Teledyne LeCroy Lecroy WAVESURFER 3014Z Brochure

BIGGEST TOUCH. BEST VALUE.
100 MHz – 1 GHz Oscilloscopes
10.1” Capacitive Touch Screen
20 Mpts Memory
Powerful, Deep Toolbox
The WaveSurfer 3000z has a 10.1” capacitive touch display, the longest memory, and the
deepest toolbox – all at an affordable price.
BIGGEST TOUCH.
+
BEST VALUE.
30% Larger
Biggest Touch
Best
10.1”
2
Value
The WaveSurfer 3000z has a 10.1” capacitive touch display, the longest memory, and the
deepest toolbox – all at an affordable price.
Insight alone is not enough.
10.1” Capacitive Touch Screen
1
20 Mpts Memory
2
Powerful, Deep Toolbox
3
Faster Time to Insight
Markets and technologies
change too rapidly.
The timing of
critical design
decisions is signicant.
Faster Time to Insight is what matters.
3
THE WAVESURFER 3000Z ATTRIBUTES
Test Equipment Depot - 800.517.8431 - 5 Commonwealth Ave, MA 01801 - TestEquipmentDepot.com
The WaveSurfer 3000z provides the
Most Advanced User Interface (MAUI)
through a 10.1” capacitive touch
screen. It promotes true versatility with
20 Mpts of memory, multi-instrument
capabilities, a powerful, deep toolbox,
and 100 MHz - 1 GHz of bandwidth.
Key Attributes
1. 10.1" widescreen capacitive touch
screendisplay
2
1
2. MAUI - Most Advanced User Interface
Waveform Control Knobs for channel,
3.
zoom, math and memory traces
4. “Push” Knobs - push functionality
provides shortcuts to common actions
5. Dedicated buttons to quickly
access popular debug tools.
6. Mixed Signal Capability - 16 channel
mixed signal capability
Easy connectivity with an ethernet
7.
and four USB 2.0 Ports
8. Rotating and tilting feet for four
different viewing positions
4
3
4
5
8
9. WaveSource Ouput for Built-in
Function Generator
Micro SD Port - 16 GB (or larger) micro
10.
SD card installed standard
11. External Monitor DB-15 connector
(Support resolution of 1024 x 600)
12. USBTMC (Test and Measurement
Class) over USB 2.0 for remote
connectivity
13. Small Footprint
7
6
10
9
7
11
12
5
WAVESURFER 3000z AT A GLANCE
Key Features
100 MHz, 200 MHz, 350 MHz, 500 MHz and 1 GHz bandwidths
Up to 4 GS/s sample rate
Long Memory – up to 20 Mpts
10.1” capacitive touch screen display
16 Digital Channel MSO option
MAUI - Most Advanced User Interface
Designed for Touch
Built for Simplicity
Made to Solve
Advanced Anomaly Detection
Fast Waveform Update
History Mode - Waveform Playback
WaveScan - Search and Find
Multi-Instrument Capabilities
Protocol Analysis -
Serial Trigger and Decode Waveform Generation - Built-in
Function Generator Digital Voltmeter and Frequency
Counter
Future Proof
Upgradeable Bandwidth
Field Upgradable Software and
Hardware Options
Superior User Experience
MAUI is the most advanced
oscilloscope user interface. It is
designed for touch, built for simplicity,
and made to solve.
Advanced Anomaly Detection
A fast waveform update rate, used
in conjunction with history mode,
WaveScan, sequence mode, and
mask testing facilitates outstanding
waveform anomaly detection.
Biggest Touch Display
A large capacitive touch screen
enables accessible and responsive
touch operation. The 10.1” display is
30% larger than competitive offerings,
providing more waveform viewing area.
Powerful, Deep Toolbox
The standard collection of
math, measurement, debug, and
documentation tools provides
unsurpassed analysis capabilities.
6
MAUI – SUPERIOR USER EXPERIENCE
Designed for Touch
MAUI is designed for touch. Operate
the oscilloscope just like a phone or
tablet with the most unique touch
screen features on any oscilloscope. All
important controls are always one touch
away. Touch the waveform to position
or zoom in for more details using
intuitive actions.
Built for Simplicity
MAUI is built for simplicity. Basic
waveform viewing and measurement
tools as well as advanced math and
analysis capabilities are seamlessly
integrated in a single user interface.
Time saving shortcuts and intuitive
dialogs simplify setup and shorten
debug time.
Made to Solve
MAUI is made to solve. A deep set of
integrated debug and analysis tools help
identify problems and nd solutions
quickly. Unsurpassed integration
provides critical flexibility when
debugging. Solve problems fast with
powerful analysis tools.
7
ADVANCED ANOMALY DETECTION
WaveScan Advanced Search
Locate unusual events in a single
capture or scan for an anomalies
across many acquisitions
More than 20 modes can be applied to
analog or digital channels
Pass/Fail Mask Testing
Mask testing to quickly identify
anomalies and mark their location.
A history of these pass/fail results can
be displayed
Fast Waveform Update
An update rate of over 130,000
waveforms per second will easily
display random or infrequent events
Changes over time can be seen with
the intensity graded persistence
display
8
Go Back in Time to Identify the Source of a Problem
A
B
A
B
A
B
A
B
A
B
A
B
A
B
UART RS-232 I2S
A
B
RS-232 I2S
I2S
A
B
SPI
UART RS-232 I2S
History Mode Waveform Playback
View previous waveforms to discover
past anomalies
Use cursors and measurement
parameters to quickly identify the
source of problems
History mode is always enabled and
accessible through the click of a
button
SPI
A
B
I2C
I2S
UART
RS-232
Powerful Triggering
Basic triggering such as edge or width
can be used for everyday solutions
Qualied triggering enables the ability
to trigger across multiple channels
Powerful logic triggering can be
setup to catch a parallel pattern
Smart triggers such as runt,
dropout, or interval help isolate
anomalies quickly
Serial data triggering adds protocol
specic triggers
Advanced Waveform Capture with Segmented Memory
Save waveforms into segmented
memory
Capture fast pulses in quick
succession or events separated by
long time intervals
Combine Sequence mode with
advanced triggers to isolate rare
events
9
MULTI-INSTRUMENT CAPABILITIES
Protocol Analysis with Serial Trigger and Decode
Intuitive, color-coded overlay
presented in binary, hex, or decimal
Trigger capabilities allow for a wide
range of different events
All decoded data is displayed in an
interactive table
Precise Measurements with Digital Voltmeter
4-digit digital voltmeter
5-digit frequency counter
Any channel can be selected as a
source
Voltage readings can be set to DC, DC
RMS, or AC RMS
Measurements will continue to be
updated even when triggering is
stopped
10
Logic Analysis with 16 Channel Mixed Signal Capability
Simultaneously view, measure, and
analyze both analog and 16 digital
signals
Analog and digital channels can be
incorporated into a single pattern trigger
WaveScan, trends, statistics, and
histicons provide insight to nd
anomalies in digital waveforms
Waveform Generation with Built-in Function Generator
Frequencies of up to 25 MHz
Waveform Options: sine, square, pulse,
ramp, triangle, noise and DC waveforms
Rear panel BNC output
Saved waveforms can be uploaded into
the WaveSource to generate arbitrary
waveforms
11
POWERFUL, DEEP TOOLBOX
Advanced Math Capabilities
A deep set of 20 math functions
provide quick insight into waveforms
Dedicated Grid for Math Traces
Any Channel, Measurement, or
Analysis Package can have a math
function applied
Superior Measurement Tools
24 measurement parameters
Additional statistics and histicons can
be applied to each parameter
Trends can be displayed for any
measurement
LabNotebook Documentation Tool
Save all displayed waveforms,
oscilloscope setup le, and a screen
image with a single button press
Recall LabNotebook les onto the
oscilloscope
12
View the LabNotebook les on a PC
using WaveStudio
PROBES
Teledyne LeCroy offers an extensive range of probes to meet virtually every probing need.
ZS Series High Impedance Active Probes (1 GHz - 1.5 GHz)
The active voltage probe can become the everyday probe for all different types of signals and connection points.
Differential Probes (200 MHz – 1.5 GHz)
These active differential probes are ideal for applications such as automotive electronics and data communications.
Active Voltage/Power Rail Probe (4 GHz)
The Active Rail Probe is specically designed to probe a low
impedance power/voltage rail.
High Voltage Fiber Optically-isolated Probes
High Voltage Differential Probes (120
MHz)
HVDs are rated for wide differential voltage swings - ideal for power electronics circuits.
High Voltage Passive Probes
High Voltage Single-ended passive probes that are ideal for lightning/surge or EFT testing, or for probing in-circuit beyond the range of a LV-rate passive probe.
Current Probes (100 MHz)
Current probes with peak currents of 700 A and sensitivities
to 1mA/div. Ideal for component or power conversion system
input/output measurements.
Probe and Current Sensor Adapters
The HVFO108 is ideal for measurement of small signals floating on an HV bus in power electronics designs or for EMC, EFT, ESD, and RF immunity testing sensor monitoring.
TPA10 adapts supported Tektronix TekProbe-compatible probes to Teledyne LeCroy ProBus interface.
13
SPECIFICATIONS
WaveSurfer 3014z WaveSurfer 3024z WaveSurfer 3034z WaveSurfer 3054z WaveSurfer 3104z
Analog - Vertical
Analog Bandwidth @ 50Ω (-3dB) 100 MHz 200 MHz 350 MHz 500 MHz 1 GHz Rise time 3.5 ns (typical) 1.75 ns (typical) 1 ns (typical) 800 ps (typical) 430 ps (typical) Input Channels 4 Vertical Resolution 8-bits; up to 11-bits with enhanced resolution (ERES) Sensitivity 50 Ω: 1mV/div - 1 V/div; 1 MΩ: 1 mV/div - 10 V/div DC Gain Accuracy ±(1.5%) Full Scale, Offset at 0V, > 5mV/div; ±(2.5%) < 5 mV/div BW Limit 20 MHz 20 MHz, 200 MHz Maximum Input Voltage 50 Ω: 5 Vrms, ±10 V Peak; 1 MΩ: 400 V max (DC + Peak AC 10 kHz) Input Coupling 50 Ω: DC, GND; 1 MΩ: AC, DC, GND Input Impedance 50 Ω ±2.0%, 1 MΩ ±2.0% || 16 pF Offset Range 50 Ω: 1 mV - 19.8 mV: ±2 V, 20 mV - 100 mV: ±5 V, 102 mV - 198 mV: ±20 V, 200 mV - 1 V: ±50 V
Offset Accuracy ±(1.0% of offset value + 1.5%FS + 1 mV)
Analog - Acquisition
Sample Rate (Single-shot) 1 GS/s
Sample Rate (Repetitive) 50 GS/s Standard Memory ( 4 Ch / 2 Ch) 10 Mpts / 20 Mpts
Acquisition Modes Real Time, Roll, RIS (Random Interleaved Sampling),
Real Time Timebase Range 5 ns/div - 100 s/div 2 ns/div - 100 s/div 1 ns/div - 100 s/div 500 ps/div - 100 s/div RIS Mode Timebase Range 5 ns/div - 10 ns/div 2 ns/div - 10 ns/div 1 ns/div - 10 ns/div 500 ps/div - 10 ns/div Roll Mode Timebase Range Up to 100 s/div (roll mode is user selectable at ≥ 50 ms/div) Timebase Accuracy ±10 ppm measured over > 1ms interval
Digital - Vertical and Acquisition (WS3K-MSO Option Only)
Input Channels 16 Digital Channels Threshold Groupings Pod 2: D15 - D8, Pod 1: D7 - D0 Threshold Selections TTL(+1.4V), 5V CMOS (+2.5V), ECL (-1.3V) or User Dened Maximum Input Voltage ±30V Peak Threshold Accuracy ±(3% of threshold setting + 100mV) Input Dynamic Range ±20V Minimum Input Voltage Swing 500mVpp Input Impedance (Flying Leads) 100 kΩ || 5 pF Maximum Input Frequency 125 MHz Sample Rate 500 MS/s Record Length 10MS - 16 Channels Minimum Detectable Pulse Width 4 ns Channel-to-Channel Skew ± (1 digital sample interval) User dened threshold range ±10V in 20mV steps
Trigger System
Modes Auto, Normal, Single, Stop Sources Any input channel, External, Ext/5, or line; slope and level unique to each source (except for line trigger) Coupling DC, AC, HFREJ, LFREJ Pre-trigger Delay 0-100% of full scale Post-trigger Delay 0-10,000 Divisions Hold-off 10ns up to 20s or 1 to 100,000,000 events Internal Trigger Level Range ±4.1 Divisions External Trigger Level Range Ext: ±610mV, Ext/5: ±3.05V Trigger Types Edge, Width, Logic (Pattern), TV (NTSC, PAL, SECAM, HDTV - 720p, 1080i, 1080p), Runt, Slew Rate,
Measure, Zoom and Math Tools
Measurement Parameters Up to 6 of the following parameters can be calculated at one time on any waveform: Amplitude, Area, Base, Delay,
Zooming Use front panel QuickZoom button, or use touch screen or mouse to draw a box around the zoom area. Math Functions Up to 2 of the following functions can be calculated at one time: Sum, Difference, Product, Ratio, Absolute Value,
Probes
Standard Probes One PP019 (5mm) per channel One PP020 (5mm) per channel Probing System BNC and Teledyne LeCroy ProBus for Active voltage, current and differential probes
1 MΩ: 1 mV - 19.8 mV: ±2 V, 20 mV - 100 mV: ±5 V, 102 mV - 198 mV: ±20 V, 200 mV - 1 V: ±50 V,
  1.02 V - 1.98 V: ±200 V, 2 V - 10 V: ±400 V
(2 GS/s interleaved)
Sequence (Segmented Memory up to 1,000 segments with 1μs minimum intersegment time)
Interval (Signal or Pattern), Dropout, Qualied (State or Edge); External and Ext/5 support edge trigger only.
Duty Cycle, Fall Time (90%–10%), Fall Time (80%–20%), Frequency, Maximum, Mean, Minimum, Overshoot+, Overshoot-, Peak-Peak, Period, Phase, Rise Time (10%–90%), Rise Time (20%–80%), RMS, Skew, Standard Deviation, Top, Width+, Width-. Statistics and histicons can be added to measurements. Measurements can be gated.
Average, Derivative, Enhanced Resolution, Envelope, Floor, Integral, Invert, Reciprocal, Rescale, Roof, SinX/x, Square, Square Root, Trend, Zoom and FFT (up to 1 Mpts with power spectrum output and rectangular, VonHann, and FlatTop windows).
2 GS/s
(4 GS/s interleaved)
14
SPECIFICATIONS
WaveSurfer 3014z WaveSurfer 3024z WaveSurfer 3034z WaveSurfer 3054z WaveSurfer 3104z
Display System
Display Size 10.1” widescreen capacitive touch screen Display Resolution 1024 x 600
Connectivity
Ethernet Port 10/100Base-T Ethernet interface (RJ-45 connector) Removable Storage (1) MicroSD Port - 16 GB micro SD card installed standard USB Host Ports (4) USB 2.0 Ports Total – (2) Front USB 2.0 Ports USB Device Port (1) USBTMC GPIB Port (Optional) Supports IEEE – 488.2 External Monitor Port Standard DB-15 connector (support resolution of 1024x600) Remote Control Via Windows Automation, or via Teledyne LeCroy Remote Command Set Network Communication Standard
Power Requirements
Voltage 100 - 240 VAC ± 10% at 50-60 Hz +/-5%; 100 - 120 VAC ± 10% at 400 Hz +/- 5%; Automatic AC Voltage Selection Power Consumption (Nominal) 80 W / 80 VA Power Consumption (Max) 150 W / 150 VA (with all PC peripherals, digital leadset and active probes connected to 4 channels)
Environmental
Temperature Operating: 0 °C to 50 °C; Non-Operating: -30 °C to 70 °C Humidity Operating: 5% to 90% relative humidity (non-condensing) up to ≤ 30 °C, Upper limit derates to 50% relative humidity
Altitude Operating: 3,048 m (10,000 ft) max at 25C; Non-Operating: Up to 12,192 meters (40,000 ft)
Physical
Dimensions (HWD) 10.63”H x 14.96”W x 4.92”D (270 mm x 380 mm x 125 mm) Weight 4.81 kg (10.6 lbs)
Regulatory
CE Certication Low Voltage Directive 2014/35/EU; EN 61010-1:2010, EN 61010-2-030:2010
UL and cUL Listing UL 61010-1, UL 61010-2-030:2010, 3rd Edition; CAN/CSA C22.2 No. 61010-1-12
Digital Voltmeter (optional)
Functions Resolution ACV/DCV: 4 digits, Frequency: 5 digits
Measurement Rate 100 times/second, measurements update on the display 5 times/second Vertical Settings Autorange Automatic adjustment of vertical settings to maximize the dynamic range of measurements
VICP and LXI compatible
(non-condensing) at +50 °C Non-Operating: 5% to 95% relative humidity (non-condensing) as tested per MIL-PRF-28800F
EMC Directive 2014/30/EU; EN 61326-1:2013, EN61326-2-1:2013; RoHS2 Directive 2011/65/EU
AC
rms
, DC, DC
, Frequency
rms
WaveSource Function Generator (optional)
General
Max Frequency 25 MHz Channels 1 Sample Rate 125 MS/s Arbitrary Waveform Length Frequency Resolution 1 μHz Vertical Resolution 14-bit Vertical Range ±3V (HiZ); ±1.5V (50 Ω) Waveform Types Sine, Square, Pulse, Ramp, Noise, DC
Frequency Specication
Sine 1 μHz - 25 MHz Square/Pulse 1 μHz - 10 MHz Ramp/Triangular 1 μHz - 300 KHz Noise 25 MHz (-3dB) Resolution 1 μHz Accuracy ±50 ppm, over temperature Aging ±3 ppm/year, rst year
Output Specication
Amplitude 4 mVpp - 6 Vpp (HiZ); 2 mVpp - 3 Vpp(50 Ω) Vertical Accuracy ±(0.3dB + 1 mV) Amplitude Flatness ±0.5dB
16 kpts
DC Offset
Range (DC) ±3V (HiZ); ±1.5V (50 Ω) Offset Accuracy ±(1% of offset value + 3 mV)
Waveform Output
Impedance 50 Ω ± 2% Protection Short-circuit protection
Sine Spectrum Purity
SFDR (Non Harmonic) @1.265Vpp DC-1 MHz -60dBc 1 MHz - 5 MHz -55dBc 5 MHz - 25 MHz -50dBc Harmonic Distortion @1.265Vpp DC - 5 MHz -50dBc 5 MHz - 25 MHz -45dBc
Square/Pulse
Rise/fall time 24 ns (10% - 90%) Overshoot 3% (typical - 1 kHz, 1 Vpp) Pulse Width 50 ns min. Jitter 500ps + 10ppm of period (RMS cycle to cycle)
Ramp/Triangle
Linearity 0.1% of Peak value output (typical - 1 kHz, 1 Vpp,
100% symmetric)
Symmetry 0% to 100%
15
ORDERING INFORMATION
Product Description Product Code
WaveSurfer 3000z Oscilloscopes
100 MHz, 2 GS/s, 4 Ch, 10 Mpts/Ch with
10.1” Capacitive Touch Screen Display 20 Mpts /Ch in interleaved mode 200 MHz, 4 GS/s, 4 Ch, 10 Mpts/Ch with
10.1” Capacitive Touch Screen Display 20 Mpts /Ch in interleaved mode 350 MHz, 4 GS/s, 4 Ch, 10 Mpts/Ch with
10.1” Capacitive Touch Screen Display 20 Mpts /Ch in interleaved mode 500 MHz, 4 GS/s, 4 Ch, 10 Mpts/Ch with
10.1” Capacitive Touch Screen Display 20 Mpts /Ch in interleaved mode 1 GHz, 4 GS/s, 4 Ch, 10 Mpts/Ch with
10.1” Capacitive Touch Screen Display 20 Mpts /Ch in interleaved mode
WaveSurfer 3014z
WaveSurfer 3024z
WaveSurfer 3034z
WaveSurfer 3054z
WaveSurfer 3104z
Included with Standard Congurations
÷10 Passive Probe (Total of 1 Per Channel), 1 Micro SD card (Installed), Micro SD card adapter,
Protective Front Cover, Getting Started Guide, Commercial NIST Traceable Calibration with Certicate, Power Cable for the Destination Country, 3-year Warranty
General Accessories
External GPIB Accessory USB2-GPIB Soft Carrying Case WS3K-SOFTCASE Rack Mount Accessory WS3K-RACK
Multi-Instrument Options
MSO software option and 16 Channel Digital probe leadset WS3K-MSO MSO License (MS Probe Not Included) WS3K-MSO-LICENSE Function Generator Option WS3K-FG Spectrum Analyzer for WaveSurfer 3000z WS3K-SPECTRUM-1 Audiobus Trigger and Decode Option for I
and TDM CAN and LIN Trigger and Decode Option WS3K-AUTO CAN FD Trigger and Decode Option WS3K-CAN FDbus TD
2
I
C, SPI, UART and RS-232 Trigger and Decode Option WS3K-EMB FlexRay Trigger and Decode Option WS3K-FlexRaybus TD Power Analysis Option WS3K-PWR
2
S, LJ, RJ,
WS3K-Audiobus TD
Product Description Product Code
Probes
250 MHz Passive Probe 10:1, 10 M 500 MHz Passive Probe 10:1, 10 M 700 V, 15 MHz High-Voltage Differential Probe AP031 Power/Voltage Rail Probe. 4 GHz bandwidth,
1.2x attenuation, ±30V offset, ±800mV Browser for use with RP4030 RP4000-BROWSER 1,500 V, 120 MHz High-Voltage Differential Probe HVD3106A 1kV, 80 MHz High Voltage Differential Probe with 6m cable HVD3106A-6M 1kV, 120 MHz High Voltage Differential Probe
without tip Accessories 1,500 V, 25 MHz High-Voltage Differential Probe HVD3102A 1kV, 25 MHz High Voltage Differential Probe without
tip Accessories 2kV, 120 MHz High Voltage Differential Probe HVD3206A 2kV, 80 MHz High Voltage Differential Probe with 6m cable HVD3206A-6M 2kV, 400 MHz High Voltage Differential Probe HVD3220 6kV, 100 MHz High Voltage Differential Probe HVD3605A High Voltage Fiber Optic Probe, 150 MHz
(requires accessory tip) ±1V (1x) Tip Accessor
y for HVFO103 HVFO100-1X-TIP ±5V (5x) Tip Accessory for HVFO103 HVFO100-5X-TIP ±20V (20x) Tip Accessory for HVFO103 HVFO100-20X-TIP 30 A; 100 MHz Current Probe – AC/DC; 30 A 30 A; 100 MHz High Sensitivity Current Probe – AC/DC;
30 A
rms;
50 A
peak
Pulse 30 A; 50 MHz Current Probe – AC/DC; 30 A 30 A, 10 MHz Current Probe - AC/DC, 30 A rms, 50 A
3 meter cable 30 A; 50 MHz High Sensitivity Current Probe – AC/DC; 30 A
50 A
Pulse
peak
150 A; 10 MHz Current Probe – AC/DC; 150 A 150 A, 5 MHz Current Probe - AC/DC, 150 A rms, 500 A
Pulse, 6 meter cable 500 A; 2 MHz Current Probe – AC/DC; 500 A Deskew Calibration Source for CP031, CP030 and AP015 DCS025 500 MHz Differential Probe AP033
200 MHz, 3.5 pF, 1 MΩ Active Differential Probe, ±20 V,
60V common-mode
1 GHz, 1.0 pF, 1 MΩ Active Differential Probe, ±8 V,
10V common-mode
1.5 GHz, 1.0 pF, 1 MΩ Active Differential Probe, ±8 V,
10V common-mode
1 GHz, 0.9 pF, 1 MΩ High Impedance Active Probe ZS1000
1.5 GHz, 0.9 pF, 1 MΩ High Impedance Active Probe ZS1500
100:1 400 MHz 50 MΩ 1 kV High-voltage Probe HVP120
2 kV HV Probe, 6 kV overvoltage capability
500 MHz 60 V Common Mode Differential Probe. Includes standard set of leads and tips.
1 GHz 60 V Common Mode Differential Probe. Includes standard set of leads and tips.
Ω Ω
PP019 PP020
RP4030
HVD3106A-NOA
CC
HVD3102A-NOACC
rms;
50 A
Pulse CP031
peak
HVFO108
CP031A
50 A
rms;
rms;
rms;
Pulse CP030
peak
Pulse,
Peak
rms;
500 A
700 A
Pulse CP150
peak
Peak
Pulse CP500
peak
CP030-3M
CP150-6M
CP030A
ZD200
ZD1000
ZD1500
PPE6KV-A
DL05-HCM
DL10-HCM
Probe Adapters
TekProbe to ProBus Probe Adapter TPA10
Local sales oces are located throughout the world. Visit our website to nd the most convenient location.
© 2022 Teledyne LeCroy, Inc. All rights reserved. Specications, prices, availability, and delivery subject to change without notice. Product or brand names are trademarks or requested trademarks of their respective holders.
wavesurfer3000z_ds-20jan22
Loading...