TelcoBridges TM-1000 Installation Manual

TM-1000 Installation Guide for
Toolpack Monitoring
Document number
9000-00015-1A
TM-1000 Installation Guide for Toolpack
CONFIDENTIAL
9000-00015-1A
Page 2 of 32
Copyright © 2003-2016 by TelcoBridges
The information in this document is subject to change without notice. No part of this document may be reproduced or transmitted in any form or by any means, electronic or mechanical, for any purpose, without the express written permission of TelcoBridges. TelcoBridges may have patents or pending patent applications, trademarks, copyrights, or other intellectual property rights covering subject matter in this document. The furnishing of this document does not give you license to these patents, trademarks, copyrights, or other intellectual property except as expressly provided in any written license agreement from TelcoBridges.
The information provided in this document is intended as a guide only. For the latest detailed engineering specifications, please contact your TelcoBridges Application Engineer. TelcoBridges is committed to continually improving product designs, as a result, product specifications may be subject to change without notification.
© 2003-2016 TelcoBridges. All rights reserved.
Document Title: TM-1000 Installation Guide
Document Number: 9000-00015-1A
TelcoBridges, On a Blade, System-Blade, TB-1+1 Solution, TB-16-E1/T1/J1, TB640-DS3, TB640-E1/T1/J1, TB640­OC3/STM-1, TB-8-E1/T1/J1, TB-IVR Mezzanine, TB-Multi-Blade, TB-Multi-Blade Mezzanine, TB-N+1-15 Solution, TB-N+1-3 Solution, TB-StreamServer, TB-Video, TB-VoIP Mezzanine, TM-1000 Network Probe are trademarks of TelcoBridges Inc. All rights reserved 2007. All other trademarks are property of their owners. Information subject to change without notice.
Document Revision
Revision Number
Date
By
Comments
HEAD OFFICE
115-A1 De Vaudreuil, Boucherville, Quebec,
Canada, J4B 1K7 T +1 450 655 8993 F +1 450 655 9511
info@telcobridges.com
support@telcobridges.com
9000-00015-1A
CONFIDENTIAL
TM-1000 Installation Guide for Toolpack
Copyright © 2003-2016 by TelcoBridges
Page 3 of 32
Preface
Introduction
Purpose and Scope of this document
This document describes how to install TM-1000.
How to use this document
This document should be used as a reference material.
Obtaining Support
Email Technical Support
Remote technical support by email is available to all TelcoBridges customers 7 days a week, 24 hours a day, and enquiries shall be responded to no later than 36 hours after reception.
Please send technical support requests by email to: support@telcobridges.com
To accelerate the service, please send your request for technical support with the following information:
1. Description of the problem,
2. TB udplisten log (if available)
3. tb640debug .dmp files
Onsite Field Services
TelcoBridges offers professional onsite field services. These services help reduce your development time,
accelerate system deployments provide additional assurances in realizing the full benefits of your TelcoBridges products. Onsite field services are delivered by TelcoBridges product experts who bring extensive knowledge to meet your business and technical requirements.
TelcoBridges’ Customer Service Department provides customized proposals based on your specific requirements. The Customer Service Department can be contacted Monday to Friday (except holidays) from 09:00 to 17:00 (GMT -5 hours) at:
Telephone: +1 514 855 8993
Fax: +1 514 655 9511
Email: support@telcobridges.com
Training and Educational Services
Training greatly reduces your time to market and enhances your in-depth knowledge of TelcoBridges products.
TelcoBridges provides customer technical training in Boucherville, Quebec, Canada, or upon request on customer premises. We provide instructor-led courses with a mix of theoretical and hands-on experience that prepare your engineering team to successfully develop using the TelcoBridges platform.
TelcoBridges’ Customer Service Department provides customized proposals based on your specific training requirements. The Customer Service Department can be contacted Monday to Friday (except holidays) from 09:00 to 17:00 (GMT -5 hours) at:
Telephone: +1 514 855 8993
Fax: +1 514 655 9511
Email: support@telcobridges.com
On-Line Web Documentation
Online web support documentation services https://docs.telcobridges.com. The information available online is accessible around-the-clock:
TM-1000 Installation Guide for Toolpack
CONFIDENTIAL
9000-00015-1A
Page 4 of 32
Copyright © 2003-2016 by TelcoBridges
Product documentation
Web Portal documentation
Software version
Comments about the TelcoBridges Documentation
TelcoBridges Welcomes Your Comments
TelcoBridges is interested in improving its documentation and welcomes your comments and suggestions.
You can email your comments to TelcoBridges at: support@telcobridges.com
Please include the part number or name of your document in the subject line of your email.
9000-00015-1A
CONFIDENTIAL
TM-1000 Installation Guide for Toolpack
Copyright © 2003-2016 by TelcoBridges
Page 5 of 32
Table of contents
Preface ...................................................................................................................................................................... 3!
1.! System Requirements ................................................................................................................................................... 7!
1.1.! Equipment Required .............................................................................................................................................. 7!
1.2.! Application Server Requirements ......................................................................................................................... 8!
1.2.1.! Recommended Windows System Requirements: .......................................................................................... 8!
1.2.2.! Recommended Linux System Requirements ................................................................................................. 8!
2.! Hardware Equipment ................................................................................................................................................... 9!
2.1.! TM-1000 Front View and Physical Dimensions ................................................................................................... 9!
2.2.! TM-1000 Environmental Specifications ............................................................................................................. 10!
2.3.! TM-1000 right side view ..................................................................................................................................... 11!
2.4.! TM-1000 left side view ....................................................................................................................................... 11!
2.5.! TM-1000 rack-mounting brackets and screws .................................................................................................... 11!
2.5.1.! TM-1000 with left side bracket installed ..................................................................................................... 12!
2.5.2.! TM-1000 with right side bracket installed ................................................................................................... 12!
2.6.! TM-1000 LED Description ................................................................................................................................. 13!
2.7.! TM-1000 Rear View ........................................................................................................................................... 13!
2.8.! TM-1000 DC Power Supply Option ................................................................................................................... 14!
2.8.1.! TM-1000 AC Power Supply Option Description ......................................................................................... 14!
2.9.! TM-1000 Reset, Auxiliary 1 and 2 Description .................................................................................................. 15!
2.10.! TM-1000 Serial Port RS-232 ............................................................................................................................ 16!
2.11.! TM-1000 Ethernet 1 and 2 ................................................................................................................................ 17!
2.12.! Network Protocol and Standards Compatibility ............................................................................................... 17!
2.13.! TM-1000 E1/T1/J1 Input Cable Connectors ..................................................................................................... 18!
2.14.! Patch panel SCSI-3 connector ........................................................................................................................... 18!
3.! Patch panel with 32 x RJ-45 ....................................................................................................................................... 20!
3.1.! Patch panel front view ......................................................................................................................................... 20!
3.2.! Patch panel rear view .......................................................................................................................................... 20!
3.3.! Patch panel trunk impedance selector switch ...................................................................................................... 21!
3.4.! Patch Panel Selector Switch Fit with TM-1000 Cable-1 .................................................................................... 22!
3.5.! Patch panel selector switch fit with TM-1000 cable-2 ........................................................................................ 22!
3.6.! Patch panel selector switch fit with TM-1000 cable-3 ........................................................................................ 23!
3.7.! Patch panel selector switch fit with TM-1000 cable-4 ........................................................................................ 23!
3.8.! RJ45 (RJ48C) Connector .................................................................................................................................... 24!
4.! TM-1000 Hardware Installation ................................................................................................................................. 25!
5.! Configure the TM-1000 ............................................................................................................................................. 26!
5.1.! Configure the TM-1000 with the serial port ....................................................................................................... 26!
5.1.1.! Create a connection name ............................................................................................................................ 26!
5.1.2.! Set the com port ........................................................................................................................................... 27!
5.1.3.! Set Bits rate Flow control ............................................................................................................................. 27!
5.1.4.! The TM-1000 should be connected .............................................................................................................. 28!
5.2.! Configure IP addresses ........................................................................................................................................ 29!
5.2.1.! set_net command .......................................................................................................................................... 29!
5.2.2.! print_net command ....................................................................................................................................... 30!
6.! Software Installation .................................................................................................................................................. 31!
6.1.! Installing Toolpack .............................................................................................................................................. 31!
6.2.! Toolpack Configuration Web Portal ................................................................................................................... 31!
7.! Upgrading the TM-1000 Firmware and license ......................................................................................................... 31!
7.1.! Installing a license ............................................................................................................................................... 31!
8.! Toolpack API ............................................................................................................................................................. 32!
8.1.! Getting Started .................................................................................................................................................... 32!
8.2.! Compiling Libraries ............................................................................................................................................ 32!
8.3.! Sample Application ............................................................................................................................................. 32!
8.4.! Stop and disable Gateway application ................................................................................................................ 32!
TM-1000 Installation Guide for Toolpack
CONFIDENTIAL
9000-00015-1A
Page 6 of 32
Copyright © 2003-2016 by TelcoBridges
Figures
Figure 1 TM-1000 Network Diagram ................................................................................................................................. 7!
Figure 2 TM-1000 rear view DC Power supply option and ground post ........................................................................... 9!
Figure 3 TM-1000 Front View ........................................................................................................................................... 9!
Figure 4 TM-1000 right side view .................................................................................................................................... 11!
Figure 5 TM-1000 left side view with three cooling fans ................................................................................................. 11!
Figure 6 TM-1000 left and right side bracket kit ......................................................................................................... 11!
Figure 7 TM-1000 left side right angle .......................................................................................................................... 12!
Figure 8 TM-1000 right side right angle ....................................................................................................................... 12!
Figure 9 TM-1000 Front View LED description .............................................................................................................. 13!
Figure 10 TM-1000 rear view ........................................................................................................................................... 13!
Figure 11 TM-1000 rear view DC Power supply option and ground post ....................................................................... 14!
Figure 12 TM-1000 rear view AC Power supply option, On/Off switch and ground post .............................................. 14!
Figure 13 TM-1000 rear view Reset and auxiliary feature ............................................................................................... 15!
Figure 14 TM-1000 rear view RS-232 Link ..................................................................................................................... 16!
Figure 15 TM-1000 RS-232 Pin Out .............................................................................................................................. 16!
Figure 16 TM-1000 rear view Ethernet 10/100/1G ports ................................................................................................. 17!
Figure 17 TM-1000 rear view SCSI-3 input connection ................................................................................................. 18!
Figure 18 Patch panel SCSI-3 connector ...................................................................................................................... 18!
Figure 19 Patch panel front view ................................................................................................................................... 20!
Figure 20 Patch panel rear view .................................................................................................................................... 20!
Figure 21 Patch panel impedance selector switch ........................................................................................................ 21!
Figure 22 Patch panel impedance selector switch ........................................................................................................ 21!
Figure 23 Hyper Terminal configuration step #1 .............................................................................................................. 26!
Figure 24 Hyper Terminal configuration step #2 ........................................................................................................ 27!
Figure 25 Hyper Terminal configuration step #3 ........................................................................................................ 27!
Figure 26 Serial connection should be enabled ............................................................................................................ 28!
Figure 27 set_net command ........................................................................................................................................... 29!
Figure 28 print_net command ....................................................................................................................................... 30!
Tables
Table 1 TM-1000 dimension ............................................................................................................................................ 10!
Table 2 TM-1000 environmental specifications ............................................................................................................... 10!
Table 3 TM-1000 Front LED status .............................................................................................................................. 13!
Table 4 TM-1000 DC Power supply .............................................................................................................................. 14!
Table 5 TM-1000 RS-232 DB-9 pin out ......................................................................................................................... 16!
Table 6 TM-1000 Ethernet LED description ................................................................................................................ 17!
Table 7 TM-1000 Ethernet RJ-45 pin out ..................................................................................................................... 17!
Table 8 TM-1000 SCSI-3 trunk cable input ................................................................................................................. 19!
Table 9. Patch panel selector switch fit with TM-1000 Cable-1, trunks 1-16 and 65-80 ........................................... 22!
Table 10. Patch panel selector switch fit with TM-1000 Cable-2, trunks 17-32 and 81-96 ....................................... 22!
Table 11. Patch panel selector switch fit with TM-1000 Cable-3, trunks 33-48 and 97-112 ..................................... 23!
Table 12. Patch panel selector switch fit with TM-1000 Cable-4, trunks 49-64 and 113-128 ................................... 23!
Table 13 RJ-45 (RJ-48C) E1/T1/J1 ............................................................................................................................... 24!
9000-00015-1A
CONFIDENTIAL
TM-1000 Installation Guide for Toolpack
Copyright © 2003-2016 by TelcoBridges
Page 7 of 32
1. System Requirements
Figure 1 TM-1000 Network Diagram
1.1. Equipment Required
TM-1000
Control system (Application Server)
One null modem DB-9 serial cable to connect the TM-1000 serial port to the Windows system serial port
(lines 2 and 3 need to be crossed). This is required only for IP address configuration.
Two 1 Gbps Ethernet adapters
Two Gigabit switches (8 ports minimum) for control redundancy
Four Ethernet cables
One power source, either 110-220V AC, 4 AMP for TM-1000 option AC or 48V DC, 9 AMP for TM-
1000 option DC
Up to 64 E1/T1/J1 source for monitoring full-duplex
Up to two monitoring patch panels with RJ-45 input connectors
Up to four SCI-3 cables for connection between the TM-1000 and the patch panels
TM-1000 Installation Guide for Toolpack
CONFIDENTIAL
9000-00015-1A
Page 8 of 32
Copyright © 2003-2016 by TelcoBridges
1.2. Application Server Requirements
1.2.1. Recommended Windows System Requirements:
Pentium 4: 3Ghz or higher processor with 1GB RAM
Two 100Mbps/1Gbps Ethernet adapters. We recommend 1Gbps if this host is running the
TB-StreamServer
Windows 2000 Professional/Server with Service Pack 3 or later, or Windows XP with Service Pack 2 or
later. The TM-1000 software package has not been tested on any other version of Windows.
1.2.2. Recommended Linux System Requirements
Intel or AMD-based system, 3Ghz or more with 1GB of memory
Two 100Mbps/1Gbps Ethernet adapters. We recommend 1Gbps if this host is running the
TB-StreamServer
9000-00015-1A
CONFIDENTIAL
TM-1000 Installation Guide for Toolpack
Copyright © 2003-2016 by TelcoBridges
Page 9 of 32
2. Hardware Equipment
Preventing Electrostatic Discharge Damage
Electrostatic discharge (ESD) can damage equipment and impair electrical circuitry. It can occur if electronic printed circuit cards are improperly handled and can cause complete or intermittent failures.
Always follow ESD prevention procedures when removing and replacing modules:
Ensure that the TM-1000 is electrically connected to earth ground.
Wear an ESD-preventive wrist strap, ensuring that it makes good skin contact. Connect the clip to
an unpainted surface of the TM-1000 to channel unwanted ESD voltages safely to ground. To guard against ESD damage and shocks, the wrist strap and cord must operate effectively.
If no wrist strap is available, ground yourself by touching a metal part of the chassis.
Figure 2 TM-1000 rear view DC Power supply option and ground post
2.1. TM-1000 Front View and Physical Dimensions
Figure 3 TM-1000 Front View
W H L
Ground
Chassis Ground
TM-1000 Installation Guide for Toolpack
CONFIDENTIAL
9000-00015-1A
Page 10 of 32
Copyright © 2003-2016 by TelcoBridges
Dimension
Inches
Centimeters
Length
17 ¼
43.8
Width
11
27.9
Height
1 ¾
3.8
Table 1 TM-1000 dimension
Unit Weight: 9 LB or 4.1 Kg
2.2. TM-1000 Environmental Specifications
Operating temperature
0° to 40°C (32° to 104°F)
Storage temperature
-20° to 70°C (-4° to 158°F)
Operating relative humidity
10% to 85% non-condensing
Storage relative humidity
10% to 85% non-condensing
Table 2 TM-1000 environmental specifications
When selecting an installation site, observe these guidelines:
Cabling is away from sources of electrical noise, such as radios, power lines, and fluorescent lighting fixtures
Clearance to the TM-1000 is such that:
Airflow around the TM-1000 and through the vents is unrestricted
Front-panel LEDs can be easily read
Access to ports is sufficient for unrestricted cabling
AC power cord can reach from the AC power outlet to the connector on the TM-1000. The power outlet
must be accessible at all times because it serves as the main method to disconnect power from the TM­1000
9000-00015-1A
CONFIDENTIAL
TM-1000 Installation Guide for Toolpack
Copyright © 2003-2016 by TelcoBridges
Page 11 of 32
2.3. TM-1000 right side view
Figure 4 TM-1000 right side view
2.4. TM-1000 left side view
Figure 5 TM-1000 left side view with three cooling fans
2.5. TM-1000 rack-mounting brackets and screws
Figure 6 TM-1000 left and right side bracket kit
Cooling fans
TM-1000 Installation Guide for Toolpack
CONFIDENTIAL
9000-00015-1A
Page 12 of 32
Copyright © 2003-2016 by TelcoBridges
2.5.1. TM-1000 with left side bracket installed
Figure 7 TM-1000 left side right angle
2.5.2. TM-1000 with right side bracket installed
Figure 8 TM-1000 right side right angle
9000-00015-1A
CONFIDENTIAL
TM-1000 Installation Guide for Toolpack
Copyright © 2003-2016 by TelcoBridges
Page 13 of 32
2.6. TM-1000 LED Description
Figure 9 TM-1000 Front View LED description
Item
Color
Description
Item
Color
Description
PWR
None
No power
LNK
None
Not finished restarting the TM­1000 Red
Power fault
Red
Ethernet port disconnected
Green
Power good
Green
Ethernet port connected
ACT
None
Trunk not allocated
FLT
None
Internal debug status report
Red
Tapping resource not available
Red
Internal debug status report
Solid Green
Trunk allocated
Green
Internal debug status report
Blink Green
Trunk activity
Table 3 TM-1000 Front LED status
2.7. TM-1000 Rear View
Figure 10 TM-1000 rear view
TM-1000 Installation Guide for Toolpack
CONFIDENTIAL
9000-00015-1A
Page 14 of 32
Copyright © 2003-2016 by TelcoBridges
2.8. TM-1000 DC Power Supply Option
Figure 11 TM-1000 rear view DC Power supply option and ground post
Table 4 TM-1000 DC Power supply
You need a Philips screwdriver to tighten the cable tab connections
2.8.1. TM-1000 AC Power Supply Option Description
Figure 12 TM-1000 rear view AC Power supply option, On/Off switch and ground post
Power input from 100 to 240V AC, 47 to 63 Hz with 4 Amp maximum load. This is an auto detect AC power input.
Contact ID
Description
+V
DC Power return
-V
-40 to -65V DC input with 9A max load
GND
Earth ground
+V
-V
GND
Chassis GND
Cooling fan
Cooling fan
PC standard AC power input
Chassis GND
Power ON/Off switch
9000-00015-1A
CONFIDENTIAL
TM-1000 Installation Guide for Toolpack
Copyright © 2003-2016 by TelcoBridges
Page 15 of 32
2.9. TM-1000 Reset, Auxiliary 1 and 2 Description
Figure 13 TM-1000 rear view Reset and auxiliary feature
You will need to insert a pin in the hole to reach the reset button
o If you quick press and release the reset button the TM-1000 will restart.
o If you hold on the reset button for at least five seconds, the TM-1000 will shut down.
o If you hold on the reset button for at least five seconds after a shut down, the TM-1000 will restart.
Aux-1 and Aux-2 RJ-45 connectors are used for optional features. These features are not implemented yet. Do
not use Aux-1 and Aux-2 connectors.
TM-1000 Installation Guide for Toolpack
CONFIDENTIAL
9000-00015-1A
Page 16 of 32
Copyright © 2003-2016 by TelcoBridges
2.10. TM-1000 Serial Port RS-232
Figure 14 TM-1000 rear view RS-232 Link
Figure 15 TM-1000 RS-232 Pin Out
Pin number
Description
1
Not connected
2
Receive signal (Rx)
3
Transmit signal (Tx)
4
Not connected
5
Ground
6
Not connected
7
Not connected
8
Not connected
9
Not connected
Table 5 TM-1000 RS-232 DB-9 pin out
9000-00015-1A
CONFIDENTIAL
TM-1000 Installation Guide for Toolpack
Copyright © 2003-2016 by TelcoBridges
Page 17 of 32
2.11. TM-1000 Ethernet 1 and 2
Figure 16 TM-1000 rear view Ethernet 10/100/1G ports
Item
Led color
Description
SPD
Off
Ethernet port connected 100M
Yellow
Ethernet port connected 1G
LNK
Off
Ethernet port disconnected
Solid Green
Ethernet port connected
Blink Green
Ethernet activity on the connected port
Table 6 TM-1000 Ethernet LED description
Connector front view
8 1
Pin number
Description
1
Bi-directional pair A+
2
Bi-directional pair A-
3
Bi-directional pair B+
4
Bi-directional pair C+
5
Bi-directional pair C-
6
Bi-directional pair B-
7
Bi-directional pair D+
8
Bi-directional pair D-
Table 7 TM-1000 Ethernet RJ-45 pin out
Each Ethernet port has a speed auto detect option of 1 Gbps.
2.12. Network Protocol and Standards Compatibility
IEEE 802.3z/ab 1000Base-T
TM-1000 Installation Guide for Toolpack
CONFIDENTIAL
9000-00015-1A
Page 18 of 32
Copyright © 2003-2016 by TelcoBridges
2.13. TM-1000 E1/T1/J1 Input Cable Connectors
Figure 17 TM-1000 rear view SCSI-3 input connection
2.14. Patch panel SCSI-3 connector
Figure 18 Patch panel SCSI-3 connector
The lower SCSI-3 connector is always connected with patch panel number 1 to 16.
The lower SCSI-3 connector must always be connected with Cable-1 or Cable-3 of the TM1000.
The upper SCSI-3 connector is always connected with patch panel number 17 to 32.
The upper SCSI-3 connector must always be connected with Cable-2 or Cable-4 of the TM1000.
Plug only with Cable-1 or Cable-3 of the TM-1000
Plug only with Cable-2 or Cable-4 of the TM-1000
9000-00015-1A
CONFIDENTIAL
TM-1000 Installation Guide for Toolpack
Copyright © 2003-2016 by TelcoBridges
Page 19 of 32
TM-1000 cable trunk input:
RJ-45 Pin 1-2 input
RJ45 Pin 4-5 input
Cable-1
Trunk 1-16
Trunk 65-80
Cable-2
Trunk 17-32
Trunk 81-96
Cable-3
Trunk 33-48
Trunk 97-112
Cable-4
Trunk 49-64
Trunk 113-128
Table 8 TM-1000 SCSI-3 trunk cable input
TM-1000 Installation Guide for Toolpack
CONFIDENTIAL
9000-00015-1A
Page 20 of 32
Copyright © 2003-2016 by TelcoBridges
3. Patch panel with 32 x RJ-45
This patch panel supports 64 trunk inputs (32 full-duplex trunks).
3.1. Patch panel front view
Figure 19 Patch panel front view
3.2. Patch panel rear view
Figure 20 Patch panel rear view
Pull up the cover to remove
2 x Philips screws
9000-00015-1A
CONFIDENTIAL
TM-1000 Installation Guide for Toolpack
Copyright © 2003-2016 by TelcoBridges
Page 21 of 32
Patch panel trunk impedance all selector switch
Figure 21 Patch panel impedance selector switch
3.3. Patch panel trunk impedance selector switch
Figure 22 Patch panel impedance selector switch
Always set the impedance switch as a pair 1-2 and 3-4.
The default settings of the patch panels impedance is Off position (470 Ω).
If you set the switch in the Off position, the input trunk impedance will be high (470 Ω).
If you set the switch in the On position, the input trunk impedance will be low (0 Ω).
Switch 3 and 4
Switch 1 and 2
TM-1000 Installation Guide for Toolpack
CONFIDENTIAL
9000-00015-1A
Page 22 of 32
Copyright © 2003-2016 by TelcoBridges
3.4. Patch Panel Selector Switch Fit with TM-1000 Cable-1
Table 9. Patch panel selector switch fit with TM-1000 Cable-1, trunks 1-16 and 65-80
3.5. Patch panel selector switch fit with TM-1000 cable­2
Table 10. Patch panel selector switch fit with TM-1000 Cable-2, trunks 17-32 and 81-96
Switch Position
1-2
3-4
1-2
3-4
1-2
3-4
1-2
3-4
1-2
3-4
1-2
3-4
1-2
3-4
1-2
3-4
TM-1000 Trunk
Input Rx1|Rx2
1
65 2 66 3 67 4 68 5 69 6 70 7 71 8 72
Trunk Label On
patch Panel
Switch Postion
1-2
3-4
1-2
3-4
1-2
3-4
1-2
3-4
1-2
3-4
1-2
3-4
1-2
3-4
1-2
3-4
TM-1000 Trunk
Input Rx1|Rx2
9
73
10
74
11
75
12
76
13
77
14
78
15
79
16
80
Trunk Label On
patch Panel
Lower
Row 113
14
15
16 9
10
11
12
Switch 7
7
Switch 8
8
Switch 5
5
Switch 6
6
Switch 3
3
Switch 4
4
Upper
Row
Switch 1
1
Switch 2
2
Switch Postion
1-2
3-4
1-2
3-4
1-2
3-4
1-2
3-4
1-2
3-4
1-2
3-4
1-2
3-4
1-2
3-4
TM-1000 Trunk
Input Rx1|Rx2
17
81
18
82
19
83
20
84
21
85
22
86
23
87
24
88
Trunk Label On
patch Panel
Switch Postion
1-2
3-4
1-2
3-4
1-2
3-4
1-2
3-4
1-2
3-4
1-2
3-4
1-2
3-4
1-2
3-4
TM-1000 Trunk
Input Rx1|Rx2
25
89
26
90
27
91
28
92
29
93
30
94
31
95
32
96
Trunk Label On
patch Panel
32 28
29 30
31
Lower
Row
25
26
27
Switch 16
Upper
Row 17
18
19
20
21 22
23
24 Switch 12
Switch 13
Switch 14
Switch 15
Switch 9
Switch 10
Switch 11
9000-00015-1A
CONFIDENTIAL
TM-1000 Installation Guide for Toolpack
Copyright © 2003-2016 by TelcoBridges
Page 23 of 32
3.6. Patch panel selector switch fit with TM-1000 cable­3
Table 11. Patch panel selector switch fit with TM-1000 Cable-3, trunks 33-48 and 97-112
3.7. Patch panel selector switch fit with TM-1000 cable-4
Table 12. Patch panel selector switch fit with TM-1000 Cable-4, trunks 49-64 and 113-128
Switch Postion
1-2 3-4 1-2 3-4 1-2 3-4 1-2 3-4 1-2 3-4 1-2 3-4 1-2 3-4 1-2 3-4 TM-1000 Trunk
Input Rx1|Rx2
33
97
34
98
35
99
36
100
37
101
38
102
39
103
40
104
Trunk Label On
patch Panel
Switch Postion
1-2
3-4
1-2
3-4
1-2
3-4
1-2
3-4
1-2
3-4
1-2
3-4
1-2
3-4
1-2
3-4
TM-1000 Trunk
Input Rx1|Rx2
41
105
42
106
43
107
44
108
45
109
46
110
47
111
48
112
Trunk Label On
patch Panel
8
Lower
Row
9
10
11
12
113
14
15
16 4 5 6
7
Upper
Row
1 2 3
Switch 1
Switch 2
Switch 3
Switch 4
Switch 5
Switch 6
Switch 7
Switch 8
Switch Postion
1-2
3-4
1-2
3-4
1-2
3-4
1-2
3-4
1-2
3-4
1-2
3-4
1-2
3-4
1-2
3-4
TM-1000 Trunk
Input Rx1|Rx2
49
113
50
114
51
115
52
116
53
117
54
118
55
119
56
120
Trunk Label On
patch Panel
Switch Postion
1-2
3-4
1-2
3-4
1-2
3-4
1-2
3-4
1-2
3-4
1-2
3-4
1-2
3-4
1-2
3-4
TM-1000 Trunk
Input Rx1|Rx2
57
121
58
122
59
123
60
124
61
125
62
126
63
127
64
128
Trunk Label On
patch Panel
24
Lower
Row
25
26
27
28
29
30
31
32
20
21
22
23
Upper
Row 17
18
19
Switch 13
Switch 14
Switch 15
Switch 16
Switch 9
Switch 10
Switch 11
Switch 12
TM-1000 Installation Guide for Toolpack
CONFIDENTIAL
9000-00015-1A
Page 24 of 32
Copyright © 2003-2016 by TelcoBridges
3.8. RJ45 (RJ48C) Connector
Connector front view
8 1
Pin number
Description
1
Rx Ring 1
2
Rx Tip 1
3
Not connected
4
Rx Ring 2
5
Rx Tip 2
6
Not connected
7
Not connected
8
Not connected
Table 13 RJ-45 (RJ-48C) E1/T1/J1
9000-00015-1A
CONFIDENTIAL
TM-1000 Installation Guide for Toolpack
Copyright © 2003-2016 by TelcoBridges
Page 25 of 32
4. TM-1000 Hardware Installation
1. By default, the patch panels are set at high (470Ω) impedance. If you need to change the impedance, open
the patch panel cover and set the impedance switch to fit with the trunk line interface that you want to connect with (Reference Section 3 of this document).
2. To rack mount the TM-1000, screw in the brackets (Reference Section 2.5 of this document).
3. Connect the SCSI-3 cables between the patch panel and the TM-1000 (Reference Section 2.14 of this
document).
4. Connect your trunk input with the RJ-45 connectors in the patch panel (Reference Section 3 of this
document).
5. Connect the null serial cable between the TM-1000 and your server (Reference Section 0 of this document
for DB-9 connector pin out).
6. Connect the Ethernet cable from the switch to the TM-1000 ETH-1 and ETH-2 (Reference Section 2.11 of
this document for pin out).
7. Connect the TM-1000 AC or DC power supply, and turn the power on.
8. Configure the IP address and gateway port of the TM-1000 (Reference Section 5.2)
9. Contact TelcoBridges at www.telcobridges.com to get a license and the latest software package for each
TM-1000 (Reference section 6 of this document).
10. Install the package and license (Reference Section 6 of this document).
TM-1000 Installation Guide for Toolpack
CONFIDENTIAL
9000-00015-1A
Page 26 of 32
Copyright © 2003-2016 by TelcoBridges
5. Configure the TM-1000
You will need two free IP addresses on two subnets from your network to configure the TM-1000. (One IP address per subnet.)
5.1. Configure the TM-1000 with the serial port
For serial connection, configure the terminal console application, like Hyper terminal at 9600 BPS, 8 bits, no parity, 1 stop bit, no flow control.
For Ethernet connection, use any console application.
5.1.1. Create a connection name
Figure 23 Hyper Terminal configuration step #1
9000-00015-1A
CONFIDENTIAL
TM-1000 Installation Guide for Toolpack
Copyright © 2003-2016 by TelcoBridges
Page 27 of 32
5.1.2. Set the com port
Figure 24 Hyper Terminal configuration step #2
5.1.3. Set Bits rate Flow control
Figure 25 Hyper Terminal configuration step #3
TM-1000 Installation Guide for Toolpack
CONFIDENTIAL
9000-00015-1A
Page 28 of 32
Copyright © 2003-2016 by TelcoBridges
5.1.4. The TM-1000 should be connected
Figure 26 Serial connection should be enabled
Then press the Enter key to see the following command prompt: TB640>
9000-00015-1A
CONFIDENTIAL
TM-1000 Installation Guide for Toolpack
Copyright © 2003-2016 by TelcoBridges
Page 29 of 32
5.2. Configure IP addresses
5.2.1. set_net command
At the TB640> command prompt type
set_net
to modify the network configuration of the TM-1000. It includes the name of the TM-1000, if the DHCP is enabled or disabled, the IP address, the netmask and the gateway address of both Ethernet ports.
Figure 27 set_net command
adapter name:
Name of the TM-1000. This character string must uniquely identify the TM-1000. The default is the serial number.
DHCP:
Dynamic IP address is used when the TM-1000 is started. Not yet supported
eth0/eth1: ip address:
If not using DHCP, static IP address for port Ethernet 0 and Ethernet 1 of the TM-1000
eth0/eth1: NetMask:
If not using DHCP, network mask for port Ethernet 0 and Ethernet 1 of the TM-1000
eth0/eth1: Gateway:
If not using DHCP, gateway address for port Ethernet 0 and Ethernet 1 of the TM-
1000. If you are planning the use the TM-1000 in the same subnet as the host (that is you don’t require accessing an IP address outside the subnet), the gateway can be set to ‘127.0.0.1’. Do NOT use address ‘0.0.0.0’ as the gateway as it is an invalid address.
Restart the TM-1000 to make the changes effective.
TM-1000 Installation Guide for Toolpack
CONFIDENTIAL
9000-00015-1A
Page 30 of 32
Copyright © 2003-2016 by TelcoBridges
5.2.2. print_net command
To validate the “set_net”command, type “print_net” at the shell prompt of the TM-1000. The following information should be displayed:
Figure 28 print_net command
9000-00015-1A
CONFIDENTIAL
TM-1000 Installation Guide for Toolpack
Copyright © 2003-2016 by TelcoBridges
Page 31 of 32
6. Software Installation
The Toolpack Monitoring framework is available starting from the release 2.9.40. Toolpack framework must be installed on the Application Server (host) that control the TM-1000.
For more information, please refer to https://docs.telcobridges.com/tbwiki/TM1000#Using_TM1000_with_Toolpack
6.1. Installing Toolpack
Refer to the following link for installation.:
https://docs.telcobridges.com/tbwiki/Installing_Toolpack
The installation guide for 2.9 is the same as for 2.8:
https://docs.telcobridges.com/tbwiki/Toolpack_installation_2-8
6.2. Toolpack Configuration Web Portal
The Web Portal is the principal means of interacting with a TM-1000.
https://docs.telcobridges.com/tbwiki/Web_Portal
Configuration:
1. Add the TM-1000 hardware (type TDM and TDM Line Type E1_T1_J1):
- https://docs.telcobridges.com/tbwiki/Toolpack:Adding_an_Adapter_E
2. Configure the 128 tapped E1s (Rx1: index 0 to 63; Rx2: index 64 to 127)
- https://docs.telcobridges.com/tbwiki/Toolpack:Create_E1_Configuration_A
3. Configure the system synchronization clock
- https://docs.telcobridges.com/tbwiki/Toolpack:Defining_a_Clocking_Source_D
7. Upgrading the TM-1000 Firmware and license
The TM-1000 starts from the local file system located on the flash memory. The flash memory comes with a version of the firmware available at production time. The Toolpack framework will update the firmware of the TM-1000 automatically to the installed Toolpack version.
7.1. Installing a license
A valide license must be installed on the TM-1000. See the following link for more information:
https://docs.telcobridges.com/tbwiki/Toolpack:System_Settings_B - Upload_license
TM-1000 Installation Guide for Toolpack
CONFIDENTIAL
9000-00015-1A
Page 32 of 32
Copyright © 2003-2016 by TelcoBridges
8. Toolpack API
This section apply to developers building an application with Toolpack Monitoring API.
8.1. Getting Started
Here is a few documentation pointer to get started with Toolpack API.
https://docs.telcobridges.com/tbwiki/Toolpack_monitoring
https://docs.telcobridges.com/tbwiki/Toolpack_API
https://docs.telcobridges.com/tbwiki/CAF:_Working_With_Cmc_Call_Legs#Capturing_.28monitoring.29_HDLC
https://docs.telcobridges.com/tbwiki/CMC_library
The Toolpack HTML API reference can be found in the tb-doc-dev.zip from the packages download. For example, to download the API for 2.9.40, the path would be (user:telcobridges; pass: tbsupport):
http://download.telcobridges.com/release2.9.40_dev/tb-doc-dev.zip
Unzip the file, and open tb/doc/toolpack/html/index.html
8.2. Compiling Libraries
Download and compile Toolpack source packages:
https://docs.telcobridges.com/tbwiki/Compiling_Toolpack
8.3. Sample Application
The sample application “simple_monitoring” shows to use the Toolpack Monitoring API. The source of the application can be found in /tb/src/toolpack/samples/simple_monitoring/
The compile binaries can be found in:
/tb/src/toolpack/samples/simple_monitoring/release/[os_architecture]/
8.4. Stop and disable Gateway application
Before starting “simple_monitoring”, the Toolpack Framework Gateway application must be stopped and disabled:
1. From the Web Portal, from the left menu, click on “Hosts->Applications”
2. Click on “gateway”
3. Click on remove from the hosts section
4. Click on “Save”
Loading...