TELEVAC MP7ER, MP7FR Instruction Manual

phone: (215) 947-2500 fax: (215) 947-7464 e-mail: sales@televac.com web site: www.televac.com
9/11
INSTRUCTION MANUAL
MP7ER/FR Remote Double Inverted Magnetron Cold Cathode Gauge
Range: 7ER 10-8 to 10-2 Torr 7FR 10-11 to 10-2 Torr
TELEVAC
A DIVISION OF THE FREDERICKS COMPANY
2400 PHILMONT AVE. HUNTINGDON VALLEY, PA 19006
PARTS LIST
#
QTY
ITEM DESCRIPTION
1 1 7ER/FR Remote Cold Cathode Electronics
2
1
Cable (specified at ordering)
3
1
Instruction Manual
4
1
Sensor
1 2 4
3
phone: (215) 947-2500 fax: (215) 947-7464 e-mail: sales@televac.com web site: www.televac.com
9/11
TABLE OF CONTENTS
CHAPTERS TITLE PAGE
01. DESCRIPTION and INSTRUMENT OPERATION ……………………………………….2
02. SAFETY …………………………………………………………………………………..3 & 4
03. PRINCIPLES OF SENSOR OPERATION …………………………………………………4
04. SENSOR OPERATION AND SENSOR INSTALLATION …..……………………….5 & 6
05. RECORDER OUTPUTS ……………………………………………………………………..7
06. MAINTENANCE ………………………………………………………………………….8 & 9
07. CALIBRATION ……………………………………………………………………………… .9
08. TROUBLESHOOTING …………………………………………………………………….…9
09. SPECIFICATIONS …………………………………………………………………………..10
10. DIMENSIONS ………………………………………………………………………………..11
11. UNPACKING AND INSPECTION ………………………………………………………….12
12. WARRANTY INFORMATION ………………………………………………………………12
PLEASE READ THIS MANUAL THOROUGHLY BEFORE USING GAUGE. REPORT ANY
PROBLEMS IMMEDIATELY.
phone: (215) 947-2500 fax: (215) 947-7464 e-mail: sales@televac.com web site: www.televac.com
9/11
1
CHAPTER 1 TELEVAC
Description and Instrument Operation
The MP7ER/FR series Remote Module provides a compact stand-alone measurement solution for applications that do not require traditional panel-mounted instrument readouts. These modules can provide local readout and control or can be interfaced directly with a PLC, chart recorder, or data acquisition system. The MP7ER/FR series of instruments use the time proven reliable and rugged TELEVAC 7ER/FR Sensor, which can be changed in seconds. These instruments operate from low voltage DC and are easily integrated into the largest process system with a minimal effort. Likewise, the MP7ER/FR Remote Gauge can be used as a small stand-alone vacuum measurement solution.
Features
» Wide range 10-2 to 10-11 Torr » Fast restart at high vacuum
» No x-ray limit » Reduced external magnetic field » Compact design
» Rugged/durable
» No-filament burnout » No degassing required » Long life » Cleanable sensor (7ER)
phone: (215) 947-2500 fax: (215) 947-7464 e-mail: sales@televac.com web site: www.televac.com
9/11
2
These safety alert symbols in this manual or on the Product rear panel mean
cautions - personal safety, property damage or danger from electrical shock. Read these instructions carefully.
Failure to comply with these instructions may result in serious personal injury, including death, or property damage.
The service and repair information in this manual is for the use of Qualified Service Personnel. To avoid shock, do not perform any procedures in this manual or perform any
Servicing on this product unless you are qualified to do so.
To reduce risk of fire or electric shock, do not expose this product to rain or moisture.
CHAPTER 2 TELEVAC
Safety Instructions
START BY READING THESE IMPORTANT SAFETY INSTRUCTIONS AND NOTES collected here
for your convenience and repeated with additional information at appropriate points in these instructions
In these instructions the word “product” refers to the MP7ER/FR and all of its approved parts and accessories.
NOTE: These instructions do not and cannot provide for every contingency that may arise in connection with the installation, operation, or maintenance of this product. Should you require further assistance; please contact Televac at the address on the title page of this manual.
This product has been designed and tested to offer reasonably safe service provided in it’s installed, operated and serviced in strict accordance with these safety instructions.
These safety precautions must be observed during all phases of operation, installation, and service of this product. Failure to comply with these precautions or with specific warnings elsewhere in this manual violates safety standards of design, manufacture, and intended use of the instrument. Televac disclaims all liability for the customer’s failure to comply with these requirements.
READ Instructions – Read all safety and operating instructions before operating the product. RETAIN instructions – Retain the Safety and Operating Instructions for future reference. HEED warnings – Adhere to all warnings on the product and in the operating instructions. FOLLOW instructions – Follow all operating and maintenance instructions. ACCESORIES – Do not use accessories not recommended in this manual as they may require
a technician to restore the product to its normal operation.
phone: (215) 947-2500 fax: (215) 947-7464 e-mail: sales@televac.com web site: www.televac.com
9/11
3
Loading...
+ 9 hidden pages