INSTRUCTION MANUAL
MP7ER/FR Remote
Double Inverted Magnetron
Cold Cathode Gauge
Range: 7ER 10-8 to 10-2 Torr
7FR 10-11 to 10-2 Torr
TELEVAC
A DIVISION OF THE FREDERICKS COMPANY
2400 PHILMONT AVE.
HUNTINGDON VALLEY, PA 19006
1 1 7ER/FR Remote Cold Cathode Electronics
Cable (specified at ordering)
phone: (215) 947-2500 fax: (215) 947-7464 e-mail: sales@televac.com web site: www.televac.com
9/11
CHAPTERS TITLE PAGE
01. DESCRIPTION and INSTRUMENT OPERATION ……………………………………….2
02. SAFETY …………………………………………………………………………………..3 & 4
03. PRINCIPLES OF SENSOR OPERATION …………………………………………………4
04. SENSOR OPERATION AND SENSOR INSTALLATION …..……………………….5 & 6
05. RECORDER OUTPUTS ……………………………………………………………………..7
06. MAINTENANCE ………………………………………………………………………….8 & 9
07. CALIBRATION ……………………………………………………………………………… .9
08. TROUBLESHOOTING …………………………………………………………………….…9
09. SPECIFICATIONS …………………………………………………………………………..10
10. DIMENSIONS ………………………………………………………………………………..11
11. UNPACKING AND INSPECTION ………………………………………………………….12
12. WARRANTY INFORMATION ………………………………………………………………12
PLEASE READ THIS MANUAL THOROUGHLY BEFORE USING GAUGE. REPORT ANY
PROBLEMS IMMEDIATELY.
phone: (215) 947-2500 fax: (215) 947-7464 e-mail: sales@televac.com web site: www.televac.com
9/11
1
Description and Instrument Operation
The MP7ER/FR series Remote Module provides a compact stand-alone measurement solution for
applications that do not require traditional panel-mounted instrument readouts. These modules
can provide local readout and control or can be interfaced directly with a PLC, chart recorder, or
data acquisition system. The MP7ER/FR series of instruments use the time proven reliable and
rugged TELEVAC 7ER/FR Sensor, which can be changed in seconds. These instruments operate
from low voltage DC and are easily integrated into the largest process system with a minimal
effort. Likewise, the MP7ER/FR Remote Gauge can be used as a small stand-alone vacuum
measurement solution.
Features
» Wide range 10-2 to 10-11 Torr
» Fast restart at high vacuum
» No x-ray limit
» Reduced external magnetic field
» Compact design
» Rugged/durable
» No-filament burnout
» No degassing required
» Long life
» Cleanable sensor (7ER)
phone: (215) 947-2500 fax: (215) 947-7464 e-mail: sales@televac.com web site: www.televac.com
9/11
2
These safety alert symbols in this manual or on the Product rear panel mean
cautions - personal safety, property damage or danger from electrical shock.
Read these instructions carefully.
Failure to comply with these instructions may result in serious personal injury, including
death, or property damage.
The service and repair information in this manual is for the use of Qualified Service
Personnel. To avoid shock, do not perform any procedures in this manual or perform any
Servicing on this product unless you are qualified to do so.
To reduce risk of fire or electric shock, do not expose this product to rain or moisture.
Safety Instructions
START BY READING THESE IMPORTANT SAFETY INSTRUCTIONS AND NOTES collected here
for your convenience and repeated with additional information at appropriate points in these instructions
In these instructions the word “product” refers to the MP7ER/FR and all of its approved parts and
accessories.
NOTE: These instructions do not and cannot provide for every contingency that may arise in
connection with the installation, operation, or maintenance of this product. Should you require
further assistance; please contact Televac at the address on the title page of this manual.
This product has been designed and tested to offer reasonably safe service provided in it’s
installed, operated and serviced in strict accordance with these safety instructions.
These safety precautions must be observed during all phases of operation, installation, and service of this
product. Failure to comply with these precautions or with specific warnings elsewhere in this manual
violates safety standards of design, manufacture, and intended use of the instrument. Televac disclaims
all liability for the customer’s failure to comply with these requirements.
√ READ Instructions – Read all safety and operating instructions before operating the product.
√ RETAIN instructions – Retain the Safety and Operating Instructions for future reference.
√ HEED warnings – Adhere to all warnings on the product and in the operating instructions.
√ FOLLOW instructions – Follow all operating and maintenance instructions.
√ ACCESORIES – Do not use accessories not recommended in this manual as they may require
a technician to restore the product to its normal operation.
phone: (215) 947-2500 fax: (215) 947-7464 e-mail: sales@televac.com web site: www.televac.com
9/11
3