Tektronix TLA7012, TLA7016 Reference manual

Technical Reference Manual
TLA7000 Series Mainframes
071-1764-00
This document applies to System Software ver­sion 5.0 and above.
Warning
The servicing instructions are for use by qualified personnel only. To avoid personal injury, do not perform any servicing unless you are qualified to do so. Refer to all safety summaries prior to performing service.
www.tektronix.com
Copyright © Tektronix, Inc. All rights reserved. Licensed software products are owned by Tektronix or its subsidiaries or suppliers, and are protected by national copyright laws and international treaty provisions.
Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supercedes that in all previously published material. Spec ifications and price change privileges reserved.
TEKTRONIX and TEK are registered trademarks of Tektronix, Inc.
Contacting Tektronix
Tektronix, Inc. 14200 SW Karl Braun Drive P.O. Box 500 Beaverton, OR 97077 USA
For product information, sales, service, and technical support:
H In North America, call 1-800-833-9200.
H Worldwide, visit www.tektronix.com to find contacts in your a rea.

Warranty 2

Tektronix warrants that this product will be free from defects in materials and workmanship for a period of one (1) year from the date of shipment. If any such product proves defective during this warranty period, Tektronix, at its option, either will repair the defective product without charge for parts and labor, or will provide a re placement in exchange for the defective product. Parts, modules and replacement products used by Tektronix for warranty work may be new or reconditioned to like new performance. All replaced parts, modules and products become the property of Tektronix.
In order to obtain service under this warranty, Customer must notify Tektronix of the defect before the expiration of the warranty period and make suitable arrangements for the performance of service. Customer shall be responsible for packaging and shipping the defective product to the service center designated by Tektronix, with shipping charges prepaid. Tektronix shall pay for the return of the product to Customer if the shipment is to a location within the country in which the Tektronix service center is located. Customer shall be responsible for paying all shipping charges, duties, taxes, and any other charges for products ret urned to any other locations.
This warranty shall not apply to any defect, failure or damage caused by improper use or improper or inadequate maintenance and care. Tektronix shall not be obligated to furnish service under this warranty a) to repair damage resulting from attempts by personnel other than Tektronix representatives to install, repair or service the product; b) to repair damage resulting from improper use or c onnection to incom patible equipment; c) to repair any damage or malfunction caused by the use of non-Tektronix supplies; or d) to service a product that has been modified or integrated with other products when the effect of such modification or integration increases the time or difficulty of servicing the product.
THIS WARRANTY IS GIVEN BY TEKTRONIX WITH RESPECT TO THE PRODUCT IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED. TEKTRONIX AND ITS VENDORS DISCLAIM ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. TEKTRONIX’ RESPONSIBILITY TO REPAIR OR REPLACE DEFECTIVE PRODUCTS IS THE SOLE AND EXCLUSIVE REMEDY PROVIDED TO THE CUSTOMER FOR BREACH OF THIS WARRANTY. TEKTRONIX AND ITS VENDORS WILL NOT BE LIABLE FOR ANY INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES IRRESPECTIVE OF WHETHER TEKTRONIX OR THE VENDOR HAS ADVANCE NOTICE OF THE POSSIBILITY OF SUCH DAMAGES.

Table of Contents

General Safety Summary v...................................
Service Safety Summary vii....................................
Environmental Considerations viii...............................
Preface ix...................................................
Manual Structure ix................................................
Manual Conventions ix..............................................
Mainframes ix.................................................
Replaceable Parts ix............................................
Related Documentation x...........................................
Introduction xi..............................................
Adjustment and Certification Interval xi................................
Service Strategy xi.................................................
Service Offerings xi................................................
Warranty Repair Service xii.......................................
Calibration and Repair Service xii..................................
Maintenance 1..............................................
Preventing ESD 1.................................................
Inspection and Cleaning 2...........................................
Exterior Inspection 2...........................................
Exterior Cleaning Procedure 3....................................
Interior Inspection 3............................................
Interior Cleaning Procedure 4....................................
Portable Mainframe Removal and Installation Procedures 5.......
Equipment Required 5..............................................
Instrument Covers 6..............................................
Front Panel Display 8.............................................
DVD Drive 10.....................................................
Motherboard 10....................................................
Interface Board 11.................................................
Backplane 12......................................................
Power Supply 13...................................................
Benchtop Mainframe Removal and Installation Procedures 15......
Equipment Required 15..............................................
Instrument Modules 16..............................................
Blower Assembly 16................................................
Removing the Enhanced Monitor Board 19..............................
Power Supply 21...................................................
Mainframe Cover 22................................................
Card Guides 23....................................................
Temperature Sense Board 25..........................................
Front Panel and Display Module 26....................................
EMI DIN Shields 29................................................
Backplane 30......................................................
Repackaging Instructions 33...................................
Packaging 33......................................................
TLA7000 Series Mainframe Technical Reference Manual
i
Table of Contents
Shipping to the Service Center 33......................................
Parts List 35.................................................
Parts Ordering Information 35.........................................
Part Number Revision Level 36....................................
Module Servicing 36............................................
Using the Replaceable Parts List 37....................................
Abbreviations 37...............................................
Mfr. Code to Manufacturer Cross Index 37...........................
ii
TLA7000 Series Mainframe Technical Reference Manual

List of Figures

Table of Contents
Figure 1: Locator diagram 6..................................
Figure 2: Instrument enclosure detail 7.........................
Figure 3: Tilt the panel forward for cable access 8................
Figure 4: Front panel cable locations 9..........................
Figure 5: Dress the cables properly 9...........................
Figure 6: Removing the motherboard 11.........................
Figure 7: Removing the interface board 12.......................
Figure 8: Removing the backplane 13...........................
Figure 9: Location of blower assembly screws 17..................
Figure 10: Removing the blower assembly 18.....................
Figure 11: Removing the blower 18..............................
Figure 12: Removing the enhanced monitor board 19..............
Figure 13: Removing the power supply 21........................
Figure 14: Removing the mainframe cover 22.....................
Figure 15: Removing the top and bottom card guides 24............
Figure 16: Removing the temperature sense board 26..............
Figure 17: Removing the instrument front panel 27................
Figure 18: Installing the new front panel 28......................
Figure 19: Removing the backplane EMI DIN shields 29...........
Figure 20: Removing the backplane 31..........................
Figure 21: Soft power down jumper setting 32....................
Figure 22: External parts 41...................................
Figure 23: Front panel assembly 43.............................
Figure 24: Interface, backplane and motherboard 45..............
Figure 25: Power supply and fans 47............................
Figure 26: Cabinet and chassis assembly 49......................
Figure 27: Circuit boards and chassis parts 51....................
Figure 28: Power supply, monitor, and fan assembly 53............
Figure 29: Slot 0 Interface module 54............................
Figure 30: iView cables 55.....................................
TLA7000 Series Mainframe Technical Reference Manual
iii
Table of Contents

List of Tables

Table i: Tektronix Logic Analyzer Family documentation x........
T able 1: External inspection check list 2........................
T able 2: Internal inspection check list 3........................
Table 3: Equipment required to service the mainframes 5.........
Table 4: Equipment required to service the mainframes 15.........
Table 5: Enhanced monitor board jumpers 20....................
Table 6: Mainframe backplane jumpers 32.......................
Table 7: Parts lists column descriptions 37.......................
iv
TLA7000 Series Mainframe Technical Reference Manual

General Safety Summary

Review the following safety precautions to avoid injury and prevent damage to this product or any products connected to it.
To avoid potential hazards, use this product only as specified.
Only qualified personnel should perform service procedures.
While using this product, you may need to access other parts of a larger system. Read the safety sections of the other component manuals for warnings and cautions related to operating the system.
ToAvoidFireor
Personal Injury
Use Proper Power Cord. Use only the power cord specified for this product and certified for the country of use.
Connect and Disconnect Properly. Do not connect or disconnect probes or test leads while they are connected to a voltage source.
Ground the Product. This product is grounded through the grounding conductor of the power cord. To avoid electric shock, the grounding conductor must be connected to earth ground. Before making connections to the input or output terminals of the product, ensure that the product is properly grounded.
Observe All Terminal Ratings. To avoid fire or shock hazard, observe all ratings and markings on the product. Consult the product manual for further ratings information before making connections to the product.
The inputs are not rated for connection to mains or Category II, III, or IV circuits.
Do not apply a potential to any terminal, including the common terminal, that exceeds the maximum rating of that terminal.
Power Disconnect. The power cord disconnects the product from the power source. Do not block the power cord; it must remain accessible to the user at all times.
Do Not Operate Without Covers. Do not operate this product with covers or panels removed.
Do Not Operate With Suspected Failures. If you suspect there is damage to this product, have it inspected by qualified service personnel.
Avoid Exposed Circuitry. Do not touch exposed connections and components when power is present.
Use Proper Fuse. Use only the fuse type and rating specified for this product.
Do Not Operate in Wet/Damp Conditions.
TLA7000 Series Mainframe Technical Reference Manual
v
General Safety Summary
Do Not Operate in an Explosive Atmosphere.
Keep Product Surfaces Clean and Dry.
Provide Proper Ventilation. Refer to the manual’s installation instructions for
details on installing the product so it has proper ventilation.
Terms in this Manual
Symbols and Terms
on the Product
These terms may appear in this manual:
WARNING. Warning statements identify conditions or practices that could result in injury or loss of life.
CAUTION. Caution statements identify conditions or practices that could result in damage to this product or other property.
These terms may appear on the product:
H DANGER indicates an injury hazard immediately accessible as you read the
marking.
H WARNING indicates an injury hazard not immediately accessible as you
read the marking.
H CAUTION indicates a hazard to property including the product.
The following symbols may appear on the product:
CAUTION
Refer to Manual
WARNING
High Voltage
vi
Protective Ground
(Earth) Terminal
Chassis Ground
Standby
TLA7000 Series Mainframe Technical Reference Manual

Service Safety Summary

Only qualified personnel should perform service procedures. Read this Service Safety Summary and the General Safety Summary before performing any service
procedures.
Do Not Service Alone. Do not perform internal service or adjustments of this product unless another person capable of rendering first aid and resuscitation is present.
Disconnect Power. To avoid electric shock, switch off the instrument power, then disconnect the power cord from the mains power.
Use Care When Servicing With Power On. Dangerous voltages or currents may exist in this product. Disconnect power, remove battery (if applicable), and disconnect test leads before removing protective panels, soldering, or replacing components.
To avoid electric shock, do not touch exposed connections.
TLA7000 Series Mainframe Technical Reference Manual
vii

Environmental Considerations

This section provides information about the environmental impact of the product.
Product End-of-Life
Handling
Observe the following guidelines when recycling an instrument or component:
Equipment Recycling. Production of this equipment required the extraction and use of natural resources. The equipment may contain substances that could be harmful to the environment or human health if improperly handled at the product’s end of life. In order to avoid release of such substances into the environment and to reduce the use of natural resources, we encourage you to recycle this product in an appropriate system that will ensure that most of the materials are reused or recycled appropriately.
The symbol shown to the left indicates that this product complies with the European Union’s requirements according to Directive 2002/96/EC on waste electrical and electronic equipment (WEEE). For information about recycling options, check the Support/Service section of the Tektronix Web site (www.tektronix.com).
Mercury Notification. This product uses an LCD backlight lamp that contains mercury. Disposal may be regulated due to environmental considerations. Please contact your local authorities or, within the United States, the Electronics Industries Alliance (www.eiae.org) for disposal or recycling information.
Restriction of Hazardous
Substances
viii
This product has been classified as Monitoring and Control equipment, and is outside the scope of the 2002/95/EC RoHS Directive. This product is known to contain lead, cadmium, mercury, and hexavalent chromium.
TLA7000 Series Mainframe Technical Reference Manual

Preface

Manual Structure

Manual Conventions

This is the service manual for the TLA7012 Portable Mainframe and the TLA7016 Benchtop Mainframe. For service information on the TLA7PC1, refer to the documentation that came with the product.
This document contains the following information:
H Maintenance contains information and procedures for doing corrective
maintenance on the instruments. Included are instructions for removal and installation of replaceable parts.
H Mechanical Parts List includes tables of all replaceable parts for the
instrument along with the Tektronix part number.
This manual uses certain conventions that you should become familiar with before attempting service.
Mainframes
Replaceable Parts
The TLA7012 Portable Mainframe has a built-in controller and display with room for two TLA plug-in modules. The benchtop mainframe consists of a mainframe with an interface module. Slots are available for installing other modules.
This manual refers to any field-replaceable assembly or mechanical part specifically by its name or generically as a replaceable part. In general, a replaceable part is any circuit board or assembly, such as the hard disk drive, or a mechanical part, such as the I/O port connectors, that is listed in the replaceable parts list.
TLA7000 Series Mainframe Technical Reference Manual
ix
Preface

Related Documentation

The following documents are available as part of the Tektronix Logic Analyzer Family documentation set. The procedures in this manual assume that the service personnel have access to the manuals listed in the following table. Contact your local Tektronix Service Representative for the latest part numbers of the service documentation. All manuals are available at the Tektronix Web Site.
Table i: Tektronix Logic Analyzer Family documentation
Manual name Description
TLA Quick Start User Manuals High--level operational overview
Online Help In-depth operation and User Interface help
Installation Quick Reference Cards High-- level installation information
Installation Manuals Detailed first-time installation information
TLA Product Specifications & Performance Verification Procedures Product specifications and performance verification procedures for
TLA7000 series products
Field upgrade kits Upgrade information for your logic analyzer
Optional Service Manuals Self-service documentation for modules and mainframes
x
TLA7000 Series Mainframe Technical Reference Manual

Introduction

This manual contains information needed to service the TLA7000 series mainframes.
To prevent personal injury or damage to the instrument, consider the following requirements before attempting service:
H Read the General Safety Summary and Service Safety Summary found at the
beginning of this manual.
H The procedures in this manual should only be performed by a qualified
service person.
Be sure to follow all warnings, cautions and notes.

Adjustment and Certification Interval

Generally, you should perform the adjustments and certification (calibration) once per year, or following repairs that may affect adjustment or calibration.

Service Strategy

Service Offerings

This manual supports and contains information needed for periodic maintenance of the instrument. It supports and contains the following information for corrective maintenance:
H Supports removal and replacement of boards or assemblies.
H Supports removal and replacement of the mechanical parts listed in the parts
lists.
This manual does not support component-level fault isolation and replacement.
Tektronix provides service to cover repair under warranty as well as other services that are designed to meet your specific service needs.
Whether providing warranty repair service or any of the other services listed below, Tektronix service technicians are equipped to service the instrument. Services are provided at Tektronix Services Centers and on-site at your facility, depending on your location.
TLA7000 Series Mainframe Technical Reference Manual
xi
Introduction
Warranty Repair Service
Calibration and Repair
Service
Tektronix warrants this product for one year from date of purchase. The warranty is located behind the title page in this manual. Tektronix technicians provide warranty service at most Tektronix service locations worldwide. The Tektronix product catalog lists all service locations worldwide.
In addition to warranty repair, Tektronix Service offers calibration and other services which provide solutions to your service needs and quality standards compliance requirements.
The following services can be tailored to fit your requirements for calibration and/or repair of your portable mainframe.
Service Options. Tektronix Service Options can be selected at the time you purchase your instrument. You select these options to provide the services that best meet your service needs.
Service Agreements. If service options are not added to the instrument purchase, then service agreements are available on an annual basis to provide calibration services or post-warranty repair coverage. Service agreements may be custom­ized to meet special turn-around time and/or on-site requirements.
Service on Demand. Tektronix offers calibration and repair services on a “per-incident” basis that is available with standard prices.
Self Service. Tektronix supports repair to the replaceable-part level by providing for circuit board exchange.
Use this service to reduce down-time for repair by exchanging circuit boards for remanufactured ones. Tektronix ships updated and tested exchange boards. Each board comes with a 90-day service warranty.
For More Information. Contact your local Tektronix service center or sales engineer for more information on any of the Calibration and Repair Services just described.
xii
TLA7000 Series Mainframe Technical Reference Manual

Maintenance

Preventing ESD

This chapter provides information and procedures for removing and replacing components in the TLA7012 Portable Mainframe and the TLA7016 Benchtop Mainframe.
WARNING. To avoid electric shock, always power off the instrument and disconnect the power cord before cleaning or servicing the instrument.
When performing any service which requires internal access to the instrument, adhere to the following precautions to avoid damaging internal circuit boards and their components due to electrostatic discharge (ESD).
CAUTION. Many components within the instrument are susceptible to static discharge damage.
Service the instrument only in a static-free environment. Observe standard handling precautions for static-sensitive devices.
1. Minimize handling of static-sensitive circuit boards.
2. Transport and store static-sensitive circuit boards in their static protected
containers or on a metal rail. Label any package that contains static-sensitive boards.
3. Discharge the static voltage from your body by wearing a grounded antistatic wrist strap while handling these circuit boards.
4. Nothing capable of generating or holding a static charge should be allowed on the work station surface.
5. Handle circuit boards by the edges when possible.
6. Do not slide the circuit boards over any surface.
7. Avoid handling circuit boards in areas that have a floor or work-surface
covering capable of generating a static charge.
TLA7000 Series Mainframe Technical Reference Manual
1
Maintenance

Inspection and Cleaning

The instrument is inspected mechanically and electrically before shipment. It should be free of marks or scratches and should meet or exceed all electrical specifications. To confirm this, inspect for physical damage incurred during transit. Retain the packaging in case shipment for repair is necessary. If there is damage or deficiency, contact your local Tektronix representative.
Cleaning procedures consist of exterior and interior cleaning. Periodic cleaning reduces instrument breakdown and increases reliability. Clean the instrument as needed, based on your operating environment.
Exterior Inspection
Inspect the outside of the instrument for damage, wear, and missing parts. Use Table 1 as a guide. Modules that appear to have been dropped or otherwise abused should be checked thoroughly to verify correct operation and perfor­mance. Immediately repair defects that could cause personal injury or lead to further damage to the benchtop controller, expansion module, or the mainframes that the module plug into.
Table 1: External inspection check list
Item Inspect for Repair action
Front panel Cracks, scratches, deformations,
missing or damaged retainer screws, or ejector handles.
Front and rear connec­tors
Accessories Missing items or parts of items,
Broken shells, cracked insulation, and deformed contacts. Dirt in connectors.
bent pins, broken or frayed cables, and damaged connectors.
Replace defective or missing parts.
Replace defective parts. Clear dirt out of connectors.
Replace damaged or missing parts, frayed cables.
CAUTION. To prevent damage to electrical components from moisture during external cleaning, use only enough liquid to dampen the cloth or applicator.
2
TLA7000 Series Mainframe Technical Reference Manual
Maintenance
Exterior Cleaning
Procedure
Interior Inspection
Clean the exterior surfaces with a soft dry lint-free cloth, or a soft-bristle brush. If any dirt remains, use a soft cloth or swab dipped in a 75% isopropyl alcohol solution. Use a swab to clean narrow spaces around controls and connectors. Do not use abrasive cleaning compounds.
CAUTION. Avoid getting moisture inside the instrument during exterior cleaning; use just enough moisture to dampen the cloth or swab.
Use only deionized water when cleaning. Use a 75% isopropyl alcohol solution as a cleanser and rinse with deionized or distilled water.
Do not use chemical cleaning agents; they may damage the chassis. Avoid chemicals that contain benzene, toluene, xylene, acetone, or similar solvents.
Remove the module covers to access the inside of the instrument for inspection and cleaning. Refer to the Removal and Installation Procedures for detailed information on cover removal. Inspect the internal portions of the modules and the mainframes for damage and wear using Table 2 as a guide. Defects found should be repaired immediately.
Table 2: Internal inspection check list
Item Inspect for Repair action
Circuit boards Loose, broken, or corroded
solder connections. Burned circuit boards. Burned, broken, or cracked circuit-run plating.
Solder connections Cold solder or rosin joints. Return to a Tektronix Service Center.
Wiring and cables Loose plugs or connectors.
Burned, broken, or frayed wiring.
Chassis Dents, deformations, and
damaged hardware.
Return to a Tektronix Service Center.
Firmly seat connectors. Repair or replace parts with defective wires or cables.
Straighten, repair, or replace defective hardware.
CAUTION. To prevent damage from electrical arcing, ensure that circuit boards and components are dry before applying power.
TLA7000 Series Mainframe Technical Reference Manual
3
Maintenance
Interior Cleaning
Procedure
Use a dry, low-velocity stream of air to clean the interior of the modules and the mainframes. Use a soft-bristle brush for cleaning around components. If you must use a liquid for minor interior cleaning, use a 75% isopropyl alcohol solution and rinse with deionized or distilled water.
Clean the exterior (face) of the DVD drive and replaceable hard disk drive cartridge with a soft, clean cloth and a mild detergent.
4
TLA7000 Series Mainframe Technical Reference Manual

Portable Mainframe Removal and Installation Procedures

This section provides procedures for removing and installing mechanical and electrical modules in the portable mainframe. The following procedures provide only high-level remove and replacement procedures. Refer to the Replaceable Parts Lists for additional remove and replace information.
CAUTION. Before doing this or any other procedure in this manual, read the
General Safety Summary and Service Safety Summary found at the beginning of this manual.

Equipment Required

Table 3 lists the tools needed to remove and replace components in the main­frame.
Table 3: Equipment required to service the mainframes
Item number Item Descri pti on
1 Screwdriver handle Accepts Torx driver bits
2 T-15 Torx tip Torx drive bit for T-15 size screws
3 Phillips screwdriver Phillips #1 screwdriver
4 3/16-inch nut driver For motherboard and jack screw removal
5 9/16-inch socket For interface board removal
6 Torque wrench 2 in-lb minimum
NOTE. When installing the screws, use a torque screwdriver and tighten the screws to 8 in-lbs unless otherwise noted.
TLA7000 Series Mainframe Technical Reference Manual
5
Portable Mainframe Removal and Installation Procedures
Interface
board
Backplane
board
Front panel and display
Motherboard
Fan assembly
Hard disk drive
Power
supply DVD drive

Instrument Covers

Figure 1: Locator diagram
WARNING. To avoid electric shock, always power off the instrument and disconnect the power cord before cleaning or servicing the instrument.
Complete the following steps to remove the instrument covers:
1. Disconnect all cords, cables, and probes from the instrument.
2. Carefully remove all instrument modules (if any) from the instrument.
3. Set the instrument on the bottom feet.
4. Remove the six T-15 screws from the right cover and remove the cover.
6
TLA7000 Series Mainframe Technical Reference Manual
Portable Mainframe Removal and Installation Procedures
Pouch
Snap
Top cover
Skid foot
Front
panel/display
Figure 2: Instrument enclosure det ail
Top left cover
Right side
cover
5. Remove the accessory pouch and snap studs (4 T-15 screws).
6. Remove the four skid feet from the left side (4 T-15 screws).
7. Remove the remaining T-15 screws from the top left cover and then remove
the cover.
8. Set the instrument on the rear feet.
TLA7000 Series Mainframe Technical Reference Manual
7
Portable Mainframe Removal and Installation Procedures

Front Panel Display

Complete the following steps to remove the front panel display:
1. Remove the 12 T-15 screws from the front panel trim.
2. Set the instrument back on the bottom feet.
3. Tilt the top of the front panel trim out about 8 inches.
When reinstalling make sure that the alignment pins go into hollow posts (Alignment pins not shown)
Figure 3: Tilt the panel forward f or cable access
4. Disconnect the two display cables and three USB cables from the front panel assembly.
5. Remove the ground wire with a 5/16 in driver.
8
TLA7000 Series Mainframe Technical Reference Manual
Ground
wire
Portable Mainframe Removal and Installation Procedures
Display cables
USB cables
Figure 4: Front panel cable locations
6. Remove the front panel assembly.
Note the following steps when reinstalling the front panel display:
H When connecting the display cable, carefully line up the centers of the plug
and socket before pressing them together.
H To avoid damaging the USB and DVD cables, dress the cables properly just
before you attach the new panel to the chassis. See Figure 5.
Route USB cables below DVD drive to prevent pinching when reinstalling
Keep the ribbon
cables flat
against chassis
Figure 5: Dress the cables properly
TLA7000 Series Mainframe Technical Reference Manual
9
Portable Mainframe Removal and Installation Procedures

DVD Drive

Complete the following steps to remove the DVD drive. Refer to Figure 23 on page 43 for the detailed exploded view drawings. Installation procedures are the reverse of the removal procedures.
1. Remove the instrument covers. (See Instrument Covers on page 6.)
2. Remove the front panel display. (See Front Panel Display on page 8.)
3. Disconnect the ribbon cable and the power cable from the DVD drive.
4. Remove the two screws securing the DVD drive to the chassis.
5. Slide the DVD drive out of the chassis.
6. Remove the four screws securing the DVD drive to bracket assembly.
7. Remove the two screws securing the DVD board and spacer to the DVD
drive.

Motherboard

NOTE. Tighten the two screws securing the DVD board and spacer board to the DVD drive to 2.0 in-lbs. Tighten the four screws securing the DVD drive to the bracket assembly to 2.0 in-lbs.
Complete the following steps to remove the motherboard. Refer to Figure 24 on page 45 for the detailed exploded view drawings. Installation procedures are the reverse of the removal procedures.
1. Remove the instrument covers. (See Instrument Covers on page 6.)
2. Remove the top EMI cover. (Refer to Figure 22 on page 41.)
3. Remove the six screws securing the motherboard to the chassis.
4. Remove the four rear jack screws.
5. Disconnect and pull all cables clear of the motherboard. (Refer to Figure 6
on page 11.)
6. Pass the DVD ribbon cable through chassis to clear the motherboard.
10
7. Move the motherboard forward to clear the USB grounding bracket and then lift board out.
TLA7000 Series Mainframe Technical Reference Manual
Portable Mainframe Removal and Installation Procedures
NOTE. When installing the four jack screws, tighten them to 4 in-lbs.
USB grounding
bracket
Motherboard
DVD cable

Interface Board

Chassis bracket
Figure 6: Removing the motherboard
Complete the following steps to remove the interface board. Refer to Figure 24 on page 45 for the detailed exploded view drawings. Installation procedures are the reverse of the removal procedures.
1. Remove the instrument covers. (See Instrument Covers on page 6.)
2. Remove the top EMI cover. (Refer to Figure 22 on page 41.)
3. Remove the hardware from the I/O bracket -- four BNC nuts, two jack
screws, and two chassis screws. (Refer to Figure 7 on page 12)
4. Gently pull out the I/O bracket.
5. Disconnect the cables from the interface board and move them out of the
way.
6. Remove the five screws securing the interface board to the chassis.
To install the interface board, watch the ground fingers on top left. (Gently bend the board down while pushing it into place.)
TLA7000 Series Mainframe Technical Reference Manual
11
Portable Mainframe Removal and Installation Procedures
NOTE. When installing the BNC nuts and the two jack screws, tighten them to 12 in-lbs ±1.5 in-lbs.
To install, press
downonEMIclipto
prevent damage to
ground fingers.
Screws (5)

Backplane

Jack
screws (2)
BNC nuts and
washers (4)
Screws (2)
Screw (1)
Interface board
assembly
Figure 7: Removing the interface board
Complete the following steps to remove the backplane. Refer to Figure 24 on page 45 for the detailed exploded view drawings. Installation procedures are the reverse of the removal procedures.
1. Remove the instrument covers. (See Instrument Covers on page 6.)
2. Remove the top EMI cover. (Refer to Figure 22 on page 41.)
3. Remove the interface board. (See Interface Board on page 11.)
12
4. Gently remove the interface board from the backplane board.
5. Remove the four screws and four binding posts from the backplane board.
6. Slide the backplane under the chassis post as indicated in Figure 8 on
page 13.
7. Pull out the backplane.
TLA7000 Series Mainframe Technical Reference Manual
Portable Mainframe Removal and Installation Procedures
NOTE. When installing the binding posts, tighten them to 10 in-lbs.
Interface
board
Chassis post

Power Supply

Figure 8: Removing the backplane
Complete the following steps to remove the power supply. Refer to Figure 25 on page 47 for the detailed exploded view drawings. Installation procedures are the reverse of the removal procedures.
1. Remove the top and right plastic covers. (See Instrument Covers on page 6.)
2. Remove bottom cover with the feet.
3. Remove the eight screws (four on the bottom EMI cover and four on the
side) securing the power supply to the chassis.
4. Pull out the assembly.
5. Remove the handle from the assembly.
TLA7000 Series Mainframe Technical Reference Manual
13
Portable Mainframe Removal and Installation Procedures
14
TLA7000 Series Mainframe Technical Reference Manual

Benchtop Mainframe Removal and Installation Procedures

This section provides procedures for removing and installing mechanical and electrical modules in the benchtop mainframe.
CAUTION. Before doing this or any other procedure in this manual, read the
General Safety Summary and Service Safety Summary found at the beginning of this manual.

Equipment Required

Table 4 lists the tools needed to remove and replace components in the main­frame.
Table 4: Equipment required to service the mainframes
Item number Item Descri pti on
1 Flat blade screwdriver Small flat blade screwdriver
2 Cutters Diagonal cutters (for removing cable ties)
3 Screwdriver handle Accepts Torx driver bits
4 T-7 Torx tip Torx drive bit for T-7 size screws
5 T-15 Torx tip Torx drive bit for T-15 size screws
6 T-20 Torx tip Torx drive bit for T-20 size screws
7 Allen wrench A 3/32-inch Allen wrench (hex wrench)
8 Phillips screwdriver Phillips #1 screwdriver
9 Cable ties 4-inch tie-down straps (Tektronix part number
343-0549-00)
NOTE. When installing the screws, use a torque screwdriver and tighten the screws to 8 in-lbs unless otherwise noted.
WARNING. To avoid electric shock, always power off the instrument and disconnect the power cord before cleaning or servicing the instrument.
TLA7000 Series Mainframe Technical Reference Manual
15
Benchtop Mainframe Removal and Installation Procedures

Instrument Modules

CAUTION. To avoid damaging any the instrument or any instrument modules, remove the modules and the Slot 0 Interface module from the chassis before performing any procedures in this section.
To remove the instrument modules and the Slot 0 Interface module from the mainframe, loosen the retaining screws, use the ejector/injector handles to unseat the modules, and then slide the modules out to the mainframe.
To install the modules, slide the modules into the mainframe, and secure the modules with the ejector/injector handles. Use a screwdriver to tighten the retaining screws to 2.5 in-lbs after seating the modules in place.

Blower Assembly

To remove the blower assembly, refer to Figures 9, 10, and 11 while performing the following steps:
1. From the back of the chassis, loosen the five captive screws including the safety ground (refer to Figure 9 for the screw locations).
2. Loosen the four 8-32 hex screws (see Figure 11 on page 18) under the mainframe so that you can easily remove the blower assembly.
3. Remove the cable cover.
4. Unplug the blower cable and set the blower assembly aside on a clean
working surface.
5. To remove the blower, remove the ten screws with (the Allen wrench) holding the shroud part of the blower assembly to the chassis part of the assembly. Set the shroud aside. There are three screws on each side and four on the bottom. See Figure 11.
6. Remove the two sheet metal screws at the top of the blower.
7. Remove the four screws that hold the blower to the chassis part of the blower
assembly.
8. For convenience, replace the two sheet metal screws from step 6 onto the top of the blower.
Install the blower assembly by following the removal procedures in reverse order.
16
TLA7000 Series Mainframe Technical Reference Manual
Benchtop Mainframe Removal and Installation Procedures
NOTE. When reconnecting the blower cables to the chassis, verify that you connect the blower cable to J8, 1/BLOWER.
8-32 Captive
screw/fan housing
8-32 Captive
screw/fan housing
8-32 Captive
screw/fan housing
8-32 Captive
screw/fan housing
Figure 9: Location of blower assembly screws
8-32 Captive screw/Enhance monitor
8-32 Captive screw/cable cover
8-32 Captive screw/Enhance monitor
8-32 Captive
screw/fan housing
TLA7000 Series Mainframe Technical Reference Manual
17
Benchtop Mainframe Removal and Installation Procedures
Power supply
Cable cover
Fan cable
Blower assembly
Figure 10: Removing the blower assembly
Blower assembly
Shroud
Screws (4)
Screws (6)
Screws (4)
Chassis
Screws (2)
Blower
Cable tie
18
Figure 11: Removing the blower
TLA7000 Series Mainframe Technical Reference Manual

Removing the Enhanced Monitor Board

To remove the enhanced monitor board, complete the following steps:
1. Refer to Figure 10 and unscrew the captive screw that attaches the cable cover. Remove the cable cover and set it aside.
2. Unplug the blower cable from the connector labeled 1/BLOWER.
3. Unscrew the two captive screws that attach the monitor board to the
mainframe.
4. Slide the enhanced monitor board out of the mainframe as shown in Figure 12.
Benchtop Mainframe Removal and Installation Procedures
Figure 12: Removing the enhanced monitor board
TLA7000 Series Mainframe Technical Reference Manual
Monitor board
19
Benchtop Mainframe Removal and Installation Procedures
To install the enhanced monitor board, complete the following steps:
1. Refer to Table 5 and verify that the jumpers on the enhanced monitor board are in the default locations before installing the board in the mainframe.
Table 5: Enhanced monitor board jumpers
Jumpers (location) Pins Label on board
J2 (top of board) 1-2 and 3-4 TLA721
J38 (middle of board) 2-3 Blower
J19 (bottom of board) 2-3 Blower
2. Slide the enhanced monitor board into the mainframe as shown in Figure 12. You may have to adjust the enhanced monitor board to engage the connec­tors on the rear of the board.
3. Push the enhanced monitor board into the mainframe to fully mate the rear connectors.
4. Tighten the two screws that attach the enhanced monitor board to the mainframe.
5. Connect the blower cable into the connector labeled 1/BLOWER.
6. Install the cable cover and tighten the captive screw to that attaches to the
mainframe.
20
TLA7000 Series Mainframe Technical Reference Manual

Power Supply

Benchtop Mainframe Removal and Installation Procedures
To remove the power supply from the mainframe, perform Blower Assembly procedure on page 16 and then complete the following steps:
1. Using the handle on the power supply, firmly pull out the power supply from the rear of the mainframe.
2. Remove the two 3/32 hex drive screws and washers to remove the handle from the power supply.
Mainframe
Power supply
Handle
Figure 13: Removing the power supply
Complete the following steps to reinstall the power supply in the mainframe:
1. Reinstall the handle to the power supply if you removed it earlier.
2. Slide the power supply into the mainframe.
3. Push the power supply handle in firmly to ensure that the connectors are
completely seated into the back plane connectors.
4. Reinstall the blower assembly.
TLA7000 Series Mainframe Technical Reference Manual
21
Benchtop Mainframe Removal and Installation Procedures

Mainframe Cover

To remove the mainframe cover, refer to Figure 14 while performing the following steps (Note that this procedure assumes that the mainframe does not include any rails for the rackmount option; if it does, remove the rails before continuing this procedure).
1. Remove the 12 hex drive screws (6 on each side) using a 3/32 Allen wrench.
2. Remove the eight T-7 screws: four on the top front and four on the top rear.
3. Lift the front bottom corners up.
4. After tilting the cover up about 3 inches, lift the cover straight off the
instrument.
Remove screws (20)
Step 1 Step 2
Step 3
Figure 14: Removing the mainfram e cover
22
TLA7000 Series Mainframe Technical Reference Manual
Benchtop Mainframe Removal and Installation Procedures
Complete the following steps to install the mainframe cover (refer to Figure 14 as necessary):
1. Slide the cover over the mainframe.
2. Tilt the rear of the cover in place and then lower the front until the cover
binds slightly (do not force the cover down).
3. Slowly push the cover down until the screw holes on the sides of the cover line up with those on the mainframe. Use care not to damage the front panel label while installing the cover.
4. Install the eight T-7 screws on the top of the mainframe cover; tighten them to4in-lbs.
5. Install the remaining 12 screws on the sides of the mainframe.
6. Tighten all screws.

Card Guides

The card guides at the top and bottom of the mainframe are very similar. The main difference is that the bottom guides include the spring-loaded shutters to redirect air into the mainframe. The procedure for removing both guides is identical. Refer to Figure 15 while performing the following steps:
1. Use a small flat blade screwdriver to pry up the tab of the card guide at the front of the mainframe being careful not to damage the card guide or the mainframe.
2. Gently pull the card guide forward until it pops out of place.
3. Remove the card guide.
To install the card guides refer to Figure 15 while completing the following steps:
NOTE. The bottom card guides are replaced as a unit. These guides are not intended to be disassembled.
1. Slide the card guide towards the rear of the mainframe and allow the front of the card guide to snap into place.
2. Test the card guides in the mainframe and verify that they do not move.
3. Reinstall the mainframe cover.
TLA7000 Series Mainframe Technical Reference Manual
23
Benchtop Mainframe Removal and Installation Procedures
Installing card guides
Slide the card guides toward the rear of
the mainframe; allow the front of the
card guide to snap into place.
Front
Rear
Removing card guides
Gently pull the card guide
forward until it pops out of place.
Figure 15: Removing the top and bottom card guides
24
TLA7000 Series Mainframe Technical Reference Manual

Temperature Sense Board

To remove the temperature sense board complete the following steps:
1. Remove the mainframe cover by following the Mainframe Cover removal
2. Disconnect the ribbon cable from the temperature sense board.
3. Refer to Figure 16 and gently pry back on each retainer holding the
4. Tilt the board forward and lift it out of the holes at the top of the mainframe
Complete the following steps to install the temperature sense board in the mainframe:
1. Refer to Figure 16 and install the temperature sense board in the mainframe
Benchtop Mainframe Removal and Installation Procedures
procedure on page 22.
temperature sense board in place.
being careful not to damage any components on the circuit board.
as shown.
2. Make sure that the circuit board snaps into place under each retainer.
3. Reconnect the ribbon cable.
4. Reinstall the mainframe cover.
TLA7000 Series Mainframe Technical Reference Manual
25
Benchtop Mainframe Removal and Installation Procedures
Temperature sense board
Retainer
Cable
Figure 16: Removing the temperature sense board

Front Panel and Display Module

Perform the following steps to replace the front panel and display module:
1. Remove the mainframe cover by following the Mainframe Cover removal procedure on page 22.
2. Note the orientation of the power switch. (The green LED is toward the front-left side; see Figure 17).
3. Using needle-nose pliers, remove the five wires from the power switch. (The color-coded connections are shown later in the installation procedure).
4. Remove the two T-7 screws from the front panel and remove the front panel.
26
TLA7000 Series Mainframe Technical Reference Manual
Front view
Green LED on left side
Front panel
Benchtop Mainframe Removal and Installation Procedures
Power switch
Five wires
Figure 17: Removing the instrument fr ont panel
5. Unsnap the power switch from the front panel by squeezing the snaps on each side of the switch and pushing the switch through the front of the panel.
NOTE. Before removing the display from the front panel, note the orientation so that you don’t install it reversed
6. Disconnect the ribbon cable from the display assembly.
7. Remove the four screws securing the diaplay assembly to the bracket and
remove the display.
Install the display assembly and front panel by performing the following steps:
1. Install the new display assembly using the four screws removed earlier.
2. Orient the power switch to the front panel so that the four terminals are on
top, and the green LED is toward the front-left side. See Figure 18.
3. Snap the power switch into the front panel.
TLA7000 Series Mainframe Technical Reference Manual
27
Benchtop Mainframe Removal and Installation Procedures
4. Connect the wires to the power switch as shown in Figure 18.
Brown
Red Green Yellow
1254
Green LED
on left side
Five wires
3
Orange
New front panel
Ribbon
cable
Figure 18: Installing the new front panel
5. Connect the ribbon cable from the mainframe to the front panel.
6. Position the front panel in the chassis. If there is a plastic cable retainer in
the way, remove it. Dress the ribbon cable around the display board to avoid pinching the cable.
7. Dress the excess power switch cable towards the back of the chassis, away from the card guides.
8. Attach one T-7 screw on each side of the front panel.
9. Replace the cover and partially install the side cover screws first, and then
the top screws, until the cover is aligned and all of the screws are started.
10. Tighten all of the cover screws.
28
TLA7000 Series Mainframe Technical Reference Manual

EMI DIN Shields

Benchtop Mainframe Removal and Installation Procedures
Perform the following steps to remove the EMI DIN shields:
1. Remove any modules surrounding the slots where you intend to remove the Backplane EMI DIN shields. Refer to Figure 19.
2. Remove two 4-40 Torxdrive T-10 screws that secure each EMI DIN shield to the backplane.
3. Remove EMI DIN shield from the backplane.
Install the EMI DIN shield by reversing the removal procedure.
Polarization hole
Screws (2)
Backplane EMI
DIN shield
Figure 19: Removing the backplane EMI DIN shields
TLA7000 Series Mainframe Technical Reference Manual
29
Benchtop Mainframe Removal and Installation Procedures

Backplane

To remove the backplane from the mainframe, complete the following steps:
1. Follow the instructions on page 16 to remove the blower assembly from the mainframe.
2. Follow the instructions on page 19 to remove the enhanced monitor board from the mainframe.
3. Follow the instructions on page 21 to remove the power supply from the mainframe.
4. Follow the instructions on page 22 to remove the cover from the mainframe.
5. Refer to Figure 20 and disconnect the ribbon cable on the right side of the
backplane.
6. Note the location of the power switch cable at J22 (or from J23) at the top of the backplane and disconnect the cable.
NOTE. If the front panel switch is connected to the backplane at J22, the switch controls the power-on functions. If the switch is connected to J23, the front panel switch is disabled, however, the light still illuminates when the chassis is powered on.
7. From the rear of the mainframe, remove the five 6-32 screws on the top of the backplane, remove the seven 6-32 screws from the center, and then remove the five 6-32 screws from the bottom (refer to Figure 20 if neces­sary).
8. After removing all of the screws from the backplane, remove the backplane from the mainframe by sliding it out of the right side.
30
TLA7000 Series Mainframe Technical Reference Manual
Benchtop Mainframe Removal and Installation Procedures
J24
Power switch
connector
J22
J23
J29
6-32 Screws (17)
Figure 20: Removing the backplane
Connector
0J4
TLA7000 Series Mainframe Technical Reference Manual
31
Benchtop Mainframe Removal and Installation Procedures
Before installing the backplane board in the mainframe verify the correct position and location of the jumpers (refer to Figure 21 and to Table 6).
Install the backplane board following the removal procedures in reverse order.
Table 6: Mainframe backplane jumpers
Location Pins
JP1 No Jumper installed
JP2 pins 2--5
32
Figure 21: Soft power down jumper setting
TLA7000 Series Mainframe Technical Reference Manual
JP1
1 2 3 4 5
JP2

Repackaging Instructions

This section contains the information needed to repackage the instrument for shipment or storage.

Packaging

When repacking the instrument for shipment, use the original packaging. If the packaging is unavailable or unfit for use, contact your local Tektronix representa­tive to obtain new packaging.
Seal the shipping carton with an industrial stapler or strapping tape.

Shipping to the Service Center

Contact the Service Center to get an RMA (return material authorization) number, and any return or shipping information you may need.
If the instrument is being shipped to a Tektronix Service Center, enclose the following information:
H The RMA number.
H The owner’s address.
H Name and phone number of a contact person.
H Type and serial number of the instrument.
H Reason for returning.
H A complete description of the service required.
Mark the address of the Tektronix Service Center and the return address on the shipping carton in two prominent locations.
TLA7000 Series Mainframe Technical Reference Manual
33
Repackaging Instructions
34
TLA7000 Series Mainframe Technical Reference Manual

Parts List

This chapter contains a list of the replaceable parts for the TLA7012 Portable Mainframe and the TLA7016 Benchtop Mainframe. Use this chapter to order replacement parts for your instrument. Refer to the individual module service manuals for replaceable parts for those product modules.
NOTE. The term “module” in this chapter refers to a replaceable subcomponent of the mainframe such as a power supply. It does not refer to a TLA product module.

Parts Ordering Information

Replacement parts are available through your local Tektronix field office or representative.
Changes to Tektronix products are sometimes made to accommodate improved components as they become available and to give you the benefit of the latest improvements. Therefore, when ordering parts, it is important to include the following information in your order.
H Part number (see Part Number Revision Level below)
H Instrument type or model number
H Instrument serial number
H Instrument modification number, if applicable
If you order a part that has been replaced with a different or improved part, your local Tektronix field office or representative will contact you concerning any change in part number.
TLA7000 Series Mainframe Technical Reference Manual
35
Parts List
Part Number Revision
Level
Module Servicing
Tektronix part numbers contain two digits representing the revision level of the part. For most parts in this manual, you will find the letters XX in place of the revision level number.
Part Number Revision Level
670-7918-03
When you order parts, Tektronix will provide you with the most current part for your product type, serial number, and modification (if applicable). At the time of your order, Tektronix will determine the part number revision level needed for your product, based on the information you provide.
Modules can be serviced by selecting one of the following options. Contact your local Tektronix service center or representative for repair assistance.
Module Repair and Return. You may ship your module to Tektronix for repair, after which Tektronix will return it to you.
Revision Level May Show as XX
670-7918-XX
New Modules. You may purchase replacement modules in the same way as other replacement parts.
36
TLA7000 Series Mainframe Technical Reference Manual

Using the Replaceable Parts List

The following table describes each column in the replaceable parts lists.
Table 7: Parts lists column descriptions
Column number
1 Figure & index num-
Column name Description
Figure and index numbers in the exploded view
ber
illustrations.
Parts List
Abbreviations
Mfr. Code to Manufacturer
Cross Index
2 Tektronix part
number
3 and 4 Serial number Column 3 indicates the serial number at which the part
5 Qty Quantity of parts used.
6 Name & description An item name is separated from the description by a
7 Mfr. code Manufacturer code.
8 Mfr. part number Manufacturer’s or vendor’s part number.
Use this part number when ordering replacement parts from Tektronix.
was first effective. Column 4 indicates the serial number at which the part was discontinued. No entries in either column indicates the part is good for all serial numbers.
colon (:). Because of space limitations, an item name may sometimes appear incomplete. Use the U. S. Federal Catalog Handbook H6-1 for further item name identification.
Abbreviations conform to American National Standard ANSI Y1.1-1972.
The table titled Manufacturers Cross Index shows codes, names, and addresses of manufacturers or vendors of components listed in the parts list.
TLA7000 Series Mainframe Technical Reference Manual
37
Parts List
Manufacturers Cross Index
Mfr. code
00779 TYCO ELECTRONICS CORPORATION CUSTOMER SERVICE DEPT ~PO BOX
060D9 TENSOLITE COMPANY PRECISION HARNESS AND ASSEMBLY~3000
06915 RICHCO 5825 N TRIPP AVE~P.O. BOX 804238 CHICAGO, IL 60646 0KB01 STAUFFER SUPPLY CO 810 SE SHERMAN PORTLAND, OR 97214-- 4657 0KB05 NORTH STAR NAMEPLATE INC METAL PRODUCTS~5750 NE MOORE COURT HILLSBORO, OR 97124--6474 0L0L7 RADISYS CORPORATION 5445 NE DAWSON CREEK DRIVE HILLSBORO, OR 97124 1LT13 ARTESYN TECHNOLOGY 7575 MARKET PLACE DR EDEN PRAIRIE, MN 55344
12136 PHC INDUSTRIES INC 1643 HADDON AVE CAMDEN, NJ 08103 26742 METHODE ELECTRONICS INC 7444 WEST WILSON AVE CHICAGO, IL 60656--4548 27264 MOLEX PRODUCTS COMPANY 2222 WELLINGTON CT. LISLE, IL 60532 2W944 PAPST MECHATRONIC CORP AQUIDNECK INDUSTRIAL PARK NEWPORT, RI 02840 3M099 PORTLAND SCREW COMPANY 6520 N BASIN AVE PORTLAND, OR 97217 50356 TEAC AMERICA INC 7733 TELEGRAPH RD~PO BOX 750 MONTEBELLO, CA 90640--6537 52152 3M COMPANY INDUSTRIAL TAPE DIVISION~3M CENTER ST PAUL, MN 55144-- 1000 55566 RAF ELECTRONIC HARDWARE INC 95 SILVERMINE ROAD SEYMOUR, CT 06483 61081 APW ELECTRONIC SOLUTIONS WEST COAST OPERATIONS~6790 FLANDERS
68167 BELKIN COMPONENTS 1303 WALNUT PARKWAY COMPTON, CA 90220 71400 BUSSMANN DIVISION COOPER INDUSTRIES INC~PO BOX
74594 ESCO LLC 14525 SW WALKER ROAD BEAVERTON, OR 97006 75915 LITTELFUSE INC 800 E NORTHWEST HWY DES PLAINES, IL 60016--3049 78189 SHAKEPROOF DIVISION OF ILLINOIS TOOL WORK~ST.
7X318 KASO PLASTICS INC 5720--C NE 121ST AVE, STE 110 VANCOUVER, WA 98682 93907 CAMCAR DIV OF TEXTRON INC 516 18TH AVE ROCKFORD, IL 611045181
TK0EM MOLEX ELECTRONICS FARNHAM ROAD~BORDON HAMPSHIRE, ENGLAND TK0588 UNIVERSAL PRECISION PRODUCT 1775 NW CORNELIUS PASS RD HILLSBORO, OR 97124
TK1163 POLY-- CAST INC 14140 SW 72ND AVE~SUITE 100 TIGARD, OR 97224 TK1269 NORITAKE COMPANY INC ELECTRONICS DIV LA BRANCH~2050 E VISTA
TK1943 NEILSEN MANUFACTURING INC 3501 PORTLAND RD NE SALEM, OR 97303 TK2157 APW ELECTRONIC SOLUTIONS 14100 DANIELSON ST POWAY, CA 92064 TK2565 VISION PLASTICS INC 26000 SW PARKWAY CENTER DRIVE WILSONVILLE, OR 97070 TK6314 MCX INC 1315 OREGON AVE KLAMATH FALLS, OR 97601--6540
Manufacturer Address City, State, Zip code
HARRISBURG, PA 17105--3608
3608~M/S 38--35
VANCOUVER, WA 98661
COLUMBIA HOUSE BLVD~#120
SAN DIEGO, CA 92121--2902
DRIVE
ST LOUIS, MO 63178--4460
14460
ELGIN, IL 60120
CHARLES ROAD
COMPTON, CA 90220
BELLA WAY
38
TLA7000 Series Mainframe Technical Reference Manual
Parts List
TLA7000 Series Mainframe Technical Reference Manual
39
Parts List
Replaceable Parts List
Fig. & index number
22-1 211-- 1093-- XX 4 SCREW,MACHINE; 4--40 X 0.25,FLH 100 DEG,STL BLK
-2 016--1441--XX 1 ACCESSORY POUCH; BLACK CORDURA 80009 016-- 1441-- XX
-3 211--0721--XX 35 SCREW,MACHIN E; 6--32 X 0.375,PNH,STL,CDPL,T-- 15 TORXDR80009 211--0721--XX
-4 200--4946--XX 1 COVER; TOP LEFT,EMI TK1943 200-- 4946-- XX
-5 200--4940--XX 1 COVER, RIGHT (COSMETIC) TK2565 200--4940--XX
-6 343--1213--XX 1 CLAMP,PWR CORD; POLYMIDE TK1163 343--1213--XX
-7 200--4947--XX 1 COVER; BOTTOM,COSMETIC WITH FEET TK1943 200-- 4947-- XX
-8 200--4939--XX 1 COVER,FRONT;PROTECTIVE,PLASTIC TK2565 200--4939-- XX
-9 335--1322--XX 1 LABEL, INDENTI FICATION (TEKTROINIX LOGO) 80009 335--1322--XX
-10 101--0169--XX 1 TRIM RING;FRONT 80009 101--0169--XX
-11 348--1817--XX 4 FOOT, SKID 80009 348--1817--XX
-12 200--4948--XX 1 COVER; TOP COSMETIC TK1943 200-- 4948-- XX
-13 355--0298--XX 4 STUD.SNAP; 0.570 DIA,0.165 THK,STAINLESS STEEL TK0588 355-- 0298-- XX
Tektronix part number
Serial no. effective
Serial no. discont’d
Qty Name & description
OXIDE,T7
Mfr. code
0KB01 211--1093--XX
Mfr. part number
40
TLA7000 Series Mainframe Technical Reference Manual
12
Parts List
2
1
3
13
3
3
3
11
10
9
8
4
5
3
6
7
3
Figure 22: External parts
TLA7000 Series Mainframe Technical Reference Manual
41
Parts List
Replaceable Parts List
Fig. & index number
23--1 441--2425--XX 1 CHASSI S ASSY; MAIN TK1943 441--2425--XX
-2 343--1701--XX 1 CLAMP,CABLE; WITH ADHESIVE BACK 06915 PCC --12
-3 650--4815--XX 1 HARD DRIVE ASSY; TLA7012 REMOVABLE HARD DISK
-4 211--1174--XX 4 SCREW,MACHINE; W/HEAVY PATCH THREADLOCKING
-5 351--1118--XX 2 GUIDE,HD; REMOVABLE,3.5 INCH HARD DISK DRIVE TK2565 3511118 00
-6 211--0721--XX 12 SCREW,MACHIN E; 6--32 X 0.375,PNH,STL,CDPL,T-- 15 TORXDR80009 211072100
Tektronix part number
Serial no. effective
Serial no. discont’d
Qty Name & description
DRIVE ASSEMBLY W/OUT SW INSTALLED
MATERIAL; 6--32 X 0.312 L,PNH,STL CAD PLT,T15
Mfr. code
80009 650--4815--XX
0KB01 211--1174-- XX
Mfr. part number
-7 407--5068--XX 1 BRACKET,HD; REMOVABLE 3.5 INCH HARD DRIVE CARTRIDGE
-8 211--0734--XX 4 SCREW,MACHINE; 6--32 X 0.25O,FLH100,STL,CDPL,T--10 TORX DR
-9 174--5057--XX 3 CABLE ASSY; USB 2.0 TK6314 174505700
-10 679--5974--XX 3 CKT BD SUBASSY; USB ADAPTER BOARD ,UNTESTED 80009 679--5974--XX
-11 366--0837--XX 2 KNOB,CAP;0.650 DIAMETER,SOFT FEEL COATING 80009 366--0837--XX
-12 366--0836--XX 2 KNOB,CAP; 0.430 D,SOFT FEEL COATING,TEK SILVER GRAY 80009 366--0836--XX
-13 366--0846--XX 1 KNOB; GENERAL PURPOSE 80009 366--0846--XX
-14 650--4676--XX 1 DISPLAY/FRONT PANEL ASSY; 15 INCH LCD,WITH TOUCH PANEL,LOGIC NALYZER,PORTABLE; TLA7012 OPT 18
-14 650--4804--XX 1 DISPLAY/FRONT PANEL ASSY; 15 INCH LCD W/OUT TOUCH SCREEN, STANDARD,LOGIC ANALYZER,PORTABLE; TLA7012
-15 174--5053--XX 1 CABLE ASSY; DISPLAY ADAPTER TO INTERFACE,30 PIN 060D9 174505300
-16 119--7123--XX 1 DISK DRIVE; OPTICAL,CD--RW/DVD--R/RW DVD+R/RW,16.7 MB/SEC,650MEG/8.5GIG,IDE/ATAPI;TEAC MODEL DV--W28E-- 793,ROHSC ONV
-17 679--5915--XX 1 CKT BD SUBASSY; DVD--CD/RW ADAPTER 80009 679--5915--XX
-18 211--0888--XX 2 SCREW,METRIC; M--2 X 0.4 X 6MM,PHILLIPS PAN,ZINC PLATED,PHIL PAN HEAD,STEEL
-19 129--1618--XX 1 SPACER; DVD--CD/RW SLIMLINE DRIVE ADAPTER,PLASTIC TK2565 129161800
-20 211--0950--XX 4 SCREW,MACHINE; M2X.4X3L,PHL, PNH, STL NI PL 0KB01 0310248--0
-21 407--5070--XX 1 BRACKET,DVD--CD/RW; ADAPTER FOR DVD--CD/RW,SLIM­LINE
-22 174--4671--XX 1 CA ASSY,SP; ULTRA DMA/ATA HARD DISK DRIVE,IDE,18.0 L 68167 F2N1107--18INCH
-23 174--5017--XX 1 CABLE ASSEMBLY; DVD POWER 060D9 174-- 5017-- XX
-24 407--5069--XX 1 BRACKET,RHDD; SATA COMBO CABLE,3.5 INCH REMOVABLE HARD DISK DRIVE RECEPTACLE
-25 174--5169--XX 1 CABLE ASSY; SATA COMBO,HARD DRIVE CABLE 27264 174516900
TK1943 407506800
93907 MACHINE SCREW:
6--32 X .250, T1
80009 650--4676--XX
80009 650--4804--XX
50356 DV--W28EA--793
0KB01 211--0888--XX
TK1943 407507000
TK1943 407506900
42
TLA7000 Series Mainframe Technical Reference Manual
Parts List
J390
J69
Motherboard
PL33 IDE
Interface
board
15
25
22
18
17
16
23
19
C40
Motherboard
6
24
20
21
20
2
5
1
6
3
7
14
13
12
6
Display
6
11
Interface board
R890
6
10
Figure 23: Front panel assembly
TLA7000 Series Mainframe Technical Reference Manual
4
9
RP21
PL19
Motherboard
8
43
Parts List
Replaceable Parts List
Fig. & index number
24--1 214--3903--XX 4 SCREW,JACK; 4-- 40 X 0.312 LONG,0.188 H HEX HEAD
-2 174--5056--XX 1 CABLE ASSY; 30 POSITION LVDS 060D9 174505600
-3 210--0457--XX 2 NUT,PL,ASSEM WA; 6--32 X 0.312,STL CD PL,W/LOCKWASH-ER78189 511--061800--XX
-4 039--0164--XX 1 MOTHER BOARD 0L0L7 ABGD00-- P20-- 1G
-5 210--1039--XX 4 WASHER,LOCK; 0.521 ID,INT,0.025 THK,SST 0KB01 1224-- 02-- XX-- 0541C
-6 220--0497--XX 4 NUT,PLAIN,HEX; 0.5-- 28 X 0.562 HEX,BRS CD PL 0KB01 220-- 0497--XX
-7 211--1206--XX 2 SCREW,JACK; 2-- 56 ID X 4-- 40 OD,.188 HEX,SS 749087-- 7
-8 116--1121--XX 1 BACKPLANE; CIRCUIT BD ASSY,CUSTOM VXI BACKPLANE 61081 VXIBP--1648190 R.A
-9 211--0721--XX 18 SCREW,MACHIN E; 6--32 X 0.375,PNH,STL,CDPL,T-- 15 TORX
-10 129--1613--XX 4 SPACER;POST TK0588 129--1613--XX
-11 174--5137--XX 1 CABLE ASSEMBLY; (20 PIN ATX POWER) 060D9 174--5137--XX
-12 664--5920--XX 1 CIRCUIT BD ASSY; INTERFACE,FUNCTIONAL BOARD
-13 174--5070--XX 1 CABLE ASSY; ATX FRONT PANEL 060D9 174--5070-- XX
-14 174--5073--XX 1 CABLE ASSY; BACKLIGHT CONTROL 060D9 174--5073--XX
-15 174--5071--XX 1 CABLE ASSY; USB 2.0 INTERFACE 060D9 174--5071--XX
-16 407--5075--XX 1 BRACKET ASSEMBLY,REAR I/O (WITH LABEL & GASKET) TK1943 407507500
-17 343--1701--XX 2 CLAMP,CABLE; WITH ADHESIVE BACK 06915 PCC --12
-18 174--5052--XX 1 CABLE ASSY: PCI SEM I --RIGID FLEX,INTERFACE TO
Tektronix part number
Serial no. effective
Serial no. discont’d
Qty Name & description
STAND OFF,4--40 INT THD, X 0.312 THD EXT 4-- 40
DR
TESTED LEVEL
MOTHER BOARD
Mfr. code
55566 4750--3--12 (+LOCK-
80009 664--5920--XX
TK0EM 12243--XX01
Mfr. part number
WASHER)
211072100
44
TLA7000 Series Mainframe Technical Reference Manual
Parts List
3
15
18
Motherboard
13
PL22
1
9
Backlight
PL26
14
LVDS cable
9
Display
Nut
GND
post
17
Motherboard
2
3
4
6
9
5
7
6
5
16
8
Fans
PL24
PL27
9
10
11
J150
J280
J260
9
J140
J69
12
Figure 24: Interface, backplane and motherboard
Motherboard
RP28
TLA7000 Series Mainframe Technical Reference Manual
45
Parts List
Replaceable Parts List
Fig. & index number
25--1 211--0721--XX 10 SCREW,MACHINE; 6--32 X 0.375,PNH,STL,CD PL,T--15 TORXDR80009 211--0721--XX
-2 436--0296--XX 1 TRAY,FAN; CHASSIS ASSY,W/FANS MOUNTED TK1943 436--0296--XX
-3 119--7143--XX 2 FAN,TUBEAXIAL; 60MM,12VDC,0.12A,1.44W,3600RPM, W/2
-4 211--1213--XX 8 SCREW, METRIC 5 X 10MM, FLATHEAD, STL, ZINC, POSI 0KB01 211--1213--XX
-5 351--0979--XX 1 GUIDE,CARD; GUIDE,DIN 41612;ACCOM C MALE,FR ONT
-6 407--4459--XX 1 BRACKET; HANDLE BRACKET,PLASTIC 7X318 1428
-7 367--0477--XX 1 HANDLE,CARRYING; DUAL DUROMETER MOLDED
-8 378--0449--XX 1 SHUTTER ASSY; INCLUDING FRAME,ACTUATOR, FIN,
-9 119--4933--XX 1 POWER SUPPLY ASSY 80009 119--4933--XX
Tektronix part number
Serial no. effective
Serial no. discont’d
Qty Name & description
PIN CONN
PANEL,3 X 32
HANDLE, POLYPROPYLENE HANDLE VINYL GRIP SECTION
SPRING
Mfr. code
80009 2410ML--04W--B20--
7X318 1426
12136 PT 3170
7X318 2TEK1550
Mfr. part number
P00
46
TLA7000 Series Mainframe Technical Reference Manual
Parts List
Fanplugto
Backplane board
1
2
3
4
5
8
1
9
Figure 25: Power supply and fans
TLA7000 Series Mainframe Technical Reference Manual
6
7
1
47
Parts List
Replaceable parts list
Fig. & index number
26-1 212--0193--XX 12 SCREW, EXT RLV: 8-- 32 X 0.375 BUTTON HEAD,
-2 211--1093--XX 8 SCREW, MACHINE: 4--40 X 0.25, FLH 100 DEG, STL
-3 200--4547--XX 1 COVER: MAINFRAME, AL TK1943 200--4547--XX
-4 441--2191--XX 1 CHASSIS ASSY: MAIN, AL TK1943 441--2191--XX
-5 348--1542--XX 4 FOOT, CABINET: BLACK RUBBER 74594 348-- 1542-- XX
Tektronix part number
Serial no. effective
Serial no. discont’d
Qty Name & description Mfr. code Mfr. part number
CABINET AND CHASSIS ASSEMBLY
HEX DRIVE, STAINLESS STEEL, BLACK OXIDE FINISH, 0.093 DRIV
BLK OXIDE, T7
0KB01 ORDER BY
DESCRIPTION
0KB01 211--1093--XX
48
TLA7000 Series Mainframe Technical Reference Manual
Parts List
2
3
1
Figure 26: Cabinet and chassis assembly
4
5
TLA7000 Series Mainframe Technical Reference Manual
49
Parts List
Replaceable parts list
Fig. & index number
27-1 260--2682--XX 1 SWITCH, PUSH: SPST, GOLD OVER NICKEL
-2 333--4521--XX 1 PANEL,FRONT ASSEMBLY; BENCH TOP, DISPLAY 0KB05 333--4521--XX
-3 119--7163--XX 1 DISPLAY, 128 X 32 ACTIVE DOT MATRIX; GRAPHIC
-4 211--0721--XX 4 SCREW,MACHINE; 6--32 X 0.375, PNH,STL T--15
-5 366--1538=XX 2 PUSH BUTTON; IVORY GRAY,0.3 X 0.665 H TK1163 366--1538=XX
-6 174--3697--XX 1 CABLE ASSY: RIBBON, CABLE TEMP
-7 679--3219--XX 1 CIRCUIT BD ASSY: TEMP SENSE 80009 679--3219--XX
-8 211--0720--XX 17 SCR, ASSEM WSHR: 6--32 X 0.500, PNH, STL, CDPL,
-9 118--9417--XX 1 BACKPLANE VXI: BACKPLANE VXI COMPATIBLE
-10 343--0775--XX 2 CABLE, CLAMP: RIBBON, 1.0X1.0, GRAY, POLYVI-
-11 378--0438--XX 13 BAFFLE ASSY: VXI SLOT, SINGLE, SHUTTER 80009 378--0438--XX
-12 351--1007--XX 13 GUIDE, SINGLE: PLASTIC 80009 351--1007--XX
-13 334--9920--XX 1 MARKER, IDENT: LABEL, FRONT BOTTOM SLOT,
-14 333--4206--XX 5 PANEL, FRONT: DOUBLE, BLANK, EMI, AL, PAINTED
Tektronix part number
212--0112-- XX 2 SCREW,MACHINE:8--32 X 0.188,TRH,SST POZ 0KB01 OR DER BY
211-- 1093-- XX 2 SCREW,MACHINE:4--40 X 0.25,FLH 100 DEG,STL
Serial no. effective
Serial no. discont’d
Qty Name & description Mfr. code Mfr. part number
CIRCUIT BOARDS AND CHASSIS PARTS
CONTACT, 0.4V @ 28V, ILLUMINATED BUTTON, PANEL MNT W/CABLE
VDF MODULE
TORX DR
SENSE/BACKPLANE, 28AWG, 2x15, 2x10, 2x15
T--15 TORX DR
WITH 13 C--SIZE SLOTS ELECTRONIC AUTOMATIC
NYL, W/URETHANE FOAM TAPE BACKING
0.010 LEXAN, 1.25 X 15.60, BACKGROUND SILVER GRAY, TLA721
SILVER GRAY
BLK OXIDE,T7
80009 260-- 2682-- XX
80009 119--7163--XX
80009 211--0721--XX
TK2469 174--3697--XX
0KB01 ORDER BY
DESCRIPTION
80009 118--9417--XX
52152 80610029243/3484--
1000
0KB05 334--9920--XX
TK1943 333--4206--XX
DESCRIPTION
0KB01 211--1093--XX
50
TLA7000 Series Mainframe Technical Reference Manual
Parts List
6
8
1
3
2
1
14
4
5
7
9
10
13
12
11
Figure 27: Circuit boards and chassis parts
TLA7000 Series Mainframe Technical Reference Manual
51
Parts List
Replaceable parts list
Fig. & index number
28-1 679--6146--XX 1 CIRCUIT BD ASSY: ENHANCED MONITOR
-2 333--4236--XX 1 PANEL, MONITOR: ENHANCED, 0.062 AL, W/LEXAN
-3 214--3903--XX 4 SCREW, JACK: 4--40 X 0.312 EXT THD, 4--40 INT
-4 211--0747--XX 4 SCREW, MACHINE: 6--32 X 0.188, PNH, STL, CDPL,
-5 200--4344--XX 1 COVER: BLOWER CABLE, 0.040 A1 ALLOY TK1943 200--4344--XX
-6 380--1112--XX 1 HOUSING: BLOWER HOUSING BLOWER TK1943 380--1112--XX
-7 212--0193--XX 10 SCREW, EXT RLV: 8-- 32 X 0.375 BUTTON HEAD,
-8 119--7089--XX 1 FAN, DC: BLOWER, 48V, DUAL INLET, 450 CFM,
-9 212--0400--XX 4 SCREW, MACHINE: 8--32 X 0.250, PNH, STL, ZINC,
-10 334--9921--XX 1 MARKER, IDENT: LABEL, REAR POWER RATING,
-11 119--5553--XX 1 POWER SUPPLY: VXI MAINFRAME, 925W 80009 119-- 5553-- XX
-12 367--0494--XX 1 HANDLE: EJECTOR POWER SUPPLY TK1943 367--0494--XX 0BD
-13 211--0932--XX 2 SCREW: SHLDR, 8--32 X 0.187 OD X 0.125 L, 0.187 L 24931 PZ--6--3
Tektronix part number
Serial no. effective
Serial no. discont’d
Qty Name & description Mfr. code Mfr. part number
POWER SUPPLY, MONITOR, AND BLOWER
(CONTAINS ITEMS 1 THRU 4)
OVERLAY
THD, 0.188 HEX, STEEL, CADPLATE
T--15
HEX DRIVE, STAINLESS STEEL, BLACK OXIDE FINISH, 0.093 DRIV
177 W, WITH 6 SCREWS
T--20
0.010 LEXAN, 1.500 X 7.500, BACKGROUND SILVER GRAY
80009 679-- 6146-- XX
TK1943 333423600
0KB01 214--3903--01
0KB01 ORDER BY
DESCRIPTION
0KB01 212--0193--XX
80009 119--7089--XX
3M099 BY DESCRIPTION
0KB05 334--9921--XX
52
TLA7000 Series Mainframe Technical Reference Manual
Parts List
13
12
1
11
2
3
4
6
5
7
Figure 28: Power supply, monitor, and fan assembly
8
9
10
6
TLA7000 Series Mainframe Technical Reference Manual
53
Parts List
Replaceable parts List
Fig. & index number
29-1 650--4733--XX 1 SLOT 0 INTERFACE MODULE 80009 650--4733--XX
Tektronix part number
664--5924--XX 1 CIRCUIT BD ASSY; SLOT 0, FUNCTIONAL BOARD
Serial no. effective
Serial no. discont’d
Qty Name & description Mfr. code Mfr. part number
TESTED (NOT SHOWN)
80009 664-- 5924-- XX
Figure 29: Slot 0 Interface module
54
TLA7000 Series Mainframe Technical Reference Manual
Replaceable parts List
Fig. & index number
30-1 012--1614--XX 1 CA ASSY:INTEROPTIBILITY ADAPTER CABLE 060D9 012--1614--XX
-2 174--4583--XX 1 CA ASSY:SMB TO BNC ADAPTER 060D9 174--4583--XX
Tektronix part number
Serial no. effective
1
Serial no. discont’d
Qty Name & description Mfr. code Mfr. part number
Parts List
Figure 30: iView cables
2
TLA7000 Series Mainframe Technical Reference Manual
55
Parts List
56
TLA7000 Series Mainframe Technical Reference Manual
Loading...