General description
The MPEG-2 compression that brought a revolutionary advance in the transmission of picture and sound, by today was superseded by the MPEG-4 compression technique. On the customers’ intensive demand Teletechnika developed the new generation of its encoders, the MPEG-4 (H.264) Encoder. T his version of the equipmen t allows the transmiss ion of digital SD I with embedded audio using H.264 MPEG-4 PART10 compression. Digitalized and compressed voice and picture is composed to Single Program Transport Stream (SPTS). The outp ut tra nsp or t stream includes t he m ost imp orta nt PSI/S I tab les ( PAT, P M T, S DT, NIT), thus in s impler systems the encoder can be applied even without using a remultiplexer. Th is e dition contains a 100 Base-T Ethernet UDP/IP marked connector.
Structure
Features
Digital vide o and audio input: SD/HD-SDI (with stereo embedded audio)
Wide range of resolutions: 720x576i, 1280x720p, 1920x1080i
System bitrate adjustable range of 1000 … 15000 kbps
Audio bitrate adjustable between 32 and 384 kbps
PSI inserter included with editable parameters
Unicast / multicast UDP/IP output 100 Base-T full duplex mode ETH
Separated management port for configuration
Simple configuration in web browser
Informative, wide display
Low power consumption
3
Mechanical parameters, operation The height of the encoder is 1 unit (1U) with 19’’ width and is supplied with standard
power cable.
In case of rack-mounted usage, the operator should take care of the proper airflow and ventilation! Do not cover the case because it could cause overheating!
Hardware structure
Front Panel:
State indicator LEDs LCD
State indicator LEDs: Power OK
TS proper
Encoder setting, boot procedure Serious internal problem
LCD: 2 line 40 character alphanumerical display, representing the state of the equipme nt on 12 pages:
1
st
page: TS MAC Address: The MAC address of the UDP/IP marked ETH port. TS IP:Port: The IP address of the UDP/IP marked port separated by a colon is the port.
2
nd
page:
Target IP:Port: The IP address of the destination side (DECODER) and the port on which
the decoder detects and filters.
Gateway IP: The IP Address of gateway if we use ‘Through gateway’ TS sending
(See below!)
4
3rd page: Multicast MAC Address: The MAC Addres s of multicas t sending in ‘To mult icast’ mode in
hexadecimal format.
Streaming mode: Stopped: No TS output
Unicast to IP: TS sending in the local network without
gateway
Through Gateway: TS send ing through a gateway if we use a
router to connection
To Multicast: TS sending to Multicast destination
4
th
page: System bitrate: The set full TS bitrate in kilobits per second (=kbps). Video bitrate: Comes from t he system b itrate and aud io bitr ate. Also depe nds o n
the PSI tables.
5
th
page: Audio bitrate: The rate of the audio coding in kbps, possible values are: 32, 48, 56, 64, 80, 96, 112, 128, 160, 192, 224, 256, 320, 384 Audio Status: Indicates that there are embedded audio: Present or not: Muted
6
th
page: The set PID values: PMT, VIDEO, AUDIO, PCR shown in hexadecimal format. The possible
values of PIDs are in 0x0020 … 0x1FFF range.
7
th
page: Program ID: The Pr ogra m ide nti fier in hex ade cima l for mat. The p oss ible va lu es
of this ID are in full 0x0000 … 0xFFFF range.
Program Provider: The name of program provider in maximum 20 characters.
8
th
page: Program Name: The name of the program in max. 20 characters. PSI Table Generator: Enabled / Disabled: The enabling of PSI tables. They contains: PMT PID, Program ID, Program Provider, Program Name, Stream
ID, Network ID, Repetition Time, Network Name
5
9
th
page: Stream ID: The identifier of the TS in hexadecimal format. The possible values
of this ID are in full 0x0000 … 0xFFFF range. Repetition T: Repetition time of PSI table. Network Name: The na me o f t h e ne t wor k i n max. 20 characters.
10
th
page: MGMT IP: The IP address of the configuration port. MASK: The network mask of the configuration port.
11
th
page: MGMT Gateway: The Gateway IP address of the configuration port. MGMT MAC address: The factory constant MAC address of the configuration port in
hexadecimal format.
12
th
page: TRAP IP Address: SNMP trap destination IP address which to the equipment throws
the alarm traps. (In future feature)
TRAP server is: OFFLINE / ONLINE: The Encoder can ping the server or not.
6
Rear Panel:
230V AC: 230V power connector (cable included) 1AT: 1 Amper ’T’ type fuse, removable POWER: Supply switch MGMT: Management 10/100 Base-T Ethernet Port for configuration PGM: Programmer connector just for service purposes. UDP/IP: 100 Base-T Ethernet port for TS sending in UDP/IP packets. SDI IN: Serial Digital Interface: Formerly the SDI interface was used only for linking
professional video equipment within the studio at the transmission of uncompressed digital video signals. Today, the SDI interface can be found at the inputs and outputs of more and more equipment of cable television and other fields. Its great advantage is that one single coaxial cable can be used for transmitting the picture and sound. The standard BNC connector on the back panel of the MPEG-4 encoder is used for connecting the SDI signal. Over time the SDI transmission developed to a fairly wide range of standard family. The encoder supports the following formats: SD-SDI (SMPTE 259M, 270 Mbit / s), HD-SDI (SMPTE 292M, 1.485 Gbit / s). The transmission of sound (embedded audio) is provided in the form of additional data, according to SMPTE 272M (SD-SDI) and SMPTE 299M (HD-SDI).
Additional information: Due to the high bitrate use high-quality, double shielded coaxial cable, and try to minimize the length of the cable, although originally the standard guarantees hundreds of meters of transmission quality.
230V AC POWER MGMT PGM UDP/IP SDI IN
1AT
7
User manual
The equipment could be started by turning the power switch ON, located beside power connector. Af ter the turn on, the PO WER LED starts to light in case of fau ltless functio n. After the start the LCD informs the user about the main state of the equipment:
At first by the boot procedure in the 1
st
line with the ‘Teletec hnika Ltd. - MPEG4 HD
ENCODER’ label. I n the 2
nd
line are the ‘Initializing .......’ label. Pleas e wait by the boot sect ion
about 15-20 seconds. By successful start an ‘OK’ word will appear after the points. If we have some pr oblem a ‘REBOOT!’ word and the equipment reboots until the successfully boot occurs. Then, the previously described information displayed on the display.
Settings
The settings of the equipment only could be done via the MGMT connector. If there is only a cable between the equipment end the computer it must be a crosslink type, otherwise e.g. with a switch or router, the type of the used cable is not important.
To operate and reach the Encoder with our PC it has to be set into the sam e IP address range as the equipment. The factory IP address of the equipment is on the 10th page of LCD. The factory IP address begins with ‘192.168.1.’ with 255.255.255.0 mask.
8
Web surface
The general and IP settings of the equipment can be reached via our PC’s browser. Type the IP address into the browser’s heading and press enter.
At first an username / password window will appear. In factory settings there are not Username or Password. Please keep them clear and press Enter. After the first login every user can change the Username and the Password. After logging in we can see the following web page:
Parts of the page
1. Header:
Teletechnika official webpage can be reached by clicking the Teletec hnika logo at t he left corner. In the line beginning with ‘NIC’ is the detailed version number of the used firmware. After in the line beginning with ‘MAC’ we can see the equipment’s MAC address.
2. Menu bar (left): House icon: Home page Network: Network Settings Server: Server Settings Measure / Main parameters: Measured- and settable parameters of the equipment Apply Settings: Save the Network and Server settings
3. Content page:
Page of the currently used menu point. Reset this push the H ome icon and see the name and version number of the currently used equipment.
9
Network Settings
IP Configuration
Obtain IP address automatically: DHCP: automatic IP settings from the used DHCP server
Use the following IP configuration: Manu a l IP ne t wor k se t t i n g s: IP Address: IP address of the equipment’s MGMT port Subnet Mask: subnet mask of the equipment’s MGMT port Default Gateway: default MGMT gateway DNS Server: a DNS server’s address (not used)
10
Ethernet Configuration
(These set tings should not be c han ged!)
Auto Negotiate: Check box for automatic negotiation Speed: If Auto Negotiate is not checked give the parameters of the used network
10 or 100 Mbps Duplex: Duplex- or hal f-duplex mode of the two way communication
OK: Prepare for sending the network settings (if it is done it is marked with ‘DONE !’ line) The option to apply settings in the Settings menu, you must click Apply.
Server Settings
Telnet/Web manager Password: Set the password for entering to the web surface Retype Password: The password again for checking We couldn’t give user name therefore by the login always keep it the user name field empty. The password can be up to 4 digits. Note t h e password you specified, because without a password
11
reset operation is not possible without knowing the password.
Advanced
ARP Cache Timeout (secs): The timeout of the address resolution in seconds. TCP Keepalive (secs): Alive hold time of the TCP connection in seconds. Monitor Mode @ Bootup: Internal service mode enable / disable. CPU Performance Mode: The internal CPU Performance mode, you should be high. HTTP Server Port: The embedded web server port. Default: 80 MTU Size: Maximum packet size.
OK: On the Server Settings page Preparing to send (if the preparation has been 'Done!' Is shown in t he tab). The option to apply settings in the Settings menu, you must click Apply.
12
Measure / Main parameters:
Clicking this menu item in the web browser connects to the Encoder’s 10001 control TCP port.
The process of connecting a disconnected puzzle icon and the 'Connecting ...' label is marked:
If the connection is successfully a connected puzzle and a ’Connected’ label is displayed:
If you lose the connection with the device a disconnected puzzle again a ‘Disconnected’ label is displayed:
If you ha ve a physical relationship exists and st ill get Disconnected appears, make sure t hat only one browser is opened and the de vice is not busy on the TCP socket port, as well as to ge t to the 10001 port o n the device. I f a ll t h e conditions are now in terms of t he ne twor k device port access control and st ill get disconnected inscription try t o reconnect it click to another menu and the n come back. Make sure that Inter net Explor er is used, do not open a br ows er a nd a few sheets of the same Encoder device.
13
After a success ful c on nection to the content page, and configured t he device status parameter s ar e displayed:
The interface works: d ata quer y page whe n you open alwa ys hap pe ns, and it can be set to double click on the desired field and press Enter, and rewrite the content fix it, you can return with Escape. The measured information page is constantly updated each second.
14
Status field: This sectio n shows the meas ured parameters. The le ft side shows t he name of the p arameter. O n
the right side is the parameter. System Status: ‘OK’: Encoder module is works perfectly, ‘ERR’: Problem with the
encoder unit.
Video Status: ‘OK ’ : SD I v ide o signa l is connected, ‘Not Connected’: SDI video signal is
disconnected.
Video bitrate: The value of the video bitrate in kilobit per seconds. This value comes
from the system bitrate and audio bitrate. Also depends on the PSI tables.
Audio Status: Ind icate s that there are embedded audio: ‘Audio is Present’ or ‘No Audio’:
Muted
Settings field: In th is section can be set the par ameters. The left s ide shows the name of the parameter. O n the
right side can be change any parameter. Own IP: The IP address of the UDP/IP marked port Own MAC: The MAC address of the UDP/IP marked ETH port. Own TS Port: The source TS Port. Gateway IP: The IP Address of gateway if we use ‘Through gateway’
TS sending Target IP: The IP address of the destination side (DECODER). Multicast MAC: The MAC Addres s of multicast se nding in ‘To multicast’
mode in hexadecimal format. Stream Port: The destination port of TS. System Bitrate: The full TS bitrate in kbps. PMT, Video, Audio, PCR PID The PID values: PMT, VIDEO, AUDIO, PCR you can
specify in hexadecimal format. The possible values of PIDs
are in 0x0020 … 0x1FFF range. Program ID: The Program identifier in hexadecimal format. The possible
values of this ID are in full 0x0000 … 0xFFFF range. Program Provider: The name of the program provider in maximum 20
characters. Program Name: The name of the program in max. 20 characters. Stream ID: The identifier of the TS in hexadecimal format. The
possible values of this ID are in full 0x0000 … 0xFFFF
range.
15
Network ID: The identifier of the network in hexadecimal format. The possible
values of this ID are in full 0x0000 … 0xFFFF range. Repetition Time: Repetition time of PSI table. Network Name: The name of the network in max. 20 characters. Streaming mode: Stopped: No TS output
Unicast UDP TS: TS sending in the local network without
gateway
Through Gateway: TS send ing through a gateway if we use a
router to connection
Multicast UDP TS: TS sending to Multicast destination Audio bitrate: The rate of the audio coding in kbps, possible values are: 32, 48, 56, 64, 80, 96, 112, 128, 160, 192, 224, 256, 320, 384 PSI Table Generator: Enabled / Disabled: The enabling of PSI tables. They contains: PMT PID, Program ID, Program Provider, Program Name, Stream
ID, Network ID, Repetition Time, Network Name Device Power: ON: Normal operation mode, Reset: Do a reboot with the system. SNMP Trap Address: The destination IP Address of the SNMP traps.
If the IP address is green it m eans tha t the 'Trap Server Online' as
the quick t i p shows. If it is red the n the first server doe s n ot s e e the
device ('Trap Server Offline').
Loading...