Teledyne LeCroy Lecroy T3LCR1100 Quickstart

T3LCR1002, T3LCR1100, T3LCR1300
Precision LCR Meters
Quick Start Guide
5 Commonwealth Ave Woburn, MA 01801 Phone 781-665-1400 Toll Free 1-800-517-8431
This quick start guide contains proprietary information, which is protected by copyright. All rights are reserved. No part of this manual may be photocopied, reproduced or translated to another language without prior written consent of Teledyne LeCroy company.
The information in this quick start guide was correct at the time of printing. However, Teledyne LeCroy continues to improve products and reserves the rights to change specification, equipment, and maintenance procedures at any time without notice.
SAFETY INSTRUCTIONS
WARNING
Warning: Identifies conditions or practices that could result in injury or loss of life.
CAUTION
Caution: Identifies conditions or practices that could result in damage to the instrument or to other properties.
Safety Symbols
These safety symbols may appear in the quick start guide or on the instrument.
When you notice any of the unusual conditions listed below, immediately terminate operation and disconnect the power cable.
Please contact the Teledyne service center representative for repair of the instrument. If you continue to operate without repairing the instrument, there is a potential fire or shock hazard for operators.
The instrument is operating abnormally if:
The instrument emits abnormal noise, smell, smoke, or a spark­like light during the operation.
The instrument generates high temperature or electrical shock during operation.
The power cable, plug, or receptacle on the instrument is damaged.
Foreign substances or liquid has fallen into the instrument.
The following general safety precautions must be observed during all phases of operation, service, and repair of this instrument. Failure to comply with these precautions or with specific WARNINGS elsewhere in this manual may impair the protection provided by the equipment. In addition it violates safety standards of design, manufacture, and intended use of the instrument.
1
Disclaimer
Teledyne assumes no liability for the customer's failure to comply with these requirements.
Ground The Instrument
To avoid electric shock hazards, the instrument chassis and cabinet must be connected to a safety earth ground by the supplied power cable with earth blade.
DO NOT Operate In An Explosive Atmosphere
Do not operate the instrument in the presence of inflammable gasses or fumes. Operation of any electrical instrument in such an environment constitutes a definite safety hazard.
Keep Away From Live Circuits
Operating personnel must not remove instrument covers. Component replacement and internal adjustments must be made by qualified maintenance personnel. Do not replace components with the power cable connected. Under certain conditions, dangerous voltages may exist even with the power cable is removed. To avoid injuries, always disconnect the power and discharge the circuits before touching them.
DO NOT Service Or Adjust Alone
Do not attempt internal service or adjustment unless another person, capable of rendering first aid and resuscitation, is present.
DO NOT Substitute Parts Or Modify Instrument
Because of the danger of introducing additional hazards, do not install substitute parts or perform unauthorized modifications to the instrument.
Return the instrument to a Teledyne authorized service center for service and repair to ensure that safety features are maintained.
2
GETTING STARTED
Correction Function
OPEN/SHORT correction Eliminates measurement errors due to stray parasitic impedance in the test fixtures.
This chapter describes names and functions of the front panel, rear panel, and screen display and provides the basic procedures for operating the T3LCR series.
Overview
The Teledyne T3LCR series is a general-purpose LCR meter for incoming inspection of components, quality control, and laboratory use.
The T3LCR series is used for evaluating LCR components, materials, and semiconductor devices over a wide range of frequencies (10 Hz to 300 kHz) and test signal levels (10.00mV to
2.00V & 100.0uA to 20.00mA).
With its built-in comparator, the T3LCR series can output comparison/decision results for sorting components into a maximum of ten bins. Furthermore, by using the handler interface, the T3LCR
and a system controller to fully automate component testing, sorting, and quality- control data processing.
The list Meas function permits entry of up to 10 frequencies or test signal levels points to be automatically measured.
series can be easily combined with a component handler,
Main Features
Comparator Function (Sorting)
Bin sort The primary parameter can be sorted into BIN1- BIN9, AUX, OUT and HI/IN/LO for each of the primary measurement parameters.
The sequential mode or tolerance mode can be selected as the sorting mode.
3
Files
Up to 10 setup conditions can be written to/read from the built-in non-volatile memory.
Key Lock
The front panel keys can be locked.
RS-232
Complies with SCPI.
Front Panel
Description
1. LCD Display
2. Soft-key
3. Number Key
4. Cursor Key
5. Power Switch
6. Measure key
7. Setup Key
8. BNC Terminal
9. Trigger Key
10. ESC Key
11. USB Disk Port (USB-Host)
12. System Soft-key
Limit Setup Absolute value, deviation value, and % deviation value can be used for setup.
BIN count Countable from 0 to 999999
 

4

