Tektronix TMSPGB Instruction Manual

Instruction Manual

TMS PGB FC-PGA Hardware Support

071-0478-02
Warning
The servicing instructions are for use by qualified personnel only. To avoid personal injury, do not perform any servicing unless you are qualified to do so. Refer to all safety summaries prior to performing service.
www.tektronix.com

Copyright © T ektronix, Inc. All rights reserved. T ektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supercedes

that in all previously published material. Specifications and price change privileges reserved. T ektronix, Inc., P.O. Box 500, Beaverton, OR 97077 TEKTRONIX and TEK are registered trademarks of T ektronix, Inc.

HARDWARE WARRANTY

T ektronix warrants that the products that it manufactures and sells will be free from defects in materials and workmanship for a period of one (1) year from the date of shipment. If a product proves defective during this warranty period, T ektronix, at its option, either will repair the defective product without charge for parts and labor, or will provide a replacement in exchange for the defective product.
In order to obtain service under this warranty, Customer must notify Tektronix of the defect before the expiration of the warranty period and make suitable arrangements for the performance of service. Customer shall be responsible for packaging and shipping the defective product to the service center designated by T ektronix, with shipping charges prepaid. Tektronix shall pay for the return of the product to Customer if the shipment is to a location within the country in which the T ektronix service center is located. Customer shall be responsible for paying all shipping charges, duties, taxes, and any other charges for products returned to any other locations.
This warranty shall not apply to any defect, failure or damage caused by improper use or improper or inadequate maintenance and care. T ektronix shall not be obligated to furnish service under this warranty a) to repair damage resulting from attempts by personnel other than T ektronix representatives to install, repair or service the product; b) to repair damage resulting from improper use or connection to incompatible equipment; c) to repair any damage or malfunction caused by the use of non-T ektronix supplies; or d) to service a product that has been modified or integrated with other products when the effect of such modification or integration increases the time or difficulty of servicing the product.
THIS WARRANTY IS GIVEN BY TEKTRONIX IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED. TEKTRONIX AND ITS VENDORS DISCLAIM ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. TEKTRONIX’ RESPONSIBILITY TO REPAIR OR REPLACE DEFECTIVE PRODUCTS IS THE SOLE AND EXCLUSIVE REMEDY PROVIDED TO THE CUST OMER FOR BREACH OF THIS WARRANTY. TEKTRONIX AND ITS VENDORS WILL NOT BE LIABLE FOR ANY INDIRECT , SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES IRRESPECTIVE OF WHETHER TEKTRONIX OR THE VENDOR HAS ADVANCE NOTICE OF THE POSSIBILITY OF SUCH DAMAGES.

Table of Contents

Getting Started
General Safety Summary v. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Service Safety Summary vii. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Preface ix. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Manual Conventions ix. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Contacting T ektronix x. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Support Package Description 1–1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Support Software Compatibility 1–1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Logic Analyzer Configuration 1–1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Requirements and Restrictions 1–2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Labeling P6434 Probes 1–3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Assembling the Probe Adapter 1–4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Configuring The Probe Adapter 1–6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TIMING/NORMAL Jumper 1–6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
MFG_TEST Jumper 1–6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Connecting the Logic Analyzer to a System Under T est 1–7. . . . . . . . . . . . . . . . .
Alternate Connections 1–12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Applying and Removing Power 1–15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CPU To Mictor Connections 1–17. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Specifications
Maintenance
Replaceable Parts List
Index
Circuit Description 2–1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Probe Adapter Loading Diagrams 2–2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Specification T ables 2–4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Replacing The Fuse 3–1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Parts Ordering Information 4–1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Using the Replaceable Mechanical Parts 4–1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TMS PGB FC-PGA Hardware Support
i
Table of Contents

List of Figures

Figure 1–1: Seating the 190-pin mictor connector 1–4. . . . . . . . . . . . . . . .
Figure 1–2: Attaching the Logic board to the Interposer board 1–5. . . . .
Figure 1–3: Jumper locations on the FC-PGA probe adapter 1–6. . . . . .
Figure 1–4: Connecting a probe to the probe adapter 1–8. . . . . . . . . . . . .
Figure 1–5: Sacrificial sockets 1–9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 1–6: Inserting a sacrificial socket into the ZIF socket 1–9. . . . . . .
Figure 1–7: Inserting the probe adapter into the sacrificial socket 1–10. . Figure 1–8: Placing the FC-PGA microprocessor into the
probe adapter 1–11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 1–9: APIC bus pins location on the probe adapter 1–12. . . . . . . . .
Figure 1–10: ITP pin locations on the probe adapter logic board 1–13. . .
Figure 1–11: Test point locations on the probe adapter 1–14. . . . . . . . . . . .
Figure 1–12: Location of the power jack 1–16. . . . . . . . . . . . . . . . . . . . . . . .
Figure 1–13: Pin assignments for a Mictor connector
(component side) 1–17. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 2–1: FC-PGA signals without active loads 2–2. . . . . . . . . . . . . . . .
Figure 2–2: FC-PGA signals with active loads 2–2. . . . . . . . . . . . . . . . . . .
Figure 2–3: FC-PGA BCLK 2–2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 2–4: Detail of FC-PGA sockets and 190-pin mictor connector. 2–3
Figure 2–5: Equivalent circuit for the P6434 probe 2–4. . . . . . . . . . . . . . .
Figure 2–6: Dimensions of the FC-PGA probe adapter 2–7. . . . . . . . . . .
Figure 3–1: Fuse location on the FC-PGA probe adapter 3–1. . . . . . . . . .
ii
TMS PGB FC-PGA Hardware Support

List of Tables

Table of Contents
Table 1–1: APIC information 1–12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 1–2: Testpoint (J510) information 1–13. . . . . . . . . . . . . . . . . . . . . . .
Table 1–3: Test point (J700) information 1–14. . . . . . . . . . . . . . . . . . . . . .
Table 1–4: Clock Channels (stored in the acquisition memory) 1–17. . . .
Table 1–5: Qualifier Channels (stored in the acquisition memory) 1–18. .
Table 1–6: CPU to Mictor connections for Mictor C pins (high) 1–18. . . .
Table 1–7: CPU to Mictor connections for Mictor A pins (high) 1–19. . . .
Table 1–8: CPU to Mictor connections for Mictor D pins (high) 1–20. . . .
Table 1–9: CPU to Mictor connections for Mictor C pins (Low) 1–21. . . .
Table 1–10: CPU to Mictor connections for Mictor A pins (Low) 1–23. . . Table 1–11: CPU to Mictor connections for Mictor D pins (Low) 1–24. . .
Table 2–1: Lossy delay line values 2–3. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 2–2: Electrical specifications for the system under test 2–4. . . . . .
Table 2–3: Electrical specifications for the AC adapter 2–5. . . . . . . . . . .
Table 2–4: Environmental specifications 2–5. . . . . . . . . . . . . . . . . . . . . . .
Table 2–5: BCLK timing and electrical specifications 2–6. . . . . . . . . .
TMS PGB FC-PGA Hardware Support
iii
Table of Contents
iv
TMS PGB FC-PGA Hardware Support

General Safety Summary

Review the following safety precautions to avoid injury and prevent damage to this product or any products connected to it. To avoid potential hazards, use this product only as specified.
Only qualified personnel should perform service procedures.
While using this product, you may need to access other parts of the system. Read the General Safety Summary in other system manuals for warnings and cautions related to operating the system.

To Avoid Fire or Personal Injury

Use Proper Power Cord. Use only the power cord specified for this product and
certified for the country of use. Connect and Disconnect Properly . Do not connect or disconnect probes or test
leads while they are connected to a voltage source. Ground the Product. This product is indirectly grounded through the grounding
conductor of the mainframe power cord. To avoid electric shock, the grounding conductor must be connected to earth ground. Before making connections to the input or output terminals of the product, ensure that the product is properly grounded.
Observe All Terminal Ratings. To avoid fire or shock hazard, observe all ratings and marking on the product. Consult the product manual for further ratings information before making connections to the product.
The common terminal is at ground potential. Do not connect the common terminal to elevated voltages.
Do not apply a potential to any terminal, including the common terminal, that exceeds the maximum rating of that terminal.
Use Proper AC Adapter. Use only the AC adapter specified for this product. Do Not Operate Without Covers. Do not operate this product with covers or panels
removed.
Use Proper Fuse. Use only the fuse type and rating specified for this product. Avoid Exposed Circuitry. Do not touch exposed connections and components
when power is present. Do Not Operate With Suspected Failures. If you suspect there is damage to this
product, have it inspected by qualified service personnel.
Do Not Operate in Wet/Damp Conditions. Do Not Operate in an Explosive Atmosphere.
TMS PGB FC-PGA Hardware Support
v
General Safety Summary
Keep Product Surfaces Clean and Dry . Provide Proper Ventilation. Refer to the manuals installation instructions for
details on installing the product so it has proper ventilation.

Symbols and Terms

T erms in this Manual. These terms may appear in this manual:
WARNING. Warning statements identify conditions or practices that could result in injury or loss of life.
CAUTION. Caution statements identify conditions or practices that could result in damage to this product or other property.
T erms on the Product. These terms may appear on the product: DANGER indicates an injury hazard immediately accessible as you read the
marking. WARNING indicates an injury hazard not immediately accessible as you read the
marking. CAUTION indicates a hazard to property including the product.
Symbols on the Product. The following symbols may appear on the product:
vi
WARNING
High Voltage
Protective Ground
(Earth) T erminal
CAUTION
Refer to Manual
Double
Insulated
TMS PGB FC-PGA Hardware Support

Service Safety Summary

Only qualified personnel should perform service procedures. Read this Service Safety Summary and the General Safety Summary before performing any service
procedures. Do Not Service Alone. Do not perform internal service or adjustments of this
product unless another person capable of rendering first aid and resuscitation is present.
Disconnect Power. To avoid electric shock, switch off the instrument power, then disconnect the power cord from the mains power.
Use Care When Servicing With Power On. Dangerous voltages or currents may exist in this product. Disconnect power, remove battery (if applicable), and disconnect test leads before removing protective panels, soldering, or replacing components.
To avoid electric shock, do not touch exposed connections.
TMS PGB FC-PGA Hardware Support
vii
Service Safety Summary
viii
TMS PGB FC-PGA Hardware Support

Preface

This instruction manual contains specific information about the TMS PGB FC­PGA microprocessor support package and is part of a set of information on how to operate this product on compatible Tektronix logic analyzers.
If you are familiar with operating microprocessor support packages on the logic analyzer for which the TMS PGB FC-PGA support was purchased, you will only need this instruction manual to set up and run the support.
If you are not familiar with operating microprocessor support packages, you will need to supplement this instruction manual with information on basic operations to set up and run the support.
This manual provides detailed information on the following topics:
H Assembling and configuring the probe adapter H Connecting the logic analyzer to the system under test H Applying power and operating the probe adapter

Manual Conventions

This manual uses the following conventions: H The term “module refers to two 102-channel modules, a 102-channel
module plus a 136-channel module, or two 136-channel modules.
H A pound sign (#) following a signal name indicates an active low signal. H The phrase information on basic operations refers to basic information in
your online help.
H The term “HI module refers to the module in the higher-numbered slot and
the term LO module refers to the module in the lower-numbered slot.
TMS PGB FC-PGA Hardware Support
ix
Preface

Contacting Tektronix

Phone 1-800-833-9200*
Address Tektronix, Inc.
Department or name (if known) 14200 SW Karl Braun Drive P.O. Box 500 Beaverton, OR 97077 USA
Web site www.tektronix.com
Sales support 1-800-833-9200, select option 1*
Service support 1-800-833-9200, select option 2*
Technical support Email: support@tektronix.com
1-800-833-9200, select option 3* 1-503-627-2400
6:00 a.m. – 5:00 p.m. Pacific time
* This phone number is toll free in North America. After office hours, please leave a
voice mail message. Outside North America, contact a Tektronix sales office or distributor; see the Tektronix web site for a list of offices.
x
TMS PGB FC-PGA Hardware Support
Getting Started

Getting Started

This chapter contains information on the TMS PGB FC-PGA hardware support package, and information on connecting your logic analyzer to your system under test.

Support Package Description

The FC-PGA probe adapter is nonintrusive hardware that allows the logic analyzer to acquire data from a microprocessor in its own operating environment with little effect on that system.
The FC-PGA probe adapter is an interposer design. The probe adapter connects to the system under test, and then, the microprocessor connects to the probe adapter. Signals from the microprocessor-based system flow through the probe adapter into the P6434 probes and through the probe cables to the logic analyzer.

Support Software Compatibility

The FC-PGA probe adapter requires a Tektronix microprocessor software support package. Contact your Tektronix representative to determine which software support package is compatible with the FC-PGA probe adapter.
If this product is used with the TMS 113 Software Support package, select the PG370 clocking selection.

Logic Analyzer Configuration

To use the TMS PGB FC-PGA hardware support package you need a Tektronix logic analyzer equipped with two 102-channel modules. The modules must be in adjacent slots and merged.
References to a 204-channel module include the two 102-channel modules that are merged and any other merged module combination of a minimum of 204-channels (for the merged combination).
You can acquire ITP and APIC bus activity through the FC-PGA probe adapter. Probing the APIC bus requires the TMS 801 APIC bus support package, a third 102-channel acquisition module, and standard probes. See Alternate Connections on page 1–12 for more details.
TMS PGB FC-PGA Hardware Support
1–1
Getting Started

Requirements and Restrictions

CAUTION. Forced air cooling must be used to keep the microprocessor from overheating.
You should review the general requirements and restrictions of microprocessor support packages in the information on basic operations as they pertain to your system under test.
You should also review electrical, environmental, and mechanical specifications in Specifications on page 2–1 as they pertain to your system under test, as well as the following descriptions of other TMS PGB FC-PGA hardware support requirements and restrictions.

System Clock Rate

BCLK

System Under Test Power

The TMS PGB FC-PGA microprocessor support can acquire data from front side buses operating at speeds of up to 100 MHz.
The operating clock rate specifications were measured at the time of printing. Contact your Tektronix sales representative for current information on the fastest devices supported.
Refer to the BCLK specifications and restrictions listed in Table 2–5 on page 2–6, in the Specifications chapter.
Whenever you power off the system under test, remove power from the probe adapter. Refer to Applying and Removing Power on page 1–15.
1–2
TMS PGB FC-PGA Hardware Support
Getting Started

Signals Supported

The following signals are supported by the FC-PGA probe adapter:
A[31:3]# FLUSH# RS[2:0]#
A20M# HIT# SLP#
ADS# HITM# SMI#
BCLK IERR# STPCLK#
BNR# IGNNE# TCK
BP[3:2]# INIT# TDI
BPM[1:0]# LINT[1:0] TDO
BPRI# LOCK# THERMDN
BR0# PICCLK THERMDP
BSEL# PICD[1:0] THERMTRIP#
D[63:0]# PRDY# TMS
DBSY# PREQ# TRDY#
DEFER# PWRGOOD TRST#
DRDY# REQ[4:0]#
FERR# RESET#

Labeling P6434 Probes

Contact your Tektronix sales representative for other supported signals not shown in the preceding list.
The TMS PGB FC-PGA hardware support package relies on the standard channel mapping and labeling scheme for P6434 probes. Apply labels using the standard method described in the P6434 Mass Termination Probe Instructions.
TMS PGB FC-PGA Hardware Support
1–3
Getting Started

Assembling the Probe Adapter

The probe adapter assembly consists of a Logic board, Interposer board, and screws.
CAUTION. Static discharge can damage the microprocessor, the probe adapter, the probes, and the module. To prevent static damage, handle components only in a static-free environment.
Always wear a grounding wrist strap, heel strap, or similar device while handling the microprocessor and probe adapter.
Do the following steps to assemble the probe adapter:
1. To discharge any static electricity, touch the ground connector located on the
logic analyzer. Then, before you remove the probe adapter circuit boards
from their protective bags, touch each bag to discharge stored static
electricity.
2. Align the Logic board connector pins with the Interposer board connector
pins, and press firmly to seat the board connector (see Figure 1–1). Both
connectors are polarized and will only mate in one orientation.
NOTE. To ensure a reliable electrical connection between the Logic board and the Interposer board the 190-pin mictor connector must be completely seated at both ends (see Figure 1–1).
Logic board
The top of the plug is not level with the top of receptacle
Gap
190-pin mictor
Interposer
board
Correct
The top of the plug is level with the top of receptacle
No gap on either end
Incorrect
1–4
Figure 1–1: Seating the 190-pin mictor connector