Tektronix YOPM100, YOPM200 User Manual

User Manual
NetTekt Analyzer YOPM100 & 200 Optical Power Meter Modules
071-0995-00
This document supports software version 1.3 and above.
www.tektronix.com
Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supercedes that in all previously published material. Specifications and price change privileges reserved.
Tektronix, Inc., P.O. Box 500, Beaverton, OR 97077
TEKTRONIX, TEK, and NETTEK are registered trademarks of Tektronix, Inc.

WARRANTY

Tektronix warrants that the products that it manufactures and sells will be free from defects in materials and workmanship for a period of one (1) year from the date of purchase from an authorized Tektronix distributor. If any such product proves defective during this warranty period, Tektronix, at its option, either will repair the defective product without charge for parts and labor, or will provide a replacement in exchange for the defective product. Batteries are excluded from this warranty.
In order to obtain service under this warranty, Customer must notify Tektronix of the defect before the expiration of the warranty period and make suitable arrangements for the performance of service. Customer shall be responsible for packaging and shipping the defective product to the service center designated by Tektronix, shipping charges prepaid, and with a copy of customer proof of purchase. Tektronix shall pay for the return of the product to Customer if the shipment is to a location within the country in which the Tektronix service center is located. Customer shall be responsible for paying all shipping charges, duties, taxes, and any other charges for products returned to any other locations.
This warranty shall not apply to any defect, failure or damage caused by improper use or improper or inadequate maintenance and care. Tektronix shall not be obligated to furnish service under this warranty a) to repair damage resulting from attempts by personnel other than Tektronix representatives to install, repair or service the product; b) to repair damage resulting from improper use or connection to incompatible equipment; c) to repair any damage or malfunction caused by the use of non-Tektronix supplies; or d) to service a product that has been modified or integrated with other products when the effect of such modification or integration increases the time or difficulty of servicing the product.
THIS WARRANTY IS GIVEN BY TEKTRONIX WITH RESPECT TO THE LISTED PRODUCTS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED. TEKTRONIX AND ITS VENDORS DISCLAIM ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. TEKTRONIX’ RESPONSIBILITY TO REPAIR OR REPLACE DEFECTIVE PRODUCTS IS THE SOLE AND EXCLUSIVE REMEDY PROVIDED TO THE CUSTOMER FOR BREACH OF THIS WARRANTY. TEKTRONIX AND ITS VENDORS WILL NOT BE LIABLE FOR ANY INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES IRRESPECTIVE OF WHETHER TEKTRONIX OR THE VENDOR HAS ADVANCE NOTICE OF THE POSSIBILITY OF SUCH DAMAGES.

Table of Contents

General Safety Summary iii............................
Preface v............................................
Related Documentation v...............................
Conventions vi........................................
Related Products vi....................................
Firmware Version vi....................................
Contacting Tektronix vii................................
Getting Started 1.....................................
Product Description 1..................................
Installing YOPM Application 2..........................
Installing From the NetTek Analyzer Built-in
Floppy-disk Drive 2................................
Installing From a PC Floppy-disk Drive 3...............
Installing the YOPM100 & 200 Optical Power Meters 5......
Opening the Application 7..............................
Selecting Wavelengths 9................................
Operating Basics 11...................................
Collecting Measurements 12.............................
Setting the Reference Level 13...........................
Buttons and Menus 15..................................
Using the Online Help 18................................
Configuring the Measurement Table 20.....................
Saving Measurement Files 21.............................
Opening a Measurement File 21...........................
Reference 23.........................................
Exporting Measurement Files 23..........................
Transferring Files to a PC 25.............................
SOC Adapter Removal and Insta llation 26..................
Removing an SOC Adapter 26.........................
Installing an SOC Adapter 26..........................
Cleaning 27...........................................
Cleaning the Detector Window 27......................
Cleaning the Test Fiber Connector 28...................
Cleaning the Exterior of the Power Meter Test Head 28.....
Zeroing the Optical Power Meter 29.......................
NetTek Analyzer YOPM100 & 200 Optical Power Meter Modules
i
Table of Contents
Specifications 31......................................
Options, Accessories, and Replaceable Parts 35............
T ransporting or Shipping 37............................
Repackaging for Shipment 38............................
Index 39.............................................

List of Tables

Table 1: Components and accessories 1..................
Table 2: Main screen buttons 15.........................
Table 3: File Menu 16.................................
Table 4: Settings Menu 17..............................
Table 5: Help Menu 18................................
Table 6: Help window buttons 19........................
Table 7: NetTek Analyzer YOPM module characteristics 31.
Table 8: Physical characteristics 31......................
Table 9: General characteristics 32......................
Table 10: Environmental characteristics 32...............
Table 11: Certifications and compliances 33...............
Table 12: SOC connector part numbers 35................
Table 13: Standard accessories 35.......................
Table 14: Replaceable Part 35..........................
ii
NetTek Analyzer YOPM100 & 200 Optical Power Meter Modules

General Safety Summary

Review the following safety precautions to avoid injury and prevent damage to this product or any produc ts connected to it. To avoid potential hazards, use this product only as specified.
Only qualified personnel should perform service procedures.
While using this product, you may need to access other parts of the system. Read the General Safety Summary in other system manuals for warnings and cautions related to operating the system.
To Avoid Fire or Personal Injury
Do Not Operate Without Covers. Do not operate this product with
covers or panels removed.
Wear Eye Protection. Wear eye protection if exposure to high-intensity
rays or laser radiation exists.
Do Not Operate With Suspected Failures. If you suspect there is damage
to this product, have it inspected by qualified service personnel.
Do Not Operate in Wet/Damp Conditions.
Do Not Operate in an Explosive Atmosphere.
Keep Product Surfaces Clean and Dry.
Safety Terms and Symbols
Terms in This Manual. These terms may appear in this manual:
WARNING. Warning statements identify conditions or practices that could result in injury or loss of life.
CAUTION. Caution statements identify conditions or practices that could result in damage to this product or other property.
Terms on the Product. These terms ma y appear on the product:
NetTek Analyzer YOPM100 & 200 Optical Power Meter Modules
iii
General Safety Summary
DANGER indicates an injury hazard immediately accessible as you read the marking.
WARNING indicates an injury hazard not immediately accessible as you read the marking.
CAUTION indicates a ha zard to property including the product.
Symbols on the Product. These symbols may appear on the product:
CAUTION
Refer to Manual
Double
Insulated
Protective Ground
(Earth) Terminal
iv
NetTek Analyzer YOPM100 & 200 Optical Power Meter Modules

Preface

This manual contains operating instructions for the NetTek Analyzer YOPM100 & 200 Optical Power Meters.

Related Documentation

For online help for the power meter, within the YOPM application, select Help > Help Topics.
The power meter module runs on the Y350C and Y350M NetTek Analyzer platform. For platform information, refer to the following resources:
H Y350C and Y350M Ne tTek Anal yzer Platform User Manual
H Y350C and Y350M Ne tTek Anal yzer Platform Online Help
(Select Start > Help or tap the ? button in a dialog box.)
H Windows CE Operating System Online Help
(Select Start > Help or tap the ? button in a dialog box.)
For OTDR information, refer to the following resources:
H NetTek Analyzer OTDR User Manual
H NetTek Analyzer OTDR Online Help
(Within the OTDR application, select Help > Help Topics... or
tap the ? button in a dialog box.)
NetTek Analyzer YOPM100 & 200 Optical Power Meter Modules
v
Preface

Conventions

This book uses the following convention to represent menus:
To open the help window and find information on a specific topic, you would be instructed to sele ct Start > Help. To accomplish this, tap Start in the toolbar at the bottom of the desktop window; then tap Help in the resulting WindowsCE menu.

Related Products

The Y350C and Y350M NetTek Analyzer Platform supports test tools including the NetTek Series of OTDRs and the YOPM100 & 200 Optical Power Meters.

Firmware Version

This manual supports firmware version 1.0 and above of the NetTek Analyzer YOPM100 & 200 Optical Power Meters.
To verify your firmware version, do the following:
1. Open the YOPM application.
2. Select Help > About YOPM....
vi
NetTek Analyzer YOPM100 & 200 Optical Power Meter Modules

Contacting Tektronix

Phone 1-800-833-9200*
Address Tektronix, Inc.
Department or name (if known) 14200 SW Karl Braun Drive P.O. Box 500 Beaverton, OR 97077 USA
Web site www.tektronix.com
Preface
Sales sup­port
Service support
Technical support
* This phone number is toll free in North America. After office
hours, please leave a voice mail message. Outside North America, contact a Tektronix sales office or distributor; see the Tektronix web site for a list of offices.
1-800-833-9200, select option 1*
1-800-833-9200, select option 2*
Email: techsupport@tektronix.com
1-800-833-9200, select option 3* 1-503-627-2400
6:00 a.m. -- 5:00 p.m. Pacific time
NetTek Analyzer YOPM100 & 200 Optical Power Meter Modules
vii
Preface
viii
NetTek Analyzer YOPM100 & 200 Optical Power Meter Modules

Getting Started

Product Description

The PCMCIA-based YOPM100 and the YOPM200 Optical Power Meters operate with the NetTek Analyzer platform. You can measure all common telecommunication wavelengths from 850 nm to 1625 nm and easily save the me asurement data to document networks. YOPM lets you store and view multiple tests in a configurable table. This lets you match your system pa tch panel configuration for easy recovery and analysis of measurements. You can collect and store your measurements in a table that matches the way your patch pa nel is laid out. You can combine YOPM stored tests with TARGET1 analysis software to generate complete installation and maintenance reports.
Table 1 contains general information on components and accessories.
Table 1: Components and accessories
User Manual. Contains information on setup and basic operation.
Disk. Contains instrument software.
NetTek Analyzer YOPM100 & 200 Optical Power Meter Modules
1
Getting Started

Installing YOPM Application

If you ordered your power meter separately from your NetTek Analyzer, you may need to install the YOPM application onto your NetTek Analyzer.
If your NetTek Analyzer has a floppy-disk drive, install the software directly on the NetTek Analyzer. See Installing From the NetTek Analyzer Built-in Floppy-disk Drive below.
If your NetTek Analyzer does not have a built-in floppy-disk drive, download the software using the floppy drive on a PC, and then transfer the file through the serial port to the NetTek Analyzer. See Installing From a PC Floppy-disk Drive on page 3.
Installing From the NetTek Analyzer Built-in Floppy-disk Drive
1. Select Start > Programs > Tektronix Utilities > Module Upgrade.
2. Insert the floppy. Select Next.
3. The dialog box, Continuing Upgrade Process, will appear stating
“Found Upgrade File: \FloppyDisk\InstallYOPM.arq.”
(If the correct file is not found, select Browse to manually select
\FloppyDisk\InstallYOPM.arq and press OK.)
4. Select Next. It will take a few moments for the files to be
extracted and installed.
When installation is complete, the dialog box, Module Upgrade Complete, appears.
5. Remove the floppy disk.
6. Select Restart Now.
2
NetTek Analyzer YOPM100 & 200 Optical Power Meter Modules
Getting Started
Installing From a PC Floppy-disk Drive
Use a desktop computer with a floppy-disk drive and Windows 95, 98, NT 4.0, 2000, or ME operating system.
You will need a serial cable and an available COM port. You also need to have active WinCE services or an ActiveSync connection to transfer files. Enable WinCE services using the Windows CE Services > Communications tab.
1. Connect the NetTek Analyzer to the remote PC:
a. Connect one end of a 9-pin RS-232 null modem cable (a
standard accessory with the NetTek Analyzer) to the serial (COM) port on the PC. See your computer documentation for the port location.
b. Connect the other end of the cable to the NetTek Analyzer
serial port. See Figure 1 for the port location.
Serial port
Figure 1: NetTek Analyzer serial port
2. Insert the floppy disk into the floppy drive on the PC.
NetTek Analyzer YOPM100 & 200 Optical Power Meter Modules
3
Getting Started
3. Copy the InstallYOPM.arq fil e from the floppy disk to the directory: \, on the the NetTek Analyzer. (The directory is called My NetTek when viewed on the NetTek Analyzer or My Handheld PC when viewed from the PC. It’s one level above \BuiltInDisk on the NetTek Analyzer.)
It will take several minutes for the file to transfer.
4. On the NetTek Analyzer, select: Start > Programs > Tektronix Utilities > Module Upgrade.
5. Select Next. The NetTek Analyzer will not be able to automati-
cally find the module software for installation.
6. Select Browse.
7. Manually select \InstallYOPM.arq and press OK.
8. Select Next. It will take a few moments for the files to be
extracted and installed.
When installation is complete, the dialog box, Module Upgrade Complete, appears.
9. Select Restart Now.
10. Remove the floppy disk from the PC.
4
NetTek Analyzer YOPM100 & 200 Optical Power Meter Modules
Getting Started

Installing the YOPM100 & 200 Optical Power Meters

To install the power meter, do the following:
CAUTION. Suspend or shut down the NetTek Analyzer before installing any PC card. Failure to do so could result in loss of user data due to a system crash.
1. Open the access door on the right side of the analyzer. See
Figure 2.
2. With the PC card label facing the analyzer display, slide the card
end of the power meter i nto the front PCMCIA slot of the NetTek Analyzer platform as shown.
NOTE. For CE compliance, use the power meter only in the front PCMCIA slot.
NetTek Analyzer YOPM100 & 200 Optical Power Meter Modules
5
Loading...
+ 37 hidden pages