Tektronix TMS871 Instruction Manual

Instruction Manual
TMS 871 1394 Bus Support Package
071-0637-00
There are no current European directives that apply to this product. This product provides cable and test lead connections to a test object of electronic measuring and test equipment.
The servicing instructions are for use by qualified personnel only. To avoid personal injury, do not perform any servicing unless you are qualified to do so. Refer to all safety summaries prior to performing service.

Copyright E T ektronix, Inc. All rights reserved. Licensed software products are owned by Tektronix or its suppliers and are protected by United States copyright laws and international treaty provisions.

Use, duplication, or disclosure by the Government is subject to restrictions as set forth in subparagraph (c)(1)(ii) of the Rights in T echnical Data and Computer Software clause at DFARS 252.227-7013, or subparagraphs (c)(1) and (2) of the Commercial Computer Software – Restricted Rights clause at F AR 52.227-19, as applicable.
T ektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supercedes that in all previously published material. Specifications and price change privileges reserved.
T ektronix, Inc., P.O. Box 1000, Wilsonville, OR 97070–1000
TEKTRONIX and TEK are registered trademarks of T ektronix, Inc.

SOFTWARE WARRANTY

T ektronix warrants that the media on which this software product is furnished and the encoding of the programs on the media will be free from defects in materials and workmanship for a period of three (3) years from the date of shipment. If a medium or encoding proves defective during the warranty period, T ektronix will provide a replacement in exchange for the defective medium. Except as to the media on which this software product is furnished, this software product is provided “as is” without warranty of any kind, either express or implied. T ektronix does not warrant that the functions contained in this software product will meet Customer’s requirements or that the operation of the programs will be uninterrupted or error-free.
In order to obtain service under this warranty, Customer must notify Tektronix of the defect before the expiration of the warranty period. If T ektronix is unable to provide a replacement that is free from defects in materials and workmanship within a reasonable time thereafter, Customer may terminate the license for this software product and return this software product and any associated materials for credit or refund.
THIS WARRANTY IS GIVEN BY TEKTRONIX IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED. TEKTRONIX AND ITS VENDORS DISCLAIM ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. TEKTRONIX’ RESPONSIBILITY TO REPLACE DEFECTIVE MEDIA OR REFUND CUSTOMER’S PAYMENT IS THE SOLE AND EXCLUSIVE REMEDY PROVIDED TO THE CUSTOMER FOR BREACH OF THIS WARRANTY. TEKTRONIX AND ITS VENDORS WILL NOT BE LIABLE FOR ANY INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES IRRESPECTIVE OF WHETHER TEKTRONIX OR THE VENDOR HAS ADVANCE NOTICE OF THE POSSIBILITY OF SUCH DAMAGES.

HARDWARE WARRANTY

T ektronix warrants that the products that it manufactures and sells will be free from defects in materials and workmanship for a period of one (1) year from the date of shipment. If a product proves defective during this warranty period, T ektronix, at its option, either will repair the defective product without charge for parts and labor, or will provide a replacement in exchange for the defective product.
In order to obtain service under this warranty, Customer must notify Tektronix of the defect before the expiration of the warranty period and make suitable arrangements for the performance of service. Customer shall be responsible for packaging and shipping the defective product to the service center designated by T ektronix, with shipping charges prepaid. Tektronix shall pay for the return of the product to Customer if the shipment is to a location within the country in which the T ektronix service center is located. Customer shall be responsible for paying all shipping charges, duties, taxes, and any other charges for products returned to any other locations.
This warranty shall not apply to any defect, failure or damage caused by improper use or improper or inadequate maintenance and care. T ektronix shall not be obligated to furnish service under this warranty a) to repair damage resulting from attempts by personnel other than T ektronix representatives to install, repair or service the product; b) to repair damage resulting from improper use or connection to incompatible equipment; c) to repair any damage or malfunction caused by the use of non-T ektronix supplies; or d) to service a product that has been modified or integrated with other products when the effect of such modification or integration increases the time or difficulty of servicing the product.
THIS WARRANTY IS GIVEN BY TEKTRONIX IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED. TEKTRONIX AND ITS VENDORS DISCLAIM ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. TEKTRONIX’ RESPONSIBILITY TO REPAIR OR REPLACE DEFECTIVE PRODUCTS IS THE SOLE AND EXCLUSIVE REMEDY PROVIDED TO THE CUST OMER FOR BREACH OF THIS WARRANTY. TEKTRONIX AND ITS VENDORS WILL NOT BE LIABLE FOR ANY INDIRECT , SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES IRRESPECTIVE OF WHETHER TEKTRONIX OR THE VENDOR HAS ADVANCE NOTICE OF THE POSSIBILITY OF SUCH DAMAGES.

Table of Contents

Getting Started

Operating Basics

Preface ix. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Manual Conventions ix. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Logic Analyzer Documentation ix. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Contacting T ektronix x. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Support Description 1–2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Logic Analyzer Software Compatibility 1–2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Standard Accessories 1–2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Options 1–2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Requirements and Restrictions 1–3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Connecting to a System Under T est 1–3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Setting Up the Support 2–1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Channel Group Definitions 2–1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Symbols 2–2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Acquiring and Viewing Data 2–7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Acquiring Data 2–7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Trigger Setups 2–7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Custom Clocking 2–9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Display Options 2–10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Displaying Data 2–11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1394 Bus Packets 2–16. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Specifications

Probe Adapter Description 3–1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Probe Adapter Functions 3–2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Specifications 3–2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Channel Assignments 3–4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Signal Descriptions 3–9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Functional Verification

Functional Verification 4–1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Probe Adapter Circuit Description 4–1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Equipment Required 4–1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Verifying Clock Activity Using an Oscilloscope 4–2. . . . . . . . . . . . . . . . . . . . . . . . .
Verifying Probe Adapter Functionality with the TLA System Activity Monitor 4–3
Troubleshooting 4–4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Replaceable Parts

Parts Ordering Information 5–1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Using the Replaceable Parts List 5–1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TMS 871 1394 Bus Support Package Instruction Manual
i
Table of Contents

List of Figures

Figure 1–1: TMS 871 support package 1–1. . . . . . . . . . . . . . . . . . . . . . . . .
Figure 1–2: Connecting the cables to the probe adapter 1–4. . . . . . . . . . .
Figure 1–3: Complete test setup 1–5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 2–1: Trigger Setup Window 2–8. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 2–2: All Fields Display 2–12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 2–3: Selected Fields Display 2–13. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 2–4: Truncated Data in a Selected Field 2–14. . . . . . . . . . . . . . . . . .
Figure 2–5: Packet Header Display 2–15. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 2–6: Packet Type Display 2–16. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Figure 3–1: Dimensions of the probe adapter 3–3. . . . . . . . . . . . . . . . . . . .
Figure 4–1: SCLK/2 (system clock) signal test point 4–2. . . . . . . . . . . . . .
Figure 4–2: Activity pattern 4–3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ii
TMS 871 1394 Bus Support Package Instruction Manual

List of Tables

Table of Contents
Table 2–1: Displayed Channel Groups 2–1. . . . . . . . . . . . . . . . . . . . . . . . .
Table 2–2: Error group symbol table definitions 2–2. . . . . . . . . . . . . . . .
Table 2–3: Event group symbol table definitions 2–3. . . . . . . . . . . . . . . .
Table 2–4: PCtrl group symbol table definitions 2–3. . . . . . . . . . . . . . . . .
Table 2–5: Speed group symbol table definitions 2–4. . . . . . . . . . . . . . . .
Table 2–6: Type group symbol table definitions 2–4. . . . . . . . . . . . . . . . .
Table 2–7: Last_Data group symbol table definitions 2–5. . . . . . . . . . . . .
Table 2–8: Tcode group symbol table definitions 2–5. . . . . . . . . . . . . . . .
Table 3–1: Electrical specifications 3–2. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 3–2: Environmental specifications* 3–3. . . . . . . . . . . . . . . . . . . . . .
Table 3–3: Certifications and compliances 3–3. . . . . . . . . . . . . . . . . . . . . .
Table 3–4: Channel group display order 3–4. . . . . . . . . . . . . . . . . . . . . . .
Table 3–5: Quad_Data group assignments 3–5. . . . . . . . . . . . . . . . . . . . . .
Table 3–6: Speed group assignments 3–6. . . . . . . . . . . . . . . . . . . . . . . . . .
Table 3–7: Type group assignments 3–6. . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 3–8: Event group assignments 3–6. . . . . . . . . . . . . . . . . . . . . . . . . .
Table 3–9: Error group assignments 3–7. . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 3–10: Count group assignments 3–7. . . . . . . . . . . . . . . . . . . . . . . . .
Table 3–11: Last_Data group assignments 3–7. . . . . . . . . . . . . . . . . . . . . .
Table 3–12: Phy_Data group assignments 3–8. . . . . . . . . . . . . . . . . . . . . .
Table 3–13: Phy_Ctrl group assignments 3–8. . . . . . . . . . . . . . . . . . . . . . .
Table 3–14: Clock and qualifier channel assignments 3–8. . . . . . . . . . . .
Table 3–15: Signal descriptions 3–9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table 4–1: Equipment list 4–1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TMS 871 1394 Bus Support Package Instruction Manual
iii
Table of Contents
iv
TMS 871 1394 Bus Support Package Instruction Manual

General Safety Summary

Review the following safety precautions to avoid injury and prevent damage to this product or any products connected to it. To avoid potential hazards, use this product only as specified.
Only qualified personnel should perform service procedures.

To Avoid Fire or Personal Injury

Symbols and Terms

Connect and Disconnect Properly . Connect the probe output to the measurement
instrument before connecting the probe to the circuit under test. Disconnect the probe input from the circuit under test before disconnecting the probe from the measurement instrument.
Observe All Terminal Ratings. To avoid fire or shock hazard, observe all ratings and marking on the product. Consult the product manual for further ratings information before making connections to the product.
Do Not Operate With Suspected Failures. If you suspect there is damage to this product, have it inspected by qualified service personnel.
Do Not Operate in Wet/Damp Conditions. Do Not Operate in an Explosive Atmosphere. Keep Product Surfaces Clean and Dry .
T erms in this Manual. These terms may appear in this manual:
WARNING. Warning statements identify conditions or practices that could result in injury or loss of life.
CAUTION. Caution statements identify conditions or practices that could result in damage to this product or other property.
TMS 871 1394 Bus Support Package Instruction Manual
v
General Safety Summary
T erms on the Product. These terms may appear on the product: DANGER indicates an injury hazard immediately accessible as you read the
marking. WARNING indicates an injury hazard not immediately accessible as you read the
marking. CAUTION indicates a hazard to property including the product. Symbols on the Product. The following symbols may appear on the product:
Protective Ground
(Earth) T erminal
CAUTION
Refer to Manual
Double
Insulated
vi
TMS 871 1394 Bus Support Package Instruction Manual

Service Safety Summary

Only qualified personnel should perform service procedures. Read this Service Safety Summary and the General Safety Summary before performing any service
procedures. Do Not Service Alone. Do not perform internal service or adjustments of this
product unless another person capable of rendering first aid and resuscitation is present.
Disconnect Power. To avoid electric shock, disconnect the main power by means of the power cord or, if provided, the power switch.
Use Care When Servicing With Power On. Dangerous voltages or currents may exist in this product. Disconnect power, remove battery (if applicable), and disconnect test leads before removing protective panels, soldering, or replacing components.
To avoid electric shock, do not touch exposed connections.
TMS 871 1394 Bus Support Package Instruction Manual
vii
Service Safety Summary
viii
TMS 871 1394 Bus Support Package Instruction Manual

Preface

This instruction manual contains specific information about the TMS 871 1394 Bus support package and is part of a set of information on how to operate this product on compatible Tektronix logic analyzers.
If you are familiar with operating support packages on the logic analyzer for which the TMS 871 1394 Bus support was purchased, you will probably only need this instruction manual to set up and run the support.
If you are not familiar with operating support packages, you will need to supplement this instruction manual with information on basic operations to set up and run the support.
Each logic analyzer has basic information that describes how to perform tasks common to support packages on that platform. This information can be in the form of online help, an installation manual, or a user manual. For complete information on packet types and field descriptions, refer to the IEEE 1394_1995 Standard and the IEEE 1394a supplement.
This manual provides detailed information on the following topics:
H Connecting the logic analyzer to the system under test H Setting up the logic analyzer to acquire data from the system under test H Acquiring and viewing data H Using the probe adapter

Manual Conventions

This manual uses the following conventions: H The term “system under test (SUT)” refers to the 1394 Bus system from
which data will be acquired.
H The term “logic analyzer” refers to the Tektronix logic analyzer for which
this product was purchased.
H The term “module” refers to the Tektronix logic analyzer module for which
this product was purchased.

Logic Analyzer Documentation

A description of other documentation available for each type of Tektronix logic analyzer is located in the corresponding module user manual. The manual set provides the information necessary to install, operate, maintain, and service the logic analyzer and associated products.
TMS 871 1394 Bus Support Package Instruction Manual
ix
Preface

Contacting Tektronix

Product Support
Service Support
For other information
To write us
Website
For questions about using Tektronix measurement products, call toll free in North America: 1-800-TEK-WIDE (1-800-835-9433 ext. 2400) 6:00 a.m. – 5:00 p.m. Pacific time
Or contact us by e-mail: tm_app_supp@tek.com
For product support outside of North America, contact your local Tektronix distributor or sales office.
Tektronix offers extended warranty and calibration programs as options on many products. Contact your local Tektronix distributor or sales office.
For a listing of worldwide service centers, visit our web site. In North America:
1-800-TEK-WIDE (1-800-835-9433) An operator will direct your call.
Tektronix, Inc. P.O. Box 1000 Wilsonville, OR 97070-1000 USA
Tektronix.com
x
TMS 871 1394 Bus Support Package Instruction Manual

Getting Started

This chapter provides information on the following topics and tasks:
H A description of the TMS 871 1394 Bus support package H Logic analyzer software compatibility H Options and accessories H Support restrictions H How to connect to the system under test
Figure 1–1 shows components of the TMS 871 1394 Bus support package.
Figure 1–1: TMS 871 support package
TMS 871 1394 Bus Support Package Instruction Manual
1–1
Getting Started

Support Description

The TMS 871 1394 Bus support package displays data from the IEEE 1394 High Performance Serial Bus. The support runs on a compatible Tektronix logic analyzer equipped with a 68-channel or wider module, and requires two P6434 probes.
A complete list of standard and optional accessories is provided at the end of the parts list in the Replaceable Mechanical Parts chapter.

Logic Analyzer Software Compatibility

The TMS 871 application software requires Version 3.0 and higher of TLA 700 System software running on the logic analyzer, and Version 3.0 and higher of TLA 700 LA module firmware on the modules you will be using.

Standard Accessories

Options

The probe adapter is shipped with the following standard accessories:
H TMS 871 Support SW Disk H TMS 871 Support Instruction Manual H 1394 cable H 5V power supply H North American power cord
The following options are available when ordering the TMS 871 Support:
H Option A1 Power Cord, Europe, 230 V H Option A2 Power Cord, United Kingdom, 230 V H Option A3 Power Cord, Australia, 230 V H Option A5 Power Cord, Switzerland, 230 V H Option 21 Add 2 P6434 Probes
1–2
TMS 871 1394 Bus Support Package Instruction Manual

Requirements and Restrictions

You should review the general requirements and restrictions of 1394 Bus support in the information on basic operations.
You should also review electrical, environmental, and mechanical specifications in the Specifications chapter in this manual as they pertain to your system under test, as well as the following descriptions of other support requirements and restrictions.
Getting Started

System Clock Rate

Merged Module Pair

The TMS 871 support package can acquire data from the 1394 bus operating at speeds of 100, 200, or 400 Mb/s.
If you have a pair of modules that are merged in the logic analyzer, you can un-merge them (and use either one). If you want the modules to remain merged, then the probe adapter must connect to the master module.

Connecting to a System Under Test

To connect the logic analyzer to the probe adapter, follow these steps:
CAUTION. Static discharge can damage the probe adapter, the probes, or the module. To prevent static damage, handle all of these products only in a static-free environment.
1. Plug the power supply into an appropriate power source.
2. Connect the DC plug to the probe adapter to provide power to the probe
adapter.
3. Connect the P6434 probes to the 1394 probe adapter. Align the probe tip with
the mating connector and gently connect as shown in Figure 1–2.