Telenetics OM-AMPS-100 User Manual

Page 1
OMEGA
Communications Interface Cabinet
Model No. OM-AMPS-100
(including Model No. OM-MP8-100 8-Port Module Option and
Model No. OM-BAT-100 Battery Option)
Installation, Operation, and
0049−0706−000 B
Page 2
The products and programs described in this User’s Guide are licensed products of Telenetics Corporation. This User’s Guide contains proprietary information protected by copyright, and this User’s Guide and all accompanying hardware and documentation are copyrighted.
Telenetics Corporation does not warrant that the hardware will work properly in all environments and applications, and makes no warranty and representation, either implied or expressed, with respect to the quality, performance, merchantability, or fitness for a particular purpose.
Information in this User’s Guide is subject to change without notice and does not represent a commitment on the part of Telenetics Corporation. Telenetics Corporation assumes no responsibility for any inaccuracies that may be contained in this User’s Guide.
Telenetics Corporation makes no commitment to update or keep current the information in this User’s Guide, and reserves the right to make changes to this User’s Guide and/or product without notice.
No part of this manual may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying, recording, or information storage and retrieval systems, for any purpose other than the purchaser's personal use, without the express written permission of Telenetics Corporation.
Copyright 2001 Telenetics Corporation.
25111 Arctic Ocean
Lake Forest, California 92630
Tel: (949) 455-4000
Fax: (949) 455-4010
Page 3
Table of Contents
PREFACE ............................................................................................................... 7
Product Overview...................................................................................................................7
Ancillary Documentation.......................................................................................................9
SECTION 1 INSTALLATION ............................................................................... 11
Introduction..........................................................................................................................13
Hardware Features................................................................................................................13
Finding a Suitable Location .................................................................................................14
Avoiding Hazards.................................................................................................................15
Installing OMEGA...............................................................................................................15
Unpacking............................................................................................................................15
Required Materials and Tools..............................................................................................16
Mounting OMEGA..............................................................................................................16
Mounting an Antenna ..........................................................................................................17
Connecting the Input Voltage Source..................................................................................18
Connecting the Endpoint Device.........................................................................................20
Powering Up OMEGA ........................................................................................................21
Verifying the Cellular Transceiver Unit ..............................................................................22
Operating OMEGA..............................................................................................................22
Activating Your Cellular Transceiver..................................................................................22
Call Origination Testing ......................................................................................................22
Call Answer Testing ............................................................................................................23
SECTION 2 TROUBLESHOOTING..................................................................... 25
Troubleshooting ...................................................................................................................27
Checking the Main Power Supply........................................................................................27
Checking the Antenna..........................................................................................................28
Checking the Battery Voltage ..............................................................................................28
Reinitializing OMEGA ........................................................................................................28
SECTION 3 SPECIFICATIONS ............................................................................ 29
Specifications.......................................................................................................................31
Operation.............................................................................................................................31
Modem Interface..................................................................................................................31
Cellular Transceiver Interface..............................................................................................32
Battery Operation ................................................................................................................32
Switches and LED Indicators .............................................................................................. 33
Power Supply.......................................................................................................................33
Mechanical Specifications...................................................................................................34
OMEGA Operation, and Maintenance Manual iii
Page 4
Table of Contents
Connectors...........................................................................................................................34
Environmental Specifications..............................................................................................34
Agency Compliance.............................................................................................................35
SECTION 4 USING THE CONFIGURATION PROGRAM.....................................37
Introduction..........................................................................................................................39
Prerequisites.........................................................................................................................39
Getting Started......................................................................................................................40
Reading the Cellular Telephone Signal................................................................................41
Programming a Telephone Number.....................................................................................42
Entering the Cellular Telephone’s SID................................................................................43
Changing the Login Password..............................................................................................43
Exiting the Configuration Program......................................................................................44
SECTION 5 EXTERNAL ANTENNA GUIDELINES...............................................45
Introduction..........................................................................................................................47
General Guidelines...............................................................................................................47
High Voltage Areas .............................................................................................................47
RF Signal.............................................................................................................................47
Gain .....................................................................................................................................47
External Antenna Selection Criteria.....................................................................................48
Antenna Placement..............................................................................................................48
Distance from the Antenna to the Closest Cell Site.............................................................48
Degrees of Down-tilt on the Cell Site Antenna Array.........................................................48
Obstacles between the Antenna and Cell Site......................................................................48
Electrical Interference..........................................................................................................49
Distance from the Antenna to OMEGA...............................................................................49
Height Above Ground Level of the Antenna.......................................................................49
Cable for Connecting the Antenna to OMEGA...................................................................49
Types of External Antennas.................................................................................................50
Directional Antenna............................................................................................................ .50
Elevated Feed 3dB Gain Antenna........................................................................................50
Determining the Best External Antenna Location ...............................................................51
Contact Information .............................................................................................................51
APPENDIX A 8-PORT EXPANSION MODULE OPTION......................................53
Introduction..........................................................................................................................55
Package Contents .................................................................................................................55
Field Installation...................................................................................................................55
Testing the Module Ports .....................................................................................................58
Connecting Endpoint Devices..............................................................................................58
Time Delay Method (Automatic Connection) .....................................................................58
Second Dial Tone Method (Manual Connection)................................................................59
iv OMEGA Installation, Operation, and Maintenance Manual
Page 5
Table of Contents
Specifying a Default Port.....................................................................................................60
Anti-streaming......................................................................................................................61
Command Summary.............................................................................................................62
APPENDIX B WARRANTY & COMPLIANCES.................................................... 63
Warranty and RMA Statement.............................................................................................65
FCC Statement .....................................................................................................................67
FCC Interference Statement.................................................................................................67
FCC Part 15 Statement ........................................................................................................67
Comments About This Manual............................................................................................68
INDEX.................................................................................................................... 69
OMEGA Installation, Operation, and Maintenance Manual v
Page 6
Table of Contents
Notes
vi OMEGA Installation, Operation, and Maintenance Manual
Page 7
Preface
This User’s Guide describes how to install, operate, and troubleshoot the Telenetics OMEGA Interface Cabinet. OMEGA is a state-of-the-art, highly integrated communication interface devices.
Communications
P
The Telenetics OMEGA family of Communication Interface Cabinets are highly integrated units that provide the functions required to link a single or multiple remote endpoint devices (such as meters, RTUs, and protective relays) to a central host computer. Communication links between OMEGA and the host computer can be provided by conventional land line or wireless cellular transceivers.
Product Overview
OMEGA is a standalone, single-channel unit that provides a wireless cellular connection for using an endpoint device equipped with an internal dial-line modem (see Figure P-1). The connection’s data rate depends on the type of modem at the endpoint device and the quality of the cellular connection.
Telenetics offers an optional 8-port module for OMEGA which provides connection for up to eight endpoint devices equipped with an internal dial-line modem. The optional 8-port module is ideal for locations such as apartment complexes or strip malls that have multiple endpoint devices. For more information, please contact Telenetics.
OMEGA Operation, and Maintenance Manual 7
Page 8
Preface
Figure P-1. OMEGA Application
OMEGA is a fully integrated package consisting of a 3 Watt cellular transceiver, telephone-line interface, low-profile antenna, 90 to 264VAC power supply, and maintenance-free, rechargeable power back-up battery. The enclosure is made from impact­resistant polycarbonate and is NEMA 4X certified.
The following list summarizes OMEGA’s features.
Telephone-line interface emulation for an endpoint device
c
equipped with an internal modem.
Optional 8-port module for connecting up to eight endpoint
c
devices equipped with an internal dial-line modem.
Cellular transceiver for providing an analog channel to a
c
modem at the host location.
Large-capacity rechargeable battery for providing back-up
c
power to the cellular transceiver.
High-isolation voltage power-supply unit (8 K Volts).
c
8 OMEGA Installation, Operation, and Maintenance Manual
Page 9
Wide-range input voltage switching power supply (90 to 277
c
VAC).
Standard built-in directional antenna; optional directional
c
external antenna.
Impact-resistant, NEMA 4X non-metallic enclosure.
c
Ancillary Documentation
In addition to this manual, the OMEGA documentation suite includes the following additional documents:
OMEGA
c
Guide (Telenetics part number 0049-0706-002)
OMEGA
c
(Telenetics part number 0049-0706--005)
OMEGA 8-Port Line-Sharing Module Model OM-MP8-100
c
Quick Start Guide (Telenetics part number 0049-0706-001)
Communications Interface Cabinet Quick Start
External Antenna Mounting Kit Installation Guide
OMEGA Installation, Operation, and Maintenance Manual 9
Page 10
Preface
Notes
10 OMEGA Installation, Operation, and Maintenance Manual
Page 11
Section 1 Installation
Section 1 Contents
Hardware Features...............................13
Finding a Suitable Location ................14
Avoiding Hazards................................15
Installing the OMEGA........................15
Operating the OMEGA .......................22
OMEGA Installation, Operation, and Maintenance Manual 11
Page 12
Section 1 Contents
12 OMEGA Installation, Operation, and Maintenance Manual
Page 13
Section 1 Contents
Introduction
This section describes how to install the OMEGA communications interface cabinet.
1
Hardware Features
Figure 1-1 shows the hardware features of OMEGA. The Battery and Battery Power Switch are options that can be ordered from Telenetics.
Figure 1-1. OMEGA
OMEGA Operation, and Maintenance Manual 13
Page 14
Section 1 Contents
Finding a Suitable Location
Because OMEGA is a wireless solution, it is not possible to predict how it will perform in all given environments. However, observing the following guidelines will help optimize performance in your environments and applications.
Selecting a location for installing OMEGA.
c
The location must provide adequate cellular coverage and
signal strength (preferably –90 dBm or better). It is quite common that in certain locations such as basements, below­street-level locations, and between hills and rural areas, the receive signal might be inadequate for cellular communications. In these cases, use an optional YAGI or elevated-feed antenna to improve reception (see Section 5 for more information). You can use the OMEGA configuration application to evaluate the cellular telephone’s receive signal strength (see Section 4).
Be sure there is sufficient space for OMEGA to connect to
the endpoint device. This distance should not exceed 500 feet.
Make sure there is sufficient space to work. The space
should be dry, away from overhead water pipes and free of airborne contaminants.
The location should place OMEGA within six feet of a
properly grounded AC outlet.
Remote antenna installation.
c
If you will be using a remotely located antenna, locate the antenna 10 feet above ground level and no more than 50 feet from the OMEGA unit (the shorter the distance, the better). Section 5 provides details about the external antenna installation process.
Avoid radio-frequency interference.
c
Consider the environment’s radio-frequency characteristics, including construction materials and the presence of windows and ducting. The radio-frequency field pattern may be influenced by nearby metal objects such as appliances, equipment, and metal wall framing.
14 OMEGA Installation, Operation, and Maintenance Manual
Page 15
Section 1 Contents
Installing multiple OMEGA units.
c
To avoid mutual interference when installing more than one OMEGA allow a minimum of four feet between OMEGA units.
Avoiding Hazards
When considering locations for installing OMEGA, avoid the following hazards.
Locations that prevent you from opening the OMEGA
c
enclosure completely, or prevent you from accessing and viewing the OMEGA components.
Locations that expose OMEGA to the elements, including
c
direct sunlight, rain, snow, and extreme humidity. While your OMEGA is ruggedized for extreme environments, we recommend that the location you select does not expose OMEGA to harsh conditions.
Locations prone to radio-frequency or electro-magnetic
c
interference from devices such as security gates, garage doors, and microwave ovens.
Water or other fluids that surround OMEGA or its cellular
c
transceiver antenna.
Installing OMEGA
After you select a suitable location for OMEGA, obtain cellular telephone service for OMEGA’s cellular transceiver. Then use the following procedures to install OMEGA.
Unpacking
The OMEGA package contains the following items:
One OMEGA unit
c
A diskette containing the OMEGA configuration program
c
(described in Section 4)
This manual
c
A Quick Start Guide
c
OMEGA Installation, Operation, and Maintenance Manual 15
Page 16
Section 1 Contents
Required Materials and Tools
You need the following materials to install the OMEGA unit:
Either screws or bolts to attach OMEGA to a mounting surface.
c
Washers to fit with the screws or bolts.
c
A ¾-inch plywood backplate if the mounting surface is dry
c
wall.
Have the following tools available for installing the OMEGA unit:
Appropriate tools for the hardware you are using to mount the
c
unit (for example, a screwdriver and wrench).
Flex–type conduit if you are installing the unit outside.
c
Optional: a telephone handset.
c
NOTE:
In addition to the tools above, the OMEGA cellular phone must be activated, either by Telenetics or a cellular service provider. If Telenetics does not activate the OMEGA cellular phone, use the supplied OMEGA configuration program or the optional OmegaMate to configure the phone’s electronic serial number (ESN) and phone number.
Mounting OMEGA
Mount and secure OMEGA to a wall or panel using the supplied fasteners (see Figure 1-2). Any additional hardware required to mount OMEGA on a wall or panel must be user-supplied.
Your OMEGA may look different than the one in Figure 1-2.
16 OMEGA Installation, Operation, and Maintenance Manual
Page 17
Screw
Box
Section 1 Contents
Washer
Wall
Side view Back view
Figure 1-2. Mounting OMEGA
Mounting an Antenna
If your OMEGA does not have an antenna preinstalled.
Remove the nylon nut at the base of the antenna. You will use
1.
this nut to secure the antenna to OMEGA. Do not remove the washer located between the nut and the antenna.
Open the OMEGA enclosure and insert the antenna wire
2.
through the OMEGA antenna hole. Then rest the antenna on the OMEGA antenna hole. The bottom of the antenna should protrude through the antenna hole.
Attach the antenna wire to the SMA connector on the OMEGA
3.
transceiver. Hold the cone part of the antenna with one hand. Then use your
4.
other hand to fasten the nut to the bottom of the antenna protruding through the antenna hole. This will secure the antenna to the OMEGA enclosure.
OMEGA Installation, Operation, and Maintenance Manual 17
Page 18
Section 1 Contents
IMPORTANT: Be sure the nut is aligned with the top of the
OMEGA enclosure. If the nut is not parallel to the top of the enclosure, the OMEGA top cover will not close completely.
Connecting the Input Voltage Source
The following procedure describes how to connect OMEGA to an input voltage source of 90 - 277 VAC. When making this connection, use a UL-listed and approved power cord with a rating of 10 amps or above.
The OMEGA enclosure is pre-drilled with a hole that is .875 inches in diameter. This hole is used to accommodate a standard AC power cord and the conduit for the power cable running between the power source and the OMEGA unit.
1. Lift the AC fuse connector to turn off AC power to OMEGA
(see Figure 1-1 on page 13). Do not close this AC fuse connector when connecting the input voltage source.
2. Insert the power cord through the conduit hole at the bottom of
the compartment (see Figure 1-3).
18 OMEGA Installation, Operation, and Maintenance Manual
Page 19
Section 1 Contents
Figure 1-3. Connecting an Input Voltage Source
NOTE:
WARNING!
3. Strip the wires that will be making contact with OMEGA from
.25 to .40 inches. Then connect the power supply source to the 3-position terminal block on OMEGA by connecting the hot, neutral, and ground wires as follows:
- The hot and neutral wires should be on the fused right side.
- The ground wire should be on the left (green/yellow) side.
OMEGA has two 2A slo-blo fuses. To accesses the fuses, lift the power connector handles as shown in Figure 1-3.
The ground wire between OMEGA and earth ground must be as short as possible. Ensure that the ground wire makes contact with earth ground.
OMEGA Installation, Operation, and Maintenance Manual 19
Page 20
Section 1 Contents
P
O
W
E
R
S
T
A
T
U
S
Figure 1-4. Connecting an Input Voltage Source
4. Secure the ground wires by tightening the screws located in the
small holes of the AC fuse connectors, as shown above.
Connecting the Endpoint Device
To connect an endpoint device to OMEGA:
1. Insert the modem cable from the endpoint device through the
conduit hole at the bottom of the compartment.
2. If the OMEGA 8-Port Line-Sharing Module is not installed,
connect the cable to the single RJ-11 jack located near the conduit hole (see Figure 1-1 on page 13). Otherwise, refer to the
OMEGA 8-Port Line-Sharing Module Quick Start Guide
(Telenetics part number 0049-0706-001)
.
20 OMEGA Installation, Operation, and Maintenance Manual
Page 21
Section 1 Contents
Powering Up OMEGA
After making the connections described in the previous sections, use the following procedure to power up OMEGA.
WARNING!
LED Status and Description
Do not remove the antenna from OMEGA and never apply power to the cellular unit without the antenna attached. The cellular transceiver may be permanently damaged by an unloaded transmitter.
1. Before applying power to OMEGA set the Power Battery
switch to the OFF position and lift the AC fuse connector (see Figure 1-1 on page 13).
2. Connect the red lead to the + battery terminal and the black
lead to the − battery terminal.
3. Apply the 90-277 VAC power source to OMEGA.
4. Close the AC fuse connector and move the Battery Power
switch to the ON position (see Figure 1-1 on page 13).
5. Verify that the LEDs react as shown below.
Power
Status
If the
cellular signal. In these cases, we recommend that you use an external high­gain antenna, such as those available from Telenetics, to improve cellular performance.
Status
Steady green = normal operation. If this LED indicates a different status, refer to the troubleshooting procedures on page 27.
Fast green blinking = strong cellular signal (-90 dB or better). Slow green blinking = adequate cellular signal. Fast red blinking = poor cellular signal.* Slow red blinking = inadequate cellular signal.*
LED blinks red fast or slowly, it indicates a poor or unusable
OMEGA Installation, Operation, and Maintenance Manual 21
Page 22
Section 1 Contents
Verifying the Cellular Transceiver Unit
To verify that the cellular transceiver unit is working and communicating with the cellular service tower, confirm that the
Status
indicates that the cellular unit is receiving a strong signal. If the
slower), the cellular unit is receiving a weak signal. OMEGA might not transmit and receive data reliably if the cellular signal is weak. In this case, relocate OMEGA to a different location to improve cellular performance. You can also replace the OMEGA antenna with an external high-gain antenna that complies with the OMEGA specifications to improve reception, without jeopardizing the OMEGA warranty. Contact Telenetics for more information.
LED is blinking rapidly (twice a second or faster). This
Status
LED is OFF or blinking slowly (once a second or
Operating OMEGA
After you set up OMEGA, use the procedures in this section to test OMEGA’s originate and answer capabilities.
WARNING!
Before you perform the following call-origination and call­answering procedures, replace and hand-tighten the OMEGA cover. Otherwise, the antenna can interfere with OMEGA’s performance.
Activating Your Cellular Transceiver
To operate OMEGA the cellular transceiver must be activated for service. To activate the cellular transceiver, contact your cellular service and provide them with the OMEGA electronic serial number (ESN). The ESN is located on the bar code on the OMEGA cellular transceiver. The ESN is an 11-digit number that starts with 236 (i.e., 236-
IMPORTANT: The cellular phone number must be available to complete the
following procedures.
xxxxxxxx
).
Call Origination Testing
If the OMEGA 8-Port Line-Sharing Module is installed, use the call-testing procedures in the
Module Quick Start Guide
22 OMEGA Installation, Operation, and Maintenance Manual
OMEGA 8-Port Line-Sharing
. Otherwise, use the following procedure
Page 23
Section 1 Contents
and the one after it to test OMEGA’s ability to originate and answer calls.
IMPORTANT: If reception is poor, place the cover on
OMEGA to shield the transmission from radiating energy to the transceiver.
To test OMEGA’s ability to originate a call:
1. Disconnect the external modem from the OMEGA RJ-11
modem jack.
2. Connect a standard telephone to the OMEGA RJ-11 modem
jack. This jack is located on the side opposite the cellular transceiver connector (see Figure 1-1 on page 13).
3. Use the telephone to dial a call. If you make a connection, it
indicates that the OMEGA cellular transceiver can originate calls.
NOTE:
The modem that came with the endpoint device may provide additional ways to test the modem’s dial-out capabilities. Refer to the manual that came with the modem for more information.
Call Answer Testing
To test OMEGA’s ability to answer a call:
1. With the telephone connected to the OMEGA modem RJ-11
jack, use another telephone to call OMEGA. The telephone attached to OMEGA should ring.
2. Remove the telephone and reconnect the endpoint device to the
modem jack connection on OMEGA. Have a remote modem call OMEGA. The modem connected to OMEGA should answer the call automatically.
If the modem fails to automatically answer the calls, make sure the modem used with the endpoint device is configured for auto­answer (refer to the manual that came with the modem for more information).
OMEGA Installation, Operation, and Maintenance Manual 23
Page 24
Section 1 Contents
Notes
24 OMEGA Installation, Operation, and Maintenance Manual
Page 25
Section 2 Troubleshooting
Section 2 Contents
Checking the Main Power Supply.......27
Checking the Antenna.........................28
Checking the Battery Voltage.............28
Reinitializing the OMEGA..................28
OMEGA Operation, and Maintenance Manual 25
Page 26
Section 2 Contents
26 OMEGA Installation, Operation, and Maintenance Manual
Page 27
Section 2 Contents
Troubleshooting
This section describes troubleshooting procedures to follow in the unlikely event you encounter a problem with OMEGA. The following procedure summarizes the steps to follow to troubleshoot OMEGA.
1.
Check the main power supply (see “Checking the Main Power Supply,” below).
2
2.
Verify that the cellular transceiver is operating properly (see “Call Origination Testing” on page 22 and “Call Answer Testing” on page 23).
3.
Verify that the antenna is operating (see “Checking the Antenna” on page 28).
4.
For OMEGA units equipped with the Battery option, verify that the battery voltage is working properly (see “Checking the Battery Voltage” on page 28).
5.
Verify that OMEGA can originate calls (see “Call Origination Testing” on page 22).
6.
Verify that OMEGA can answer calls (see “Call Answer Testing” on page 23).
Checking the Main Power Supply
To check the main power supply:
1.
Unplug the main power at the source. Then check the two fuses under the safety cover (see Figure 1-1 on page 13). If you need to replace them, use the identical type of fuse (2 Amp SLO­BLO).
2.
Check that the wires are securely connected to the terminal block.
3.
Set OMEGA’s AC power to ON (see Figure 1-1 on page 13).
4.
With AC power applied to OMEGA verify that the green
Power
OMEGA Installation, Operation, and Maintenance Manual 27
LED is ON. Use a Voltmeter to check the DC voltage.
Page 28
Section 2 Contents
The voltage between the red and black terminals of the battery should be between +12.5 and +14.0 Volts.
Checking the Antenna
Make sure the antenna is securely fastened to the OMEGA cellular transceiver. Hand-tighten the antenna to ensure that it is securely connected to the transceiver. If it is, use the procedures under “Call Origination Testing” on page 22 and “Call Answer Testing” on page 23 to verify antenna operation.
Checking the Battery Voltage
If your OMEGA contains the Battery option, use the following procedure to check the battery operation:
Move the Battery Power switch to the OFF position (see Figure
1.
1-1 on page 13). Lift the AC fuse connector to remove AC power from
2.
OMEGA. Check the voltage between the red and black terminals at the
3.
battery (see Figure 1-1 on page 13). The voltage should be approximately +12.5 to 13.0 Volts. This is the Voltage output of the battery without the load.
Move the Battery Power switch to ON and check the voltage
4.
again. The voltage should be between +12.0 and 12.5 Volts with the load. If the voltage for the battery terminal is below
11.5 Volts, the battery will need to be recharged or replaced.
Reinitializing OMEGA
There may be times when you need to initialize OMEGA. For example, you may want to reinitialize OMEGA in hopes of obtaining better cellular reception.
To initialize OMEGA, press the and checks OMEGA’s receive cellular signal strength for approximately one minute. During this time, OMEGA is inoperable and cannot originate or answer calls.
Test
button. This resets OMEGA
28 OMEGA Installation, Operation, and Maintenance Manual
Page 29
Section 3 Specifications
Section 3 Contents
Operation.............................................31
Modem Interface.................................31
Cellular Transceiver Interface.............32
Battery Operation................................32
Switches and LED Indicators..............33
Power Supply ......................................33
Mechanical Specifications...................34
Connectors...........................................34
Environmental Specifications .............34
Agency Compliance............................35
OMEGA Operation, and Maintenance Manual 29
Page 30
Section 3 Specifications
OMEGA Operation, and Maintenance Manual 30
Page 31
3
Section 3
Specifications
Specifications
This section describes the OMEGA specifications.
Operation
OMEGA is designed to connect a remote end point device equipped with an internal modem to a head end computer when a conventional land line is not available. The interface of the modem within the endpoint device must meet PSTN and FCC-68 requirements and be compatible with all standard TELCO handshake signaling.
Modem Interface
A standard RJ-11 modular jack connector provides the OMEGA’s modem interface. The connection is a standard 2-wire dial line interface that has the following specifications:
Output ring frequency: 18 ± 2 Hz Ring voltage: 70 volts peak to peak Maximum ringer’s equivalent: 2.0 B Dial tone frequency: 450 Hz +/- 50 Hz Dial tone level: 1.0 Volts +/- 20% ON/Off-hook current detection: >4 ma DTMF detection: Yes Pulse dialing support: Not supported
OMEGA Operation, and Maintenance Manual 31
Page 32
Section 3 Specifications
Cellular Transceiver Interface
The cellular transceiver meets the AMPS standard and conforms to the specifications below:
Model number: Wireless Link CVDM-3
with data and voice
interface module Operating Frequency: 824 to 893.9 MHz Number of Channels: 832 Operating voltage: 10.9 to 14.5 volts DC current requirements: 1.5 amp @ max. transmit
power, 100 ma @ stand-by RF output power: 3.0 Watts maximum Antenna impedance: 50 ohms Antenna type: 50 ohm, Omni-directional
VSWR is 1:2.0 or better
over operating frequency
Battery Operation
OMEGA is equipped with a maintenance-free rechargeable battery for continuous operation without interruption in the event that power to OMEGA is disabled.
Battery type: Rechargeable, Lead-Acid,
maintenance free Nominal output voltage: 12.0 to 12.8 Volts Charge voltage: 13.2 to 13.8 Volts Current capacity: 1.2 amp-hours minimum at
25° C Expected operation life: 5 years
Operating temperature: -40 to +70° C
32 OMEGA Installation, Operation, and Maintenance Manual
Page 33
Section 3
Specifications
Switches and LED Indicators
Toggle switches and LED indicators are provided for installation, configuration, and troubleshooting.
Switch controls: AC power ON-OFF
Battery ON-OFF
LED Indications: LED 1: AC Power/Battery Condition
LED 2: Cellular Connection Status
Power Supply
The switching power supply is designed to operate from a wide range of AC input voltages and is isolated against voltage transients.
AC power input: 90 to 277 VAC,
50 to 60 Hz DC power input: 100 to 150 VDC Output DC voltage: 13.2 volt DC +/- 5%, full
load Maximum output current: 2.0 amperes Power consumption: Idle: 1.3 Watts
Transmit @ 3 Watts: 16.5
Watts Primary to secondary insulation: 8,000 volts peak at 60 Hz Battery charge voltage: 13.8 Volts Input AC fuse rating: 2 amps Slow Blow, 250V Primary surge protection: 1500 Watt-seconds Secondary surge protection: 20 KvA
OMEGA Installation, Operation, and Maintenance Manual 33
Page 34
Section 3 Specifications
Mechanical Specifications
OMEGA is designed for indoor and outdoor installation. The enclosure is made of impact-resistant polycarbonate and provides NEMA 4X watertight protection. Mounting feet are provided for surface mounting.
Dimensions: 7.75” high (over antenna)
x 7.0” wide x 4.75” deep Mounting Centers: 7.50” x 7.50” (adjustable,
horizontal or vertical) Weight: 4.0 lbs. Protection: NEMA 4X, watertight,
dust-tight Flammability Rating: UL94-5V Color: Light gray
Connectors
AC Power Connector: Fuse holder screw
terminal block 22 – 10
AWG Device Connector: RJ-11 modular jack,
2-Wire Tip/Ring Battery Terminal: .187-inch, pushon Antenna: SMA connector
(factory connected)
Environmental Specifications
Operating Temperature: -30 to + 70o C
o
Storage Temperature: -40 to +85
C
Operating Humidity: 5 to 90 % non-condensing
34 OMEGA Installation, Operation, and Maintenance Manual
Page 35
Specifications
Agency Compliance
EMI/RFI: FCC-15 Class A computing devices UL: UL 1950 Surge Protection: IEC 801-4
Section 3
OMEGA Installation, Operation, and Maintenance Manual 35
Page 36
Section 3 Specifications
Notes
36 OMEGA Installation, Operation, and Maintenance Manual
Page 37
Section 4 Using the Configuration Program
Section 4 Contents
Prerequisites...................................................39
Getting Started................................................40
Reading the Cellular Telephone Signal..........41
Programming a Telephone Number...............42
Changing the Cellular Telephone’s SID ........43
Changing the Login Password........................43
Exiting the Configuration Program................44
OMEGA Operation, and Maintenance Manual 37
Page 38
Section 4 Using the Configuration Program
OMEGA Operation, and Maintenance Manual 38
Page 39
4
Section 4
Using the Configuration Program
Introduction
OMEGA comes with a configuration software program that lets you:
Check the OMEGA’s cellular telephone receive signal
c
strength. Program a telephone number into OMEGA.
c
Change the System ID (SID) for the OMEGA’s cellular
c
telephone. Set or change the login password.
c
This chapter describes how to use the configuration software program to perform these tasks.
Prerequisites
Before you use the OMEGA configuration software program, you must:
Have a PC equipped with a Microsoft Windows operating
c
system or MS-DOS. Have a cable with a male DB9 connector on one end for
c
attaching to the OMEGA serial port; the connector on the other end attaches to a serial port on your computer.
Know the communications (COM) port used by your
c
computer’s serial port. Contact your local cellular service provider for OMEGA’s
c
cellular telephone phone number and SID number.
OMEGA Operation, and Maintenance Manual 39
Page 40
Section 4 Using the Configuration Program
Getting Started
To begin the OMEGA configuration process:
In your computer’s floppy drive, insert the floppy diskette
1.
containing the OMEGA configuration program. Then create a new folder on your computer’s hard drive and copy all of the files from the OMEGA configuration diskette to that folder.
NOTE:
Remember the name of the folder that contains the OMEGA configuration program. You will need to access this folder later in this procedure.
Connect a data cable with a male DB9 connector to OMEGA’s
2.
serial port (see Figure 1-1 on page 13). Connect the other end of the cable to your notebook
3.
computer’s serial port. Apply 115 VAC power to OMEGA (see “Powering-up
4.
OMEGA” on page 21). The green Exit to an MS-DOS window:
5.
If your computer is running Windows 95 or 98, click the
c
Start button on the taskbar and click
DOS
prompt
If your computer is running a different operating system,
c
.
Power
Programs
LED goes ON.
MS-
and
refer to the manual that came with the computer for instructions on getting to a DOS prompt.
Change to the directory (folder) where you copied the
6.
OMEGA configuration program file. For example, if you copied the files to a directory called OMEGA type the bold command in the following line at the MS-DOS prompt and press the Enter key:
C:\WINDOWS>
cvdm
Type
7.
CD\OMEGA
and press Enter. The OMEGA configuration
program prompts you for a COM port (see Figure 4-1).
40 OMEGA Installation, Operation, and Maintenance Manual
Page 41
Section 4
Using the Configuration Program
Figure 4-1. COM Port Prompt
8. Type the COM port number assigned to your computer’s serial
port (for example, 1) and press Enter. The following menu appears.
Figure 4-2. Main Menu
From this menu, you can:
Read the cellular telephone’s receive signal  see “Reading
c
the Cellular Telephone Signal,” below.
Program a telephone number into the OMEGA cellular
c
telephone  see “Programming a Telephone Number” on page
42.
Quit the program  see “Exiting the Configuration Program”
c
on page 44.
Reading the Cellular Telephone Signal
The OMEGA configuration program uses a bar graph as a visual indication of the cellular telephone’s receive signal strength. Using this feature, you can see whether the OMEGA’s cellular telephone is in an area where cellular reception is strong or weak.
1. With the Main Menu in Figure 4-2 displayed, press 1 at the
prompt. A bar graph similar to the one in Figure 4-3 appears, showing the receive signal strength of the OMEGA’s cellular telephone. The value shown to the left of the signal bar shows the receive signal level. A value of –80 or above indicate a strong signal. A value of –90 is normal. Values lower than -90 (such as –100 or –110) indicate a weak signal.
?
OMEGA Installation, Operation, and Maintenance Manual 41
Page 42
Section 4 Using the Configuration Program
Figure 4-3. Example of Signal Bar
2. To exit this mode and return to the Main Menu, press the Esc
key.
Programming a Telephone Number
Use the following procedure to program a telephone number into the OMEGA’s cellular telephone.
1. From the Main Menu in Figure 4-2, press 2. The message
Waiting for response…
program prompts you for a password (see Figure 4-4).
Figure 4-4. Password Prompt
appears, then the configuration
2. Type the password and press Enter. Initially, there is no
password, so press Enter without typing any characters. The message
Checking password…
appears followed by the
secondary menu (see Figure 4-5).
Figure 4-5. Secondary Menu
3. At the ? prompt, press 2. The configuration program prompts
you for a new telephone number.
4. Type the 10-digit telephone number (area code and telephone
number). You do not have to press Enter after typing. The message
Phone number updated!
Updating phone number…
Then the secondary menu reappears
appears followed by
with the new telephone number displayed.
42 OMEGA Installation, Operation, and Maintenance Manual
Page 43
Section 4
Using the Configuration Program
5. Verify that the telephone number displayed above the
secondary menu is the one you entered.
Entering the Cellular Telephone’s SID
To enter the System ID number for your local cellular service provider, use the following procedure.
1. If the secondary menu in Figure 4-4 is not displayed, perform
steps 1 and 2 under “Programming a Telephone Number” on page 42.
2. At the ? prompt, press 3. The configuration program prompts
you for a new SID (see Figure 4-6).
Figure 4-6. New SID Prompt
3. Type the 5-digit SID. You do not have to press Enter after
typing. The message
updated!
SID displayed.
4. Verify that the SID displayed above the secondary menu is the
one you entered.
Then the secondary menu reappears with the new
Updating SID
appears, followed by
SID
Changing the Login Password
By default, the OMEGA configuration program does not require you to type a password when you log in. If you desire, you can use the following procedure to password-protect the configuration.
1. If the secondary menu in Figure 4-4 is not displayed, perform
steps 1 and 2 under “Programming a Telephone Number” on page 42.
2. At the ? prompt, press 1. The configuration program prompts
you for a new password (see Figure 4-7).
Figure 4-7. New Password Prompt
OMEGA Installation, Operation, and Maintenance Manual 43
Page 44
Section 4 Using the Configuration Program
3. Type the new password. The password can contain up to eight
alpha and/or numeric characters. If you type fewer than eight characters, press Enter. The configuration program prompts you to re-enter the new password you typed.
NOTE:
NOTE:
For security purposes, each password character you type appears as an asterisk (*).
4. Re-enter the same password you typed in the previous step and
press Enter. The message followed by
Password updated
Updating password…
.
appears
After you change the password, you will need to specify it before you can log in to the OMEGA configuration program. To return to the default setting of no password, repeat this procedure but press the Enter key in steps 3 and 4 without typing any characters.
If the password you type in step 4 is different than the one you typed in step 4, the message
Password mismatch
appears and the new password does not take effect. If this happens, repeat this procedure, making sure to type the same characters in steps 3 and 4.
Exiting the Configuration Program
To exit the OMEGA configuration program:
1. From the secondary menu, press Q at the ? prompt. The
message
2. At the ? prompt, press Q again. You exit the OMEGA
configuration program and return to an MS-DOS prompt.
3. If your computer is running a Windows operating system, you
can close the MS-DOS window by typing Enter.
Please wait…
appears followed by the Main Menu.
exit
and pressing
44 OMEGA Installation, Operation, and Maintenance Manual
Page 45
Section 5 External Antenna Guidelines
Section 5 Contents
General Guidelines.........................................47
External Antenna Selection Criteria...............48
Types of External Antennas...........................50
Programming a Telephone Number...............51
Contact Information .......................................51
OMEGA Operation, and Maintenance Manual 45
Page 46
Section 5 External Antenna Guidelines
46 OMEGA Installation, Operation, and Maintenance Manual
Page 47
5
Section 5
External Antenna Guidelines
Introduction
This section provides guidelines about using an external antenna with OMEGA. If you will not be using an external antenna, you can skip this section
General Guidelines
The following guidelines provide general topics about using an external antenna with your OMEGA.
High Voltage Areas
To avoid any damage, serious injury, or possible death, never install an antenna near high-voltage power lines. Telenetics recommends that you provide lightning protection for all external antennas.
RF Signal
Antennas cannot amplify an radio-frequency signal. Rather, they are designed to concentrate the radiated signal in a specific pattern or focus it in a particular direction. The range of an antenna can be increased by concentrating or focussing the signal.
Gain
An antenna’s gain is one of its identifying characteristics. Terms such as amount of gain of an antenna is based on that of a true omni­directional antenna. This type of antenna radiates the transmitted signal in all directions. If the radiated power were visible, it would resemble a sphere encompassing the antenna.
An omni-directional antenna is described as having 3dB gain antenna has a greater range. This type of antenna is also referred to as omni-directional because the signal is transmitted in all directions. However, the signal is concentrated in a horizontal plane, so instead of a spherical “image”, its radiated power image resembles a disk. With this type of RF signal concentration, a 3­watt 3dB gain antenna has the equivalent range of a 6-watt unity gain antenna and is said to have 6 watts of Effective Radiated Power (E.R.P.).
unity gain, 3dB gain
, and
9dB gain
are common. The
unity gain
. A
OMEGA Installation, Operation, and Maintenance Manual 47
Page 48
Section 5 External Antenna Guidelines
NOTE:
Doubling the E.R.P. does not double the range of an antenna.
External Antenna Selection Criteria
The following sections identify the factors to consider when selecting the type and location of external antenna to use with your OMEGA unit.
Antenna Placement
The method and quality of the antenna installation impact the clarity and reliability of cellular signal reception and transmission. Always strive for optimal antenna placement.
Distance from the Antenna to the Closest Cell Site
Find out the locations of all nearby cell sites. This information will help you position the antenna for maximum performance. Contact the local cellular carrier to obtain this information.
Degrees of Down-tilt on the Cell Site Antenna Array
Contact the local cellular carrier to find out this figure. The greater the down-tilt, the closer your antenna should be to the cell site or the higher gain antenna you need.
Obstacles between the Antenna and Cell Site
Natural obstacles such as mountains, hills, and trees between the antenna and cell site can cause signal deterioration. In some instances, the signal can be blocked completely. To compensate for natural obstacles, move the antenna location, raise the antenna height, or use a higher gain antenna.
Man-made obstacles can also affect cellular performance. Check the path between the antenna and the cell site for tall buildings, water towers, and other construction. To compensate for man­made obstacles, move the antenna location, raise the antenna height, or use a higher gain antenna are ways.
48 OMEGA Installation, Operation, and Maintenance Manual
Page 49
Section 5
External Antenna Guidelines
Electrical Interference
Never locate an antenna near high voltage power lines. In addition, take into account any other sources of possible electrical interference such as AC power lines, radio-frequency generators, and other antennas.
Distance from the Antenna to OMEGA
Determine this distance by checking the signal strength. Start your check with the antenna located as close to the OMEGA unit as possible, using the shortest possible cable length. If you do not get a high-quality connection, try other locations. For example, you might get best results by attaching the antenna to the outside of a building, farther from the OMEGA unit, but with less obstructions between it and the cell site.
Height Above Ground Level of the Antenna
Always elevate the antenna as high as possible, so it has the clearest possible path to the cell site.
Cable for Connecting the Antenna to OMEGA
Lay the connecting cable as straight as possible without kinks, bends, or twists. If you need to keep the cable coiled, use as large a radius for the coil as possible.
Keep in mind that although the maximum distance between the OMEGA unit and the external antenna is 50 feet, the distance between the OMEGA unit and the meter/telephone equipment it serves can be over 1,000 feet. The OMEGA unit does not have to be near the meter/telephone equipment to work. This factor gives you more flexibility in selecting the best antenna location.
When the installation location is within the range of the cell site, a unity gain or 3dB gain antenna is usually sufficient to produce a good quality cellular connection. If the antenna installation is on the fringe of the cell site’s range or outside that range, consider using a high gain directional antenna to achieve an acceptable connection.
If you cannot find an antenna location that results in a good quality connection, you might have to relocate the entire installation. Before doing so, however, try to access a different cell site through the use of a high-gain directional antenna. Even though the new
OMEGA Installation, Operation, and Maintenance Manual 49
Page 50
Section 5 External Antenna Guidelines
cell site might be farther away, the fact that the signal is coming from a different direction might avoid natural or man-made obstacles that blocked the signal from reaching the previous antenna location.
Types of External Antennas
The following sections describe the various external antennas that can be used with OMEGA.
Directional Antenna
A directional antenna is usually best for a fixed installation. The signal from this type of antenna is focussed in one direction. Directional antennas can be designed to have different beam widths –– wide, medium, or narrow. The narrower the beam width, the higher the antenna’s gain.
Directional antennas must be pointed directly at the cell site. We recommend you use directional antennas designed to provide the maximum E.R.P. allowed by FCC regulations and EIA standards. Contact the cellular carrier in your area to determine the exact location of the nearest cell site.
To install a directional antenna:
Find the location of the nearest cell site that services your area.
c
Attach the antenna to the appropriate connector on the
c
OMEGA unit, making sure the connection is secure.
Point the antenna toward the cell site.
c
Make sure the bars on the antenna are positioned vertically.
c
Make sure that the antenna perimeter is clear of objects,
c
especially metal ones, that might interfere with the signal transmission and reception.
Elevated Feed 3dB Gain Antenna
Elevated feed antennas are designed to handle most cellular installations. There are a number of different ways to mount the antenna that will result in adequate signal strength for data applications in most area. Note that this type of antenna does not require a ground plane.
50 OMEGA Installation, Operation, and Maintenance Manual
Page 51
Section 5
External Antenna Guidelines
Follow these guidelines when you install the antenna:
Mount the antenna as high as possible.
c
Try to mount the antenna with a direct line of “vision” to the
c
nearest cellular site.
Place the antenna vertically on a solid surface.
c
Be sure that the antenna perimeter is clear of objects, especially
c
metal ones, that might interfere with the signal transmission and reception.
Determining the Best External Antenna Location
Regardless of which type of external antenna you use, reception and propagation patterns vary with the location. To achieve the best results, try different locations. Even if a location appears adequate, you should try other locations in case you find a better one. Once you find the best location, permanently mount the antenna there.
Use the OMEGA configuration application to evaluate the cellular telephone’s receive line signal strength and ascertain the best external antenna location. When the signal strength is –90 or higher, you have achieved a minimum acceptable cellular signal.
Contact Information
If you need technical assistance or information about various antenna products, contact Telenetics at the following number: (949) 455-4000.
OMEGA Installation, Operation, and Maintenance Manual 51
Page 52
Section 5 External Antenna Guidelines
Notes
52 OMEGA Installation, Operation, and Maintenance Manual
Page 53
Appendix A 8-Port Expansion Module Option
Appendix A Contents
Package Contents ...................................55
Field Installation......................................55
Testing the Module Ports ........................58
Connecting Endpoint Devices.................58
Specifying a Default Port........................60
Anti-streaming.........................................61
Command Summary................................62
OMEGA Operation, and Maintenance Manual 53
Page 54
Appendix A 8-Port Expansion Module Option
54 OMEGA Installation, Operation, and Maintenance Manual
Page 55
A
Appendix A
8-Port Expansion Module Option
Introduction
An optional eight-port expansion module, Model OM-MP8-100, is available for OMEGA. This expansion module allow up to eight endpoint devices (such as meters, relays, and controllers) with internal modems to connect to a single OMEGA Model OM-AMPS-100 Cellular Interface Cabinet.
This appendix describes how to install the expansion module. For more information about the expansion module, please contact Telenetics.
Package Contents
The 8-Port Expansion Module package contains the following items:
One OMEGA 8-Port Expansion Module
c
(Model Number. OM-MP8-100)
Two plastic card guides
c
One short RJ-11 to RJ-11 cable
c
A diskette containing configuration software
c
A Quick Start Guide
c
If any of these items are missing or damaged, please contact Telenetics immediately.
Field Installation
The eight-port expansion module is designed for simple installation in the field. Use the following procedure to install the module.
1.
Set the Power Battery switch to the OFF position and lift the AC fuse connector (see Figure 1-1 on page 13).
2.
Orient the two plastic card guides so their slots face inward toward each other. Snap the guides into place in the holes in the OMEGA baseboard.
OMEGA Installation, Operation, and Maintenance Manual 55
Page 56
Appendix A 8-Port Expansion Module Option
3. Insert the cable clip into the round hole next to the relays
labeled K2 and K3 on the component side of the Module. Use this cable clip to route and arrange cables within the OMEGA unit.
4. Hold the Module vertically above the card guides, so its 8 RJ-
11 jacks are at the top and facing toward the inside of OMEGA.
5. Insert the Module into the card guide slots and slide it down
until the male connector engages fully into the female connector on the OMEGA baseboard (see Figure A-1). This installation can only be made one way. If you are not successful with your first try, turn around the Module and try again.
Firgure A-1. Sliding the Module into the Card Guides
56 OMEGA Installation, Operation, and Maintenance Manual
Page 57
Appendix A
8-Port Expansion Module Option
6. Press down the Module gently until it snaps securely into the
card guide connectors (one on each card guide).
7. Insert one end of the supplied short cable into the RJ-11 jack
on the lower-left side of the Module. Insert the other end into the OMEGA unit’s RJ-11 jack on the unit’s baseboard (see Figure A-2).
Figure A-2. Connecting the RJ-11 Jacks
8. Plug in all the RJ-11 cables from the external devices (see 5,
“Connecting Endpoint Devices” on page 58).
9. Set the OMEGA Power Battery switch to the ON position and
close the AC fuse connector. Verify that each LED above the 8 RJ-11 jacks on the Module turns green. This color indicates that the meter ports are onhook and ready for operation.
OMEGA Installation, Operation, and Maintenance Manual 57
Page 58
Appendix A 8-Port Expansion Module Option
Testing the Module Ports
After you install the Module, test each port on the Module:
Connect a handset to one of the RJ-11 jacks on the
1.
Module.
Lift the handset and listen for a dial tone.
2.
Verify that the LED above the jack remains green, while
3.
the LEDs for the other 7 ports turn red.
Repeat this procedure for the remaining Module ports.
4.
Connecting Endpoint Devices
Connect an endpoint device to the Module’s RJ-11 jack labeled (which corresponds to port 1). Connect the remaining endpoint devices to any of the other RJ-11 jacks. A remote host can communicate with one endpoint device at a time using either of the following methods.
In both cases, the connection is maintained until the host or meter ends it. When a host connects to an endpoint device, the LED above the port being called remains green. The LEDs for all other ports turn red to show that they are “locked out” until the host goes on-hook. You can also connect a phone to the OMEGA’s RJ-11 jack to originate and receive calls as you would normally.
The host can communicate with an endpoint device in two ways: using the Time Delay method or the Second Dial Tone method.
J1
Time Delay Method (Automatic Connection)
With this method, the host computer calls OMEGA and waits for a connection. When connected, the host sends a DTMF digit that corresponds to a number from 1 to 8 on a touch-tone telephone or via a modem. This number corresponds to the port with which the host wants to communicate. For example, sending the DTMF digit
4
corresponds to port 4.
When OMEGA is configured for the time delay method, the host issues the following dial string:
ATDT<
In this string:
c
58 OMEGA Installation, Operation, and Maintenance Manual
phone number
<
phone number
code, if required).
>,,,<
>
is the OMEGA phone number (and area
port number
<Enter>
>
Page 59
8-Port Expansion Module Option
Each comma represents a 2-second pause.
c
Appendix A
<
c
port number
> is the port number with which the host
wants to communicate.
<Enter>
c
Example: ATDT 19495552468,,,4
is the pressing of the Enter key on your computer.
<Enter>
In this example, OMEGA dials 1 949 555-2468, waits 6 seconds to allow a connection, and connects the line to port
4.
Second Dial Tone Method (Manual Connection)
With this method, the host computer calls OMEGA and waits for a “second” dial tone from OMEGA. The second dial tone signals the host to enter the DTMF tone that corresponds to an OMEGA port.
To enable this method, connect a laptop computer to OMEGA’s DB-9 connector, start a terminal-emulation program such as HyperTerminal, set up the program to use the parameters on page 62, and send the following command from the program:
\PR=1
<Enter>
.
When OMEGA is configured for the second dial tone method, the host issues the following dial string:
ATDT<
phone number
>W,,<
port number
<Enter>
>
In this string:
<
phone number
> is the OMEGA phone number (and area
code, if required).
W indicates that the host is to wait for the second dial tone.
Each comma represents a 2-second pause.
<
port number
> is the port number with which the host
wants to communicate.
<Enter>
is the pressing of the Enter key on your computer.
Example: ATDT 19495552468W,,6 <Enter> To switch from the second dial tone method to the time delay
method, use a laptop computer connected to OMEGA’s DB-9 connector to send the following command from a terminal­emulation program: \PR=0
<Enter>
OMEGA Installation, Operation, and Maintenance Manual 59
Page 60
Appendix A 8-Port Expansion Module Option
Specifying a Default Port
There may be times when you want to specify a default OMEGA port. Specifying a default port enables the host to automatically contact the same OMEGA port with each call. This feature is convenient, for example, if you want to connect to a telephone set at the OMEGA site.
To enable a default port, connect a laptop computer to OMEGA’s DB-9 connector, start a terminal-emulation program such as HyperTerminal, set up the program to use the parameters on page 62, and send the following command from the program:
\PD=<
In this command, <port number> is a port number from 1 to 8 you want to specify as the default port.
Example: Specifying OMEGA port 4 as the default port:
\PD=4
port number
<Enter>
<Enter>
>
When OMEGA is configured with a default port, the host can dial OMEGA using the dial string for either the Time Delay method or the Second Dial Tone method; however, the port number must be omitted from the string.
Time delay example: ATDT 19495552468,,,
Second dial tone example: ATDT19495552468W,,
When OMEGA is configured with a default port and receives a dial string with no port number, it waits 10 seconds and then automatically routes the call to the default port specified by the command:
To disable a default port, use a laptop computer connected to OMEGA’s DB-9 connector to send the following command from a terminal-emulation program: \PD=0
\PD=<
port number
<Enter>
>
<Enter>
<Enter>
<Enter>
60 OMEGA Installation, Operation, and Maintenance Manual
Page 61
Appendix A
8-Port Expansion Module Option
Anti-streaming
OMEGA provides an anti-streaming feature that deactivates OMEGA ports that are off-hook but have not dialed out for 12 seconds. Anti streaming deactivates the ports that are off-hook, without affecting any of the OMEGA ports that are on-hook. This enables the on-hook OMEGA ports to function normally. The deactivated ports are reactivated when any of the following actions occurs:
An incoming call selects that port using a DTMF tone.
c
OMEGA is powered-up locally.
c
The OMEGA Reset button is used to reset the unit.
c
OMEGA is reconfigured.
c
Note:
If a port stays on-hook after a bad train and remote disconnect, the port is deactivated, which places the OMEGA modem on-hook. After two minutes, the port is reactivated automatically if the modem is still on-hook.
To enable anti streaming, connect a laptop computer to OMEGA’s DB-9 connector, start a terminal-emulation program such as HyperTerminal, set up the program to use the parameters on page 62, and send the following command from the program:
\PS=1
<Enter>
To disable anti streaming, connect a laptop computer to OMEGA’s DB-9 connector and send the following command from a terminal­emulation program: \PS=0
<Enter>
OMEGA Installation, Operation, and Maintenance Manual 61
Page 62
Appendix A 8-Port Expansion Module Option
Command Summary
To… Do the Following…
Prepare for terminal-emulation mode at a laptop computer.
Specify default port number.
Disable default port operation.
Enable second dial tone method. Disable second dial tone method,
returning OMEGA to the time delay method.
Enable anti-streaming.
<
port number
>
as the
Start a terminal-emulation program such as HyperTerminal and specify the following parameters: Data rate: 9600 bps Data bits: 8 Parity bit: None Stop bit: 1
Type
<Enter>
Type
Type
Type
Type
\PD=<
\PD=0 and press
\PR=1 and press \PR=0 and press
\PS=1 and press
port number
> and press
<Enter>
<Enter> <Enter>
<Enter>
Disable anti-streaming.
62 OMEGA Installation, Operation, and Maintenance Manual
Type
\PS=0 and press
<Enter>
Page 63
Appendix B Warranty & Compliances
Appendix B Contents
Warranty and RMA Statement................65
FCC Statement ........................................67
Comments About This Manual...............68
OMEGA Operation, and Maintenance Manual 63
Page 64
Appendix B Warranty & Compliances
64 OMEGA Installation, Operation, and Maintenance Manual
Page 65
B
Appendix B
Warranty & Compliances
This appendix provides warranty and RMA information, along with FCC compliance information, and steps to follow if you have comments about or corrections to this manual.
Warranty and RMA Statement
Subject to the conditions and procedures set forth below and for one year after the date of shipment by Telenetics, Telenetics will repair or replace, at Telenetics' option, such Telenetics products or parts thereof or software which, on inspection by Telenetics, are found to be covered by the limited warranties set forth below. If you think there is a problem or defect with your Telenetics internetworking product or software:
c
Contact Telenetics' Technical Support Department between 8:00 a.m. and 5:00 p.m., Pacific Time at (949) 455-4000 or via fax at (949) 455-4010. The Telenetics Technical Support Representative will discuss your problem to confirm the defect.
please leave a voicemail. A Technical Support Representative will respond to you the next business day.
c
If warranty or return service is needed, you will receive a Return Material Authorization (RMA) number. At no time should Telenetics products or software be sent back without a valid RMA number. Telenetics accepts no responsibility for unauthorized returns.
After business hours,
c
You agree to pay for shipping to Telenetics. If the product is under warranty, Telenetics will pay for shipping the repaired or replacement products to you. All Telenetics-paid shipments to customers will be by ground transportation. Any other freight arrangements will be at customer expense.
c
Telenetics shall not be liable for any damage caused to the product in transit. You acknowledge and agree that you will bear all risk of loss or damage to the product while in transit.
Send return shipments to: Telenetics Corporation 25111 Arctic Ocean Lake Forest, California 92630 ATTN: RMA # ______________________
c
Pack products securely, to prevent damage in transit. Be sure the RMA number is clearly visible on the outside of the return shipping carton.
c
Returned Telenetics products must include all other components from the original package, including the hardware, any cables, connectors, and user manual(s) unless otherwise stipulated by Telenetics.
c
Enclose a copy of the original purchaser’s proof of purchase, if needed to support warranty claim. (See details in LIMITATIONS on the next page.)
After inspecting the failed unit, Telenetics will repair or replace defective parts or components. If upon inspection by Telenetics, a unit returned under warranty is deemed to be damaged or out of warranty for any reason, (see LIMITATIONS section on the next page), Telenetics will contact the customer with a price for the repair or replacement unit. Upon receipt of payment (wire transfer, certified check, credit card, etc.) for the replacement unit plus outbound shipping fees, Telenetics will send a new refurbished unit to the customer. Customers who do not accept the repair offer may receive their failed equipment back by prepaying the return freight cost.
In selected circumstances, determined by Telenetics in its sole judgment, Telenetics will ship advance replacement for defective products within two business days of the approved RMA request
provided that the product is in stock
OMEGA Installation, Operation, and Maintenance Manual 65
. All Telenetics-paid shipments to customers will be by
Page 66
Appendix B Warranty & Compliances
ground transportation. Any other freight arrangements will be at customer expense. Customers who receive this advance-replacement service shall, prior to the shipment of the advanced shipment product,
c
Provide a credit card number or hard copy purchase order as collateral for the loaned product.
c
Sign an RMA agreement outlining the terms and conditions of the exchange.
c
Agree to return the defective product to Telenetics within five (5) business days of receipt of the advance replacement unit.
If, upon inspection by Telenetics, a unit returned under warranty is found to be defect free, Telenetics reserves the right to charge the customer a $500 test fee.
TELENETICS' SOLE AND EXCLUSIVE OBLIGATION, AND YOUR SOLE AND EXCLUSIVE REMEDY, UNDER THIS LIMITED WARRANTY SHALL BE THE REPAIR OR REPLACEMENT OF THE APPLICABLE TELENETICS PRODUCT OR SOFTWARE IN ACCORDANCE WITH THE TERMS SET FORTH HEREIN.
LIMITATIONS
As the original purchaser, you receive these warranties from Telenetics Corporation, subject to the terms and limitations set forth below.
Telenetics warrants that your Telenetics products will be free from defects in material and workmanship and will perform in compliance with the operator’s guide(s) accompanying the products for a period of one year.
Telenetics does not cover or accept liability for any injury, damage or failure caused by misuse, misapplication, abuse, acts of nature, accidents (e.g., dropping the Telenetics products or software diskettes), electrical mishaps, causes beyond our control, or claims by other than the original purchaser.
Telenetics will not honor, and will consider this limited warranty voided, if, in Telenetics' reasonable judgment, there has been any (1) tampering with the Telenetics product's external label or serial number, (2) attempt to open the Telenetics product's case, (3) attempted or actual repair by anyone other than an authorized Telenetics technician, or (4) installation or use with any power supply component(s) other than the original Telenetics power supply components provided in the product package, (5) installation or use with any cables or antenna(s) other than original Telenetics products, (6) Installation or use in environmental conditions that are outside Telenetics’ published environmental specifications (including but not limited to temperature range, humidity, cable lengths, proximity to other devices, etc.).
Warranty is given for twelve (12) months from the date of product shipment from Telenetics. Telenetics will honor warranty twelve months from the original end user’s shipment date, upon receiving proof of purchase. “Proof of purchase” is a copy of the original sales transaction, showing complete name and address of seller, complete name and address of purchaser, date of purchase, product model number and serial number(s).
DISCLAIMER OF WARRANTIES
EXCEPT AS EXPRESSLY SET FORTH HEREIN, TELENETICS HEREBY EXPRESSLY DISCLAIMS ANY AND ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION THE IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR USE.
WAIVER OF CONSEQUENTIAL DAMAGES
TELENETICS HEREBY DISCLAIMS ANY AND ALL SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES (INCLUDING WITHOUT LIMITATION, LOST PROFITS, LOSS OF OR DAMAGE TO ANY OTHER COMPUTER EQUIPMENT OR RELATED DATA) WHICH MAY RESULT FROM BREACH OF ANY WARRANTY, OR ARISING OUT OF THE USE OR INABILITY TO USE ANY TELENETICS PRODUCT OR SOFTWARE, EVEN IF TELENETICS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
66 OMEGA Installation, Operation, and Maintenance Manual
Page 67
Appendix B
Warranty & Compliances
FCC Statement
The following sections contain FCC compliance information about your OMEGA unit.
FCC Interference Statement
This equipment has been tested and found to comply with the limits for a Class A Digital Device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against interference if installed and operated properly in a commercial environment. This equipment generates, uses and can radiate radio frequency energy. If not properly installed and used in accordance with the instructions in this manual, harmful interference can be caused to radio communications. Operation of this equipment in a residential area is likely to cause interference in which case the user will be required to correct the interference at their expense.
FCC Part 15 Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
c
Reorient or relocate the receiving antenna.
c
Increase the separation between the equipment and the receiver.
c
Connect the equipment to an outlet on a circuit other than the one to which the receiver is connected.
c
Consult the dealer or an experienced radio/TV technician for help.
If none of these actions resolves the problem, consult your distributor or an experienced radio/television technician for additional suggestions.
Additionally, Section 15.838, paragraph d), of the FCC Rules and Regulations states: “Where special accessories, such as shielded cables, are required in order to meet FCC regulations, shielded cables must be used with this equipment. Operation with non­approved equipment or unshielded cables is likely to result in interference to radio and TV reception. The user is cautioned that changes and modifications to this equipment without the approval of the manufacturer could void the user’s authority to operate this equipment.
OMEGA Installation, Operation, and Maintenance Manual 67
Page 68
Appendix B Warranty & Compliances
Comments About This Manual
Telenetics invites all customers to communicate with us about any question or comment related to this manual. Just fax, phone, or mail any question or comment to us. Your suggestions help us improve the products we deliver.
Telenetics Corporation. 25111 Arctic Ocean Lake Forest, California 92630 Tel: (949) 455-4000 Fax: (949) 455-4010
68 OMEGA Installation, Operation, and Maintenance Manual
Page 69
INDEX
A
Activating cellular transceiver, 22 Agency compliance, 35 Anti-streaming, 61 Avoiding hazards, 15
Exiting the configuration program, 44 External antenna
best location, 51 directional, 50 elevated feed, 50 general guidelines, 47 selection criteria, 48 types, 50
B
Battery operation, 32 Best external antenna location, 51
C
Call answer testing, 23 Cellular telephone SID
changing, 43 cellular telephone signal, 41 Cellular transceiver
activating, 22 Cellular transceiver interface, 32 Cellular transceiver unit, 22 Changing
cellular telephone SID, 43
login password, 43 Checking
antenna, 28
battery voltage, 28
main power supply, 27 Comments about manual, 68 Compliance, 35 Connecting endpoint devices, 58 Connecting the input voltage source, 18 Connectors, 34
D
Default port, specifying, 60 Directional external antennas, 50 Drilling conduit holes, 16 Drilling mounting holes, 16
E
Eight-port expansion module
field installation, 55
operation, 58
overview, 55 Elevated feed external antennas, 50 Environmental specifications, 34
F
FCC
Interference Statement, 67 Part 15 Statement, 67
Finding a suitable location, 14
H
Hardware features, 13
I
Input voltage source, 18 Installation
eight-port expansion module, 55 OMEGA, 15
Interfaces
cellular transceiver, 32 modem, 31
L
LED indicators, 33 Locating an external antenna, 51 Login password
changing, 43
M
Manual comments, 68 Mechanical specifications, 34 Modem interface, 31 Mounting, 16
O
OMEGA
avoiding hazards, 15 call answer testing, 23 drilling conduit holes, 16 drilling mounting holes, 16
OMEGA Operation, and Maintenance Manual 69
Page 70
INDEX
finding a suitable location, 14
hardware features, 13
input voltage source connection, 18
installation, 15
mounting instructions, 16
operation, 22
power-up, 21
specifications, 62 OMEGA configuration program
changing the cellular telephone SID, 43
changing the login password, 43
exiting, 44
getting started, 40
prerequisites, 39
programming a telephone number, 42
reading the cellular telephone signal, 41 Operation, 22, 31
P
Password
changing, 43 Power supply, 33 Power-up, 21 Prerequisites for OMEGA configuration program, 39 Programming a telephone number, 42
R
Reading the cellular telephone signal, 41 RMA, 65
SID
changing, 43 Signal for cellular telephone, 41 Specifications, 31, 39, 47, 62
agency compliance, 35
battery operation, 32
cellular transceiver interface, 32
connectors, 34
environmental, 34
LED indicators, 33
mechanical, 34
modem interface, 31
operation, 31
power supply, 33
switches, 33 Specifying a default port, 60 Switches, 33
T
Telephone number
programming, 42 Time delay method, 58 Troubleshooting, 27
antenna, 28
battery voltage, 28
main power supply, 27
V
Verifying the cellular transceiver unit, 22
S
Second dial tone method, 59 Selecting an external antenna, 48
W
Warranty, 65
70 OMEGA Installation, Operation, and Maintenance Manual
Loading...