TeleDart RD406, RD706 User Manual

TeleDart GmbH & Co. KG, Obere Heide 8, 67368 Westheim, Germany
TeleDart Injection Pistol RD406 / Injection Rifle RD706
1. INTRODUCTION
Dear Customer,
Be sure that we stand with all our energy and passion behind our products and that your decision for TeleDart was the right one. We look forward to assisting you with words and deeds during a long period of time and to offering you the service you can await for a quality product. Our conviction and our confidence in our products allow us to guarantee you the function of your applicator for the next 20 years.
Please study the following operator’s manual carefully and follow all our directions and instructions. Then you will be sure to do your remote injections safely and without problems.
We wish you always a very successful working.
The Team of TeleDart
Pressure table for the TeleDart® applicator RD_________
Dear customer,
Thank you for having chosen a TeleDart® applicator.
This applicator has been tested in a closed area.
Please note that this is only a guideline, which may differ from your own shooting results as wind and weather conditions as well as the shooting skills of the user can change these results considerably.
TeleDart GmbH & Co. KG
Additional optical equipment:
none OP1-Telescopic sight OP2-RedDot
Barrel Dart syringe Distance Pressure
15 m bar 15 m bar 15 m bar
TeleDart GmbH & Co. KG, Obere Heide 8, 67368 Westheim, Germany
TeleDart Dart Gun RD706
Distance up to 70 m (76 yds)
Barrel
Cartridge holder for CO2
resp. adaptor for airpump
Barrel screw
Pressure supply
Trigger
Sight
Trigger safety
Prismatic rail for optics
Pressure gauge
Safety valve
Dart syringe loading
Shaft
Cheek piece (adjustable)
Shoulder support (adjustable)
Technical Data GUN RD706
Weight approx. 3,3 kg Overall length with barrel 113 cm Material aluminium/stainless steel/steel Barrels/Syringe volumes interchangeable barrel system with quick connection coupling
calibre 11 mm (1 - 5 ccs/ml) calibre 13 mm (5 - 20 ccs/ml) calibre 16 mm (1 - 20 ccs/ml)
Short barrel available Maximum range 130 m Effective range (with standard barrel calibre 11 mm) 60 - 70 m (depending on dart sizes) Standard sight back sight/front sight Pressure build-up CO2 cartridge or airpump Pressure control continuous (0 - 16 bar) Safety striker yes (rotary knob safeguard) Safety valve yes Pressure relief valve yes Kinetic energy > 7,5 joules
Note: If using the 16 mm barrel the double stabiliser GBST16 (plastic stabiliser BST16 combined with woolen stabiliser GBST) is necessary to get the best trajectory.
TeleDart GmbH & Co. KG, Obere Heide 8, 67368 Westheim, Germany
TeleDart Pistol RD406
Distance : up to 40 m
Barrel screw
Barrel
Cartridge holder for CO²-device or adapter for footpump
Pressure supply
Trigger
Standard sight
Prismatic rail for optics
Dart syringe loading
Pressure gauge
Pistol grip and pressure chamber
Trigger safety
Safety valve
Technical Data PISTOL RD406
Weight approx. 2,1 kg Overall length with barrel 86 cm Material aluminium/ steel Barrels/Syringe volumes interchangeable barrel system with quick connection coupling
calibre 11 mm (1 - 5 ccs/ml) calibre 13 mm (5 - 20 ccs/ml) calibre 16 mm (1 - 20 ccs/ml)
Short barrel available Effective range (with standard barrel calibre 11 mm) 40 m (depending on dart sizes) Standard sight back sight/front sight Pressure build-up CO2 cartridge (16 bar) or airpump (11 bar) Pressure control continuous (0 - 10 bar) Safety striker yes (rotary knob safeguard) Safety valve yes Pressure relief valve yes Kinetic energy > 7,5 joules
Note: If using the 16 mm barrel the spezial stabiliser GBST16 (plastic stabiliser BST16 combined with woolen stabiliser GBST) is necessary to get the best trajectory.
TeleDart GmbH & Co. KG, Obere Heide 8, 67368 Westheim, Germany
2. Delivery
Please check upon receipt of our delivery, if your consignment is :
complete corresponds to the ordered equipment undamaged
Please inform us immediately , latest 48 hours after receipt of goods if you have any damage by sending us a letter/fax or E-mail.Our service team will immediately handle your claim.
Safety advices:
Always point the applicator in a safe direction. Never point at other people even if your applicator is not loaded.
Always keep your applicator with the barrel down to the ground.
Keep your applicator on safe, until you intend to shoot.
Be aware that the applicator has a danger zone of almost 500 meters. Be sure that no other persons are inside this area and that there are no public alleys, streets or squares.
Collect all used darts and part of darts after use, even if they are empty or damaged.
Avoid that children and other unauthorized individuals enter into possession of darts or part of darts.
Clean darts and part of darts contamined with drugs before disposing them.
Never use drugs or alcohol while handling this product.
Never use our applicators with pure oxygen (e.g. oxygen cartridges)!
Of course, all regulations applicable in your country with regard of the handling of weapons as well as animal protection and welfare are valid. Follow strictly the all safety advices of the drug producer.
Noticable damages For noticable damages, which are caused by improper handling of the applicator or
by other extraneous causes the use of the applicator must be stopped immediately. In such case first the barrel and second the dart must be removed and the applicator completely depressurized. This happens by careful removal of the Co2-cartridge or airpump connector first and is followed by the complete depressurizing of the pressure chamber. For further instructions please contact your dealer or us directly.
Please follow all safety advices we give you in this operator’s manual.
TeleDart GmbH & Co. KG, Obere Heide 8, 67368 Westheim, Germany
3. Handling and use
First use
Make yourself familiar with all operation elements of your applicator before you attempt to test the applicator and to go into practice.
TeleDart Guns have varying settings to allow you to adopt the applicator to your individual requirements.
Before shipment, we test all TeleDart applicators at a distance of 15 m (16.41 yds) using a TeleDart Dart Syringe (TD03-11/ TD05-13/TD03-16).
For your training we recommed to use the supplied traing darts. For training purposes it is not necessary to pressurize the dart syringe. If you have to work with other dart volumes please proceed in the same way. Note all pressure values in the pressure table which is part of your manual.
Assembling
Slide-in the barrel as far as it goes. Take care that the sight is on your right hand side. As soon as the barrel has reached its position, turn the barrel a quarter (90°) to the left until the guiding pin situated at the barrel retainer ring locks.
Individual Adjustments (gun)
Adopt the cheek piece and the shoulder support at a position at which you can shoot comfortably.
Inserting of the CO²-cartridge
Unscrew the cartridge holder and insert a CO²-cartridge. Tighten up the cartridge holder until the cartridges is tapped.
Only replace open cartridges if they are completely empty. Further all safety advices marked on the packing of the CO²-cartridges are valid. TeleDart does not take any liability for damages and injuries caused by improper handling of CO²-cartridges.
Safety
Check if the safety device of the trigger is on safe. The turning knob must be turned to the upper position (Pos. “S”).
Pressurizing
Airpump:
The pressure regulation knob must be in “0”- Position. Latch the hose of the airpump with the hose- connector. To unlatch the airpump the locking sleeve of the hose connector has to be pushed back until the hose unlatches.
CO2: The applicator is pressured if you turn the pressure regulation knob maxium one quarter (90°) in direction of the „+“-position. Observe the manometer and release the
TeleDart GmbH & Co. KG, Obere Heide 8, 67368 Westheim, Germany
knob when you have got the desired pressure. The pressure regulation knob returns automatically to the 0-position.
If you have got too much pressure, you can correct this easily. Just turn the pressure regulation knob in direction of the “-“ position until you have got the desired pressure. The pressure regulation knob does not return automatically to the 0-position if you release pressure. It has to be turned back by hand.
Pistol and gun have both a safety valve which opens automatically if you exceed the allowed maximum pressure (pistol 10 bar, gun 16 bar).
We want to point out that a manipulation of the safety valve immediately ceases our guarantee and that we do not assume any liability for damages of persons or material.
The safety valve is engineered to protect your applicator from damages caused by dangerous overpressure. The exceeding of the particular maximum pressure into the red marked area of the manometer can cause damages to your applicator. Damages to material, which are proven to be caused by deliberate exceeding of the maximum pressure ceases our guarantee!
We want to point out that also a manipulation of the safety valve immediately ceases our guarantee and in this case we do not assume any liability for damages to persons or material.
Loading of the dart syringe
Unscrew the loading screw and insert the syringe into the barrel from behind. Push the dart syringe the inside barrel using the positioning pin situated at the loading screw and screw it again.
The shooting
The applicator is now ready for shooting. The safety can now be activated. Turn the turning knob of the safety into the “F”- position. Now fix your aim. The trigger has a trigger pressure point and allows a precise shooting.
Immediately after shooting put back the applicator on safe - turn knob of the safety to the position “S”.
4. Care
You can clean the applicator with a moist cloth if the applicator gets dirty. Never use chemical cleaners.
Check if there is dirt inside the barrel. If necessary brush it dry with the cleaning tool. Grease the barrel inside to avoid rust.
5. Maintenance
Special maintenance is not necessary.
TeleDart GmbH & Co. KG, Obere Heide 8, 67368 Westheim, Germany
6. Storage
For storage and transportation all legal requirements must be complied with.
Always store the applicator at a dry place. CO²-cartridges can remain in the applicator.
If you store the applicator, the pressure regulation knob must be in the “-“-position to avoid an unintended pressure built-up.
Please check the function of your applicator if you have not used it for a longer time.
7. Special equipment
Here following please find a summary of our special equipment for your applicator:
Telescopic sight OP1 Red Dot sight OP2 Laser rangefinder RF Adaptor for cartridges 45gr Airpump FP Additional barrel 11mm (for 1-5cc syringes) Additional barrel 13mm (for 5-20cc syringes) Additional barrel 16mm (for 1-20cc syringes)
----------------------------------
TeleDart GmbH & Co. KG
TeleDart GmbH & Co. KG, Obere Heide 8, 67368 Westheim, Germany
Dear Customer
TeleDart ® Guarantee and Warranty Conditions (E)
We would like to thank you for your confidence in buying this German quality product of TeleDart ®. Our applicators pass several quality controls before being delivered to the final user to be sure they will fulfill the demands we guarantee you here as follows.
In addition to your legal rights, TeleDart ® guarantees:
1. For this product we give you a function guarantee of 20 years. The guarantee begins on the day of purchase of the final user.
2. Should the product show defects within the guarantee period, it will be repaired by Teledart ®.
3. Under the following rules we repair or replace damages or defaults of the product, which are proven to be caused by a material or manufacturing default.
4. Should you make a claim, please contact your TeleDart ® specialist dealer or us directly. Addresses can be found in the operation manual or on our internet site: www.teledart.com. The guarantee ends immediately if repairs or any manipulation of the product are made by none authorized persons or if you use spares, change parts or add accessories which are not of TeleDart’s original production and which then cause a damage.
5. Products for which you make a claim have to be send or given over to the seller or to a TeleDart ® specialist dealer. You must insure the dispatch or bear the costs for any loss or damage incurred and for the transport costs.
6. If you make a guarantee claim, please add the fully completed guarantee documents as well as a proof of the original purchase within the guarantee period for your specialist dealer. The guarantee claim must clearly illustrate the complaint, presuming that it is based of a specific defect demonstrated by facts and when the defect occurred. Further, the complete serial number of the applicator must be readable.
7. A guarantee claim will not be accepted for damages, which are irrelevant for the value or the use of the applicator, which are caused by irregular environmental conditions, unprofessional use or use which is not in accordance with regulations. If the points in the user and maintenance manual are not observed a guarantee claim will not be accepted.
8. Should the applicator be used in another country than the country it had been developed and produced in, it may be that some technical changes are necessary to adopt the applicator to the technical resp. security norms of this country. These changes are not caused by material or manufacturing default and are not covered by this guarantee. Costs for such changes or damages this may cause are not reimbursed.
9. The guarantee is a product guarantee and can be claimed during the guarantee period by any person who has purchased the product in a legal way. The legal right of the buyer following the national legally applicable rights, resp. the rights of the buyer as a part of the purchase contract as well as other rights are not affected by this guarantee. As far as the national law does not require other, the claims are restricted to the points named in this guarantee. TeleDart GmbH & Co.KG and all specialist dealers are not liable for indirect resp. subsequently lost or injuries of persons or animals or for the lost of dart syringes, needles or drugs.
10. Guarantee claims do not extend the guarantee period nor do they lead to a new guarantee period. The guarantee period for all built-in spare parts finishes at the moment when the guarantee for the complete applicator finishes. In case of a replacement TeleDart ® can determine a new time of guarantee which can be restricted under consideration of the time of use of the replaced applicator.
11. We do not assume liability for further or other claims, especially for those caused by damages which are not created by the applicator– if such a claim is not mandatory law.
These guarantee rules are valid after 2006-12-01.