45
ENGLISH
1.- REFERENCES DESCRIPTION
Ref. 5081 .... Low gain BI amplifier
Ref. 5083 .... Low gain BIII amplifier
Ref. 5087 .... Mid Band amplifier
Ref. 5088 .... Upper Band amplifier
Ref. 5089 .... Hyper Band amplifier
Ref. 5099 .... DAB amplifier
Ref. 5082 .... FM Amplifier T03
Ref. 5084 .... Low gain UHF amplifier
Ref. 5094 .... High gain UHF amplifier
Ref. 5097 .... A.G.C. UHF amplifier
Ref. 5098 .... UHF amplifier high selectivity
Ref. 5086 .... UHF DTT amplifier
Ref. 5085 .... UHF DTT amplifier with coupler
Ref. 5080 .... IF Amplifier (950 - 2150 MHz)
Ref. 5498 .... Power supply (230 V ± 15 % - 50/60 Hz)
(24 V - 2,5 A)
Accessories:
Ref. 4061 .... Load“F” 75 ohm
Ref. 5073 .... Face plate
Ref. 5074 .... Link “F” connectors
Ref. 5071 .... Wall mount (10 mod. + P.S.U.)
Ref. 5239 .... Wall mount (12 mód. + P.S.U.)
Ref. 5072 .... Universal cabinet (10 mod. + P.S.U.)
Ref. 5069 .... Universal cabinet (14 mod. + P.S.U.)
Ref. 5235 .... Universal cabinet (22 mod. + P.S.U.)
Ref. 5301 .... 19” wall/sub-rack
Ref. 8250 .... 19” sub-rack
Ref. 5302 .... MATV headend cabinet
Ref. 5301
Ref. 5302
Refs. 5072, 5069, 5235
Ref. 8250
Page 4
46
2.- TECHNICAL SPECIFICATIONS
2.1.- VHF Single-channels
1.- Adjust CH13 (refer to channels table on page 21)
2.- Fordi= 50 dB (2 channels at 4 MHz)
Reference 5081 5083 5099 5087 5088 5089 Bandwidth (MHz) 7 7 / 16
(1)
37 7 7 8 Gain (dB) 50 ±2 50 ±2 45 ±3 58 ±2 58 ±2 58 ±2 Flatness (dB) < 1 < 1 < 3 < 1 < 1 < 1 Gain adjustment (dB) > 35 > 35 > 35 > 35 > 35 > 35 Rejection (n ±2) (dB) > 40 > 30 > 20 > 30 > 25 > 30 Output level (EN 50083-5) (dBµV) 123 123 -- 125 124 125 Output level (DAB) (dBµV) -- 112
(2)
114
(2)
-- -- --
Noise figure (dB) < 9 < 9 < 9 < 9 < 9 < 9 Consump. at 24Vcc (mA) 65 ±5 65 ±5 90 ±5 90 ±5 90 ±5 90 ±5 Preamp. max. current (24Vcc) (mA) 100 100 100 100 100 100
n
n+1 n+2n-1n-2
7 MHz14 MHz 14 MHz
n+3n-3
Rejection
n -3
Rejection
n +2
Rejection
n -2
Rejection
n +3
Page 5
47
ENGLISH
Ref. Band Chan. Channel
Freq. (MHz)
5081 B I 2 47 ... 54
3 54 ... 61 4 61 ... 68
Sub L1 68
...
75
Band L2 75
...
82
L3 82
...
89
5083
B III C5 174 ... 181
C6 181 ... 188 C7 188 ... 195 C8 195 ... 202
C9 202 ... 209 C10 209 ... 216 C11 216 ... 223 C12 223 ... 230
C13
216
...
232 (DAB-UK)
5099 DAB 195
...
232
Ref. Band Chan. Channel
Freq. (MHz)
5087 BS S1 104 ... 111
Mid S2 111 ... 118
S3 118 ... 125 S4 125 ... 132 S5 132 ... 139 S6 139 ... 146 S7 146 ... 153 S8 153 ... 160 S9 160 ... 167
S10 167 ... 174
5088
BS S11 230 ... 237
Upper S12 237 ... 244
S13 244 ... 251 S14 251 ... 258 S15 258 ... 265 S16 265 ... 272 S17 272 ... 279 S18 279 ... 286 S19
286
...
293
S20
293
...
300
Ref. Band Chan. Channel
Freq. (MHz)
5089 BS S21 302 ... 310
Hyper S22 310 ... 318
S23 318 ... 326 S24 326 ... 334 S25 334 ... 342 S26 342 ... 350 S27 350 ... 358 S28 358 ... 366 S29 366 ... 374 S30 374 ... 382 S31 382 ... 390 S32 390 ... 398 S33 398 ... 406 S34 406 ... 414 S35 414 ... 422 S36 422 ... 430 S37 430 ... 438 S38 438 ... 446 S39 446 ... 454 S40 454 ... 462 S41 462 ... 470
Page 6
48
2.2.- FM Amplifier
Reference 5082 Bandwidth (MHz) 87,5 - 108 Gain (dB) 35 ±3 Flatness (dB) < 3 Gain adjustment (dB) > 35 Rejection77 MHz and 120 MHz (dB) > 30 Output level (UNE - 523-79) (dBµV) 114 Noise figure (dB) < 9 Consumption at 24Vcc (mA) 65 ±5 Preamp. maximum current (24Vcc) (mA) 100
Page 7
49
ENGLISH
n
n+1 n+2n-1n-2
8 MHz16 MHz 16 MHz
n+3n-3
2.3.- UHF Single-channels
Notes:
- Especify channels on ordering.
- Rejection (n±1): measured between P
V N and PA N-1 or PA N and PV N+1, if N is the
adjusted channel and N+1 and N-1 are the channels inmediately above and below respectively.
Rejection
n-2
Rejection
n-3
Rejection
n+2
Rejection
n+3
Reference 5084 5094 5086 5085 (DTT) 5098 5097 Bandwidth (MHz) 8 8 16 24 32 40 32 6 8 Gain (dB) 48 ±2 57 ±3 50 ±3 57 ±2 52 ±3 57 ±3 Flatness (dB) < 1 < 1 < 3 < 3 < 2 > 1 Output level EN 50083-5 (dBµV) > 120 > 125 111 109 108 108 > 106 > 121
A:125 / D:118 Rejection (n ± 1) (dB) > 3 > 3 > 3 - > 15 > 3 Rejection (n ± 2) (dB) > 25 > 25 > 15 - > 50 > 25 Rejection (n ± 3) (dB) > 50 > 50 > 30 - - > 50 Rejection Vc ch 65 (dB) - - > 20 > 15 > 22 - ­Noise figure (dB) < 9 < 9 < 9 < 9 < 11 < 9 Gain adjustment (dB) > 30 > 30 > 30 > 30 > 30 20 Directivity (output mixing) (dB) - - - > 15 - ­Output through attenuation (dB) - - - < 1,2 - ­A.G.C. margin (dB) - - - - - 30 Consump. at 24Vdc (mA) 70 ±5 90 ±5 70 ±5 90 ±5 90 ±5 90 ±5 Pream. max. current (24Vdc) (mA) 100 100 100 100 100 100
Page 8
50
2.4.- IF Amplifier
* For the installation calculation, add the predicted LNB consumption
Reference 5080 Bandwidth (MHz) 47 - 862 950 - 2150 Gain (dB) --- 35 - 50 Output level (DIN V VDE 0855/12) (dBµV) --- 124 Rejection between inputs (dB) --- > 10 Return losses (dB) --- > 10 Insertion losses (dB) < 1.5 --­Input level (dBµV) > 100 --­Attenuation margin (dB) --- > 20 Equalisation margin (dB) --- > 12 Noise figure (dB) --- 12.5 Consumption at 24Vcc (just amplifier)* (mA) --- 130 LNB current (input 2) (mA) --- 400 max.
Reference 5498 Mains voltage (V~) 230 ± 15 % Frequency (Hz) 50 / 60 Maximum power (W) 70 Output voltage (V=) 24 Maximum output current (A) 2.5 (24V) Maximum output power (W) 60
2.5.- Power Supply Unit
Page 9
51
ENGLISH
3 .- MOUNTING
3.1.- Wall Mounting
PWR
1
2
CLAC!
5498
Single channel amplifiers
5071 5239
4061
5074
Signal output
Signal input
Page 10
52
PWR
3.2.- 19” Rack Mounting
5073
8250
5301
CLAC!
Page 11
53
ENGLISH
4. - DESCRIPTION OF ELEMENTS
4.1.- Single-channels
1.- RF input loop (+ 24Vdc)
2.- Input for the mixing of other RF channels
3.- RF output
4.- Preamplifier power switch (On/Off)
5.- ON LED
6.- Attenuator
7.- Mains connector
1
2
3
5
6
4
7
ref. 5085
ref. 5080
1.- RF input loop (+ 24Vdc)
2.- RF output loop
3.- Preamplifier power switch (On/Off)
4.- Switch to select the analogue or digital channels (only ref. 5097)
5.- Output level adjustment
6.- Mains connector
7.- ON LED
1
2
4
6
7
5
3
1
3
2
4
PWR
7
9
10
8
5
6
1.- IF Input
2.- IF input + Vlnb/22KHz
3.- MATV input
4.- IF output + MATV
5.- Equaliser
6.- 0/22 KHz tone
7.- Selection of LNB current (Disabled / vertical (12V) / horizontal (18V))
8.- ON LED
9.- Attenuator
10.- Powering connector
Page 12
54
Single-channel amplifiers with diecast chassis and “F” connectors that can be rack or wall mounted.
The loop-through technique is used to mix the output signal from the units.
The connection between the supply and the modules, and between the modules them­selves, is carried out via interconnecting links.
They also dispose of a bypass current via the input connectors to power the preampli­fiers. This means that they can be disabled using the switch located on the front of the equipment.
When various modules are used in an installation, the channels with higher frequencies must be located near to the output that is to be used.
(Only ref. 5085)
With ref. 5085, given the output directivity, the mixing with the other channels in the installation is carried out via connector “2” and the output of the single channel, via connector “3”.
(Only ref. 5098)
If the installation uses amplifiers ref. 5098, the adjacent channel modules should not be mounted together (see application example
6).
(Only ref. 5097)
After installing the modules, it is necessary to adjust the output level using the multi­turn potentiometre "5" that is located on the front of the unit. The output level will remain constant because of the units' AGC.
The amplifier can work with analogue or digital channels, by selecting "A" or "D" on the "AGC" switch (4) depending on which type of channel is going to be amplified.
The front LED informs us about the signal levels at the input.
(Only ref. 5080)
An amplifier with 2 IF inputs. It disposes of a bypass current through the input connector (2) to feed the LNB. It is possible to choose between (7) vertical polarity powering, horizontal polarity powering or switch the power off, so as to be able to power it from the outside.
Also, this input has a 22KHz tone to control the LNB, that can be switched on at the front (6).
When only one of the inputs is in use, the other input should be charged with 75 .
When the LNB can be powered with either of the two levels (for example ref. 7477, LNB Quatro), is is advisable to select 18V.
In the output, it disposes of an input loop through connector (3) for mixing the headend’s MATV signal.
It also has an attenuator (9) and an equaliser (5) to treat the input signal and prepare it for the distribution conditions.
If there is a short-circuit or overconsump­tion, the amplifier warns the user - the LED begins to blink.
RED => Excessive signal
GREEN => Optimum signal
AMBER => Poor signal
LED colour
V
LNB
OFF Green
V
LNB
ON (13 or 18V) Amber
Short-circuit or overconsumption
Blinking
Page 13
(1)
PWR
(1)
+ 24V GND
55
ENGLISH
4.2.- Power Supply
ON LED
Mains input
230V~
Connector to power the modules (1)
Page 14
56
7.- APPLICATIONS
C58 C50 C46 C35 C30 C21 C10 C4 FM
FM C4 C10 C25 C36 C50 C58 FIC30
UHF
1.- General (FM + VHF + UHF) 2.- With IF single channel
VHF
FM
Preamplifier
+24V
RF output
SW. ON
Preamplifier switches OFF, except in Ch58 Preamplifier switches OFF, except in Ch58
5498 UHF VHF
DAB
5082
75 ohm
4061
UHF
VHF
FM
Preamp.
IF output + MATV
13V +22KHz
5498
5082
VHF DAB
UHF
5080
75 ohm
4061
Sw. “V”
Sw. “22KHz”
Page 15
57
ENGLISH
C22 C25 C28 C32 C35 C46 C50 C65 DTTFM
C22 C25 C28 C32 C35 C46 C50 C58 DTTFM
UHF
FM
FM
RF output
RF channel mixing
Preamplifier switches OFF
5498
5082
5085
5254
5084 5094 5097
75 ohm
4061
75 ohm
4061
Ch65
4093
Ch66
4093
5082
UHF
RF output
Preamplifier switches OFF
5498
5086
5084 5094 5097
3.- DTT with Ch 65 4.- DTT without Ch 65
Page 16
58
C28 C31 C34 C57 C48 C56 C45 C58FM
FM
75 ohm
4061
5082
UHF
RF output
Preamplifier switches OFF
5498
5.- With adjacent channels (Ch56, Ch57, Ch58)
(*)
Installations with AGC
C57 C59 C61 C63 C58 C60 C62 C64FM
FM
75 ohm
4061
UHF
RF output
Preamplifier switches OFF
5498
6.- Only with adjacent channels (Ch57, Ch58, Ch59, ... Ch64)
5098
5098
5084 5094 5097
(*)
Page 17
Garantía
Televés S.A. ofrece una garantía de dos años calculados a partir de la fecha de compra para los países de la UE. En los países no miembros de la UE se aplica la garantía legal que está en vigor en el momento de la venta. Conserve la factura de compra para determinar esta fecha. Durante el período de garantía, Televés S.A. se hace cargo de los fallos producidos por defecto del material o de fabricación. Televés S.A. cumple la garantía reparando o sustitu­yendo el equipo defectuoso. No están incluidos en la garantía los daños provocados por uso indebido, desgaste, mani­pulación por terceros, catástrofes o cualquier causa ajena al control de Televés S.A.
Garantia
Televés S.A. oferece uma garantia de dois anos calculados a partir da data de compra para os países da UE. Nos países não membros da UE aplica-se a garantia legal que está em vigor no momento da venda. Conserve a factura de compra para poder comprovar a data. Durante o período de garantia, Televés S.A. assume as falhas do produto ocorridas por defeito do material ou de fabrico. Televés S.A. cumpre a garantia reparando ou substituindo o equipamento defeituoso. Não estão incluídos na garantia os danos provocados pela utilização indevida, desgaste, manipulação por terceiros, catástrofes ou qualquer causa alheia ao controlo de Televés S.A.
Garantie
Televés S.A. offre une garantie de deux ans calculée à partir de la date d’achat pour les pays de l’U.E. Pour les pays non membres de l’U.E., la garantie appliquée sera celle en vigueur du point de vue légal au moment de la vente. Conservez votre facture d’achat afin d’attester de cette date. Pendant la période de garantie, Televés S.A. prend en charge les avaries dues à un défaut du produit ou de fabrication. Televés assume cette garantie en réparant ou en échangeant l’appareil défectueux. Ne sont pas couverts par la garantie les dommages provoqués par une utilisation incorrecte, usure normale d’utilisation, manipulation par des tiers, catastrophes ou toute cause hors du contrôle de Televés S.A.
Guarantee
Televés S.A. offers a two year guarantee, beginning from the date of purchase for countries in the EU. For countries that are not part of the EU, the legal guarantee that is in force at the time of purchase is applied. Keep the purchase invoice to determine this date. During the guarantee period, Televés S.A. complies with the guarantee by repairing or substituting the faulty equipment. The harm produced by improper usage, wear and tear, manipulation by a third party, catastrophes or any other cause beyond the control of Televés S.A. is not included in the guarantee.
Page 18
OPORTO
BARCELONA C.P. 08940 C/ Sant Ferrán, 27 Cornellá - Barcelona Telfs. 93 377 08 62 / 93 474 29 50 Fax 93 474 50 06 E-mail [email protected]
BILBAO C.P. 48150 Iberre kalea, módulo 16, pabellón 15-B Sangroniz-Sondika Tfnos. 94 471 12 02 / 94 471 24 78 Fax 94 471 14 93 [email protected]
A CORUÑA C.P. 15011 Gregorio Hernández 8. Tfnos. 981 27 47 31 / 981 27 22 10 Fax 981 27 16 11 [email protected]
GIJON C.P. 33210 C/Japón, 14 Tfnos : 985 15 25 50 / 985 15 29 67 Fax : 985 14 63 89 [email protected]
LAS PALMAS C.P. 35006 Gral. Mas de Gaminde 26. Tfnos. 928 23 11 22 / 928 23 12 42 Fax 928 23 13 66 [email protected]
MADRID C.P. 28005 Paseo de los Pontones 11. Tfnos. 91 474 52 21 / 91 474 52 22 Fax 91 474 54 21 [email protected]
MURCIA C.P. 30010 Polígono Conver C/ Rio Pliego 22 Tfnos. 968 26 31 44 / 968 26 31 77 Fax 968 25 25 76 [email protected]
SEVILLA C.P. 41008 Pol. Ind. Store - C/ A-6. Nave 5 Tfnos. 95 443 64 50 / 95 443 58 00 Fax 95 443 96 93 [email protected]
TENERIFE C.P. 38108 Avda. El Paso, 25 Los Majuelos - La Laguna. Tfnos. 922 31 13 14 / 922 31 13 16 Fax 922 31 13 33 [email protected]
VALENCIA C.P. 46020 Plaza Jordi San Jordi s/n Tfnos. 96 337 12 01 / 96 337 12 72 Fax 96 337 06 98 [email protected]
VIGO C.P. 36204 Escultor Gregorio Fernández, 5 Tfnos. 986 42 33 87 / 986 42 40 44 Fax 986 42 37 94 [email protected]
Rúa B. de Conxo, 17 - 15706 SANTIAGO DE COMPOSTELA
Tel. 981 52 22 00 Fax 981 52 22 62
www.televes.com
ALMERIA C.P. 04008
Campogrís 9. Tfno. 950 23 14 43 Fax 950 23 14 43 [email protected]
BURGOS C.P.09188 C/Real, s/n, San Adrián de Juarros Tfno. 947 56 04 58 / 670 73 75 86
CACERES/ BADAJOZ
C.P. 06010 C/Jacobo Rodríguez Pereira, nº11-Oficina Tfno. 924 20 74 83 / 670 70 21 93 Fax. 924 20 01 15 [email protected]
GIRONA C.P. 17190 (Salt) Ramón Sambola. 9º Ent. 1ª. Tfno. 972 23 25 43 / 607 23 88 40 [email protected]
GRANADA
Tfno. 958 13 78 29 Móvil: 609 62 70 96 [email protected]
JAEN C.P. 23007 Hermanos Pinzón, 8-bajo Tfnos. 953 29 50 40 / 953 29 52 21
639 98 44 89 Fax 953 29 52 10 [email protected]
LA RIOJA C.P. 26004 San Prudencio 19. bajo Tfno. 941 23 35 24 Fax 941 25 50 78 [email protected]
MALAGA C.P.29004 Pol. Santa Barbara - C/ Fidias 13. Tfno. 95 223 98 81 Fax 95 217 37 30 [email protected]
MELILLA C.P.52006 Paseo Marítimo Mir Berlanga, 17 Edif. Antares, C, 4ºB Tfno. 600 45 35 13 Fax 600 43 35 14 [email protected]
NAVARRA C.P. (Pamplona) 31007 Avda. Sancho el Fuerte 9. Tfno. 948 27 35 10 Fax 948 17 41 49 [email protected]
P. DE MALLORCA C.P. 07007 Ferrer de Pallares 45. bajo D. Tfno. 971 24 70 02 Fax 971 24 53 42 [email protected]
SALAMANCA ZAMORA VALLADOLID C.P. 47008
C/ Arrecife 12. Tfno. 983 22 36 66 Fax 983 22 36 66 [email protected]
HUESCA ZARAGOZA C.P. 50002
C/ Monasterio de Alahón 1-3. Tfno. 976 41 12 73 Fax 976 59 86 86 [email protected]
TELEVES MIDDLE EAST FZE
P.O. Box 17199 JEBEL ALI FREE ZONE DUBAI, UNITED ARAB EMIRATES Tel. 9714 88 343 44 Fax. 9714 88 346 44 [email protected]
TELEVES FRANCE S.A.R.L.
35 Av St Germain des Noyers 77400 St Thibault des Vignes (France) Tel. 01 60 35 92 10 Fax 01 60 35 90 40 [email protected]
TELEVES UNITED KINGDOM LTD
Unit 11 Hill Street, Industrial State CWMBRAN, GWENT NP44 7PG. (United Kingdom) Tel. 44 01 633 87 58 21 Fax 44 01 633 86 63 11 [email protected]
TELEVES ELECTRONICA PORTUGUESA MAIA - OPORTO
Via . Dr Francisco Sa Carneiro. Lote 17. ZONA Ind. MAIA 1. Sector-X MAIA. C.P. 4470 BARCA Tel. 351 22 9418313 Fax 351 22 9488719 / 9416180 [email protected]
LISBOA
C.P. 1000 Rua Augusto Gil 21-A. Tel. 351 21 7932537 Fax 351 21 7932418 [email protected]
DELEGACIONES
SUCURSALES
103554/0 - 04-01
LISBOA
VIGO
OURENSE
ZAMORA N
HUELVA
LUGO
GIJON
CACERES
BADAJOZ
CADIZ
LEON
VALLADOLID
ZAMORA
SALAMANCA
CORDOBA
SEVILLA
CEUTA
CANTABRIA
PALENCIA
AVILA
TOLEDO
CIUDAD REAL
GRANADA
MALAGA
BURGOS
SEGOVIA
GUADALAJARA
MADRID
JAEN
SORIA
MELILLA
BILBAO
ALAVA
LA RIOJA
NAVARRA
CUENCA
ALBACETE
ALMERIA
GUIPUZCOA
ZARAGOZA
MURCIA
HUESCA
TERUEL
CASTELLON
VALENCIA
ALICANTE
TARRAGONA
GIRONA
BARCELONA
PALMA DE MALLORCA
BALEARES
SUCURSALES
DELEGACIONES
FABRICAS
CANARIAS
TENERIFE
A CORUÑA
SANTIAGO
LAS PALMAS
Loading...