Unauthorized duplication of Teledyne LeCroy documentation materials other than for
internal sales and distribution purposes is strictly prohibited. However, clients are
encouraged to distribute and duplicate Teledyne LeCroy documentation for their own
internal educational purposes.
WaveSurfer, WaveRunner, and Teledyne LeCroy are registered trademarks of Teledyne
LeCroy, Inc. Windows is a registered trademark of Microsoft Corporation. Other product
or brand names are trademarks or requested trademarks of their respective holders.
Information in this publication supersedes all earlier versions. Specifications are subject
to change without notice.
Warranty
Teledyne LeCroy warrants this oscilloscope accessory for normal use and operation
within specification for a period of one year from the date of shipment. Spare parts,
replacement parts and repairs are warranted for 90 days.
In exercising its warranty, Teledyne LeCroy, at its option, will either repair or replace any
assembly returned within its warranty period to the Customer Service Department or an
authorized service center. However, this will be done only if the product is determined
by Teledyne LeCroy’s examination to be defective due to workmanship or materials, and
the defect is not caused by misuse, neglect, accident, abnormal conditions of operation,
or damage resulting from attempted repair or modifications by a non-authorized service
facility.
The customer will be responsible for the transportation and insurance charges for the
return of products to the service facility. Teledyne LeCroy will return all products under
warranty with transportation charges prepaid.
This warranty replaces all other warranties, expressed or implied, including but not
limited to any implied warranty of merchantability, fitness or adequacy for any particular
purposes or use. Teledyne LeCroy shall not be liable for any special, incidental, or
consequential damages, whether in contract or otherwise.
922224-00 Rev A
January 2013
Page 4
PP011 Passive Probe
High Voltage, risk of electric shock.
CAUTION of potential damage to equipment, or WARNING of potential for
bodily injury. Attend to the accompanying information/product manual to
protect against personal injury or damage. Do not proceed until conditions
are fully understood and met.
DOUBLE INSULATION
PROTECTIVE (EARTH) TERMINAL
Safety Instructions
This section contains instructions that must be observed to keep this
oscilloscope accessory operating in a correct and safe condition. You are
required to follow generally accepted safety procedures in addition to the
precautions specified in this section. The overall safety of any system
incorporating this accessory is the responsibility of the assembler of the
system.
Symbols
These terms and symbols may appear on the probe body or in this manual to
alert you to important safety considerations.
Precautions
To avoid personal injury or damage to property, review and comply with the
following safety precautions. Use product only as specified.
Connect only to grounded instruments. Use only with compatible Teledyne
LeCroy oscilloscopes that have their BNC input connected to an earth ground. Do
not connect the probe reference lead to any point which is at a potential other
than earth ground.
Connect and disconnect properly. Connect probe to the oscilloscope before
connecting the probe to the test circuit. Disconnect the probe input and
reference lead from the test circuit before disconnecting the probe from the
oscilloscope. To avoid injury or death due to electric shock, do not connect or
disconnect probes or probe accessories while they are connected to a voltage
source.
2 922224-00 Rev A
Page 5
Operator’s Manual
Do not overload. To avoid electric shock or fire, do not apply any potential to
the probe leads that exceeds the maximum rating of the probe.
Comply with voltage derating curve. When measuring higher frequency signals,
comply with the Voltage vs. Frequency Derating Curve.
Observe all terminal ratings. To avoid electric shock or fire, observe all markings
on the oscilloscope before connecting. Consult the respective oscilloscope
product manual for further ratings information.
Do not remove probe casing. Removing the probe’s case or touching exposed
connections may result in electric shock.
Use only within operational environment listed. Do not use in wet or explosive
atmospheres. Keep product surfaces clean and dry.
Use only accessories compatible with the probe.
Handle with care. The probe tip is extremely sharp and may puncture skin or
cause other bodily injury if not handled properly.
Keep fingers behind the finger guard of probe body and accessories.
Do not operate with suspected failures. Before each use, inspect the probe and
accessories for any potential damage such as tears or other defects in the probe
body, cable jacket, accessories, etc. If any part is damaged, cease operation
immediately and sequester the probe from inadvertent use.
Operating Environment
The accessory is intended for indoor use and should be operated in a clean, dry
environment. Before using this product, ensure that its operating environment is
maintained within these parameters:
Temperature: Operating, 0° to 50° C; Non-operating, - 40° to 71° C
Humidity: 5% to 85% relative humidity (%RH) up to +30° C
5% to 65% RH above +30° C to 40° C
5% to 45% RH above 40° C
Altitude: Up to 2000 m (6540 ft)
922224-00 Rev A 3
Page 6
PP011 Passive Probe
Introduction
The PP011 is a miniature high impedance passive probe. Its high input resistance
and low capacitance make it ideal for general purpose probing of signals with
frequency content from DC through several hundred MHz. The PP011 has a large
selection of connection accessories, supplied standard with the probe and
available from Teledyne LeCroy as optional accessories.
The PP011 is designed for use with 600 MHz and higher Teledyne LeCroy
WaveSurfer oscilloscopes.
4 922224-00 Rev A
Page 7
Specifications
Attenuation 10 1%
Input Resistance 10 M1%
Input Capacitance 9.5 pF
Input Impedance (see plot on next page)
Compensation Range 10 – 20 pF
Bandwidth 500 MHz (-3 dB)
Maximum Input Voltage Measurement category I: 400 V rms,
1250 V transient overvoltage
(see voltage derating curve below)
Measurement category II: 300 V rms CAT II
Pollution Degree 2
* See Certifications for an explanation of ratings.
Operator’s Manual
Electrical Characteristics
Electrical Ratings*
General Characteristics
Operating Temperature 0o to +50o C
Storage Temperature -40o to +71o C
Altitude, Operating up to 2000 m (6560 ft)
Humidity 5% to 85% relative humidity (%RH) up to
+30° C 5% to 65% RH above +30° C to 40° C
5% to 45% RH above 40° C
Cable Length 2 m (6.6 ft)
Cable Length 1.3 m
Weight (probe only) 46 g
922224-00 Rev A 5
Page 8
PP011 Passive Probe
Max. VIN versus Frequency,
Measurement Category I
Typical Input Impedance
6 922224-00 Rev A
Page 9
Operator’s Manual
PK1-5MM-101
Sprung Hook
PK1-5MM-102
Standard Ground Lead
PK1-5MM-103
Adjustment Tool
PK1-5MM-104
Rigid Tip, 0.8 mm
PK1-5MM-105
Insulating Cap
PK1-5MM-106
Color Coding Rings (set)
(Not shown)
Instruction Manual
Protective Cap
Connectivity Accessories
Teledyne LeCroy provides 24 individual accessories for the PP011 probe, which
enable reliable connections to any physical requirement. In addition to those
provided with the standard probe, several optional varieties are available either
individually, or grouped in sets related to specific application needs.
The PK005A series of connectivity accessories are compatible with any Teledyne
LeCroy 5 mm PP011 series probe. Accessories are shown with the Teledyne
LeCroy part number followed by the description.
Standard Accessories
922224-00 Rev A 7
Page 10
PP011 Passive Probe
PK1-5MM-109
Spring Tip, 0.8 mm
PK1-5MM-124
Spring Tip, 0.38 mm
PK1-5MM-108
IC Cap, 2.54 mm
pitch
PK1-5MM-118
Ground Spring
PK1-5MM-111
Single Lead Adapter
PK1-5MM-112
Dual Lead Adapter
PK1-5MM-116
Adapter, 2 mm plug
PK1-5MM-117
Adapter, 4 mm plug
PK1-5MM-113
Pico Hook™
PK1-5MM-114Y
PK1-5MM-114G
Micro Clip, Long
PK1-5MM-115Y
PK1-5MM-115G
Micro Clip, Short
PK1-5MM-107
PCB Adapter
PK1-5MM-110
BNC Adapter
(For low voltage use only 42 Vpk AC + DC)
Optional Accessories
TIPS AND SPRINGS
INPUT ADAPTERS AND CLIPS
8 922224-00 Rev A
Page 11
Operator’s Manual
PK1-5MM-119
Ground Lead with mini clip
PK1-5MM-120
Ground Lead with 8 mm
socket
PK1-5MM-121
Ground Lead with 2 mm plug
PK1-5MM-122
Ground lead with 4 mm plug
PK1-5MM-123*
High Frequency Compensated Ground Lead
GROUND LEADS
*The PK1-5MM-123 High Frequency compensated ground lead allows operation with long ground lead with
minimum signal distortion.
PROBE CONNECTIVITY KITS
The following kits containing an assortment of probe connection accessories can
be ordered directly from Teledyne LeCroy. Refer to the illustrations on pages 4-6
for identification.
PKIT1-5MM-102 Basic Adapter Kit replaces the common standard accessories,
with 1 each of PK1-5MM-110, PK1-5MM-104, PK1-5MM-103, PK1-5MM-108,
PK1-5MM-117, PK1-5MM-101, PK1-5MM-102, PK1-5MM-118, PK1-5MM-123; 6
each of PK1-5MM-109; and 5 each of PK1-5MM-124.
PKIT1-5MM-101 Micro Clip Kit adapts the probe for use with 0.5 mm IC lead
clips. It contains 1 each of PK1-5MM-115Y, PK1-5MM-115G, PK1-5MM-114Y,
PK1-5MM-114G, PK1-5MM-111.
922224-00 Rev A 9
Page 12
PP011 Passive Probe
Probe connected using PCB Adapter
PC Board hole size and pattern
Use and Maintenance
This probe is a high quality, precision instrument. To maintain accuracy and
signal fidelity, mechanical shock should be avoided, as well as damage to the
cable through excessive bending.
To achieve the small 2.5 mm tip size, the input tip diameter is narrower than
those in larger probes. Avoid placing excessive force sideways on the tip.
Should the tip become damaged, it may be replaced by the user using the
procedure listed on the last page.
Other maintenance and component replacement should be referred to qualified
personnel.
Cleaning
The outside of the probe should cleaned with a soft cloth dampened with either
deionized / distilled water or isopropyl alcohol. Allow the surface to dry
completely before returning the probe to service. Never immerse the probe in
any liquid.
Use of PCB Adapter
The PCB adapter (Teledyne LeCroy P/N PK1-5MM-107) is intended to be
designed into and permanently installed in circuit boards to provide a reliable,
high frequency test point which eliminates the need to hand hold the probe.
10 922224-00 Rev A
Page 13
Operator’s Manual
Undershoot
Overshoot
Correct adjustment
Typical optimum HF
adjustment
Probe Compensation
Proper compensation of the probe is required to assure good amplitude
accuracy in the dynamic portions of the waveform being measured. LF
compensation matches the probe to differences in oscilloscope input
capacitance. The LF compensation should always be checked and adjusted as
needed when first connecting a passive probe to the oscilloscope input. HF
compensation matches time constants within the probe to compensate for
normal component tolerances. It is typically not necessary to adjust HF
compensation unless the probe is being used with an oscilloscope with large
differences in input characteristics than the oscilloscope model it was designed
for.
LF compensation is performed by connecting the input of the probe to a low
frequency square wave, such as the oscilloscope calibrator signal set to 1 kHz.
The compensation is adjusted by rotating the adjustment accessible through the
small hole in the center of the housing near the BNC connector. Use the tool
supplied with the probe for this adjustment.
Should HF compensation be required, access the
adjustments by sliding the black plastic cover off the
compensation housing near the BNC con-nector. A
pulse generator with low overshoot and a 300 ps
risetime is the required signal source, along with a
set of attenuators. The probe must be connected to
a terminated probe tip to BNC adapter.
Some overshoot and ring will be present at some
settings of V/Div. Adjust both trimmers for the
overall best response on all ranges.
922224-00 Rev A 11
Page 14
PP011 Passive Probe
To remove tip, grip the spring-loaded
portion of the tip beyond the outer sleeve
and pull straight out.
Do not apply pliers to the plastic insulator.
Tip Selection and Exchange
The PP011 probe is supplied with two tip styles. The spring tip, which is installed
when the probe is shipped, combines a sharp point with on-axis compliance. This
provides reliable connection under a wide range of physical interconnect
situtations. A rigid tip is also supplied. While lacking the on-axis compliance
feature of the spring tip, the rigid tip has a larger diameter and is more robust
when exposed to physical stress at the tip. Select the proper tip for your
application needs.
To change the tip or replace it when damaged, carefully grip the outer most
portion of tip and pull straight out, along the axis of the probe, using needle
nose pliers. Do not attempt to grip the plastic insulator with pliers when
removing the tip, as this will squeeze the tip, which will make it difficult or
impossible to remove. Do not grip the outer gold plated tube which the tip slides
into. With the tip removed, align the replacement tip with the hole and begin
the insertion with the pliers. To fully seat the tip, placie the probe against a hard
surface and gently apply pressure.
12 922224-00 Rev A
Page 15
Operator’s Manual
Certifications
This section certifies the probe’ Safety and Environmental compliance.
EC Declaration of Conformity - Safety
The probe meets intent of EC Directive 2006/95/EC for Product Safety.
Compliance was demonstrated to the following specifications as listed in the
Official Journal of the European Communities:
EN 61010-031/A1:2008 Safety requirements for electrical equipment for
measurement, control, and laboratory use – Part 031: Safety requirements for
hand-held probe assemblies for electrical measurement and test.
Measurement Category I (CAT I), measurements performed on circuits
not directly connected to a mains supply.
Measurement Category II (CAT II), measurements performed on circuits
directly connected to the low-voltage installation.
Pollution Degree 2, operating environment where normally only dry
non-conductive pollution occurs. Conductivity caused by temporary
condensation should be expected.
Environmental Compliance
END-OF-LIFE HANDLING
The probe is marked with this symbol to indicate that it complies
with the applicable European Union requirements to Directives
2002/96/EC and 2006/66/EC on Waste Electrical and Electronic
Equipment (WEEE) and Batteries.
The probe is subject to disposal and recycling regulations that vary
by country and region. Many countries prohibit the disposal of
waste electronic equipment in standard waste receptacles. For
more information about proper disposal and recycling of your
This probe has been classified as Industrial Monitoring and Control Equipment
and is outside the scope of the 2011/65/EU RoHS Directive until 22 July 2017
(per Article 4, Paragraph 3).
922224-00 Rev A 13
Page 16
PP011 Passive Probe
Teledyne LeCroy Service Centers
United States and Canada -
World Wide Corporate Office
China
Teledyne LeCroy Corporation Beijing
Rm. 2001 - Office; Rm. 2002 - Service Center
Unit A, Horizon Plaza
No. 6, Zhichun Road, Haidian District
Beijing 100088, China
Ph: ++86 10 8280 0318 / 0319 / 0320
FAX:++86 10 8280 0316
Service:
Rm. 2002
Ph: ++86 10 8280 0245
Korea
Teledyne LeCroy Korea
10th fl.Ildong Bldg.
968-5 Daechi-dong, Gangnam-gu
Seoul 135-280, Korea
Ph: ++ 82 2 3452 0400
FAX: ++ 82 2 3452 0490
Taiwan
LeColn Technology Co Ltd.
Far East Century Park, C3, 9F
No. 2, Chien-8th Road,
Chung-Ho Dist., New Taipei City, Taiwan
Ph: ++ 886 2 8226 1366
FAX: ++ 886 2 8226 1368
Japan
Teledyne LeCroy Japan
Hobunsya Funchu Bldg, 3F
3-11-5, Midori-cho, Fuchu-Shi
Tokyo 183-0006, Japan
Ph: ++ 81 4 2402 9400
FAX: ++ 81 4 2402 9586
teledynelecroy.com/japan
Contact Teledyne LeCroy
14 922224-00 Rev A
Page 17
Operator’s Manual
922224-00 Rev A 15
Page 18
PP011 Passive Probe
16 922224-00 Rev A
Page 19
Page 20