Teleco TVLink RS868 Instructions Manual

TELECO AUTOMATION SRL - Via dell’Artigianato, 16 - 31014 Colle Umberto (TV) ITALY TELEPHONE: ++39.0438.388511 FAX: ++39.0438.388536 www.telecoautomation.com
This document is the property of Teleco Automation Srl who reserves all reproduction and copying rights
1- GENERAL DESCRIPTION
Electronic for the remote control of tubular motors for roller blinds, rolling shutters, doors with limit switch inside or outside the motor, radio receiver section with transmitter channel memorization by means of internal push button or via radio. Possibility to connect wired with auto-test control before every closing movement. Possibility to connect a 240 V
courtesy lamp with variable time from 1 min. to 12 hours (default 1min.) Plastic housing for external use equipped with clamps. Possibility of centralized controls for simultaneous control of several appliances. Possibility to connect external mechanical controls with dynamic push button function and blockage push button.
2- CONNECTIONS
Zone 240V
Ground
Motor Earth
Mains Earth
Power supply 240V
L
Mains Live
N
Mains Neutral
Open
Motor
Com
Close
Motor
Description of the connections:
1 Input ground general power supply 2 Input ground motor 3 Input general power supply 240 V 4 Input general power supply 240 V neutral 5 Opening output relay motor contact 6 Output 240 V neutral by means of fuse (common motor) 7 Closing output relay motor contact
phase
Safety zone, isolated low voltage
TD
+ 12V
Com
neg tx FTC
FTC
Com
TBRéflex photocell
TD
Com
TB
15 FTC input (NC normally closed)
19 Push buttons common for TD 20 Dynamic push-button input (NO normally open)
21 Stop push-button TB (NC normally closed) 22 Push buttons common for TB
10-11 Output LC 240 V 300 W max. for courtesy lamp (only for the version with courtesy light) 12 Positive output 12/15Vdc 80mA for photocells 13 Safety common contact 14 Negative output for photocells (autotest)
TVLink RS868
TVPRP868F08E
24 Antenna ground 25 Antenna pole (wire 8.5cm)
T574.01
1
DateCode Number: Series Model number Draft
25/11/13
Warning: The installed safety device must ensure the safety of the door according to EN13241-1 (EN12453, EN12445)
If TB stop NC contact is not used it must be jumpered.
If the FTC input NC is not used it must be jumpered to 14 terminal
Connections with reex
com
nc
-
12/15 Vdc
+
14 15
REFLEX
if the FTC input are not used put a bridge between 14 and 15 terminals
Connections with photocells
8,2Kohm resistance
14 15
if the FTC input are not used put a bridge between 14 and 15 terminals
TB
3- Technical specications
Reception frequency 868.3 MHz Sensibility (nely tuned signal) 1 uV Power supply 240 V Operating temperature range -20° – +50°C Maximum power at the motor: Voltage 250 V Maximum power 400 W Maximum commutable power at output courtesy lamp 240 V 300 W
Antenna
The correct installation and connection of the antenna is fundamental in order to obtain a good action ray for the installation. Connect the provided 8.5 cm piece of wire to the antenna pole connection on the device. As an alternative (and for better results) use a tuned antenna connected to the receiver via coaxial cable RG58 (impedance 50ohm) with a maximum length of 15 metres (mod. ANT868)
2
After the reset, the control unit carries out only opening commands until the door is fully opened. After the complete opening, the functioning of the commands is standard.
4- Dip-switch function
Dip1:
ON
OFF The closing movement is in dead man mode, during the opening it is automatic
1 2
ON
(even if the automatic reclosing is excluded)
1 2
Dip2:
ON The opening and closing movement is automatic.
ON
ON Activation of automatic reclosing **
1 2
ON
OFF Deactivation of automatic reclosing
1 2
**The automatic reclosing is activated only if the door is fully open to the limit switch. After passing the photocell the door closes (after 3 sec.).
3
5.0- To memorize the transmitters from the receiver
Transmitters
The transmitters are encoded in the factory and each transmitter has its own unique code. Caution! If you keep a channel button pressed down for more than 30 seconds the transmitter will automatically turn off. The receiver is compatible with all transmitters of the TVLink range: TVTXV, TVTXP, TVTXE, TVTXC, TVTXI, TVTXK, TVTXQ, TVTXL, TVTXS. The transmitter code can be inserted (memorized) or deleted directly in the receiver or via radio from the transmitter. This last possibility allows to insert new transmitters into an existing installation, with­out acting directly on the receiver. This may be carried out easily by the end user without the help of the installer, and guaranteeing the total secrecy of the code.
- The codes transmission type is “Rolling- code”. The code is changed for every transmission through the use of an algorithm that only the receiver is able to recognize and therefore to decide if the trans­mitted code corresponds to the original code.
- In the receiver the user code is memorized under Eeprom, which maintains the code information even when faced with blackouts (max. 42 code-memorizations). It is adjustable to delete the whole memory before each installation.
Errors during the memorizing
If the code is not memorized it could be due to the following conditions:
-The code already exists in memory
-The memory is full (max. 42 codes). In this case the Buzzer will make 3 beeps both during the memorization phase both after the reset of the receiver.
Transmitter le behaviour according to
Battery OK LOW Battery
CHANGE the Battery
battery status:
5.1- Possibility to memorize the transmitter in three ways:
1 - Mode 1: Single channels with dynamic function, open, stop, close 2 - Mode 2: Control from two channels ch1 with ch2, ch3 with ch4 and ch5 with ch6 and ch7. Ch1, ch3, ch5 for opening controls, ch2, ch4 and ch7 for closing controls, ch6 stop. 3- Mode 3: the memorised channel operates on the courtesy light in on/off mode.
5.1.1- Mode 1: single push-button
The memorization of the channels is carried out in single mode for each channel; the memorised channel will activate the controls in dynamic mode open, stop, close.
Press and hold the push button P1, the buzzer B1 will make 1 beep and sound continuously.
Transmit the channel which is to be memorized, the buzzer B1 will sound intermittently.
open, stop, close
Beep ... Beeeeeep
Beep Beep Beep Beep