Be sure that we stand with all our energy and passion behind our products and that your
decision for TeleDart was the right one. We look forward to assisting you with words and
deeds during a long period of time and to offering you the service you can await for a
quality product. Our conviction and our confidence in our products allow us to guarantee
you the function of your applicator for the next 20 years.
Please study the following operator’s manual carefully and follow all our directions and
instructions. Then you will be sure to do your remote injections safely and without
problems.
We wish you always a very successful working.
The Team of TeleDart
Pressure table for the TeleDart® applicatorRD_________
Dear customer,
Thank you for having chosen a TeleDart® applicator.
This applicator has been tested in a
closed area.
Please note that this is only a
guideline, which may differ from your
own shooting results as wind and
weather conditions as well as the
shooting skills of the user can change
these results considerably.
Weight approx. 3,3 kg
Overall length with barrel 113 cm
Material aluminium/stainless steel/steel
Barrels/Syringe volumes interchangeable barrel system with quick connection coupling
calibre 11 mm (1 - 5 ccs/ml)
calibre 13 mm (5 - 20 ccs/ml)
calibre 16 mm (1 - 20 ccs/ml)
Short barrel available
Maximum range 130 m
Effective range (with standard barrel calibre 11 mm) 60 - 70 m (depending on dart sizes)
Standard sight back sight/front sight
Pressure build-up CO2 cartridge or airpump
Pressure control continuous (0 - 16 bar)
Safety striker yes (rotary knob safeguard)
Safety valve yes
Pressure relief valve yes
Kinetic energy > 7,5 joules
Note:
If using the 16 mm barrel the double stabiliser GBST16 (plastic stabiliser BST16 combined with woolen stabiliser GBST)
is necessary to get the best trajectory.
Cartridge holder for
CO²-device or
adapter for
footpump
Pressure supply
Trigger
Standard sight
Prismatic rail for optics
Dart syringe loading
Pressure gauge
Pistol grip and
pressure chamber
Trigger safety
Safety valve
Technical Data PISTOL RD406
Weight approx. 2,1 kg
Overall length with barrel 86 cm
Material aluminium/ steel
Barrels/Syringe volumes interchangeable barrel system with quick connection coupling
calibre 11 mm (1 - 5 ccs/ml)
calibre 13 mm (5 - 20 ccs/ml)
calibre 16 mm (1 - 20 ccs/ml)
Short barrel available
Effective range (with standard barrel calibre 11 mm) 40 m (depending on dart sizes)
Standard sight back sight/front sight
Pressure build-up CO2 cartridge (16 bar) or airpump (11 bar)
Pressure control continuous (0 - 10 bar)
Safety striker yes (rotary knob safeguard)
Safety valve yes
Pressure relief valve yes
Kinetic energy > 7,5 joules
Note:
If using the 16 mm barrel the spezial stabiliser GBST16 (plastic stabiliser BST16 combined with woolen stabiliser GBST)
is necessary to get the best trajectory.
Please check upon receipt of our delivery, if your consignment is :
complete
corresponds to the ordered equipment
undamaged
Please inform us immediately , latest 48 hours after receipt of goods if you have any
damage by sending us a letter/fax or E-mail.Our service team will immediately handle your
claim.
Safety advices:
Always point the applicator in a safe direction. Never point at other people even if
your applicator is not loaded.
Always keep your applicator with the barrel down to the ground.
Keep your applicator on safe, until you intend to shoot.
Be aware that the applicator has a danger zone of almost 500 meters. Be sure that
no other persons are inside this area and that there are no public alleys, streets or
squares.
Collect all used darts and part of darts after use, even if they are empty or damaged.
Avoid that children and other unauthorized individuals enter into possession of
darts or part of darts.
Clean darts and part of darts contamined with drugs before disposing them.
Never use drugs or alcohol while handling this product.
Never use our applicators with pure oxygen (e.g. oxygen cartridges)!
Of course, all regulations applicable in your country with regard of the handling of
weapons as well as animal protection and welfare are valid. Follow strictly the all
safety advices of the drug producer.
Noticable damages
For noticable damages, which are caused by improper handling of the applicator or
by other extraneous causes the use of the applicator must be stopped immediately.
In such case first the barrel and second the dart must be removed and the applicator
completely depressurized. This happens by careful removal of the Co2-cartridge or
airpump connector first and is followed by the complete depressurizing of the
pressure chamber. For further instructions please contact your dealer or us directly.
Please follow all safety advices we give you in this operator’s manual.
Make yourself familiar with all operation elements of your applicator before you attempt
to test the applicator and to go into practice.
TeleDart Guns have varying settings to allow you to adopt the applicator to your
individual requirements.
Before shipment, we test all TeleDart applicators at a distance of 15 m (16.41 yds)
using a TeleDart Dart Syringe (TD03-11/ TD05-13/TD03-16).
For your training we recommed to use the supplied traing darts. For training purposes
it is not necessary to pressurize the dart syringe. If you have to work with other dart
volumes please proceed in the same way. Note all pressure values in the pressure
table which is part of your manual.
Assembling
Slide-in the barrel as far as it goes. Take care that the sight is on your right hand side.
As soon as the barrel has reached its position, turn the barrel a quarter (90°) to the left
until the guiding pin situated at the barrel retainer ring locks.
•Individual Adjustments (gun)
Adopt the cheek piece and the shoulder support at a position at which you can shoot
comfortably.
• Inserting of the CO²-cartridge
Unscrew the cartridge holder and insert a CO²-cartridge. Tighten up the cartridge
holder until the cartridges is tapped.
Only replace open cartridges if they are completely empty. Further all safety advices
marked on the packing of the CO²-cartridges are valid. TeleDart does not take any
liability for damages and injuries caused by improper handling of CO²-cartridges.
• Safety
Check if the safety device of the trigger is on safe. The turning knob must be turned to
the upper position (Pos. “S”).
• Pressurizing
Airpump:
The pressure regulation knob must be in “0”- Position. Latch the hose of the airpump
with the hose- connector. To unlatch the airpump the locking sleeve of the hose
connector has to be pushed back until the hose unlatches.
CO2:
The applicator is pressured if you turn the pressure regulation knob maxium one
quarter (90°) in direction of the „+“-position. Observe the manometer and release the
knob when you have got the desired pressure. The pressure regulation knob returns
automatically to the 0-position.
If you have got too much pressure, you can correct this easily. Just turn the pressure
regulation knob in direction of the “-“ position until you have got the desired pressure.
The pressure regulation knob does not return automatically to the 0-position if you
release pressure. It has to be turned back by hand.
Pistol and gun have both a safety valve which opens automatically if you exceed the
allowed maximum pressure (pistol 10 bar, gun 16 bar).
We want to point out that a manipulation of the safety valve immediately ceases our
guarantee and that we do not assume any liability for damages of persons or material.
The safety valve is engineered to protect your applicator from damages caused
by dangerous overpressure. The exceeding of the particular maximum pressure
into the red marked area of the manometer can cause damages to your
applicator. Damages to material, which are proven to be caused by deliberate
exceeding of the maximum pressure ceases our guarantee!
We want to point out that also a manipulation of the safety valve immediately
ceases our guarantee and in this case we do not assume any liability for
damages to persons or material.
• Loading of the dart syringe
Unscrew the loading screw and insert the syringe into the barrel from behind.
Push the dart syringe the inside barrel using the positioning pin situated at the loading
screw and screw it again.
• The shooting
The applicator is now ready for shooting. The safety can now be activated.
Turn the turning knob of the safety into the “F”- position. Now fix your aim.
The trigger has a trigger pressure point and allows a precise shooting.
Immediately after shooting put back the applicator on safe - turn knob of the safety to
the position “S”.
4.Care
You can clean the applicator with a moist cloth if the applicator gets dirty.
Never use chemical cleaners.
Check if there is dirt inside the barrel. If necessary brush it dry with the cleaning tool.
Grease the barrel inside to avoid rust.
We would like to thank you for your confidence in buying this German quality product of TeleDart®. Our
applicators pass several quality controls before being delivered to the final user to be sure they will fulfill the
demands we guarantee you here as follows.
In addition to your legal rights, TeleDart® guarantees:
1. For this product we give you a function guarantee of 20 years. The guarantee begins on the day of
purchase of the final user.
2. Should the product show defects within the guarantee period, it will be repaired by Teledart ®.
3. Under the following rules we repair or replace damages or defaults of the product, which are proven to be
caused by a material or manufacturing default.
4. Should you make a claim, please contact your TeleDart® specialist dealer or us directly. Addresses can be
found in the operation manual or on our internet site: www.teledart.com. The guarantee ends immediately
if repairs or any manipulation of the product are made by none authorized persons or if you use spares,
change parts or add accessories which are not of TeleDart’s original production and which then cause a
damage.
5. Products for which you make a claim have to be send or given over to the seller or to a TeleDart ®
specialist dealer. You must insure the dispatch or bear the costs for any loss or damage incurred and for
the transport costs.
6. If you make a guarantee claim, please add the fully completed guarantee documents as well as a proof of
the original purchase within the guarantee period for your specialist dealer. The guarantee claim must
clearly illustrate the complaint, presuming that it is based of a specific defect demonstrated by facts and
when the defect occurred. Further, the complete serial number of the applicator must be readable.
7. A guarantee claim will not be accepted for damages, which are irrelevant for the value or the use of the
applicator, which are caused by irregular environmental conditions, unprofessional use or use which is not
in accordance with regulations. If the points in the user and maintenance manual are not observed a
guarantee claim will not be accepted.
8. Should the applicator be used in another country than the country it had been developed and produced in,
it may be that some technical changes are necessary to adopt the applicator to the technical resp. security
norms of this country. These changes are not caused by material or manufacturing default and are not
covered by this guarantee. Costs for such changes or damages this may cause are not reimbursed.
9. The guarantee is a product guarantee and can be claimed during the guarantee period by any person who
has purchased the product in a legal way. The legal right of the buyer following the national legally
applicable rights, resp. the rights of the buyer as a part of the purchase contract as well as other rights are
not affected by this guarantee. As far as the national law does not require other, the claims are restricted to
the points named in this guarantee. TeleDart GmbH & Co.KG and all specialist dealers are not liable for
indirect resp. subsequently lost or injuries of persons or animals or for the lost of dart syringes, needles or
drugs.
10. Guarantee claims do not extend the guarantee period nor do they lead to a new guarantee period. The
guarantee period for all built-in spare parts finishes at the moment when the guarantee for the complete
applicator finishes. In case of a replacement TeleDart® can determine a new time of guarantee which can
be restricted under consideration of the time of use of the replaced applicator.
11. We do not assume liability for further or other claims, especially for those caused by damages which are
not created by the applicator– if such a claim is not mandatory law.
These guarantee rules are valid after 2006-12-01.
Please consider as well our additional after-sale service:
Even after expiration of the guarantee TeleDart® or our specialist dealers are always at your disposal.
If you decide for TeleDart®, don’t worry about a good service.
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.