Telefunken TSOP1156GL1, TSOP1133GL1, TSOP1138GL1, TSOP1140GL1, TSOP1137GL1 Datasheet

...
TSOP11..GL1
Vishay Telefunken
Photo Modules for PCM Remote Control Systems
Available types for different carrier frequencies
Type fo Type fo TSOP1130GL1 30 kHz TSOP1133GL1 33 kHz TSOP1136GL1 36 kHz TSOP1137GL1 36.7 kHz TSOP1138GL1 38 kHz TSOP1140GL1 40 kHz TSOP1156GL1 56 kHz
Description
The TSOP1 1..GL1 – series are miniaturized receivers for infrared remote control systems. PIN diode and preamplifier are assembled on lead frame, the epoxy package is designed as IR filter. The demodulated output signal can directly be de­coded by a microprocessor. The main benefit is the operation with short burst transmission codes (e.g. RECS 80) and high data rates.
Features
D
Photo detector and preamplifier in one package
D
Internal filter for PCM frequency
D
Improved shielding against electrical field disturbance
D
TTL and CMOS compatibility
D
Output active low
D
Low power consumption
D
High immunity against ambient light
Input
PIN
AGC
Special Features
D
Enhanced data rate of 2400 bit/s
D
Operation with short bursts possible (6 cycles/burst)
Control
Circuit
Band
Pass
Demodu-
GND
lator
V
S
OUT
GND
94 8692
V
S
OUT
2
80 k
W
3
1
Document Number 82145
94 8136
www.vishay.com
1 (8)Rev. 3, 29-Mar-01
TSOP11..GL1
Supply Current (Pin 2)
Irradiance (30
kHz)
E
mW/m
2
Irradiance (56 kHz)
E
Vishay Telefunken
Absolute Maximum Ratings
T
= 25_C
amb
Parameter Test Conditions Symbol Value Unit Supply Voltage (Pin 2) V Supply Current (Pin 2) I Output Voltage (Pin 3) V Output Current (Pin 3) I Junction Temperature T Storage Temperature Range T Operating Temperature Range T Power Consumption (T Soldering Temperature t x 5 s T
Basic Characteristics
T
= 25_C
amb
Parameter Test Conditions Symbol Min Typ Max Unit
pp Supply Voltage (Pin 2) V Transmission Distance
Output Voltage Low (Pin 3)
– 40
Irradiance Test signal see fig.7 E Directivity Angle of half transmission distance ϕ
VS = 5 V, Ev = 0 I VS = 5 V, Ev = 40 klx, sunlight I
Ev = 0, test signal see fig.8, IR diode TSAL6200, I
I
= 0.5 mA,Ee = 0.7 mW/m2,
OSL
f = fo, test signal see fig.7 Test signal see fig.7 Test signal see fig.8 Test signal see fig.7 Test signal see fig.8
x 85 °C) P
amb
= 0.4 A
F
SD SH
S
d 35 m
V
OSL
e min
e min
e max
1/2
S
S
O
O
j
stg
amb
tot sd
–0.3...6.0 V
5 mA
–0.3...6.0 V
5 mA
100 –25...+85 –25...+85
50 mW
260
0.4 0.6 1.5 mA 1 mA
4.5 5.5 V
250 mV
0.4 0.6
0.35 0.5
0.45 0.7
0.40 0.6
30 W/m
±45 deg
°
C
°
C
°
C
°
C
2
Application Circuit
100 W *)
2
3
4.7 mF *) >10 k
W
optional
m
C
TSOP11..
TSAL62..
**)
12755
1
*) recommended to suppress power supply disturbances **) The output voltage should not be hold continuously at a voltage below 3.3V by the external circuit.
www.vishay.com
2 (8)
+5V
GND
Document Number 82145
Rev. 3, 29-Mar-01
Suitable Data Format
The circuit of the TSOP1 1..GL1 is designed in that way that unexpected output pulses due to noise or disturbance signals are avoided. A bandpassfilter, an integrator stage and an automatic gain control are used to suppress such disturbances. The distinguishing mark between data signal and disturbance signal are carrier frequency, burst length and duty cycle.
The data signal should fullfill the following condition:
TSOP11..GL1
Vishay Telefunken
Some examples for suitable data format are: NEC Code, T oshiba Micom Format, Sharp Code, RC5 Code, RC6 Code, RCMM Code, R–2000 Code, RECS–80 Code.
When a disturbance signal is applied to the TSOP11..GL1 it can still receive the data signal. However the sensitivity is reduced to that level that no unexpected pulses will occure.
Carrier frequency should be close to center frequency of the bandpass (e.g. 38kHz).
Burst length should be 6 cycles/burst or longer.
After each burst which is between 6 cycles and 70
cycles a gap time of at least 10 cycles is neccessary.
For each burst which is longer than 1.8ms a corresponding gap time is necessary at some time in the data stream. This gap time should have at least same length as the burst.
Up to 2200 short bursts per second can be received continuously .
0 5 10 15 20
Some examples for such disturbance signals which are suppressed by the TSOP11..GL1 are:
DC light (e.g. from tungsten bulb or sunlight)
Continuous signal at 38kHz or at any other
frequency
Signals from fluorescent lamps with electronic ballast (an example of the signal modulation is in the figure below).
Document Number 82145
time [ms]
IR Signal from Fluorescent Lamp with low Modulation
www.vishay.com
3 (8)Rev. 3, 29-Mar-01