Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication
supersedes that in all previously published material. Specifications and price change privileges reserved.
TEKTRONIX and TEK are registered trademarks of Tektronix, Inc.
Contacting Tektronix
Tektronix,
14200 SW Karl Braun Drive
P.O . Bo x 5 00
Beaverton, OR 97077
USA
For product information, sales, service, and technical support:
In North America, call 1-800-833-9200.
Worldwide, visit www.tektronix.com to find contacts in your area.
How to Clear a Non-Functional Instrument .. .................................... ..........................3
TLA7SA08 and TLA7SA16 Declassification and Security Instructionsi
Table of Contents
iiTLA7SA08 and TLA7SA16 Declassification and Security Instructions
Preface
This document helps customers with data security concerns to sanitize or remove
memory devices from TLA7SA08 and TLA7SA16 Serial Analyzer Modules.
These products have data storage (memory) devices and data output devices (USB
ports). These instructions tell how to do the following:
Clear or sanitize the memory devices
Clear or sanitize an instrument that is not functioning
Products
Related Documents
Terms
The following Tektronix products are covered by this document:
TLA7SA08
TLA7SA16
The TLA7SA08 and TLA7SA16 Serial Analyzer Modules do not have a separate
service manual. Refer to the TLA7S08 and TLA7S16 Serial Analyzer ModulesService Manual (Tektronix part number, 071-2188-XX) for the basic remove
and replace instructions. This manual is available on the Tektronix Web site
at www.tektronix.com/manuals. For other service needs, contact your local
Tektronix representative.
The following terms may be used in this document:
Clear. This removes data on media/memory before reusing it in a secured area.
All reusable memory is cleared to deny access to previously stored information
by standard means of access.
Erase. This is equivalent to clear.
Media storage/data export. Various devices that are used to store or export data
from the instrument, such as a USB port.
Nonvolatile memory. Data is retained when the instrument is powered off.
Remove. This is a physical means to clear the data by removing the memory
device from the instrument. Instructions are available in the product service
manual.
Sanitize. This eradicates the data from media/memory so that the data cannot be
recovered by other means or technology. This is typically used when the device
will be moved (temporarily or permanently) from a secured area to a non-secured
area.
Scrub. This is equivalent to sanitize.
User-modifiable. The memory device can be written to by the user during normal
instrument operation, using the instrument’s user interface or remote control.
TLA7SA08 and TLA7SA16 Declassification and Security Instructionsiii
Preface
Volatile memory. Data is lost when the instrument i s powered off.
ivTLA7SA08 and TLA7SA16 Declassification and Security Instructions
Clear and Sanitize Procedures
Memory Devices
The following tables list the volatile and nonvolatile memory devices in the
standard instrument and listed options.
YouonlyneedtoperformtheNonvolatile Memory Security Procedure to clear
the instrument.
Table 1: Volatile memory devices
Type and minimum sizeFunction
DDR,
8.2 G x 8 (TLA7SA16)
4.1 G x 8 (TLA7SA08)
DRAM,
4MX8
Acquisition
memory
for storing
acquired data
Firmware
execution code
Table 2: Nonvolatile memory devices
Type and minimum
sizeFunction
FLASH,
2MX16
NVRAM,
128 K X 8
Flash,
32 M X 16
Stores
instrument
firmware and
FPGA data
Stores
instrument
serial number
and calibration
constants
Stores FPGA
bit files
User
modifiableInput methodLocation
No
NoWritten by the
Written by FPGA
processor system
Acquisition boardRemove power
LPU boardRemove power
User
modifiableInput methodLocation
NoProgrammed at
thefactory,nouser
data
No.Written by
processor
NoProgrammed at
thefactory,nouser
data
LPU boardRemove LPU
LPU boardRemove LPU
Acquisition
board
Process to
clear
source from the
instrument for at
least 20 seconds.
source from the
instrument for at
least 20 seconds.
Process to
clear
Process to
sanitize
Process to
sanitize
board and either
securely store it
or destroy it.
board and either
securely store it
or destroy it.
Remove
Acquisition
board and either
securely store it
or destroy it.
Nonvolatile Memory
Security Procedure
User data is not stored in nonvolatile memory. To secure nonvolatile memory,
proceed as follows:
1. Remove the LPU board and Acquisition board from the module. Refer to
the Tektronix Logic Analyzer Solutions for PCI Express 3.0 InstructionManual (Tektronix part number, 077-0400-XX) on the Tektronix Web site at
www.tektronix.com/manuals.
2. Since there is no way for you to erase nonvolatile memory, either store these
rcuit boards in a secure area or destroy them.
ci
TLA7SA08 and TLA7SA16 Declassification and Security Instructions1
Clear and Sanitize Procedures
Data Export Devices
Table3: Dataexportdevices
The following table lists the data export devices in the standard instrument and
listed option
s.
User
TypeFunction
Reference
clock
VXI backplaneInterfaces with TLA mainframeNoInstrument
Reference Clock and VXI
Provides a copy of the internal
reference clock
Backplane
To locate and remove the Reference Clock cable and module from the TLA
mainframe, refer to the Tektronix Logic Analyzer Solutions for PCI Express 3.0
modifiable
NoUser directed
Input
methodLocationProcess to disable
function and
application
software
Instruction Manual (Tektronix part number, 077-0400-XXX) on the Tektronix
Web site at www.tektronix.com/manuals.
Front panel of
module
Backplane
connectors
Unplug the Reference Clock cable from
the output port on the front panel (See
below).
Power off the TLA mainframe power and
removethemodule(Seebelow).
2TLA7SA08 and TLA7SA16 Declassification and Security Instructions
Troubleshooting
How to Clear a Non-Functional Instrument
If your instrument is not functioning and you need to clear it, remove the power
source from the instrument for at least 20 seconds.