Tektronix TMS809 Instruction Manual

Instruction Manual
TMS809 AGP 3.0 Bus Support
071-1084-00
Warning
The servicing instructions are for use by qualified personnel only. To avoid personal injury, do not perform any servicing unless you are qualified to do so. Refer to all safety summaries prior to performing service.
www.tektronix.com
Copyright © Tektronix, Inc. All rights reserved. Licensed software products are owned by Tektronix or its suppliers and are protected by United States copyright laws and international treaty provisions.
Use, duplication, or disclosure by the Government is subject to restrictions as set forth in subparagraph (c)(1)(i i) of the Rights in Technical Data and Computer Software clause at DFARS 252.227-7013, or subparagraphs (c)(1) and (2) of the Commercial Computer Software -- Restricted Rights clause at FAR 52.227-19, as applicable.
Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supercedes that in all previously published material. Specifications and price change privileges reserved.
Tektronix, Inc., P.O. Box 500, Beaverton, OR 97077
TEKTRONIX and TEK are registered tradem arks of Tektronix, Inc.

SOFTWARE WARRANTY

Tektronix warrants that the media on which thi s software product is furnished and the encoding of the programs on the media will be free from defects in materials and workmanship for a period of three (3) months from the dat e of shipment. If a medium or encoding proves defective during the warranty period, Tektronix will provide a replacement in exchange for the defective medium. Except as to the media on which this software product is furnished, this software product is provided “as is” without warranty of any kind, either express or implied. Tektronix does not warrant that the functions contained in this software product will meet Customer’s requirements or that the operation of the programs will be uninte rrupted or error-free.
In order to obtain service under this warranty, Customer must notify Tektronix of the defect before the expiration of the warranty period. If Tektronix is unable to provide a replacement that is free from defects in materials and workmanship within a reasonable time thereafter, Customer may terminate the license for this software product and return this software product and any associated materials for credit or refund.
THIS W ARRANTY IS GIVEN BY TEKTRONIX IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED. TEKTRONIX AND ITS VENDORS DISCLAIM ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. TEKTRONIX’ RESPONSIBILITY TO REPLACE DEFECTIVE MEDIA OR REFUND CUSTOMER’S PAYMENT IS THE SOLE AND EXCLUSIVE REMEDY PROVIDED TO THE CUSTOMER FOR BREACH OF THIS WARRANTY. TEKTRONIX AND ITS VENDORS WILL NOT BE LIABLE FOR ANY INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES IRRESPECTIVE OF WHETHER TEKTRONIX OR THE VENDOR HAS ADVANCE NOTICE OF THE POSSIBILITY OF SUCH DAMAGES.

HARDWARE WARRANTY

Tektronix warrants that the products that it m anufactures and sells will be free from defects in materials and workmanship for a period of one (1) year from the date of shipment. If a product proves defect ive during this warranty period, Tektronix, at its option, ei ther will repa ir the defec tive product without charge for parts and labor, or will provide a replacement in exchange for the defective product.
In order to obtain service under this warranty, Customer must notify Tektronix of the defect before the expiration of the warranty period and make suitable arrangements for the performance of service. Customer shall be responsible for packaging and shipping the defective product to the service center designated by Tektronix, with shipping charges prepaid. Tektronix shall pay for the return of the product to Customer if the shipment i s to a location within the country in which the Tektronix service center is located. Customer shall be responsible for paying all shipping charges, duties, taxes, and any other charges for products returned to any other locations.
This warranty shall not apply to any defe ct, fail ure or damage caused by improper use or improper or inadequate maintenance and care. Tektronix shall not be obligated to furnish service under this warranty a) to repair damage resulting from attempts by personnel other than Tektronix representatives to install, repair or service the product; b) to repair damage resulting from improper use or connection to incompatible equipment; c) to repair any damage or malfunction caused by the use of non-Tektronix supplies; or d) to service a product that has been modified or integrated with other products when the effect of such modification or integration increases the time or difficulty of servicing the product.
THIS W ARRANTY IS GIVEN BY TEKTRONIX IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED. TEKTRONIX AND ITS VENDORS DISCLAIM ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. TEKTRONIX RESPONSIBILITY TO REPAIR OR REPLACE DEFECTIVE PRODUCTS IS THE SOLE AND EXCLUSIVE REMEDY PROVIDED TO THE CUSTOMER FOR BREACH OF THIS WARRANTY. TEKTRONIX AND ITS VENDORS WILL NOT BE LIABLE FOR ANY INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES IRRESPECTIVE OF WHETHER TEKTRONIX OR THE VENDOR HAS ADVANCE NOTICE OF THE POSSIBILITY OF SUCH DAMAGES.

Table of Contents

Getting Started
Operating Basics
General Safety Summary vii..........................................
Service Safety Summary ix..........................................
Manual Conventions xi..............................................
Contacting Tektronix xii.............................................
Probe Adapter Description 1--1.........................................
Logic Analyzer Software Compatibility 1--1..............................
Logic Analyzer Configuration 1--2......................................
Probe Adapter Review 1--4............................................
Components and Standard Accessories 1--5...............................
Configuring the Probe Adapter 1--6....................................
Connecting the Logic Analyzer to a Target System 1--7.....................
Verifying Probe Operation 1--23........................................
Replacing the Pogo Pin Assembly (Backside Board) 1--25....................
Storage 1--26........................................................
Care and Maintenance 1--27............................................
Shipping the Probe Adapter 1--28.......................................
Reference
Specifications
Maintenance
Installing the Software 2-- 1............................................
Support Package Setups 2--2...........................................
Channel Group Definitions 2--2.........................................
Symbol Tables 2--2..................................................
Acquiring and Viewing Disassembled Data 2--3............................
Viewing an Example of Disassembled Data 2--7...........................
Symbol Tables 3-- 1............................................
Channel Group Definition Tables 3-- 5............................
Channel Assignment Tables 3-- 25.................................
Signals Required for Clocking and Disassembly 3--43........................
Load Models 4--4....................................................
Fuses 5--1..........................................................
Fan Removal and Installation Procedure 5--3......................
Removing and Instaling a Fan 5--3......................................
TMS809 AGP 3.0 Bus Support
i
Table of Contents
Replaceable Parts List
Index
Parts Ordering Information 6--1.........................................
Using the Replaceable Parts List 6--2....................................
TMS809 AGP 3.0 Bus Support
ii

List of Figures

Table of Contents
Figure 1--1: Configuration of the slave 2, master, and
slave modules 1--3..........................................
Figure 1--2: Switch for AGP8X or AGP4X mode 1--6................
Figure 1-- 3: Connect the Interposer probe adapter to the
AGP 3.0 bus connector 1-- 9..................................
Figure 1--4: Preprocessor unit and access panel 1--10.................
Figure 1--5: Attach the power cables 1--10..........................
Figure 1--6: Attaching the mounting plate to the target system 1--14....
Figure 1--7: Attaching the Front End board assembly 1--16............
Figure 1--8: Assembled Backside probe head 1--17...................
Figure 1--9: Attach the power cables 1--18..........................
Figure 1--10: Preprocessor unit and access panel 1--18................
Figure 1--11: Configuration of the slave 2, master, and slave modules 1--20
Figure 1--12: Operating the P6434 probe latches 1--21................
Figure 1--13: Probes with mictor adapters 1--22.....................
Figure 1--14: Preprocessor unit and access panel 1--24................
Figure 1--15: Replacing the Pogo pin assembly on the
Backside board 1--25........................................
TMS809 AGP 3.0 Bus Support
Figure 2--1: Select these definitions for AGP8X 2--4.................
Figure 3--1: Configuration for slave 2, master, and slave modules 3--25..
Figure 4--1: Strobe separation 4--2...............................
Figure 4-- 2: Interposer source sync load model 4-- 4.................
Figure 4--3: Backside source sync load model 4--4...................
Figure 4--4: Dimensions of the AGP 3.0 Interposer probe head 4--7....
Figure 4--5: Dimensions of the AGP 3.0 Backside probe head 4--8.....
Figure 4-- 6: Dimensions of the preprocessor unit 4--9................
Figure 5--1: Power switch and AC power cord locations 5--4..........
Figure 5--2: Remove the attaching screws 5--5......................
Figure 5--3: Remove the bottom cover 5--6.........................
Figure 5--4: Removing the fan pin connector 5--7...................
Figure 5-- 5: Back of the preprocessor unit 5-- 8.....................
Figure 5--6: Location of fan connector 5--9.........................
Figure 6--1: Interposer probe head exploded view 6--4...............
iii
Table of Contents
Figure 6--2: Backside probe head exploded view 6--6................
Figure 6-- 3: Preprocessor unit exploded view 6-- 9...................
TMS809 AGP 3.0 Bus Support
iv

List of Tables

Table of Contents
Table 2--1: Waveform displays 2--5..............................
Table 2--2: Default display radix 2-- 6............................
Table 3--1: AGP3_Command symbol table definitions 3--1...........
Table 3--2: AGP3_Status symbol table definitions 3--2...............
Table 3--3: AGP3_Control symbol table definitions 3--2.............
Table 3--4: AGP3_SBA_Cmd symbol table definitions 3--4...........
Table 3--5: 7_AD[31:0] channel group definitions 3--5...............
Table 3--6: 6_AD[31:0] channel group definitions 3--6...............
Table 3--7: 5_AD[31:0] channel group definitions 3--8...............
Table 3--8: 4_AD[31:0] channel group definitions 3--9...............
Table 3--9: 3_AD[31:0] channel group definitions 3--10...............
Table 3--10: 2_AD[31:0] channel group definitions 3--11..............
Table 3--11: 1_AD[31:0] channel group definitions 3--13..............
Table 3--12: 0/PCI_AD[31] channel group definitions 3--14...........
Table 3--13: 7_C#_BE[3:0]channel group definitions 3--15............
Table 3--14: 6_C#_BE[3:0]channel group definitions 3--15............
Table 3--15: 5_C#_BE[3:0] channel group definitions 3--16...........
Table 3--16: 4_C#_BE[3:0] channel group definitions 3--16...........
Table 3--17: 3_C#_BE[3:0]channel group definitions 3--16............
Table 3--18: 2_C#_BE[3:0] channel group definitions 3--17...........
Table 3--19: 1_C#_BE[3:0] channel group definitions 3--17...........
Table 3--20: 0/PCI_C#_BE[3:0] channel group definitions 3--17.......
Table 3--21: 7_SBA[7:0]# channel group definitions 3-- 18.............
Table 3--22: 6_SBA[7:0]# channel group definitions 3-- 18.............
Table 3--23: 5_SBA[7:0]# channel group definitions 3-- 19.............
Table 3--24: 4_SBA[7:0]# channel group definitions 3-- 19.............
Table 3--25: 3_SBA[7:0]# channel group definitions 3-- 20.............
Table 3--26: 2_SBA[7:0]# channel group definitions 3-- 20.............
Table 3--27: 1_SBA[7:0]# channel group definitions 3-- 21.............
Table 3--28: 0/PCI_SBA[7:0]# channel group definitions 3-- 21.........
Table 3--29: Command channel group definitions 3-- 22...............
Table 3--30: Control channel group definitions 3-- 22.................
Table 3--31: Status channel group definitions 3-- 23..................
Table 3--32: Misc channel group definitions 3--23...................
TMS809 AGP 3.0 Bus Support
v
Table of Contents
Table 3--33: Clock channel assignments 3-- 26.......................
Table 3--34: Qual channel assignments 3--26........................
Table 3--35: Master Address Module 32-channel assignments 3-- 27.....
Table 3--36: Master Control Module 32-channel assignments 3-- 28.....
Table 3--37: Master Data Module 32-channel assignments 3--29.......
Table 3--38: Master Extend Module 32-channel assignments 3-- 31.....
Table 3--39: Slave Address Module 32-channel assignments 3 --32......
Table 3--40: Slave Control Module 32-channel assignments 3--33......
Table 3--41: Slave Data Module 32-channel assignments 3--35.........
Table 3--42: Slave Extend Module 32-channel assignments 3-- 36.......
Table 3--43: Slave2 Address Module 32-channel assignments 3 --37.....
Table 3--44: Slave2 Control Module 32-channel assignments 3--39.....
Table 3--45: Slave2 Data Module 32-channel assignments 3--40........
Table 3--46: Slave2 Extend Module 32-channel assignments 3--41......
T able 4--1: Electrical specifications 4--1...........................
Table 4--2: Timing Support Channel--to--Channel Skew 4--2.........
Table 4--3: Electrical specifications for the AC input 4-- 3............
T able 4--4: Environmental specifications 4--3......................
Table 4--5: Certifications and compliances 4--5....................
TMS809 AGP 3.0 Bus Support
vi

General Safety Summary

Review the following safety precautions to avoid injury and prevent damage to this product or any products connected to it. To avoid potential hazards, use this product only as specified.
Only qualified personnel should perform service procedures.
While using this product, you may need to access other parts of the system. Read the General Safety Summary in other system manuals for warnings and cautions related to operating the system.
ToAvoidFireor
Personal Injury
Use Proper Power Cord. Use only the power cord specified for this product and certified for the country of use.
Ground the Product. This product is grounded through the grounding conductor of the power cord. To avoid electric shock, the grounding conductor must be connected to earth ground. Before making connections to the input or output terminals of the product, ensure that the product is properly grounded.
Observe All Terminal Ratings. To avoid fire or shock hazard, observe all ratings and markings on the product. Consult the product manual for further ratings information before making connections to the product.
Connect the ground lead of the probe to earth ground only.
Do not apply a potential to any terminal, including the common terminal, that exceeds the maximum rating of that terminal.
Do Not Operate Without Covers. Do not operate this product with covers or panels removed.
Use Proper Fuse. Use only the fuse type and rating specified for this product.
Avoid Exposed Circuitry. Do not touch exposed connections and components
when power is present.
Do Not Operate With Suspected Failures. If you suspect there is damage to this product, have it inspected by qualified service personnel.
TMS809 AGP 3.0 Bus Support
Do Not Operate Without a Fan. Before operating this product, direct a fan at the probe head for proper cooling.
Do Not Operate in Wet/Damp Conditions.
Do Not Operate in an Explosive Atmosphere.
Keep Product Surfaces Clean and Dry.
Provide Proper Ventilation. Refer to the manual’s installation instructions for
details on installing the product so it has proper ventilation.
vii
General Safety Summary
Symbols and Terms
Terms in this Manual. These terms may appear in this manual:
WARNING. Warning statements identify conditions or practices that could result in injury or loss of life.
CAUTION. Caution statements identify conditions or practices that could result in damage to this product or other property.
Terms on the Product. These terms may appear on the product:
DANGER indicates an injury hazard immediately accessible as you read the marking.
WARNING indicates an injury hazard not immediately accessible as you read the marking.
CAUTION indicates a hazard to property including the product.
CAUTION
Refer to Manual
WARNING
High Voltage
Protective Ground
(Earth) Terminal
Mains Disconnected
OFF (Power)
Mains Connected
ON (Power)
viii
TMS809 AGP 3.0 Bus Support

Service Safety Summary

Only qualified personnel should perform service procedures. Read this Service Safety Summary and the General Safety Summary before performing any service
procedures.
Do Not Service Alone. Do not perform internal service or adjustments of this product unless another person capable of rendering first aid and resuscitation is present.
Disconnect Power. To avoid electric shock, switch off the instrument power, then disconnect the power cord from the mains power.
Use Care When Servicing With Power On. Dangerous voltages or currents may exist in this product. Disconnect power, remove battery (if applicable), and disconnect test leads before removing protective panels, soldering, or replacing components.
To avoid electric shock, do not touch exposed connections.
TMS809 AGP 3.0 Bus Support
ix
Service Safety Summary
TMS809 AGP 3.0 Bus Support
x

Preface

Manual Conventions

This instruction manual contains specific information about the TMS809 AGP 3.0 Bus support package and is part of a set of information on how to operate this product on compatible Tektronix logic analyzers.
If you are familiar with operating bus support packages on the logic analyzer, you only need this instruction manual to set up and run the TMS809 support package.
If you are not familiar with operating bus support packages, you need to supplement this instruction manual with information on basic operations of the logic analyzer to set up and run the TMS809 support package. See Manual Conventions below for more information.
This manual uses the following conventions:
H The term “disassemblerrefers to the software that decodes bus cycles into
instruction mnemonics and cycle types.
H The phrase information on basic operationsrefers to your logic analyzer
online help or logic analyzer user manual covering the basic operations of a bus support.
H The phrase probe adapterrefers to the TMS809 support package software
and hardware.
H The phrase Front End boardrefers to the circuit board that is used with
both probe heads.
TMS809 AGP 3.0 Bus Support
xi
Preface

Contacting Tektronix

Phone 1-800-833-9200*
Address Tektronix, Inc.
14200 SW Karl Braun Drive P.O. Box 500 Beaverton, OR 97077 USA
Web site www.tektronix.com
Sales support 1-800-833-9200, select option 1*
Service support 1-800-833-9200, select option 2*
Technical support Email: techsupport@tektronix.com
1-800-833-9200, select option 3*
6:00 a.m. -- 5:00 p.m. Pacific time
* This phone number is toll free in North America. After office hours, pl ease leave a
voice mail message. Outside North America, contact a Tektronix sal es office or distributor; see the Tektronix web site for a list of offices.
xii
TMS809 AGP 3.0 Bus Support
Getting Started

Getting Started

This section contains a description of the probe adapter, and how to connect the logic analyzer to the target system.

Probe Adapter Description

The probe adapter allows the logic analyzer to acquire data from an Accelerated Graphics Port (AGP) bus (version 3.0) within the operating environment in the target system.
The probe adapter connects to the target system using the AGP 3.0 card connector. Signals from the bus flow from the probe adapter to the P6434 probes and through the probe cables to the logic analyzer.
The probe adapter package provides two probe heads:
H Interposer probe head (recommended for ease of use)
H Backside probe head (to use for lower target-system loading, if needed)
NOTE. When debugging an AGP Pro 1.5 V compatible graphic card, we recommend that you use the backside probe adapter.
The probe adapter support package installs software that displays timing and state information from systems based on the AGP 3.0 bus. The software supports two AGP 3.0 modes of operation, AGP8X and AGP4X, along with the PCI Local Bus Specification (PCI) operations.
To use this probe adapter package efficiently, you may also refer to Draft AGP
V3.0 Interface Specification, Revision 0.95R, original date: May 2001 document
(Intel web site).

Logic Analyzer Software Compatibility

The label on the floppy disk states which version of logic analyzer software the probe adapter package is compatible with.
TMS809 AGP 3.0 Bus Support
1- 1
Getting Started

Logic Analyzer Configuration

To use the probe adapter you need a logic analyzer equipped with the minimum module configuration of three 136-channel, 100 MHz modules. For timing you need one 102 channel, 100 MHz module.
You can take state and asynchronous timing acquisitions simultaneously if four modules and 15 probes are available.
The probe adapter requires a minimum of twelve Mass Termination Probes.
You can connect probes as desired based on the following configurations:
H 12 mictor connectors for disassembly
H 3 mictor connectors for timing only
Labeling Probes
P6860 Probes
The probe adapter relies on the default channel mapping and labeling scheme for the probes. Apply labels using the instructions described in the following manuals. These manuals can be accessed from the Tektronix.com web site or these topics can be located in the logic analyzer online help:
H P6434 Mass Termination Probe Instructions
H P6860 High Density Logic Analyzer Probe Label Instructions
You can use the TLA7AXX 120 MHz logic analyzer module and the P6860 probes with the Compression-on-PCB to P6860 Mictor adapter to connect to the AGP 3.0 probe adapter package.
Refer to the P6810, P6860, and P6880 Logic Analyzer Probes Instruction manual, 071-1059-XX, for more information. This manual can be accessed from the Tektronix.com web site or these topics can be located in the logic analyzer online help.
NOTE. When using the TLA7Axx modules with the TMS809 probe adapter, the analog outputs display the outputs of the digital buffers of the TMS809 and do not directly reflect the analog attributes of the AGP bus.
1- 2
TMS809 AGP 3.0 Bus Support
Getting Started
Module Configuration
You must configure and merge the modules as shown in Figure 1--1. The memory depth is automatically chosen based on the shallowest memory depth of the merged modules.
The term “master module” refers to the middle module of a 3-wide merge. The term “slave module” refers to the module in the higher numbered slot than the master module. The term slave 2module refers to the module in the lower numbered slot than the master module.
Slave 2 Master Slave
Acquisition Setup
TMS809 AGP 3.0 Bus Support
Figure 1- 1: Configuration of the slave 2, master, and slave modules
The probe adapter software affects the logic analyzer setup menus (and subme­nus) by modifying existing fields and adding bus-specific fields.
The probe adapter software adds the following selections to the Load Support dialog box, located under the File pulldown menu:
H AGP3_8X Disassembly mode
H AGP3_4X Disassembly mode
H AGP3_T Timing mode
After you load the software, the Custom Clocking mode selection in the module Setupmenuisalsoenabled(seeCustom Clocking Mode on page 2--3).
To use the AGP4X mode, refer to Configuring the Probe Adapteronpage1--6. The AGP 3.0 probe adapter is shipped configured for the AGP8X mode.
1- 3
Getting Started

Probe Adapter Review

Requirements and
Restrictions
Functionality Not
Supported
Review the electrical specifications in the Specifications section in this manual as they pertain to the target system, as well as the following descriptions of other AGP 3.0 probe adapter package requirements and restrictions.
Hardware Reset. If a hardware reset occurs in the AGP 3.0 system during an acquisition, the application may acquire invalid samples until voltage levels stabilize.
System Clock Rate. The probe adapter can acquire data from the bus operating at speeds of up to 66 MHz. The AGP 3.0 probe adapter has been tested to a maximum Clock Rate of 66.625 MHz.
Review the functionalities that are not supported by the probe adapter package in the following descriptions:
Acquisition Channels. Extra acquisition channels are not available, since this probe adapter uses P6434 mictor connectors.
Sticky Address Bits. Sticky address bits are not tracked, stored, or displayed in TMS809 software package.
1- 4
AGP 2.0 Bus. Although the probe adapter supports the AGP4X mode of operation
on an AGP3.0 bus, the probe adapter does not support AGP4X on the AGP2.0 bus.
Dynamic Switching. Dynamic switching modes between AGP8X and AGP4X modes are not supported. To set up the AGP4X mode, refer to Configuring the Probe Adapter on page 1--6. The probe adapter is shipped from the factory in the AGP8X mode configuration.
Nonintrusive Acquisition. The probe adapter will not present signals back to the target system.
TMS809 AGP 3.0 Bus Support

Components and Standard Accessories

The probe adapter is shipped with the following components and standard accessories:
H Probe adapter: Preprocessor unit, cables, Interposer probe head (attached),
and Backside probe head
H Hardware
H Positioning block and mounting plate with adhesive strips (one-time use
and curing advised seepage1--12)
H Screws and washers (2 ea)
H Extension nuts (4)
H AC power cord
H Document and software package: Includes the probe adapter manual, license
agreement envelope with software disc, registration card, and statement of compliance envelope
Getting Started
For optional accessories, see the Replaceable Parts List on page 6--8.
TMS809 AGP 3.0 Bus Support
1- 5
Getting Started

Configuring the Probe Adapter

The probe adapter is configured for the AGP8X mode from the factory. To use either the AGP8X or the AGP4X modes, follow these steps:
1. Change the mode switch on the front of the preprocessor unit to AGP4X
mode or AGP8X mode (see Figure 1--2).
2. Power the probe adapter off and on.
3. Reset the target system while in the chosen mode.
NOTE. The AGP4X mode is available only for AGP3.0 target systems.
8X mode
i
4X mode
The “i” indicates a reminder to reset the target system.
Figure 1- 2: Switch for AGP8X or AGP4X mode
1- 6
TMS809 AGP 3.0 Bus Support

Connecting the Logic Analyzer to a Target System

We recommend that you use the Interposer probe head to connect the logic analyzer to the target system. If the target system functions improperly using the Interposer board, use the Backside probe head. If you use the B ackside probe head, you need to remove the target system from the case that houses it.
NOTE. For storage and shipping, retain the cardboard cartons and packing material that is shipped with the probe adapter.
WARNING. To prevent harm to yourself or damage to the preprocessor unit, do not open the preprocessor unit. There are no operator serviceable parts inside the preprocessor unit. Refer servicing of internal parts in the preprocessor unit to Tektronix authorized personnel only. External parts may be replaced by qualified service personnel.
Getting Started
Tools Required. Following is a list of required tools:
H Nut driver (1/4 in) to remove the extension nuts from the Backside board
assembly
H Phillips screwdriver (P2) to remove a probe head and to secure the Backside
probe head
H Flat blade screwdriver to install the probe heads
Optional Tools. A torque wrench helps to ensure reliable connections by meeting the nominal torque values listed in these instructions.
See the following pages for these procedures:
H Interposer probe head installation (see page 1--8)
H Probe-head removal (see page 1--11)
H Backside probe head installation (see page 1--12)
WARNING. To prevent burns, forced air cooling is required across the probe adapter to maintain a temperature below 105 temperature for the components and the probe adapter.
°C (220 °F). You must verify this
TMS809 AGP 3.0 Bus Support
1- 7
Getting Started
CAUTION. To prevent static damage to the power pod, probe adapter, probes, and module, handle components only in a static-free environment.
Always wear a grounding wrist strap, heel strap, or similar device while handling the bus and probe adapter.
Connecting the Interposer
Probe Head
For the first-time connection of the Interposer probe head to the AGP 3.0 signals in the target system, follow these steps:
NOTE. If you are reconnecting the Interposer probe head, see Reconnecting the Interposer Probe Head on page 1--9.
1. Power off the target system. It is not necessary to power off the logic
analyzer.
2. Power off any probe adapters that may be attached to your target system. If
the Backside probe head is attached, follow the instructions for Removing a Probe Head on page 1--11.
3. To discharge any stored static electricity, touch the ground connector located
on the back of the logic analyzer.
4. Place the preprocessor unit on a horizontal, static free surface.
NOTE. When debugging an AGP Pro 1.5 V compatible graphic card, we recommend that you use the backside probe adapter.
5. Remove the AGP 3.0 bus card from the target system.
1- 8
6. Connect the Interposer probe head to the target system as shown in
Figure 1--3.
7. Connect the AGP 3.0 bus card to the Interposer probe head.
CAUTION. To prevent damage to the probe adapter or target system when pow er is applied, connect the target system to the probe adapter properly.
TMS809 AGP 3.0 Bus Support
AGP 3.0 bus card
AGP 3.0 Interposer probe head (includes Front End board and Backside board)
Getting Started
AGP 3.0 bus connector
Reconnecting the
Interposer Probe Head
Target system
Figure 1- 3: Connect the Interposer probe adapter to the AGP 3.0 bus connector
WARNING. To prevent burns, forced air cooling is required across the probe adapter to maintain a temperature below 105
°C (220 °F). You must verify this
temperature for the components and the probe adapter.
8. Apply forced air cooling across the probe head.
Before you begin to reconnect the Interposer probe head, check that no probe adapters are attached to the preprocessor unit and that the access panel on top of the preprocessor unit has been removed.
NOTE. When debugging an AGP Pro 1.5 V compatible graphic card, we recommend that you use the backside probe adapter.
1. Power off the preprocessor unit.
TMS809 AGP 3.0 Bus Support
2. Power off the target system. You do not need to power off the logic analyzer.
3. Discharge the stored static electricity by touching the ground connector
located on the back of the logic analyzer.
1- 9
Getting Started
4. Connect the three small boards (attached to the probe-head cables), matching
A to A, B to B, and C to C, to the Logic board. Access to the small board connections is through the access panel on top of the preprocessor unit (see Figure 1--4).
S2_E_DIS
S2_C_DIS
S2_A_DIS
S2_D_DIS
M_C_DIS
M_A_DIS
S_C_DIS
S2_D_DIS
S2_E_DIS
S2_A_DIS
M_E_DIS
M_D_DIS
M_A_TMG
M_C_TMG
Access panel
M_D_TMG
Screws (6)
Figure 1- 4: Preprocessor unit and access panel
5. Using a Phillips screwdriver, install the six screws into the three small
boards (torque to 4 in-in/lb).
6. Using a Phillips screwdriver, attach the three power cables and the three
screws (torque to 6 in/lb) to the Front End board (see Figure 1--5).
CAUTION. To prevent damage to the probe adapter, check that the power cables are reattached to the Front End board correctly.
Front End board
1- 10
Black to GND
Yellow to --5 V
Redto+5V
Figure 1- 5: Attach the power cables
7. Hand start the screws that attach the access panel to the top of the preproces-
sor unit.
TMS809 AGP 3.0 Bus Support
Getting Started
8. Using a Phillips screwdriver, tighten the screws (torque to 4 in/lb) in the
access panel (see Figure 1--4).
9. Connect the Interposer probe head to the target system (go to step 6 on
page 1--8 and complete the steps).
Removing a Probe Head
If you need to remove a probe head, follow these steps:
CAUTION. To prevent static damage, handle these components only in a static-free environment. Static discharge can damage the probe adapter, the probes, and the logic analyzer module.
Always wear a grounding wrist strap, heel strap, or similar device while handling the probe adapter.
1. Power off the probe adapter and unplug the AC power cord on the preproces-
sor unit from the wall. The probe adapter power switch is located on the back of the preprocessor unit. It is not necessary to power off the logic analyzer.
2. Using a Phillips screwdriver, remove the screws from the access panel
located on top of the preprocessor unit (see Figure 1--4). Set the access panel aside.
3. Using a Phillips screwdriver, remove the screws from the three small boards
(attached to the probe-head cables). Access to the small boards is through the access panel on top of the preprocessor unit.
4. Disconnect the small boards from the Logic board.
TMS809 AGP 3.0 Bus Support
NOTE. Do not remove the power cables from the preprocessor unit.
5. Remove the three screws and the three power cables from the Front End
board. Set the screws aside for use later.
Interposer probe head only — Disconnect the Interposer probe head from the target system. To properly store the Interposer probe head for use later, see Storage on page 1--26. To store the AGP 3.0 bus card, refer to the AGP 3.0 bus card information from the manufacturer. To reinstall the Interposer probe head, go to Reconnecting the Interposer Probe Head on page 1--9.
Backside probe head only — To complete the removal procedure for the Backside probe head, follow these steps:
6. Using a Phillips screwdriver, remove the two screws from the center two
holes on the Front End board assembly (see Figure 1--8 on page 1--17).
1- 11
Getting Started
7. Remove the Front End board assembly from the Backside board assembly.
8. Using a nut driver, carefully remove the four extension nuts from the
Backside board assembly (see Figure 1--7 on page 1--16).
9. Remove the Backside board from the mounting plate on the target system.
NOTE. We recommend that you do not remove the mounting plate after it is attached to the target system.
To properly store the Backside probe head for use later, see Storage on page 1--26.
Connecting the Backside
Probe Head
To connect the Backside probe head to the signals on the target system, follow these steps:
1. Power off the target system. It is not necessary to power off the logic
analyzer.
CAUTION. To prevent static damage, handle these components only in a static-free environment. Static discharge can damage the probe adapter, the probes, and the logic analyzer module.
Always wear a grounding wrist strap, heel strap, or similar device while handling the bus.
2. To discharge the stored static electricity, touch the ground connector located
on the back of the logic analyzer.
3. Disconnect any attached probe adapters. See Removing a Probe Head on
page 1--11.
NOTE. Use an antistatic cushion to protect the components on the underside of the target system, because you will be applying pressure to the AGP 3.0 board.
1- 12
4. Place the target system on a horizontal, static-free surface (the back of the
AGP 3.0 connector must be visible).
TMS809 AGP 3.0 Bus Support
Loading...
+ 116 hidden pages