Tektronix products are covered by U.S. and foreign patents, issued and
pending. Information in this publication supercedes that in all previously
published material. Specifications and price change privileges reserved.
Tektronix, Inc., P.O. Box 500, Beaverton, OR 97077
TEKTRONIX, TEK, and NETTEK are registered trademarks of Tektronix, Inc.
WARRANTY
Tektronix warrants that the products that it manufactures and sells will be free from defects
in materials and workmanship for a period of one (1) year from the date of purchase from
an authorized Tektronix distributor. If any such product proves defective during this
warranty period, Tektronix, at its option, either will repair the defective product without
charge for parts and labor, or will provide a replacement in exchange for the defective
product. Batteries are excluded from this warranty.
In order to obtain service under this warranty, Customer must notify Tektronix of the
defect before the expiration of the warranty period and make suitable arrangements for the
performance of service. Customer shall be responsible for packaging and shipping the
defective product to the service center designated by Tektronix, shipping charges prepaid,
and with a copy of customer proof of purchase. Tektronix shall pay for the return of the
product to Customer if the shipment is to a location within the country in which the
Tektronix service center is located. Customer shall be responsible for paying all shipping
charges, duties, taxes, and any other charges for products returned to any other locations.
This warranty shall not apply to any defect, failure or damage caused by improper use or
improper or inadequate maintenance and care. Tektronix shall not be obligated to furnish
service under this warranty a) to repair damage resulting from attempts by personnel other
than Tektronix representatives to install, repair or service the product; b) to repair damage
resulting from improper use or connection to incompatible equipment; c) to repair any
damage or malfunction caused by the use of non-Tektronix supplies; or d) to service a
product that has been modified or integrated with other products when the effect of such
modification or integration increases the time or difficulty of servicing the product.
THIS WARRANTY IS GIVEN BY TEKTRONIX WITH RESPECT TO THE
LISTED PRODUCTS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR
IMPLIED. TEKTRONIX AND ITS VENDORS DISCLAIM ANY IMPLIED
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE. TEKTRONIX’ RESPONSIBILITY TO REPAIR OR REPLACE
DEFECTIVE PRODUCTS IS THE SOLE AND EXCLUSIVE REMEDY
PROVIDED TO THE CUSTOMER FOR BREACH OF THIS WARRANTY.
TEKTRONIX AND ITS VENDORS WILL NOT BE LIABLE FOR ANY
INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES
IRRESPECTIVE OF WHETHER TEKTRONIX OR THE VENDOR HAS
ADVANCE NOTICE OF THE POSSIBILITY OF SUCH DAMAGES.
Table of Contents
General Safety Summaryiii............................
NetTek Analyzer YOPM100 & 200 Optical Power Meter Modules
General Safety Summary
Review the following safety precautions to avoid injury and prevent
damage to this product or any produc ts connected to it. To avoid
potential hazards, use this product only as specified.
Only qualified personnel should perform service procedures.
While using this product, you may need to access other parts of the
system. Read the General Safety Summary in other system manuals
for warnings and cautions related to operating the system.
To Avoid Fire or Personal Injury
Do Not Operate Without Covers. Do not operate this product with
covers or panels removed.
Wear Eye Protection. Wear eye protection if exposure to high-intensity
rays or laser radiation exists.
Do Not Operate With Suspected Failures. If you suspect there is damage
to this product, have it inspected by qualified service personnel.
Do Not Operate in Wet/Damp Conditions.
Do Not Operate in an Explosive Atmosphere.
Keep Product Surfaces Clean and Dry.
Safety Terms and Symbols
Terms in This Manual. These terms may appear in this manual:
WARNING. Warning statements identify conditions or practices that
could result in injury or loss of life.
CAUTION. Caution statements identify conditions or practices that
could result in damage to this product or other property.
Terms on the Product. These terms ma y appear on the product:
NetTek Analyzer YOPM100 & 200 Optical Power Meter Modules
iii
General Safety Summary
DANGER indicates an injury hazard immediately accessible as you
read the marking.
WARNING indicates an injury hazard not immediately accessible as
you read the marking.
CAUTION indicates a ha zard to property including the product.
Symbols on the Product. These symbols may appear on the product:
CAUTION
Refer to Manual
Double
Insulated
Protective Ground
(Earth) Terminal
iv
NetTek Analyzer YOPM100 & 200 Optical Power Meter Modules
Preface
This manual contains operating instructions for the NetTek Analyzer
YOPM100 & 200 Optical Power Meters.
Related Documentation
For online help for the power meter, within the YOPM application,
select Help > Help Topics.
The power meter module runs on the Y350C and Y350M NetTek
Analyzer platform. For platform information, refer to the following
resources:
HY350C and Y350M Ne tTek Anal yzer Platform User Manual
HY350C and Y350M Ne tTek Anal yzer Platform Online Help
(Select Start > Help or tap the ? button in a dialog box.)
HWindows CE Operating System Online Help
(Select Start > Help or tap the ? button in a dialog box.)
For OTDR information, refer to the following resources:
HNetTek Analyzer OTDR User Manual
HNetTek Analyzer OTDR Online Help
(Within the OTDR application, select Help > Help Topics... or
tap the ? button in a dialog box.)
NetTek Analyzer YOPM100 & 200 Optical Power Meter Modules
v
Preface
Conventions
This book uses the following convention to represent menus:
To open the help window and find information on a specific topic,
you would be instructed to sele ct Start > Help. To accomplish this,
tap Start in the toolbar at the bottom of the desktop window; then
tap Help in the resulting WindowsCE menu.
Related Products
The Y350C and Y350M NetTek Analyzer Platform supports test
tools including the NetTek Series of OTDRs and the YOPM100 &
200 Optical Power Meters.
Firmware Version
This manual supports firmware version 1.0 and above of the NetTek
Analyzer YOPM100 & 200 Optical Power Meters.
To verify your firmware version, do the following:
1. Open the YOPM application.
2. Select Help > About YOPM....
vi
NetTek Analyzer YOPM100 & 200 Optical Power Meter Modules
Contacting Tektronix
Phone1-800-833-9200*
AddressTektronix, Inc.
Department or name (if known)
14200 SW Karl Braun Drive
P.O. Box 500
Beaverton, OR 97077
USA
Web sitewww.tektronix.com
Preface
Sales support
Service
support
Technical
support
*This phone number is toll free in North America. After office
hours, please leave a voice mail message. Outside North
America, contact a Tektronix sales office or distributor; see the
Tektronix web site for a list of offices.
1-800-833-9200, select option 1*
1-800-833-9200, select option 2*
Email: techsupport@tektronix.com
1-800-833-9200, select option 3*
1-503-627-2400
6:00 a.m. -- 5:00 p.m. Pacific time
NetTek Analyzer YOPM100 & 200 Optical Power Meter Modules
vii
Preface
viii
NetTek Analyzer YOPM100 & 200 Optical Power Meter Modules
Getting Started
Product Description
The PCMCIA-based YOPM100 and the YOPM200 Optical Power
Meters operate with the NetTek Analyzer platform. You can measure
all common telecommunication wavelengths from 850 nm to
1625 nm and easily save the me asurement data to document
networks. YOPM lets you store and view multiple tests in a
configurable table. This lets you match your system pa tch panel
configuration for easy recovery and analysis of measurements. You
can collect and store your measurements in a table that matches the
way your patch pa nel is laid out. You can combine YOPM stored
tests with TARGET1 analysis software to generate complete
installation and maintenance reports.
Table 1 contains general information on components and accessories.
Table 1: Components and accessories
User Manual. Contains information on setup and basic operation.
Disk. Contains instrument software.
NetTek Analyzer YOPM100 & 200 Optical Power Meter Modules
1
Getting Started
Installing YOPM Application
If you ordered your power meter separately from your NetTek
Analyzer, you may need to install the YOPM application onto your
NetTek Analyzer.
If your NetTek Analyzer has a floppy-disk drive, install the software
directly on the NetTek Analyzer. See Installing From the NetTekAnalyzer Built-in Floppy-disk Drive below.
If your NetTek Analyzer does not have a built-in floppy-disk drive,
download the software using the floppy drive on a PC, and then
transfer the file through the serial port to the NetTek Analyzer. See
Installing From a PC Floppy-disk Drive on page 3.
Installing From the NetTek Analyzer Built-in Floppy-disk Drive
(If the correct file is not found, select Browse to manually select
\FloppyDisk\InstallYOPM.arq and press OK.)
4. Select Next. It will take a few moments for the files to be
extracted and installed.
When installation is complete, the dialog box, Module Upgrade
Complete, appears.
5. Remove the floppy disk.
6. Select Restart Now.
2
NetTek Analyzer YOPM100 & 200 Optical Power Meter Modules
Getting Started
Installing From a PC Floppy-disk Drive
Use a desktop computer with a floppy-disk drive and Windows 95,
98, NT 4.0, 2000, or ME operating system.
You will need a serial cable and an available COM port. You also
need to have active WinCE services or an ActiveSync connection to
transfer files. Enable WinCE services using the Windows CE
Services > Communications tab.
1. Connect the NetTek Analyzer to the remote PC:
a. Connect one end of a 9-pin RS-232 null modem cable (a
standard accessory with the NetTek Analyzer) to the serial
(COM) port on the PC. See your computer documentation
for the port location.
b. Connect the other end of the cable to the NetTek Analyzer
serial port. See Figure 1 for the port location.
Serial port
Figure 1: NetTek Analyzer serial port
2. Insert the floppy disk into the floppy drive on the PC.
NetTek Analyzer YOPM100 & 200 Optical Power Meter Modules
3
Getting Started
3. Copy the InstallYOPM.arq fil e from the floppy disk to the
directory: \, on the the NetTek Analyzer. (The directory is called
My NetTek when viewed on the NetTek Analyzer or My
Handheld PC when viewed from the PC. It’s one level above
\BuiltInDisk on the NetTek Analyzer.)
It will take several minutes for the file to transfer.
4. On the NetTek Analyzer, select:
Start > Programs > Tektronix Utilities > Module Upgrade.
5. Select Next. The NetTek Analyzer will not be able to automati-
cally find the module software for installation.
6. Select Browse.
7. Manually select \InstallYOPM.arq and press OK.
8. Select Next. It will take a few moments for the files to be
extracted and installed.
When installation is complete, the dialog box, Module Upgrade
Complete, appears.
9. Select Restart Now.
10. Remove the floppy disk from the PC.
4
NetTek Analyzer YOPM100 & 200 Optical Power Meter Modules
Getting Started
Installing the YOPM100 & 200 Optical Power Meters
To install the power meter, do the following:
CAUTION. Suspend or shut down the NetTek Analyzer before
installing any PC card. Failure to do so could result in loss of user
data due to a system crash.
1. Open the access door on the right side of the analyzer. See
Figure 2.
2. With the PC card label facing the analyzer display, slide the card
end of the power meter i nto the front PCMCIA slot of the NetTek
Analyzer platform as shown.
NOTE. For CE compliance, use the power meter only in the front
PCMCIA slot.
NetTek Analyzer YOPM100 & 200 Optical Power Meter Modules
5
Loading...
+ 37 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.