetail Channel
- Indicator Stop Bracket
- (2) Stop Bracket Screws
- Nylon Runners (washers)
- (2) Phillips Head Screws
- (2) Allen Keys
Installation
Step 1)Step 1)
Step 1) Remove the two but-
Step 1)Step 1)
ton head screws from the top
of the focuser body with the
provided Allen key.
Step 2)Step 2)
Step 2) Remove the two
Step 2)Step 2)
screw hole plugs from the
top of the focuser's draw
tube using a small jeweller's
screwdriver.
Step 3)Step 3)
Step 3) Place the Dovetail
Step 3)Step 3)
Channel over the focuser body
as shown and secure it using
the two phillips head screws.
Step 4)Step 4)
Step 4) Slide the Indicator
Step 4)Step 4)
Dovetail onto the back of
the Digital Indicator and lock
in place using the small Allen
key.
Step 5)Step 5)
Step 5) Slide the Indicator
Step 5)Step 5)
into the Dovetail Channel.
Step 6) Step 6)
Step 6) Slip the Nylon Wash-
Step 6) Step 6)
ers on to the Stop Bracket
Screws.
Step 7)Step 7)
Step 7) Place the Indicator
Step 7)Step 7)
Stop Bracket over the draw
tube with the stop towards
the Indicator.
Step 8)Step 8)
Step 8) Lock the Indicator
Step 8)Step 8)
Stop Bracket Screws.
Proceed with the adjustment
instructions.
Digital Indicator
Indicator
Dovetail
Step 4
Indicator
Stop
Bracket
Dovetail
Channel
Steps 1 & 2
Step 3
Step 5
Step 6
Step 7 & 8
Micrometer position
adjustment
Adjustment and Use
The Digital Indicator has
0.5" of travel. It is ideal to
set the shaft within the
middle of its travel range.
To do so: achieve a
rough focus with your telescope. Slide the indicator
against the stop until the
shaft has moved approximately half way through its
travel. Use the small Allen
key and tighten the two set
screws on the side of the
Dovetail Channel that contact the indicator Dovetail.
If the indicator needs more
or less adjustment room to
reach the stop, first determine if repositioning the Stop
Bracket will help. For more
adjustment, remove the digital indicator from the channel, loosen the set screws
(see step 4) and slide the
Indicator Dovetail in the necessary direction. Retighten
the set screws.
Turn the micrometer on
and zero it if necessary
Start critically focusing
the image. Take note of the
micrometer reading so you
may return to that position if
further adjustment does not
improve focus.
Details regarding the
use of the indicator can be
found on the instructions included with the unit.
The optional RSC-2320
cable plus TVFocus software
(download available at
www.TeleVue.com) permits
remote viewing of the
indicator's reading.
32 Elkay Drive, Chester, New York 10918 845.469.4551 www.televue.com