Telenetics MIU/PowerPort 202T, MIU/PowerPort 2.4, MIU/PowerPort 9.6, MIU/PowerPort 9.6L, MIU/PowerPort 14.4 Specifications

...
Page 1
Modems
Modems
MIU/PowerPort can be powered by delivering +5VDC (regulated) through pin 10 of the DB25. An optional 7-16VDC version is also available. Alternatively, an external jack allows the MIU/PowerPort to be powered from a wall transformer or other low voltage AC or DC power source.
When not on line, the dial-up MIU/PowerPort modems automatically go into a power down mode and consume only a few microamps while inactive.
The MIU/PowerPort operates over dial and 2-wire/4-wire leased lines at full or half duplex as appropriate with various modulations, including:
• V.22bis (2400bps)
• V.32bis (14400bps)
The MUI/PowerPort is fully Hayes™ AT command set compatible with programmable S-registers.
All models will operate in temperatures from -40°C to +85°C and are surge protected on the analog line up to 5kV.
MIU/PowerPort
LOW VOLTAGE, DC POWERED MODEMS
1.2, 2.4, 9.6 & 14.4 kbps
Bell 202T, V.22bis, V.32bisDial-Up and Leased LinesPowered from 5-24VDC through the Data Port
or an External Jack
Automatic “Power Down” when inactive-40°C to +85°C Operating Temp.Hayes AT CompatibleIdeal for Meters, Relays, RTUs, Controllers, etc.
The MIU/PowerPort is an industrial grade modem that is designed to be powered directly through the RS232 (DB25) data interface port.
Page 2
Technical Specifications
MIU/PowerPort
202T
MIU/PowerPort
2.4
MIU/PowerPort
9.6 & 9.6L
MIU/PowerPort
14.4 & 14.4L
Modem Line Speeds: Asynchronous
DTE Rates: above modem line speeds (ie; with data compression)
Standards:
Dial Up
2 / 4-W Leased Line
Configuration
Error Correction/ Data Compression
Power Requirement
0 - 1200bps
Bell 202T
No
1
Yes
Dip Switch
None None
2400, 1200,
300bps
V.22bis, V.22
Bell 212A
Bell 103
Yes
No
2400, 1200,
300bps
19200, 9600,
4800bps
V.22bis, V.22
Bell 212A
Bell 103
V.32bis, V.32 V.22bis, V.22
Bell 212A, Bell 103
Yes (Model 9.6)
2
Yes (Model 9.6L
)
Hayes™ Extended AT Command Set
MNP 2, 4, 5 & 10
V.42, V.42bis
14400, 9600, 4800, 2400, 1200, 300bps
Yes (Model 14.4)
Yes (Model 14.4L2)
+5VDC ±5% in through Pin 10 on the DB25 Data Port
(Option: 7-16VDC in through Pin 10 on the DB25 Data Port. Please Specify -PO.)
The modem can also be powered from an
optional 120VAC wall transformer model WT/120-9VA.
57.6, 38.4,
19.2kbps
25111 Arctic Ocean Drive Lake Forest, CA 92630 tel. 949.455.4000 fax. 949.455.4010 www.telenetics.com
64mA @ +5VDC 35mA @ 12VDC
Current Consumption
128mA @ +5VDC
71mA @ 12VDC
Dial up modems can be factory set to automatically fall into “Power Down” mode after 45 seconds of
inactivity. Draws <0.2mA in power down mode. Powers back up on receipt of DTR signal or incoming call.
Digital Port
Analog Port
Surge Protection (Analog Port)
Environment
3.75kVac 5kVac 5kVac 3.75kVac
-40°C to +85°C, 0 to 95% humidity (non-condensing)
Case Size
Certifications
Important Notes regarding leased line operation: multipoint applications.
2
The standard 9.6L and 14.4L models are 4-wire, full or half duplex, point-to-point only. 2-wire,
full duplex, point-to-point available on special order.
100mA @ +5VDC
56mA @ 12VDC
219mA @ +5VDC 123mA @ 12VDC
RS232 with DB25 Female Connector
RJ-11 Modular Jack
5-3/8" x 4" x 1-3/8"
FCC Part 68 Class A; Industry Canada Certified
1
Bell202T is half or full duplex, suitable for point-to-point and
Document #0004 0700
Telenetics is a registered trademark of Telenetics Corporation. All other trademarks are the property
of their respective holders. ©2000 Telenetics Corporation. All rights reserved.