TeleDart RD206, RD206-D User Manual

TeleDart GmbH & Co. KG, Obere Heide 8, 67368 Westheim, Germany
TeleDart Injection Pistol RD206 / RD206-D
INTRODUCTION
Be sure that we stand with all our energy and passion behind our products and that your decision for TeleDart ® was the right one. We look forward to assisting you with words and deeds during a long period of time and to offering you the service you can expect from a quality product. Our conviction and our confidence in our products allow us to guarantee you the function of your applicator for the next 20 years.
Please study the following operator’s manual carefully and follow all our directions and instructions. Then you will be sure to do your remote injections safely and without problems.
Successful working!
The Team of TeleDart ®
Pressure table for the TeleDart® applicator RD206 / RD206-D
Dear customer,
Thank you for having chosen a TeleDart® applicator.
This applicator has been tested in a closed area.
Please note that this is only a guideline, which may differ from your own shooting results as wind and weather conditions as well as the shooting skills of the user can change these results considerably.
CO2 AIR Se.-Nr.: ______________
Distance: 15m
Optical Device syringe barrel (cal.) pressure
Optical Device syringe barrel (cal.) pressure
Optical Device syringe barrel (cal.) pressure
TeleDart GmbH & Co. KG
Standard
Rifle scope
Red dot
Standard
Rifle scope
Red dot
Standard
Rifle scope
Red dot
11 mm bar 11 mm bar 11 mm bar
13 mm bar 13 mm bar 13 mm bar
16 mm bar 16 mm bar 16 mm bar
Seite 1 27.06.2019
TeleDart GmbH & Co. KG, Obere Heide 8, 67368 Westheim, Germany
Technical data:
Weight Approx. 1,2 kg
Overall length with barrel Material
90 cm Aluminium
Barrels / Syringe volumes
Plug-on barrel system with adapter
Calibre 11 (1 ccs to 5 ccs) Calibre 13 (5 ccs to 20 ccs) Calibre 16 (1 ccs to 20 ccs)
Short barrel Available
Optimal range
with standard barrel calibre 11mm
1 m – 30 m (depending on dart size)
Standard sight Backsight / front sight
Pressure build-up CO2 cartridge (16 g/45 g) / Airpump Pressure control RD206 Continuous (0 – 10 bar)
Pressure control RD206-D Continuous (0-6 bar)
Safety striker Yes (pin retainer) Safety valve Yes Pressure relief valve Yes
Kinetic energy > 7.5 joules
Seite 2 27.06.2019
TeleDart GmbH & Co. KG, Obere Heide 8, 67368 Westheim, Germany
1. Delivery
Please check upon receipt of our delivery, if your consignment is:
complete corresponds to the ordered equipment undamaged
Please inform us immediately, latest 48 hours after receipt of goods if you have any damage by sending us or your dealer a letter/fax or e-mail. Our service team will handle your claim immediately.
2. Safety Advices
Always point the applicator in a safe direction. Never point at other people even if your applicator is not loaded.
Always keep your applicator with the barrel down to the ground.
Keep your applicator on safe, until you intend to shoot.
Be aware that the applicator has a danger zone of almost 100 meters / 110 yards. Be sure that no other persons are inside this area and that there are no public alleys, streets or squares.
Collect all used darts and part of darts after use, even if they are empty or damaged.
Avoid that children and other unauthorized individuals enter into possession of darts or part of darts.
Clean darts and part of darts contamined with drugs before disposing them.
Never use drugs or alcohol while handling this product.
Never use our applicators with pure oxygen (e.g. oxygen cartridges)!
Of course, all regulations applicable in your country with regard of the handling of weapons as well as animal protection and welfare are valid. Follow strictly all safety advices of the drug producer.
Noticable damages For noticable damages, which are caused by improper handling of the applicator or
by other extraneous causes the use of the applicator must be stopped immediately. In such case first the barrel and second the dart must be removed and the applicator completely depressurized. This happens by careful removal of the CO2-cartridge or depressed air cylinder first and is followed by the complete depressurizing of the pressure chamber. For further instructions please contact your dealer or us directly.
Please follow all safety advices we give you in this operator’s manual.
Seite 3 27.06.2019
TeleDart GmbH & Co. KG, Obere Heide 8, 67368 Westheim, Germany
3. Handling and use
Before use
Make yourself familiar with all operation elements of your applicator before you attempt to test the applicator and go into practice.
TeleDart ® RD206 can be constructed for right- and lefthanded users, which allows to order your applicator according to your individual requirements.
Before shipment, all TeleDart ® applicators are tested at a distance of 15m (16 yds) using a TeleDart ® Dart Syringe 3cc.
For your training we recommed to fill the dart with water and to use a training needle TN1530. In that case it is not necessary to pressurize the dart syringe. If you have to work with other dart volumes, please proceed in the same way. In order to always guarantee the best ballistics, the syringe dart has to be filled completely. Note down all pressure values and make your individual pressure table.
Assembling
Safety Check if the trigger safety is pushed in. The red ring must not be visible.
Inserting of the CO2-cartridge Unscrew the cartridge holder and insert a CO2-cartridge. Tighten up the cartridge
holder until the cartridge is tapped.
Only replace open cartridges if they are completely empty. Further all safety
advices marked on the packing of the CO2-cartridges are valid. TeleDart ® does not assume any liability for damages and injuries caused by improper handling of CO2-cartridges.
Connecting the foot-airpump The lateral tube connection is located on the lower part of the pistol grip. Latch the
hose of the foot-airpump with the hose connector. To unlatch the foot-airpump the locking sleeve of the hose connector has to be pushed back until the hose unlatches.
Pressurizing The applicator is pressurized if you push the pressure regulation knob down. Observe
the gauge and release the knob when you have reached the desired pressure. In case you have built up too much pressure, you can correct that easily. Just push the
pressure release valve until you have reached the desired pressure. When pressurizing with the air pump, the air pump must be reconnected to build up
pressure after each shot.
The TeleDart ® RD206 has a safety valve, which opens automatically if you exceed the allowed maximum pressure of 10 bar (Version RD206-D at 6 bar).
The safety valve is engineered to protect your applicator from damages caused by dangerous overpressure > 10 bar (> 6 bar RD206-D). The exceeding of the particular maximum pressure into the red marked area of the manometer can cause damages to your applicator. Damages to material, which are proven to be caused by deliberate exceeding of the maximum pressure cease our guarantee!
We want to point out that a verifiable manipulation of the safety valve immediately
ceases our guarantee and in this case we do not assume any liabilityfor damages to persons or material.
Seite 4 27.06.2019
TeleDart GmbH & Co. KG, Obere Heide 8, 67368 Westheim, Germany
Loading of the dart syringe Using the positioning pin first insert the syringe into the backside of the barrel and
make sure, that the flight stabilizer is completely inserted into the barrel. Put the barrel onto the barrel retainer as far as it will go. The notch has to show exactly to the top!
The shooting The applicator is now ready for shooting. The trigger safety can now be de-activated by
pulling the trigger safety bolt in shooting direction as far as it will go - until you can see the red ring. Now fix your aim. Push the trigger in one fast movement to allow precise shooting.
Immediately after shooting please activate the trigger safety by pushing the trigger safety bolt inside as far as it will go. The red ring must dissappear again.
4. Care
The applicator can be cleaned with a moist cloth. Never use chemical cleansers or oil!
Regularely check, if there is dirt inside the barrel. If necessary brush it dry with the cleaning brush (comes with the barrel). Don’t use chemical cleansers or oil.
Further care is not necessary.
5. Maintenance
Special maintenance is not necessary. If your barrel becomes difficult to fix, grease the o-rings of the barrel retainer.
6. Storage
For storage and transportation all legal requirements must be complied with. Always store the applicator with activated trigger safety and at a dry place. CO2-cartridges can remain in the applicator.
If you have not used your applicator for a longer time, please check the function first.
7. Accessory Equipment
- Mounting rail MSR for red-dot sights
- Red-Dot Sight OP2
- Laser Rangefinder RF (not mountable)
- Adaptor AR45 for large CO2-cartridges 45gr CO245
- Foot-airpump FP (for RD206-CO2)
- CO2-Device DOC (for RD206-AIR)
- Additional barrel BAP11 (11mm), BAP13 (13mm) or BAP16 (16mm)
- Short barrel calibre 11mm (1-5cc); Length: 40cm
TeleDart GmbH & Co. KG
Westheim, November 1st, 2018
Seite 5 27.06.2019
TeleDart GmbH & Co. KG, Obere Heide 8, 67368 Westheim, Germany
Dear Customer
TeleDart ® Guarantee and Warranty Conditions (E)
We would like to thank you for your confidence in buying this German quality product of TeleDart ®. Our applicators pass several quality controls before being delivered to the final user to be sure they will fulfil the demands we guarantee you here as follows.
In addition to your legal rights, TeleDart ® guarantees:
1. For this product we give you a function guarantee of 20 years. The guarantee begins on the day of purchase of the final user.
2. Should the product show defects within the guarantee period, it will either be repaired or replaced as decided by Teledart ®. A replaced product is TeleDart’s property as soon as it is returned.
3. Under the following rules we repair or replace damages or defaults of the product, which are proven to be caused by a material or manufacturing default.
4. Should you make a claim, please contact your TeleDart ® specialist dealer or us directly. Addresses can be found in the operation manual or on our internet site:
www.teledart.com. The guarantee ends immediately
if repairs or any manipulation of the product are made by none authorized persons or if you use spares, change parts or add accessories which are not of TeleDart’s original production and which then cause a damage.
5. Products for which you make a claim have to be send or given over to the seller or to a TeleDart ® specialist dealer. You must insure the dispatch or bear the costs for any loss or damage incurred and for the transport costs. Cost of transport must be paid by the owner.
6. If you make a guarantee claim, please add the fully completed guarantee documents as well as a proof of the original purchase within the guarantee period for your specialist dealer. The guarantee claim must clearly illustrate the complaint, presuming that it is based of a specific defect demonstrated by facts and when the defect occured. Further, the complete serial number of the applicator must be readable.
7. A guarantee claim will not be accepted for damages, which are irrelevant for the value or the use of the applicator, which are caused by irregular environmental conditions, unprofessional use or use which is not in accordance with regulations. If the points in the user and maintenance manual are not observed a guarantee claim will not be accepted.
8. Should the applicator be used in another country than the country it had been developed and produced in, it may be that some technical changes are necessary to adopt the applicator to the technical resp. security norms of this country. These changes are not caused by material or manufacturing default and are not covered by this guarantee. Costs for such changes or damages this may cause are not reimbursed.
9. The guarantee is a product guarantee and can be claimed during the guarantee period by any person who has purchased the product in a legal way. The legal right of the buyer following the national legally applicable rights, resp. the rights of the buyer as a part of the purchase contract as well as other rights are not affected by this guarantee. As far as the national law does not require other, the claims are restricted to the points named in this guarantee. TeleDart GmbH & Co.KG and all specialist dealers are not liable for indirect resp. subsequently lost or injuries of persons or animals or for the lost of dart syringes, needles or drugs.
10. Guarantee claims do not extend the guarantee period nor do they lead to a new guarantee period. The guarantee period for all built-in spare parts finishes at the moment when the guarantee for the complete applicator finishes. In case of a replacement TeleDart ® can determine a new time of guarantee which can be restricted under consideration of the time of use of the replaced applicator.
11. We do not assume liability for further or other claims, especially for those caused by damages which are not created by the applicator– if such a claim is not mandatory law.
These guarantee rules are valid after 2006-12-01.
Please consider as well our additional after-sale service:
Even after expiration of the guarantee TeleDart ® or our specialist dealers are always at your disposal. If you decide for TeleDart ®, don’t worry about a good service.
Seite 6 27.06.2019
Loading...