Tektronix TLA7AA2, TLA7AB4, TLA7AA4, TLA7AB2, TLA7AC3 Instructions Manual

...
xx
TLA700/TLA7000 Series Tektronix Logic Analyzer
ZZZ
Declassication and Security
Instructions
www.tektronix.com
077-0037-01
Copyright © Tektronix. All rights reserved. Licensed software products are owned by Tektronix or its subsidiaries or suppliers, and are protected by national copyright laws and international treaty provisions.
Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supersedes that in all previously published material. Specications and price change privileges reserved.
TEKTRONIX and TEK are registered trademarks of Tektronix, Inc.
Contacting Tektronix
Tektronix, Inc. 14200 SW Karl Braun Drive P.O . B ox 5 00 Beaverton, O USA
For product information, sales, service, and technical support:
In North America, call 1-800-833-9200. Worl d wide , vi s it www.tektronix.com to nd contacts in your area.
R 97077
Table of Contents
Preface .............................................................................................................. iii
Clear and Sanitize Procedures. ... ... ... . ... ... ... . ... ... ... . . .. . ... ... ... . ... ... ... . ... ... ... . . .. . ... ... ... . ... ... 1
Memory Devices............................................................................................... 1
Data Export De
Troubleshooting..................................................................................................... 7
How to Sanitize or Clear a Nonfunctional Instrument ... . .. . ... ... ... . ... ... ... ... . .. . ... ... . .. . ... ... ... . 7
vices........................................................................................... 5
TLA700/TLA7000 Series Declassication and Security Instructions i
Table of Contents
ii TLA700/TLA7000 Series Declassication and Security Instructions
Preface
This document helps customers with data security concerns to sanitize or remove memory devices from the TLA700 and TLA7000 Series Logic Analyzer family modules.
These products have data storage (memory) devices and data output devices. These instru
Clear or sanitize the memory devices
Clear or sanitize an instrument that is not functioning
ctions tell how to do the following:
Products
The following Tektronix products are covered by this document:
TLA7AA1, TLA7AA2, TLA7AA3, TLA7AA4
TLA7AB2, T
TLA7AC2, TLA7AC3, TLA7AC4
TLA7NA1, TLA7NA2, TLA7NA3, TLA7NA4
TLA7N1, TLA7N2, TLA7N3, TLA7N4
TLA7P2, TLA7P4
TLA7NQ2, TLA7NQ4
TLA7XM
TLA7PG2
TLA7D1, TLA7D2
TLA7E1, TLA7E2
LA7AB4
TLA700/TLA7000 Series Declassication and Security Instructions iii
Preface
Related Documents
Terms
Refer to the fol www.tektronix.com/manuals or to the TLA Documentation CD that is available with your product:
TLA700 Series Mainframe Installation Manual
TLA7000 Seri
Tektronix Logic Analyzer Module (TLA7AAx, TLA7ABx & TLA7NAx) Service Manual
TLA7ACx Logic Analyzer Module Service Manual
Tektronix Logic Analyzer Module (TLA7Nx, TLA7Px, & TLA7Qx) Service Manual
TLA7PG2 Pattern Generator and Probes Service Manual
TLA721 Benchtop & TLA7XM Expansion Mainframe Service Manual
TLA7Dx & TLA7Ex Digitizing Oscilloscope Service Manual
The follow
Clear. This removes data on media/memory before reusing it in a secured area. All information by standard means of access.
lowing service documents available on the Tektronix Web site at
es Mainframe Installation Manual
ingtermsmaybeusedinthisdocument:
reusable memory is cleared to deny access to previously stored
Erase. T
Media storage/data export device. Any of several devices that can be used
to store
Nonvolatile memory. Data is retained when the instrument is powered off.
Remove. Thisisaphysicalmeanstoclearthedatabyremovingthememory
device from the instrument. Instructions are available in the product Service Manual
Sanitize. This eradicates the data from media/memory so that the data cannot be rec device will be moved (temporarily or permanently) from a secured area to a non-secured area.
Scrub. This is equivalent to sanitize.
User-
instrument operation, using the instrument interface or remote control.
Vola
his is equivalent to clear.
or export data from the instrument, such as a USB port.
.
overed by other means or technology. This is typically used when the
modiable. The user can write to the memory device during normal
tile memory. Data is lost when the instrument is powered off.
iv TLA700/TLA7000 Series Declassication and Security Instructions
Clear and Sanitize Procedures
Memory Device
s
Table 1: Volatile memory devices
Type an d minimum size Function
DRAM, 1MX8
DRAM, 1MX4
DRAM, 1MX16
DRAM, 64 K X 16
BICMOS
SDRAM 4MX16
SDRAM 1MX16
SDRAM 16 M X 1
ASIC 16 K
6
Firmware execution code
Firmware execution code
Firmware execution code
Firmware execution code
Firmware
on code
executi
tion
Acquisi memory for storing acquired data
Acquisition
for storing
memory acquired data
Acquisition memory for storing
ired data
acqu
essor
Proc execution memory
The following tables list the volatile and nonvolatile memory devices.
YouonlyneedtoperformtheNonvolatile Memory Security Procedure to clear the instrument. (Seepage4,Nonvolatile Memory Security Procedure.)
User modiable
No Written by th
No Written by the
No Written by
No Written by the
No Written by the
No Written
No Written by
No Written by
No
Data input method Location To clear To sanitize
processor system
processor system
processor system
processor system
process
controller ASICs
contro
controller ASICs
Written by ASICs
e
the
or system
by
ller ASICs
LPU board Remove power
LPU board, Enhanced Monitor board, TLA Clock & Backplane interface board
LPU board Remove pow
LPU board Remove power
LPU board Remove power
Acquisi
Acquisition board Remove power
Acquisition board Remove power
Acqu
7PG2
tion board
isition board
source from the instrument for at least 20 seconds.
Remove power source from the
t for at least
instrumen 20 seconds.
source from the instrument for at least 20 second
source from the instrume 20 seconds.
source f instrument for at least 20 seconds.
Remove p source from the instrument for at least 20 seco
source instrument for at least 20 seconds.
source from the inst 20 seconds.
Remo source from the instrument for at least 20 s
s.
nt for at least
rom the
ower
nds.
from the
rument for at least
ve power
econds.
Remove LPU board and either securely store it or destroy i
Remove LPU board and either
tore it
securely s or destroy it.
er
Remove LPU board and either securely store it
yit.
or destro
Remove LPU board and either
store it
securely or destroy it.
Remove LPU
deither
board an securely store it or destroy it.
Remove acquisition board and either
ly store it
secure or destroy it.
Remove
ition
acquis board and either securely store it
troy it.
or des
Remove acquisition
d and either
boar securely store it or destroy it.
ve
Remo acquisition board and either
urely store it
sec or destroy it.
t.
TLA700/TLA7000 Series Declassication and Security Instructions 1
Clear and Sanitize Procedures
Table 1: Volatile memory devices (cont.)
Type an d minimum size Function
SRAM, 128 K X 8
IC memory 256 K X 16 bit
Firmware execution code
Pattern generator data
User modiable
No Written by the
No
Table 2: Nonvolatile memory devices
Type and minimum size Function
FLASH, 2MX8
FLASH, 1MX16
FLASH, 2MX8
FLASH, 256 K X 8
FLASH, 256 K X 8
NVRAM, 32KX8
NVRAM, 512 K X 8
EPROM 64KX16
Stores instrument rmware
Stores instrument rmware
Stores instrument rmware
Stores instrument rmware
Stores instrument rmware
Stores instrument serial number and calibration constants
Stores instrument serial number and calibration constants
Stores instrument rmware
User modiable
No Programmed
No Programmed
No Programmed
No Programmed
No Programmed
No Written by
No Written by
No Programmed
Data input method Location To clear To sanitize
processor system
Written by AS
ICs
LPU board Remove power
TLA7PG2 PG bo
ard
source from the instrument f 20 seconds.
Remove power source from instrument for at least 20 seconds.
or at least
the
Remove LPU board and either securely sto or destroy it.
Remove PG board and either securely store it or destroy i
Data input method Location Process to clear To sanitize
at the factory, no user data
at the factory, no user data
at the factory, no user data
at the factory, no user data
at the factory, no user data
processor
processor
at the factory, no user data
LPU board
LPU board
Probe Flash Adapter board
TLA7Dx & TLA7Ex LPU board
TLA7XM Enhanced Monitor board
LPU board
TLA7Dx & TLA7Ex LPU board
TLA7XM Enhanced Monitor board
Load new rmware image. See manual.
Load new rmware image. See manual.
Load new rmware image. See manual.
Load new rmware image. See manual.
Load new rmware image. See manual.
N/A. No user data stored in this device.
N/A. No user data stored in this device.
N/A. No user data stored in this device.
Remove LPU board and either securely store it or destroy it.
Remove LPU board and either securely store it or destroy it.
Remove Probe Flash Adapter board and either securely store it or destroy it.
Remove LPU board and either securely store it or destroy it.
Remove Enhanced Monitor board and either securely store it or destroy it.
Remove LPU board and either securely store it or destroy it.
Remove LPU board and either securely store it or destroy it.
Remove Enhanced Monitor board and either securely store it or destroy it.
re it
t.
2 TLA700/TLA7000 Series Declassication and Security Instructions
Table 2: Nonvolatile memory devices (cont.)
Type and minimum size Function
EEPROM 1KX8
PROM Stores instrument
EPROM 2048 X 8
EPROM 512 K X 8, Flash
EPROM 256 K X 16
EPROM 1MX1bit
EEPROM 256 K X 8
Stores instrument
rmware
rmware
Stores instrument rmware
Stores instrument rmware
Stores instrument rmware
Stores instrument rmware
Stores instrument rmware
User modiable
No Programmed
No Programmed
No Programmed
No Programmed
No Programmed
No Programmed
No Programmed
Clear and Sanitize Procedures
Data input method Location Process to clear To sanitize
at the factory, no user data
at the factory, no user data
at the factory, no user data
at the factory, no user data
at the factory, no user data
at the factory, no user data
at the factory, no user data
TLA7XM Enhanced Monitor board
TLA7XM Enhanced Monitor board
TLA7PG2 Clock & Backplane interface board, TLA7PG2 PG board
TLA7PG2 Clock & Backplane interface board
TLA7PG2 Clock & Backplane interface board
TLA7PG2 PG board N/A. No user data stored
LPU board, Acquisition board
N/A. No user data stored in this device.
N/A. No user data stored in this device.
N/A. No user data stored in this device.
N/A. No user data stored in this device.
N/A. No user data stored in this device.
in this device.
N/A. No user data stored in this device.
Remove Enhanced Monitor board and either securely store it or destroy it.
Remove Enhanced Monitor board and either securely store it or destroy it.
Remove TLA7PG2 boards and either securely store them or destroy them.
Remove TLA7PG2 Clock & Backplane interface board and either securely store it or destroy it.
Remove TLA7PG2 Clock & Backplane interface board and either securely store it or destroy it.
Remove TLA7PG2 PG board and either securely store it or destroy it.
Remove circuit boards and either securely store them or destroy them.
TLA700/TLA7000 Series Declassication and Security Instructions 3
Clear and Sanitize Procedures
Nonvolatile Memory
Security Procedure
User data is not proceed as follows:
1. To remo v e the L service manual for the remove and replace procedures. (See page iv, Related Documents.)
2. To remove the Enhanced Monitor board from the TL7XM mainframe, refer to the TLA721 Benchtop & TLA7XM Expansion Mainframe Service Manual for the remove and replace procedures. ( See page iv, Related Documents.)
3. To remove the TLA7PG2 Clock & Backplane interface board or the TLA7PG2 PG board, refer to the TLA7PG2 Pattern Generator and Probes
Service Manual for the remove and replace procedures. (See page iv, Related Documents.)
4. Since there is no way for you to clear nonvolatile memory, either store these circuit boards in a secure area or destroy them.
stored in nonvolatile memory. To secure nonvolatile memory,
PU board from the module, refer to the appropriate module
4 TLA700/TLA7000 Series Declassication and Security Instructions
Data Export Devices
The following table lists the analog output data export devices in the TLA7Axx series logic analyzer modules.
Table 3: Data export devices (Analog Outputs)
Clear and Sanitize Procedures
Type Function
Analog outputs
Provides an analog copy of signals from the device under test
The followi
Table 4: Data export devices (Backplane)
Type Function
Backplane
Interfaces
with TLA mainframe
Backplane
To locate and remove the module from the TLA mainframe, refer to the TLA7000 Series Mainframe Installation Manual or to the TLA700 Series Mainframe Installation Manual on the Tektronix Web site at www.tektronix.com/manuals or
on the TLA Documentation CD.
User modiable
No From the
Input method Location P rocess to disable
device under test
Front panel of module
N/A. Outputs cannot be disabled.
ng table lists the Backplane data export devices in your instrument.
User modiable
No Instrument
Input method Location P rocess to disable
function an application software
d
Backplane connectors
Power off th remove the module. (See below.)
e TLA mainframe power and
TLA700/TLA7000 Series Declassication and Security Instructions 5
Clear and Sanitize Procedures
6 TLA700/TLA7000 Series Declassication and Security Instructions
Troubleshooting
How to Sanitize or Clear a Nonfunctional Instrument
If your instrument is not functioning and you need to clear it, remove the power source from the instrument for at least 20 seconds.
To sanitize the instrument, remove the circuit boards and either securely store them in a safe location or destroy them. You can also return the circuit boards to Tektronix; Tektronix will repair and replace the circuit boards as necessary.