Tektronix TLA7SA08 Declassification

xx
TLA7SA08 and TLA7SA16
ZZZ
Serial Analyzer Modules
Declassication and Security Instructions
www.tektronix.com
*P077040100*
077-0401-00
Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supersedes that in all previously published material. Specications and price change privileges reserved.
TEKTRONIX and TEK are registered trademarks of Tektronix, Inc.
Contacting Tektronix
Tektronix, 14200 SW Karl Braun Drive P.O . Bo x 5 00 Beaverton, OR 97077 USA
For product information, sales, service, and technical support:
In North America, call 1-800-833-9200. Worldwide, visit www.tektronix.com to nd contacts in your area.
Inc.
Table of Contents
Preface ................. ................................ ................................ ............................. iii
Clear and Sanitize Procedures........................... .................................... ...................... 1
Memory Devices......................... ................................ .................................... .. 1
Data Export Devices. .... .................................... ................................ .................. 2
Troubleshooting.. . ........................ .................................... ................................ ...... 3
How to Clear a Non-Functional Instrument .. .................................... .......................... 3
TLA7SA08 and TLA7SA16 Declassication and Security Instructions i
Table of Contents
ii TLA7SA08 and TLA7SA16 Declassication and Security Instructions
Preface
This document helps customers with data security concerns to sanitize or remove memory devices from TLA7SA08 and TLA7SA16 Serial Analyzer Modules.
These products have data storage (memory) devices and data output devices (USB ports). These instructions tell how to do the following:
Clear or sanitize the memory devices
Clear or sanitize an instrument that is not functioning
Products
Related Documents
Terms
The following Tektronix products are covered by this document:
TLA7SA08
TLA7SA16
The TLA7SA08 and TLA7SA16 Serial Analyzer Modules do not have a separate service manual. Refer to the TLA7S08 and TLA7S16 Serial Analyzer Modules Service Manual (Tektronix part number, 071-2188-XX) for the basic remove and replace instructions. This manual is available on the Tektronix Web site at www.tektronix.com/manuals. For other service needs, contact your local Tektronix representative.
The following terms may be used in this document:
Clear. This removes data on media/memory before reusing it in a secured area. All reusable memory is cleared to deny access to previously stored information by standard means of access.
Erase. This is equivalent to clear.
Media storage/data export. Various devices that are used to store or export data
from the instrument, such as a USB port.
Nonvolatile memory. Data is retained when the instrument is powered off.
Remove. This is a physical means to clear the data by removing the memory
device from the instrument. Instructions are available in the product service manual.
Sanitize. This eradicates the data from media/memory so that the data cannot be recovered by other means or technology. This is typically used when the device will be moved (temporarily or permanently) from a secured area to a non-secured area.
Scrub. This is equivalent to sanitize.
User-modiable. The memory device can be written to by the user during normal
instrument operation, using the instrument’s user interface or remote control.
TLA7SA08 and TLA7SA16 Declassication and Security Instructions iii
Preface
Volatile memory. Data is lost when the instrument i s powered off.
iv TLA7SA08 and TLA7SA16 Declassication and Security Instructions
Clear and Sanitize Procedures
Memory Devices
The following tables list the volatile and nonvolatile memory devices in the standard instrument and listed options.
YouonlyneedtoperformtheNonvolatile Memory Security Procedure to clear the instrument.
Table 1: Volatile memory devices
Type and minimum size Function
DDR,
8.2 G x 8 (TLA7SA16)
4.1 G x 8 (TLA7SA08)
DRAM, 4MX8
Acquisition memory for storing acquired data
Firmware execution code
Table 2: Nonvolatile memory devices
Type and minimum size Function
FLASH, 2MX16
NVRAM, 128 K X 8
Flash, 32 M X 16
Stores instrument rmware and FPGA data
Stores instrument serial number and calibration constants
Stores FPGA bit les
User modiable Input method Location
No
No Written by the
Written by FPGA
processor system
Acquisition board Remove power
LPU board Remove power
User modiable Input method Location
No Programmed at
thefactory,nouser data
No. Written by
processor
No Programmed at
thefactory,nouser data
LPU board Remove LPU
LPU board Remove LPU
Acquisition board
Process to clear
source from the instrument for at least 20 seconds.
source from the instrument for at least 20 seconds.
Process to clear
Process to sanitize
Process to sanitize
board and either securely store it or destroy it.
board and either securely store it or destroy it.
Remove Acquisition board and either securely store it or destroy it.
Nonvolatile Memory
Security Procedure
User data is not stored in nonvolatile memory. To secure nonvolatile memory, proceed as follows:
1. Remove the LPU board and Acquisition board from the module. Refer to the Tektronix Logic Analyzer Solutions for PCI Express 3.0 Instruction Manual (Tektronix part number, 077-0400-XX) on the Tektronix Web site at www.tektronix.com/manuals.
2. Since there is no way for you to erase nonvolatile memory, either store these
rcuit boards in a secure area or destroy them.
ci
TLA7SA08 and TLA7SA16 Declassication and Security Instructions 1
Clear and Sanitize Procedures
Data Export Devices
Table3: Dataexportdevices
The following table lists the data export devices in the standard instrument and listed option
s.
User
Type Function
Reference clock
VXI backplane Interfaces with TLA mainframe No Instrument
Reference Clock and VXI
Provides a copy of the internal reference clock
Backplane
To locate and remove the Reference Clock cable and module from the TLA mainframe, refer to the Tektronix Logic Analyzer Solutions for PCI Express 3.0
modiable
No User directed
Input method Location Process to disable
function and application software
Instruction Manual (Tektronix part number, 077-0400-XXX) on the Tektronix Web site at www.tektronix.com/manuals.
Front panel of module
Backplane connectors
Unplug the Reference Clock cable from the output port on the front panel (See below).
Power off the TLA mainframe power and removethemodule(Seebelow).
2 TLA7SA08 and TLA7SA16 Declassication and Security Instructions
Troubleshooting
How to Clear a Non-Functional Instrument
If your instrument is not functioning and you need to clear it, remove the power source from the instrument for at least 20 seconds.
TLA7SA08 and TLA7SA16 Declassication and Security Instructions 3
Troubleshooting
4 TLA7SA08 and TLA7SA16 Declassication and Security Instructions
Loading...