Serial Trigger and Decode
Waveform Generation - Built-in
–
Function Generator
Digital Voltmeter and Frequency
–
Counter
Future Proof
Upgradeable Bandwidth
–
Field Upgradable Software and
–
Hardware Options
Superior User Experience
MAUI is the most advanced
oscilloscope user interface. It is
designed for touch, built for simplicity,
and made to solve.
Advanced Anomaly Detection
A fast waveform update rate, used
in conjunction with history mode,
WaveScan, sequence mode, and
mask testing facilitates outstanding
waveform anomaly detection.
Biggest Touch Display
A large capacitive touch screen
enables accessible and responsive
touch operation. The 10.1” display is
30% larger than competitive offerings,
providing more waveform viewing area.
Powerful, Deep Toolbox
The standard collection of
math, measurement, debug, and
documentation tools provides
unsurpassed analysis capabilities.
6
MAUI – SUPERIOR USER EXPERIENCE
Designed for Touch
MAUI is designed for touch. Operate
the oscilloscope just like a phone or
tablet with the most unique touch
screen features on any oscilloscope. All
important controls are always one touch
away. Touch the waveform to position
or zoom in for more details using
intuitive actions.
Built for Simplicity
MAUI is built for simplicity. Basic
waveform viewing and measurement
tools as well as advanced math and
analysis capabilities are seamlessly
integrated in a single user interface.
Time saving shortcuts and intuitive
dialogs simplify setup and shorten
debug time.
Made to Solve
MAUI is made to solve. A deep set of
integrated debug and analysis tools help
identify problems and nd solutions
quickly. Unsurpassed integration
provides critical flexibility when
debugging. Solve problems fast with
powerful analysis tools.
7
ADVANCED ANOMALY DETECTION
WaveScan Advanced Search
Locate unusual events in a single
•
capture or scan for an anomalies
across many acquisitions
More than 20 modes can be applied to
•
analog or digital channels
Pass/Fail Mask Testing
Mask testing to quickly identify
•
anomalies and mark their location.
A history of these pass/fail results can
•
be displayed
Fast Waveform Update
An update rate of over 130,000
•
waveforms per second will easily
display random or infrequent events
Changes over time can be seen with
•
the intensity graded persistence
display
8
Go Back in Time to Identify the Source of a Problem
A
B
A
B
A
B
A
B
A
B
A
B
A
B
UARTRS-232I2S
A
B
RS-232I2S
I2S
A
B
SPI
UARTRS-232I2S
History Mode Waveform
Playback
View previous waveforms to discover
•
past anomalies
Use cursors and measurement
•
parameters to quickly identify the
source of problems
History mode is always enabled and
•
accessible through the click of a
button
SPI
A
B
I2C
I2S
UART
RS-232
Powerful Triggering
Basic triggering such as edge or width
•
can be used for everyday solutions
Qualied triggering enables the ability
•
to trigger across multiple channels
Powerful logic triggering can be
•
setup to catch a parallel pattern
Smart triggers such as runt,
•
dropout, or interval help isolate
anomalies quickly
Serial data triggering adds protocol
•
specic triggers
Advanced Waveform Capture with
Segmented Memory
Save waveforms into segmented
•
memory
Capture fast pulses in quick
•
succession or events separated by
long time intervals
Combine Sequence mode with
•
advanced triggers to isolate rare
events
9
MULTI-INSTRUMENT CAPABILITIES
Protocol Analysis with
Serial Trigger and Decode
Intuitive, color-coded overlay
•
presented in binary, hex, or decimal
Trigger capabilities allow for a wide
•
range of different events
All decoded data is displayed in an
•
interactive table
Precise Measurements with
Digital Voltmeter
4-digit digital voltmeter
•
5-digit frequency counter
•
Any channel can be selected as a
•
source
Voltage readings can be set to DC, DC
•
RMS, or AC RMS
Measurements will continue to be
•
updated even when triggering is
stopped
10
Logic Analysis with 16 Channel
Mixed Signal Capability
Simultaneously view, measure, and
•
analyze both analog and 16 digital
signals
Analog and digital channels can be
•
incorporated into a single pattern trigger
WaveScan, trends, statistics, and
•
histicons provide insight to nd
anomalies in digital waveforms
Waveform Generation with
Built-in Function Generator
Frequencies of up to 25 MHz
•
Waveform Options: sine, square, pulse,
•
ramp, triangle, noise and DC waveforms
Rear panel BNC output
•
Saved waveforms can be uploaded into
•
the WaveSource to generate arbitrary
waveforms
11
POWERFUL, DEEP TOOLBOX
Advanced Math Capabilities
A deep set of 20 math functions
•
provide quick insight into waveforms
Dedicated Grid for Math Traces
•
Any Channel, Measurement, or
•
Analysis Package can have a math
function applied
Superior Measurement Tools
24 measurement parameters
•
Additional statistics and histicons can
•
be applied to each parameter
Trends can be displayed for any
•
measurement
LabNotebook
Documentation Tool
Save all displayed waveforms,
•
oscilloscope setup le, and a screen
image with a single button press
Recall LabNotebook les onto the
•
oscilloscope
12
View the LabNotebook les on a PC
•
using WaveStudio
PROBES
Teledyne LeCroy offers an extensive range of probes to meet virtually every probing need.
ZS Series
High Impedance
Active Probes
(1 GHz - 1.5 GHz)
The active voltage probe can become the everyday probe for all
different types of signals and connection points.
Differential Probes
(200 MHz – 1.5 GHz)
These active differential probes are ideal for applications such as
automotive electronics and data communications.
Active Voltage/Power
Rail Probe (4 GHz)
The Active Rail Probe is specically designed to probe a low
impedance power/voltage rail.
High Voltage
Fiber Optically-isolated
Probes
High Voltage
Differential Probes
(120
MHz)
HVDs are rated for wide differential voltage swings - ideal for
power electronics circuits.
High Voltage
Passive Probes
High Voltage Single-ended passive probes that are ideal for
lightning/surge or EFT testing, or for probing in-circuit beyond
the range of a LV-rate passive probe.
Current Probes
(100 MHz)
Current probes with peak currents of 700 A and sensitivities
to 1mA/div. Ideal for component or power conversion system
input/output measurements.
Probe and Current
Sensor Adapters
The HVFO108 is ideal for measurement of small signals floating
on an HV bus in power electronics designs or for EMC, EFT, ESD,
and RF immunity testing sensor monitoring.
Acquisition ModesReal Time, Roll, RIS (Random Interleaved Sampling),
Real Time Timebase Range5 ns/div - 100 s/div 2 ns/div - 100 s/div1 ns/div - 100 s/div500 ps/div - 100 s/div
RIS Mode Timebase Range5 ns/div - 10 ns/div2 ns/div - 10 ns/div1 ns/div - 10 ns/div500 ps/div - 10 ns/div
Roll Mode Timebase RangeUp to 100 s/div (roll mode is user selectable at ≥ 50 ms/div)
Timebase Accuracy±10 ppm measured over > 1ms interval
Digital - Vertical and Acquisition (WS3K-MSO Option Only)
Input Channels16 Digital Channels
Threshold GroupingsPod 2: D15 - D8, Pod 1: D7 - D0
Threshold SelectionsTTL(+1.4V), 5V CMOS (+2.5V), ECL (-1.3V) or User Dened
Maximum Input Voltage±30V Peak
Threshold Accuracy±(3% of threshold setting + 100mV)
Input Dynamic Range±20V
Minimum Input Voltage Swing500mVpp
Input Impedance (Flying Leads)100 kΩ || 5 pF
Maximum Input Frequency125 MHz
Sample Rate500 MS/s
Record Length10MS - 16 Channels
Minimum Detectable Pulse Width4 ns
Channel-to-Channel Skew± (1 digital sample interval)
User dened threshold range±10V in 20mV steps
Trigger System
ModesAuto, Normal, Single, Stop
SourcesAny input channel, External, Ext/5, or line; slope and level unique to each source (except for line trigger)
CouplingDC, AC, HFREJ, LFREJ
Pre-trigger Delay0-100% of full scale
Post-trigger Delay0-10,000 Divisions
Hold-off10ns up to 20s or 1 to 100,000,000 events
Internal Trigger Level Range±4.1 Divisions
External Trigger Level RangeExt: ±610mV, Ext/5: ±3.05V
Trigger TypesEdge, Width, Logic (Pattern), TV (NTSC, PAL, SECAM, HDTV - 720p, 1080i, 1080p), Runt, Slew Rate,
Measure, Zoom and Math Tools
Measurement ParametersUp to 6 of the following parameters can be calculated at one time on any waveform: Amplitude, Area, Base, Delay,
ZoomingUse front panel QuickZoom button, or use touch screen or mouse to draw a box around the zoom area.
Math FunctionsUp to 2 of the following functions can be calculated at one time: Sum, Difference, Product, Ratio, Absolute Value,
Probes
Standard ProbesOne PP019 (5mm) per channelOne PP020 (5mm) per channel
Probing SystemBNC and Teledyne LeCroy ProBus for Active voltage, current and differential probes
Sequence (Segmented Memory up to 1,000 segments with 1μs minimum intersegment time)
Interval (Signal or Pattern), Dropout, Qualied (State or Edge); External and Ext/5 support edge trigger only.
Duty Cycle, Fall Time (90%–10%), Fall Time (80%–20%), Frequency, Maximum, Mean, Minimum, Overshoot+,
Overshoot-, Peak-Peak, Period, Phase, Rise Time (10%–90%), Rise Time (20%–80%), RMS, Skew, Standard
Deviation, Top, Width+, Width-. Statistics and histicons can be added to measurements. Measurements can be gated.
Average, Derivative, Enhanced Resolution, Envelope, Floor, Integral, Invert, Reciprocal, Rescale, Roof, SinX/x, Square,
Square Root, Trend, Zoom and FFT (up to 1 Mpts with power spectrum output and rectangular, VonHann, and FlatTop
windows).
Display Size10.1” widescreen capacitive touch screen
Display Resolution1024 x 600
Connectivity
Ethernet Port10/100Base-T Ethernet interface (RJ-45 connector)
Removable Storage(1) MicroSD Port - 16 GB micro SD card installed standard
USB Host Ports(4) USB 2.0 Ports Total – (2) Front USB 2.0 Ports
USB Device Port(1) USBTMC
GPIB Port (Optional)Supports IEEE – 488.2
External Monitor PortStandard DB-15 connector (support resolution of 1024x600)
Remote ControlVia Windows Automation, or via Teledyne LeCroy Remote Command Set
Network Communication
Standard
Power Requirements
Voltage100 - 240 VAC ± 10% at 50-60 Hz +/-5%; 100 - 120 VAC ± 10% at 400 Hz +/- 5%; Automatic AC Voltage Selection
Power Consumption (Nominal)80 W / 80 VA
Power Consumption (Max)150 W / 150 VA (with all PC peripherals, digital leadset and active probes connected to 4 channels)
Environmental
TemperatureOperating: 0 °C to 50 °C; Non-Operating: -30 °C to 70 °C
HumidityOperating: 5% to 90% relative humidity (non-condensing) up to ≤ 30 °C, Upper limit derates to 50% relative humidity
AltitudeOperating: 3,048 m (10,000 ft) max at ≤ 25C; Non-Operating: Up to 12,192 meters (40,000 ft)
Physical
Dimensions (HWD)10.63”H x 14.96”W x 4.92”D (270 mm x 380 mm x 125 mm)
Weight4.81 kg (10.6 lbs)
Regulatory
CE Certication Low Voltage Directive 2014/35/EU; EN 61010-1:2010, EN 61010-2-030:2010
UL and cUL ListingUL 61010-1, UL 61010-2-030:2010, 3rd Edition; CAN/CSA C22.2 No. 61010-1-12
Measurement Rate100 times/second, measurements update on the display 5 times/second
Vertical Settings AutorangeAutomatic adjustment of vertical settings to maximize the dynamic range of measurements
VICP and LXI compatible
(non-condensing) at +50 °C
Non-Operating: 5% to 95% relative humidity (non-condensing) as tested per MIL-PRF-28800F
EMC Directive 2014/30/EU; EN 61326-1:2013, EN61326-2-1:2013; RoHS2 Directive 2011/65/EU
AC
rms
, DC, DC
, Frequency
rms
WaveSource Function Generator (optional)
General
Max Frequency25 MHz
Channels1
Sample Rate125 MS/s
Arbitrary Waveform
Length
Frequency Resolution 1 μHz
Vertical Resolution14-bit
Vertical Range±3V (HiZ); ±1.5V (50 Ω)
Waveform TypesSine, Square, Pulse, Ramp, Noise, DC
Frequency Specication
Sine1 μHz - 25 MHz
Square/Pulse1 μHz - 10 MHz
Ramp/Triangular1 μHz - 300 KHz
Noise25 MHz (-3dB)
Resolution1 μHz
Accuracy±50 ppm, over temperature
Aging±3 ppm/year, rst year
÷10 Passive Probe (Total of 1 Per Channel), 1 Micro SD card (Installed),
Micro SD card adapter,
Protective Front Cover, Getting Started Guide,
Commercial NIST Traceable Calibration with Certicate, Power Cable for
the Destination Country, 3-year Warranty
General Accessories
External GPIB AccessoryUSB2-GPIB
Soft Carrying CaseWS3K-SOFTCASE
Rack Mount AccessoryWS3K-RACK
Multi-Instrument Options
MSO software option and 16 Channel Digital probe leadsetWS3K-MSO
MSO License (MS Probe Not Included)WS3K-MSO-LICENSE
Function Generator OptionWS3K-FG
Spectrum Analyzer for WaveSurfer 3000zWS3K-SPECTRUM-1
Audiobus Trigger and Decode Option for I
and TDM
CAN and LIN Trigger and Decode OptionWS3K-AUTO
CAN FD Trigger and Decode OptionWS3K-CAN FDbus TD
2
I
C, SPI, UART and RS-232 Trigger and Decode OptionWS3K-EMB
FlexRay Trigger and Decode OptionWS3K-FlexRaybus TD
Power Analysis OptionWS3K-PWR
1.2x attenuation, ±30V offset, ±800mV
Browser for use with RP4030RP4000-BROWSER
1,500 V, 120 MHz High-Voltage Differential ProbeHVD3106A
1kV, 80 MHz High Voltage Differential Probe with 6m cableHVD3106A-6M
1kV, 120 MHz High Voltage Differential Probe
without tip Accessories
1,500 V, 25 MHz High-Voltage Differential ProbeHVD3102A
1kV, 25 MHz High Voltage Differential Probe without
tip Accessories
2kV, 120 MHz High Voltage Differential ProbeHVD3206A
2kV, 80 MHz High Voltage Differential Probe with 6m cableHVD3206A-6M
2kV, 400 MHz High Voltage Differential ProbeHVD3220
6kV, 100 MHz High Voltage Differential ProbeHVD3605A
High Voltage Fiber Optic Probe, 150 MHz
(requires accessory tip)
±1V (1x) Tip Accessor
y for HVFO103HVFO100-1X-TIP
±5V (5x) Tip Accessory for HVFO103HVFO100-5X-TIP
±20V (20x) Tip Accessory for HVFO103HVFO100-20X-TIP
30 A; 100 MHz Current Probe – AC/DC; 30 A
30 A; 100 MHz High Sensitivity Current Probe – AC/DC;
30 A
rms;
50 A
peak
Pulse
30 A; 50 MHz Current Probe – AC/DC; 30 A
30 A, 10 MHz Current Probe - AC/DC, 30 A rms, 50 A
3 meter cable
30 A; 50 MHz High Sensitivity Current Probe – AC/DC; 30 A
50 A
Pulse
peak
150 A; 10 MHz Current Probe – AC/DC; 150 A
150 A, 5 MHz Current Probe - AC/DC, 150 A rms, 500 A
Pulse, 6 meter cable
500 A; 2 MHz Current Probe – AC/DC; 500 A
Deskew Calibration Source for CP031, CP030 and AP015DCS025
500 MHz Differential ProbeAP033