TELEMED UAB ClarUs, ClarUs EXT-1M User Manual

TELEMED ClarUs User Guide, REV 4.0 2013.12.04
1
ClarUs
ClarUs EXT-1M
Ultrasound Diagnostic System
TELEMED ClarUs User Guide, REV 4.0 2013.12.04
2
Manufactured by TELEMED UAB Dariaus ir Gireno str. 42 Vilnius LT-02189 Lithuania Telephones: (+370-5) 2106272 (+370-5) 2106273 Fax: (+370-5) 2306733 Internet: http://www.telemed.lt E-Mail: info@telemed.lt
NOTE: Non-TELEMED product names may be trademarks or registered trademarks of their respective owners.
TELEMED ClarUs User Guide, REV 4.0 2013.12.04
3
1. INTRODUCTION 5
1.1. About the system / Intended use 5
1.2. Delivery set 7
1.3. About the system software 7
1.4. Technical Specification 7
2. SAFETY 12
2.1. Electrical safety 12
2.2. Equipment protection 13
2.3. Biological safety 13
2.4. Ultrasound exposure and ALARA principle 14
2.5. Cyber security 15
2.6. Accuracy Measures 15
3. LABELING 17
4. SYSTEM OVERVIEW 18
4.1. Principle of operation 18
4.2. Components & Modifications 18
4.2.1. Basic unit/Beamformer 18
4.2.2. Probe Unit 18
4.2.3 ClarUs 19
4.2.4 ClarUs EXT-1M 19
4.3. Connection and Indication ClarUs 20
4.4. Peripherals/Compatibility 22
5. INSTALLATION WARNINGS 23
5.1. Getting started with ClarUs 24
5.2. Status Indicator 24
5.3. Ultrasound Scanner Monitor utillity 24
5.4. Windows configuring 26
6. TROUBLESHOOTING 27
6.1. FAQ 27
6.2. Fuses locations (ClarUs) 27
6.3. Contact with technical support service 28
7. WARRANTY AND SERVICE INFORMATION 29
7.1. Warranty 29
7.2. Warranty Shipments and Returns 29
7.3. Service Contract 29
8. MAINTENANCE 30
8.1. General cleaning 30
8.2. Inspecting the System 30
8.3. Probe maintenance and disinfection 30
8.3.1 Chemicals that Damage Transducers: 31
8.3.2 Recommended Procedures for Probe Processing 31
TELEMED ClarUs User Guide, REV 4.0 2013.12.04
4
8.3.3 General Cleansing for Transducers Used in Non-Invasive Procedures ....... 31
8.3.4 Cleansing and Disinfection of Transducers Used in Endocavity Procedures 32
8.4. System accuracy / performance verification 32
9. TRANSPORTATION, STORAGE AND UTILIZATION 33
9.1. Transportation and storage 33
9.2. Utilization 33
10. ............ DECLARATION OF CONFORMITY 34
APPENDIX
1.Guidelines for the safe use of diagnostic ultrasound
2.Vigilance system
3. Returned product form
TELEMED ClarUs User Guide, REV 4.0 2013.12.04
5
1. INTRODUCTION
CAUTION:
United States federal law restricts this device to be used by, or on the order of, a licensed physician.
Dear customer, Our ClarUs system is intended for multipurpose ultrasound examinations, based on electronic linear and convex scanning.
It is an ideal budget solution for hospitals, specialized diagnostic centers and
public and private clinics.
Our new class of PC-based compact ultrasound scanners now features:
beamformer with multi-frequency probes support; Scan-converter free architecture; Industry standard tZIF-260 (Zero Insertion Force) probe connector; Digitally controlled acoustic power; Light weight, true mobility, flexible architecture.
Here in the User Guide you can find information about ClarUs and safety and
maintenance information.
Echo Wave II Software Operation Manual contains a description of the
controls.
1.1. About the system / Intended use
ClarUs system is intended to be used for applications in fetal, abdominal,
small organ (thyroid and breast), cardiac, peripheral vascular, musculo-skeletal (conventional) and needle guidance. It is possible to provide diagnostic information outside of an imaging lab, including at the bedside systems, for navigated medical applications and in operating rooms/critical care units.
ClarUs ultrasound systems provide many different scanning technologies: B, B+B, 4B, B+M, M, CFM, PDI, DPDI, PWD, B+PWD (Duplex), B+CFM/PDI/DPDI+PWD (Triplex), HPRF, automatic image optimization,etc. Echo images can be either full size or zoomed.
Unlike ordinary ultrasound devices, this scanner is based on modern digital technologies. PC application enables many powerful innovative features such as:
user friendly, easy-to-use intuitive graphic user interface; echo image storage on hard disk or other devices; storage of a sequence of full size echo images (cineloop) with the opportunity
to save it in video file format;
image and cineloop file formats enables using other applications for viewing
stored data;
using a variety of peripheral devices; direct echo image and video e-mail sending with one click.
A variety of available ultrasound probes provides many different applications for examinations in therapy, obstetrics, gynecology, urology, pediatrics, oncology and other areas.
TELEMED ClarUs User Guide, REV 4.0 2013.12.04
6
Common view of ClarUs shown below.
Figure 1
Common view of ClarUs EXT-1M shown below.
Figure 2
TELEMED ClarUs User Guide, REV 4.0 2013.12.04
7
1.2. Delivery set
ClarUs
ClarUs EXT-1M
Basic Unit ●
Beamformer ●
Operation manual
User guide ● ●
Software and manuals (CD-ROM)
Power Cable ●
Standard USB cable
Power supply (medical)
Windows OS installation CD
MacBook Pro manual
Mac OS X Install DVD
Application Install DVD
Ultrasound probe
Types and quantity defined by customer
1.3. About the system software
Your diagnostic system contains Echo Wave II software to control its operation. TELEMED provides the latest Echo Wave II software version and drivers package together with your system. In the software the unique technologies making the intellectual property of TELEMED company are used. Latest software versions can be downloaded directly on the Internet from http://www.telemed.lt .
1.4. Technical Specification
Table 1 contains technical specifications of ClarUs: Table 1
IMAGING MODES
B B+B 4B B+M M
Color Doppler (CFM) Power Doppler (PDI) Directional Power Doppler (DPDI) Pulse Wave Doppler (PWD) B+PWD (Duplex) B+CFM/PDI/DPDI+PWD (Triplex)
ULTRASOUND IMAGING
TELEMED ClarUs User Guide, REV 4.0 2013.12.04
8
ultrasound image size: automatically
adjustable to screen resolution
gray scale: 256 color scale: 256 full motion and full size real-time
ultrasound imaging, up to 120 fps (depends on selected scan depth, scan angle, focus mode, High Line Density setting, computer speed)
cineloop recording/play: several
thousands frames (depends on computer memory size and scan mode)
zoom mode: from 60% to 600% in all
modes (Scan, Freeze, B, B+B, 4B, Doppler modes, M-zoom, cineloop and etc)
viewing area variable for frame rate
maximizing: 6 steps
"FREEZE" mode
SCANNING METHOD
Electronic linear Electronic convex Electronic micro-convex
COLOR DOPPLER
PRF variable: 0.5-9 kHz wall filter settings: 3 steps
(5%, %10%, 15% PRF)
gain control: 50 dB angle steering for linear probes: ±10° real-time spatial filter: 3 values CFM palette: 10 maps
B/Color priority control color threshold control CFM baseline control Doppler frequency selection:
2 frequencies / each probe
color frame averaging: 8 values
PULSED WAVE DOPPLER
PRF variable:
0.3-10 kHz
wall filter settings:
16 steps (2.5%-20% PRF)
gain control: 50 dB angle steering for linear probes: ±10°
single click auto adjustment:
baseline, measurements, invert
stereo sound: volume control PWD palette: 12 maps Doppler frequency selection:
2 frequencies / each probe
DEPTH SELECTION
2 – 30 cm (depth range depends on probe type and scanner model)
PROBES
probes:
o from 2 MHz to 12 MHz o Multi-frequency
Automatic probe recognition
FOCUSING
Digital transmit focusing
Yes
Multi focus mode
Transmit/receive focusing, max 4 points Programmable focus area presets
Dynamic focus mode
Transmit variable focus, 8 points Dynamic receive focus, 8 zones
SIGNAL PROCESSING
TELEMED ClarUs User Guide, REV 4.0 2013.12.04
9
High Line Density scan mode for better resolution TGC Control, 5 sliders 40 dB dynamic range: 120 dB, 8 values overall gain control M - mode sweep speed control acoustic power control variable frame averaging brightness, contrast advanced gamma control: 8 fixed curves, 8 user defined (custom) scan direction, rotation, up-down controls negative / positive control bi-linear interpolation echo enhancement control noise rejection function speckle reduction function (optional)
FUNCTIONS
General Measurements and Calculations
Mouse / trackball / keyboard operation of multiple calipers B-mode: Distance / Length / Area / Circumference /
Volume / Angle / Stenosis % / A/B Ratio
M-mode: Distance / Time / Velocity / Heart Rate /
Stenosis % / A/B Ratio
Human Measurements and Calculations Packages
General calculations package Obstetrics / Gynecology (OB / GYN) calculations package Gynecology (GYN) Abdominal exam measurements and calculations Urology Endocrinology Vascular exam measurements and calculations Cardiology
Veterinary Calculations Packages
Obstetrics:
Canine / Feline / Ovine / Bovine / Equine / Llama / Goat
Animal Cardiology
User Interface
The set of predefined skin schemes for user interface User-friendly pop-up menus and dialogue boxes Unlimited programmable presets for clinically specific
imaging
Image comment / save / recall browsing Anatomical Icons with probe position indicator
Indication
Power LED indicator of system status
Image and video save / load
JPG BMP PNG TIF AVI DCM DCM(JPG) TVD TPD
Cineloop
Recording up to 2048 frames to memory Play / Pause / Stop / Frame selection Saving ultrasound video file to disk Loading ultrasound video file from disk
Printing
System printer
TELEMED ClarUs User Guide, REV 4.0 2013.12.04
10
Internet
Direct e-mail sending function with image or video attachment
TV output
Standard TV output using computer's display adapter
(option)
ULTRASOUND SOFTWARE
Drivers
TELEMED Drivers Package
Software
Echo Wave II software (B/W + Doppler modes)
Plug-Ins
ClearView plug-in (optional) 3DView plug-in (optional) PanoView plug-in (optional)
Library for programmers
SDK documentation / sample code (available by agreement)
DIMENSIONS AND WEIGHT
Dimensions W x D x H mm
335 x 230 x 75 ClarUs 62 x 210 x 165 ClarUs EXT-1M
Weight, kg
 4.5 ClarUs  1.6 ClarUs EXT-1M
POWER ClarUs
100-240 VAC 47-63 Hz 100VA Built-in 60 watt-hour
lithium-polymer battery
battery life: 60 min (depending on scan mode) battery charging time: up to 2 hours
POWER ClarUs EXT-1M
12 VDC
2.5 A
External AC medical grade power supply (100-240 VAC,
50-60 Hz)
SAFETY
Electromechanical safety
IEC601-1-2 Medical electrical equipment part 1: General
requirements for safety.
Class I Type BF applied part
EMC/EMI standards
European Norm EN 55011:1998 (CISPR 11:1999)
Industrial, scientific and medical (ISM) radio-frequency equipment. Radio disturbance characteristics. Limits and methods of measurement.
Ultrasound exposure
CEI/IEC 61157:1992, International Electro technical
Commission, Requirements for The Declaration of the Acoustic Output of Medical Diagnostic Ultrasonic Equipment.
AIUM/NEMA: Standard for real-time display of thermal
and mechanical acoustic output indices on diagnostic
TELEMED ClarUs User Guide, REV 4.0 2013.12.04
11
ultrasound equipment.1992.
OPERATIONAL ENVIRONMENT
Nominal operational environment
Environment temperature : 10 - 40 ° C Relative humidity not to exceed: 85 % Atmospheric pressure: 70 - 106 kPa
TELEMED ClarUs User Guide, REV 4.0 2013.12.04
12
2. SAFETY
CAUTION : Please read this information before using the diagnostic system. It applies to the ultrasound system, transducers, accessories and peripherals.
2.1. Electrical safety
This system complies with the applicable medical equipment requirements and meets IEC601-1, Class I Type BF safety requirements.
NOTE : All persons connecting computer equipment as medical appliance are configuring a medical system and are therefore responsible for ensuring that the system complies with IEC 601-1-1. The achievement of PC compliance with the IEC 601-1 requirements is based on electrical safety. A standard PC power supply is almost certain to not comply with IEC 601-1 electrical requirements in several ways , e.g. leakage current requirements, dielectric strength requirements. One possible solution is powering the PC (and computer monitor) via a 1:1 medical insulation transformer, which has been designed to meet IEC 60601-1 requirements. The best solution is a fully IEC 601-1 certified PC or a battery operated portable PC and wireless peripheral devices. All systems (including monitors and other connected parts) must be configured to comply with IEC 601-1-1. If in any doubt please contact the technical service department of your local representative. Note that regardless of the above stipulations all personal computers used should be approved regarding the IT (information technology) safety standards for electrical ) equipment (such as. IEC 60950 or equivalent) .
The electrical specification is shown below and can be found labelled on the rear panel of scanner.
To avoid electrical shock only use the supplied power cables and connect it to a properly earthed power socket. Do not use a three pin - two pin adapter. This defeats the whole purpose of earthing for safety reasons. Systems should be operated within the voltage limits.
WARNING: In the event of detecting a discrepancy regarding patient safety requirements (occurrence or probability of risk) you must to inform the local dealer and the manufacturer immediately (for single European customers – inform the EC representative labeled on the rear panel).
TELEMED ClarUs User Guide, REV 4.0 2013.12.04
13
If the ultrasound scanner will be moved or left unused for a long period of time without being switched on it is recommended that it be disconnected from power supply. If a scanner is to be switched on, do not interrupt this while operating the system and while the ultrasound software is being loaded. The time for this operation is approximately 1 min.
To avoid the risk of electrical shock and fire hazard:
before using the probe, inspect the probe face, housing, and cable and do not
use the probe if the probe or the cable is damaged;
always disconnect the AC power supply from the system before cleaning the
system;
do not use any probe that has been immersed beyond the specified cleaning
or disinfection level;
inspect the power supply, AC power supply cable and electrical plug on a
regular basis to ensure they are not damaged;
only use accessories and peripherals recommended by TELEMED.
WARNING: To avoid the risk of electrical shock do not open the cover of device/blocks. There are no parts that you can repair yourself. In case of dificulties please contact the TELEMED service department or your nearest local authorized distributor.
2.2. Equipment protection
To protect your ultrasound system, transducer and accessories, please follow these precautions:
excessive bending or twisting of electrical cables can cause a failure or
intermittent operation;
incorrect cleaning or disinfecting of any system part can cause permanent
damage, for cleaning and disinfecting instructions see the relevant chapter
below;
do not use solvents such as thinners/benzene or abrasive cleaners on any
parts of the system;
do not spill liquids on the system; incorrect assembly or configuration and using an incorrect power source may
damage the system.
WARNING: Ultrasound probes can easily be damaged by incorrect handling! Failure to follow these precautions can result in serious injury and equipment damage!
2.3. Biological safety
Observe the following precautions related to biological safety:
do not use the system if it displays erratic or inconsistent behavior;
TELEMED ClarUs User Guide, REV 4.0 2013.12.04
14
interuptions to the scanning sequence are signs of hardware failure that must
be corrected before use;
do not use the system if it displays artifacts on the LCD screen, either within
the clinical image or on the area outside it;
artifacts are indications of hardware and/or software errors that must be
corrected before use;
The hardware limits the maximum probe surface temperature to a maximum of 43°C even in the event of a device malfunction.
2.4. Ultrasound exposure and ALARA principle
Perform ultrasound procedures prudently, use the ALARA (As low As Reasonably Achievable) principle (see APPENDIX: 1.Guidelines for the safe use of diagnostic ultrasound). The interactive system features or user controls that may affect the acoustic output are:
acoustic output control, transmit frequency; scanning depth; transmit focal length; scanning angle.
Acoustic output also depends on the imaging mode selected. The choice of mode (B­Mode, M-Mode, B+M-Mode) determines whether the ultrasound beam is stationary or in motion. B+M-Mode has the highest acoustic output. The default output level is factory calibrated and is based on device settings that yield an optimum image for the type of patient examination and do not exceed the following FDA recommended limits. This default level is set:
when the system is first turned on; when the probe is first turned on.
It is highly recommended to set the default level:
when changing from one exam category to another; when changing from one application to another; when changing from one probe to another; when a new patient is entered.
Once an optimal image is achieved, the need for increasing acoustic output or prolonging the exposure cannot be justified. Watch the POWER level (on-screen display) permanently. Whenever possible, controls and system features should be used to optimize the image before increasing the acoustic output level. Follow the ALARA principle during all patient examinations. The ClarUs employs the ALARA principle in configuring factory defaults.
CAUTION: Probe sheaths/covers may contain talc and natural rubber latex. Examine the package labeling to confirm any latex content. We strongly recommend that healthcare professionals identify their latex-sensitive patients and refer to the FDA regulations. NOTE: TELEMED diagnostic ultrasound systems and probes do not contain natural rubber latex that comes into contact with humans.
Loading...