Teledyne CP030 User Manual

Instruction Manual
CP030 Current Probe
Instruction Manual
January 2013
700 Chestnut Ridge Road Chestnut Ridge, NY, 10977-6499 Tel: (845) 425-2000 Fax: (845) 578 5985 teledynelecroy.com
© 2013 Teledyne LeCroy, Inc. All rights reserved.
Unauthorized duplication of Teledyne LeCroy documentation materials other than for internal sales and distribution purposes is strictly prohibited. However, clients are encouraged to distribute and duplicate Teledyne LeCroy documentation for their own internal educational purposes.
WaveSurfer, WaveRunner, WavePro and Teledyne LeCroy are registered trademarks of Teledyne LeCroy, Inc.
Windows is a registered trademark of Microsoft Corporation. Other product or brand names are trademarks or requested trademarks of their respective holders. Information in this publication supersedes all earlier versions. Specifications are subject to change without notice.
Warranty
Teledyne Lecroy warrants this oscilloscope accessory for normal use and operation within specification for a period of one year from the date of shipment. Spare parts, replacement parts and repairs are warranted for 90 days.
In exercising its warranty, Teledyne Lecroy, at its option, will either repair or replace any assembly returned within its warranty period to the Customer Service Department or an authorized service center. However, this will be done only if the product is determined by Teledyne Lecroy’s examination to be defective due to workmanship or materials, and the defect is not caused by misuse, neglect, accident, abnormal conditions of operation, or damage resulting from attempted repair or modifications by a non-authorized service facility.
The customer will be responsible for the transportation and insurance charges for the return of products to the service facility. Teledyne Lecroy will return all products under warranty with transportation charges prepaid.
This warranty replaces all other warranties, expressed or implied, including but not limited to any implied warranty of merchantability, fitness or adequacy for any particular purposes or use. Teledyne Lecroy shall not be liable for any special, incidental, or consequential damages, whether in contract or otherwise.
922173-00 Rev A
Instruction Manual
TABLE OF CONTENTS
Safety Instructions ..........................................................................................................................................................1
Symbols .................................................................................................................................................................... 1
Precautions ............................................................................................................................................................... 1
Operating Environment ............................................................................................................................................. 2
Overview ........................................................................................................................................................................3
Description ................................................................................................................................................................ 3
Key Features ............................................................................................................................................................. 3
Accessories ............................................................................................................................................................... 3
Operation ........................................................................................................................................................................4
Precautions ............................................................................................................................................................... 4
Connecting the Probe to the Test Instrument ............................................................................................................ 4
Connecting the Probe to the Test Circuit .................................................................................................................. 4
Operation with a Teledyne LeCroy Oscilloscope ...................................................................................................... 5
Bandwidth Limit ......................................................................................................................................................... 5
Auto Zero .................................................................................................................................................................. 5
Degauss Probe ......................................................................................................................................................... 5
Care and Maintenance ................................................................................................ ...................................................6
Cleaning .................................................................................................................................................................... 6
Calibration Interval .................................................................................................................................................... 6
Service Strategy ........................................................................................................................................................ 6
Troubleshooting ........................................................................................................................................................ 6
Returning a Defective Probe ..........................................................................................................................................7
Performance Verification ................................................................................................................................................8
Test Equipment Required ......................................................................................................................................... 8
Preliminary Procedure............................................................................................................................................... 9
Functional Check ...................................................................................................................................................... 9
Check LF Accuracy ................................................................................................................................................. 10
922173-00 Rev A i
CP030 Current Probe
Adjustment Procedure .................................................................................................................................................. 11
Test Equipment Required ....................................................................................................................................... 11
Preliminary Procedure............................................................................................................................................. 12
Adjust LF Accuracy ................................................................................................................................ ................. 12
Specifications ............................................................................................................................................................... 14
Nominal Characteristics .......................................................................................................................................... 14
Warranted Characteristics ....................................................................................................................................... 14
Typical Characteristics ............................................................................................................................................ 14
Environmental Characteristics ................................................................................................................................ 15
Physical Characteristics .......................................................................................................................................... 15
Graphs.......................................................................................................................................................................... 16
Certifications ................................................................................................................................................................. 17
EMC Compliance .................................................................................................................................................... 17
EC Declaration of Conformity - EMC .................................................................................................................. 17
Australia & New Zealand Declaration of ConformityEMC ............................................................................... 17
Safety Compliance .................................................................................................................................................. 18
EC Declaration of Conformity – Low Voltage ...................................................................................................... 18
Environmental Compliance ..................................................................................................................................... 18
End-Of-Life Handling .......................................................................................................................................... 18
Restriction of Hazardous Substances (RoHS) .................................................................................................... 18
Contact Teledyne LeCroy ............................................................................................................................................. 19
Appendix A ................................................................................................................................................................... 20
Performance Verification Test Record .................................................................................................................... 20
Equipment Used ..................................................................................................................................................... 20
CP030 Test Record ................................................................................................................................................ 20
ii 922173-00 Rev A
Instruction Manual
WARNING. High Voltage, risk of electric shock.
CAUTION. Potential for damage to probe or instrument it is connected to. Attend to the accompanying
information to protect against personal injury or damage. Do not proceed until conditions are fully understood and met.
ELECTROSTATIC DISCHARGE (ESD) HAZARD. The probe is susceptible to damage if anti-static measures are not taken.
DOUBLE INSULATION
PROTECTIVE (EARTH) TERMINAL
Safety Instructions
This section contains instructions that must be observed to keep this oscilloscope accessory operating in a correct and safe condition. You are required to follow generally accepted safety procedures in addition to the precautions specified in this section.
The overall safety of any system incorporating this accessory is the responsibility of the assembler of the system.
Symbols
These symbols may appear on the probe body or in this manual to alert you to important safety considerations.
Precautions
Connect and disconnect properly. Connect probe to the measurement instrument before
connecting the test leads to a circuit/signal being tested.
Use only within operational environment listed. Do not use in wet or explosive atmospheres. Use indoors only. Keep product surfaces clean and dry. Be careful with sharp tips. The tips may cause bodily injury if not handled properly. Do not operate with suspected failures. Do not use the probe if any part is damaged. Cease
operation immediately and sequester the probe from inadvertent use.
Be careful not to damage the insulation surface when making measurements.
922173-00 Rev A 1
CP030 Current Probe
Never install or remove the probe on bare conductors which are energized. The transformer
core and shield are grounded but not insulated and may contact the conductor when the locking lever is open.
To avoid short circuits and accidents that could result in injury or death, use the CP031 current
probe only with conductors carrying 300 V or less.
To prevent short circuits and electric shock when conductors being measured carry less than
300 V but more than the safe voltage level (SELV-E) make sure that the conductors to be measured are insulated with material conforming to:
o Overvoltage Category I, basic insulation requirement for working voltage of 300 V o Pollution degree 2
Operating Environment
The accessory is intended for indoor use and should be operated in a clean, dry environment. Before using this product, ensure that its operating environment is maintained within these parameters:
Temperature: 0° to 40° C.
Humidity: ≤ 80% relative humidity (non-condensing)
Altitude: up to 2000 m (6562 feet)
2 922173-00 Rev A
Instruction Manual
Overview
Description
The CP030 uses a combination of Hall effect and transformer technology which enables measurements to be made on DC, AC and impulse currents. It has a 50 MHz bandwidth and is designed to measure continuous currents up to 30 Amp.
The probe can be used with a WaveSurfer, WaveRunner 6000, or WavePro 7000 series oscilloscope with firmware 4.3.0.0 or higher. With the ProBus interface, the CP030 becomes an integral part of the oscilloscope. The bandwidth limit, auto zero and degauss functions are all controlled from the oscilloscope’s graphical user interface. The oscilloscope provides power to the probe, so no external power supply is needed.
Key Features
• Highly accurate current measurements
• Easy current measurements
• Wide bandwidth
• Compact
• Over-current protected
Accessories
Certificate of Calibration
Instruction Manual CP030-OM-E
922173-00 Rev A 3
Loading...
+ 19 hidden pages