This document applies to TLA System Software
version 5.1.
Warning
These servicing instructions are for use by
qualified personnel only. To avoid personal injury,
do not perform any servicing unless you are
qualified to do so. Refer to all safety summaries
prior to performing service.
Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supercedes
that in all previously published material. Specifications and price c hange privileges reserved.
TEKTRONIX and TEK are registered trademarks of Tektronix, Inc.
Contacting Tektronix
Tektronix, Inc.
14200 SW Karl Braun Drive
P.O. Box 500
Beaverton, OR 97077
USA
For product information, sales, service, and technical support:
HIn North America, call 1-800-833-9200.
HWorldwide, visit www.tektronix.com to find contacts in your area.
Warranty 6
Tektronix warrants that the parts and modules (“parts”) that it manufactures and sells will be free from defects in
materials and workmanship for a period of three (3) months from the date of shipment. If any such part proves
defective during this warranty period, Tektronix, at its option, either will repair the defective part without charge,
or will provide a replacement in exchange for the defective part. Parts and modules used by Tektronix for
warranty work may be new or reconditioned to like new performance. All replaced parts and m odules become the
property of Tektronix.
In order to obtain service under this warranty, Custom er must notify Tektronix of the defect before the expiration
of the warranty period and make suitable arrangements for the performance of service. Customer shall be
responsible for packaging and shipping the defective part to the service center designated by Tektronix, with
shipping charges prepaid. Tektronix shall pay for the return of the part to Customer if the shipment is to a location
within the country in which the Tektronix service center is located. Customer shall be responsible for payi ng all
shipping charges, duties, taxes, and any other charges for parts returned to any other locations.
This warranty shall not apply to any defect, failure or damage caused by improper use or improper or inadequate
maintenance and care. Tektronix shall not be obligated to furnish service under this warranty a) to repair damage
resulting from attempts by personnel other than Tektronix representatives to install, repair or service the part; b) to
repair damage resulting from improper use or connection to incompatible equipment; c) to repair any damage or
malfunction caused by the use of non-Tektronix supplies; or d) to service a part that has been modified or
integrated with other products or parts when the effect of such modification or integration increases the time or
difficulty of servicing the part.
THIS WARRANTY IS GIVEN BY TEKTRONIX WITH RESPECT TO THE PART IN LIEU OF ANY OTHER
WARRANTIES, EXPRESS OR IMPLIED. TEKTRONIX AND ITS VENDORS DISCLAIM ANY IMPLIED
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. TEKTRONIX’
RESPONSIBILITY TO REP AIR OR REPLACE DEFECTIVE PARTS IS THE SOLE AND EXCLUSIVE
REMEDY PROVIDED TO THE CUSTOMER FOR BREACH OF THIS W ARRANTY. TEKTRONIX AND ITS
VENDORS WILL NOT BE LIABLE FOR ANY INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL
DAMAGES IRRESPECTIVE OF WHETHER TEKTRONIX OR THE VENDOR HAS ADV ANCE NOTICE OF
THE POSSIBILITY OF SUCH DAMAGES.
Warranty 9(b)
Tektronix warrants that the media on which this software product is furnished and the encoding of the programs on
the media will be free from defects in m aterials and workmanship for a period of three (3) months from the date of
shipment. If any such medium or encoding proves defective during the warranty period, Tektronix will provide a
replacement in exchange for the defective medium. Except as to the media on which this software product is
furnished, this software product is provided “as is” without warranty of any kind, either express or implied.
Tektronix does not warrant that the functions contained in this software product will meet Customer’s
requirements or that the operation of the programs will be uninterrupted or error-free.
In order to obtain service under this warranty, Custom er must notify Tektronix of the defect before the expiration
of the warranty period. If Tektronix is unable to provide a replacement that is free from defects in materials and
workmanship within a reasonable time thereafter, Customer may terminate the license for this software product
and return this software product and any associated materials for credit or refund.
THIS WARRANTY IS GIVEN BY TEKTRONIX WITH RESPECT TO THE PRODUCT IN LIEU OF ANY
OTHER WARRANTIES, EXPRESS OR IMPLIED. TEKTRONIX AND ITS VENDORS DISCLAIM ANY
IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
TEKTRONIX’ RESPONSIBILITY TO REPLACE DEFECTIVE MEDIA OR REFUND CUSTOMER’S
PA YMENT IS THE SOLE AND EXCLUSIVE REMEDY PROVIDED TO THE CUSTOMER FOR BREACH OF
THIS WARRANTY. TEKTRONIX AND ITS VENDORS WILL NOT BE LIABLE FOR ANY INDIRECT,
SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES IRRESPECTIVE OF WHETHER TEKTRONIX
OR THE VENDOR HAS ADVANCE NOTICE OF THE POSSIBILITY OF SUCH DAMAGES.
Table of Contents
TLA6UP Option 10
General Safety Summaryv...................................
Service Safety Summaryvii....................................
Table 2--1: TLA6UP Option 15 parts list2--1......................
Table 3--1: TLA6UP Option 35 parts list3--2......................
Table 3--2: Software not covered by the software setup3--3..........
Table 3--3: TLA user file suffixes3--4.............................
Table 4--1: TLA6UP Option 42 parts list4--2......................
TLA6UP Logic Analyzer Field Upgrade Kit Instruction Manual
iii
Table of Contents
iv
TLA6UP Logic Analyzer Field Upgrade Kit Instruction Manual
General Safety Summary
Review the following safety precautions to avoid injury and prevent damage to
this product or any products connected to it.
To avoid potential hazards, use this product only as specified.
Only qualified personnel should perform service procedures.
While using this product, you may need to access other parts of a larger system.
Read the safety sections of the other component manuals for warnings and
cautions related to operating the system.
ToAvoidFireor
Personal Injury
Use Proper Power Cord. Use only the power cord specified for this product and
certified for the country of use.
Connect and Disconnect Properly. Do not connect or disconnect probes or test
leads while they are connected to a voltage source.
Ground the Product. This product is grounded through the grounding conductor
of the power cord. To avoid electric shock, the grounding conductor must be
connected to earth ground. Before making connections to the input or output
terminals of the product, ensure that the product is properly grounded.
Observe All Terminal Ratings. To avoid fire or shock hazard, observe all ratings
and markings on the product. Consult the product manual for further ratings
information before making connections to the product.
The inputs are not rated for connection to mains or Category II, III, or IV
circuits.
Connect the probe reference lead to earth ground only.
Do not apply a potential to any terminal, including the common terminal, that
exceeds the maximum rating of that terminal.
Power Disconnect. The power switch disconnects the product from the power
source. See instructions for the location. Do not block the power switch; it must
remain accessible to the user at all times.
Do Not Operate Without Covers. Do not operate this product with covers or panels
removed.
Do Not Operate With Suspected Failures. If you suspect there is damage to this
product, have it inspected by qualified service personnel.
Avoid Exposed Circuitry. Do not touch exposed connections and components
when power is present.
Use Proper Fuse. Use only the fuse type and rating specified for this product.
TLA6UP Logic Analyzer Field Upgrade Kit Instruction Manual
v
General Safety Summary
Do Not Operate in Wet/Damp Conditions.
Do Not Operate in an Explosive Atmosphere.
Keep Product Surfaces Clean and Dry.
Provide Proper Ventilation. Refer to the manual’s installation instructions for
details on installing the product so it has proper ventilation.
Terms in this Manual
Symbols and Terms
on the Product
These terms may appear in this manual:
WARNING. Warning statements identify conditions or practices that could result
in injury or loss of life.
CAUTION. Caution statements identify conditions or practices that could result in
damage to this product or other property.
These terms may appear on the product:
HDANGER indicates an injury hazard immediately accessible as you read the
marking.
HWARNING indicates an injury hazard not immediately accessible as you
read the marking.
HCAUTION indicates a hazard to property including the product.
The following symbols may appear on the product:
CAUTION
Refer to Manual
Mains Disconnected
OFF (Power)
vi
WARNING
High Voltage
Mains Connected
ON (Power)
TLA6UP Logic Analyzer Field Upgrade Kit Instruction Manual
Protective Ground
(Earth) Terminal
Standby
Earth Terminal
Chassis Ground
Service Safety Summary
Only qualified personnel should perform service procedures. Read this Service
Safety Summary and the General Safety Summary before performing any service
procedures.
Do Not Service Alone. Do not perform internal service or adjustments of this
product unless another person capable of rendering first aid and resuscitation is
present.
Disconnect Power. To avoid electric shock, switch off the instrument power, then
disconnect the power cord from the mains power.
Use Care When Servicing With Power On. Dangerous voltages or currents may
exist in this product. Disconnect power, remove battery (if applicable), and
disconnect test leads before removing protective panels, soldering, or replacing
components.
To avoid electric shock, do not touch exposed connections.
TLA6UP Logic Analyzer Field Upgrade Kit Instruction Manual
vii
Environmental Considerations
This section provides information about the environmental impact of the
product.
Product End-of-Life
Handling
Observe the following guidelines when recycling an instrument or component:
Equipment Recycling. Production of this equipment required the extraction and
use of natural resources. The equipment may contain substances that could be
harmful to the environment or human health if improperly handled at the
product’s end of life. In order to avoid release of such substances into the
environment and to reduce the use of natural resources, we encourage you to
recycle this product in an appropriate system that will ensure that most of the
materials are reused or recycled appropriately.
The symbol shown to the left indicates that this product
complies with the European Union’s requirements
according to Directive 2002/96/EC on waste electrical and
electronic equipment (WEEE). For information about
recycling options, check the Support/Service section of the
Tektronix Web site (www.tektronix.com).
Mercury Notification. This product uses an LCD backlight lamp that contains
mercury. Disposal may be regulated due to environmental considerations. Please
contact your local authorities or, within the United States, the Electronics
Industries Alliance (www.eiae.org) for disposal or recycling information.
Restriction of Hazardous
Substances
viii
This product has been classified as Monitoring and Control equipment, and is
outside the scope of the 2002/95/EC RoHS Directive. This product is known to
contain lead, cadmium, mercury, and hexavalent chromium.
TLA6UP Logic Analyzer Field Upgrade Kit Instruction Manual
Preface
L
,
V
,
V
,
V
,
f
fix
TLASWV4.4,V
4.3,V
4.2,V
4.1
Professiona
lTL
A
L
TLASWV3.2SecondEditio
nTL
A
y
pgg
p
TLA6UPOpti
sionaloperatingsystem,256MB
This instruction manual contains specific information about the TLA6UP logic
analyzer field upgrades. The logic analyzer field upgrades consist of software
and hardware options for the TLA600 Series Logic Analyzers. Use Table i,
below, to explore possible upgrade paths.
Table i: TLA6UP Logic Analyzer Field Upgrade Matrix
New capability desiredCurrent configuration and
TLA software version
Add More DRAM and a Larger
HDD
Provides a total of 512 MB
DRAM and/or replace current
hard disk drive with a larger,
ed, bootable MAX hard disk
drive.
Works with either Windows 98
Second Edition or Windows 2000
Professional operating system.
Add New Software Features
Add new functionality to existing
TLA600 logic analyzers b
upgrading to Version 5.1 TLA
Application Software.
Requires Windows 2000 Professional o
RAM minimum, 512 MB recommended.
eratingsystem,256 MB
TLA6xx Std or Option 1J with
TLA SW V5.1
TLA6xx Std or Option 1J with
T
ASWV4.4
or V4.0
TLA6xx Std or Option 1J with
T
ASWV3.2
TLA6xx Std or Option 1J with
TLA SW V5.1
TLA6xx Std or Option 1J with
TLA SW V4.4,V4.3,V4.2,V4.1,
or V4.0
TLA6xx Std or Option 1J with
TLA SW V3.2
4.3
4.2
Current
operating system
Windows 2000
Professional
Windows 2000
Pro
4.1
,
essional
Windows 98
Second Edition
Windows 2000
Professional
Windows 2000
Professional(With restore media) AND
Windows 98
Second Edition
Please order
TLA6UP Option 10
TLA6UP Option 10
6UP Option 35
(With restore media) AND
TLA6UP Option 42
(Without restore media)
TLA6UP Option 10
6UP Option 35
(With restore media) AND
TLA6UP Option 42
(Without restore media)
--
TLA6UP Option 35
(Without restore media)
TLA6UP Option 35
(With restore media) AND
on 42
TLA6UP Option 42
(Without restore media)
TLA6UP Logic Analyzer Field Upgrade Kit Instruction Manual
ix
Preface
y
correlateddirectlyontheTLA600
L
(With
d
ia)
AND
SoftwareandWindows200
0
TLA6UPOpt
ion4
2
L
requirements:256MBytemini
TLASWV3.2SecondEditio
nTL
A
g
increasingstatespeedorrecor
d
Table i: TLA6UP Logic Analyzer Field Upgrade Matrix (Cont.)
New capability desiredPlease orderCurrent
Add New iView External Oscilloscope Capability
Add new iView capability to view
datafrom TDS oscilloscopes
correlated directl
logic analyzer1.
Upgrade Logic Analyzer State
Speed and Record Length
Enhance your logic analyzer by
increasin
length. Run the PowerFlex Utility
to inform you what upgrades are
available. Instructions to obtain
an upgrade are provided.
on the TLA600
state speed or record
Current configuration and
TLA software version
TLA6xx Std or Option 1J with
TLA SW V5.1
TLA6xx Std or Option 1J with
T
A SW V4.4, V4.3,V4.2,V4.1,
or V4.0
TLA6xx Std or Option 1J with
ASWV3.2
T
Any TLA600 series logic analyzer
with TLA SW V5.1, V4.4, or V4.3
Any TLA600 series logic
analyzer with TLA SW V4.2 or
earlier
operating system
Windows 2000
Professional
Windows 2000
Professional
Windows 98
Second Edition
Windows 2000
Professional
Windows 2000
Professional
TLA6UP Option 15
TLA6UP Option 15
TLA6UP Option 35
restore me
(Without restore media)
TLA6UP Option 15
6UP Option 35
(With restore media) AND
LA6UP Option 42
(Without restore media)
Run the PowerFlex Utility software
located on the instrument and then
purchase the appropriate PowerFlex kit.
TLA6UP Option PF or
visit www.tektronix.com/LA for the
PowerFlex Utility software
Add Cart:Any TLA600 mainframe--Choice of either K4000 or LACART
Add Rackmount KitAny TLA600 mainframe--016-1790-04 (Same as used with
TDS6000 and TDS7000 instruments)
Add Wheeled Transport CaseAny TLA600 mainframe--016-1522-xx
1
For a list of supported TDS oscilloscopes, please visit our Web site at www.tektronix.com/la.
Service and Upgrade Notes
To prevent personal injury or damage to the instrument, consider the following
requirements before attempting service:
HRead the General Safety Summary and Service Safety Summary found at the
beginning of this manual.
HOnly qualified service personnel should perform the procedures in this
manual.
Be sure to follow all warnings, cautions and notes.
x
TLA6UP Logic Analyzer Field Upgrade Kit Instruction Manual
Adjustment and Certification Interval
Generally, you should perform the adjustments and performance verification
procedures described in the TLA600 Logic Analyzer Series Service Manual
(071-0728-xx) once per year, or following repairs that may affect adjustment or
calibration.
Service Offerings
Tektronix provides service to cover repair under warranty as well as other
services that are designed to meet your specific service needs.
Whether providing warranty repair service or any of the other services listed
below, Tektronix service technicians are equipped to service your logic analyzer.
Services are provided at Tektronix Services Centers.
Preface
Warranty Repair Service
Calibration and Repair
Service
The warranty for this product is located behind the title page in this manual.
Tektronix technicians provide warranty service at most Tektronix service
locations worldwide. The Tektronix product catalog lists all service locations
worldwide, or you can visit us on our Customer Services World Center Web site
at:
Tektronix.com/Measurement/Service
In addition to warranty repair, Tektronix Service offers calibration and other
services which provide solutions to your service needs and quality standards
compliance requirements.
The following services can be tailored to fit your requirements for calibration
and/or repair of your logic analyzer.
Service Options. Tektronix service options can be selected at the time you
purchase your instrument. You select these options to provide the services that
best meet your service needs. Tektronix Service Options are available at the time
you order your instrument. Contact your local Tektronix Sales Office for more
information.
Service Agreements. If service options are not added to the instrument purchase,
then service agreements are available on an annual basis to provide calibration
services or post-warranty repair coverage. Service agreements may be customized to meet special turn-around time and/or on-site requirements.
Service on Demand. Tektronix offers calibration and repair services on a
“per-incident” basis that is available with standard prices.
TLA6UP Logic Analyzer Field Upgrade Kit Instruction Manual
xi
Preface
Self Service. Tektronix supports repair to the replaceable-part level by providing
for circuit board exchange.
Use this service to reduce down-time for repair by exchanging circuit boards for
remanufactured ones. Tektronix ships updated and tested exchange boards. Each
board comes with a 90-day service warranty.
For More Information. Contact your local Tektronix service center or sales
engineer for more information on any of the Calibration and Repair Services just
described.
xii
TLA6UP Logic Analyzer Field Upgrade Kit Instruction Manual
TLA6UP Option 10
TLA6UP Option 10: MAX HDD and MAX DRAM Upgrade
TLA6UP Option 10 supports replacing your existing hard disk drive with a
greater capacity hard disk drive, and upgrading to 512 MB of DRAM memory
for your TLA600 series logic analyzer.
Instruments
Parts List
TLA600 Series Logic AnalyzersAll Serial Numbers
Table 1--1: TLA6UP Option 10 parts list
QuantityPart numberDescription
2ea156-9074-xx256 MB DRAM -- Total of 512 MB
1ea119-6832-xxHard Disk Drive (no software loaded)
1ea003-0008-xxSpudger tool for removing the trim ring
1eaN/ATLA6UP kit label
1eaN/ATLA600 BIOS floppy disk
1eaN/AIBM\Hitachi HDD Feature Tool floppy disk
TLA6UP Logic Analyzer Field Upgrade Kit Instruction Manual
1--1
TLA6UP Option 10: MAX HDD and MAX DRAM Upgrade
Minimum Tool and Equipment List
Table 1--2: Tools required for installing upgrade
Installation Prerequisite
Item
no.
1Screwdriver handle
2T-15 Torx tipUsed for removing most the instru-
3T-20 Torx tipUsed for removing the handle
4#1 Phillips screwdriverScrewdriver for removing Phillips
NameDescription
Accepts TorxR-driver bits
ment’s screws. TorxR-driver bit for
T-15 size screw heads
hardware. TorxR-driver bit for T-20
size screw heads
screws, hard drive.
General tool
number
620-440
640-247
640-250
Standard tool
These instructions assume that you are familiar with servicing the instrument. If
you need further details for disassembling or reassembling the instrument, refer
to the TLA600 Series Logic Analyzer Service Manual (071-0728-XX). You can
also contact your nearest Tektronix Service Center for installation assistance.
CAUTION. To prevent static discharge damage, service this product only in a
static-free environment. Always wear a grounded wrist strap, grounded foot
strap, and static resistant apparel while installing this kit.
1--2
TLA6UP Logic Analyzer Field Upgrade Kit Instruction Manual
TLA6UP Option 10: MAX HDD and MAX DRAM Installation
The following instructions guide you through the process of replacing the
existing hard disk drive with a greater capacity, but unformatted, hard disk drive.
These instructions additionally guide you through the process of upgrading to
512 MB of DRAM memory.
Back Up Your Software
Before performing these procedures, take steps to protect the contents of your
hard disk drive by backing up any files, applications and personal documents.
Refer to Back Up Files on page 3--4 for more details. Unless you have also
ordered Option 35, TLA Application Software and Windows Operating SystemUpgrade, use the backup media that was shipped with the instrument to reinstall
the operating system and applications.
Preparation
Be sure to observe the following precautions to avoid damaging the logic
analyzer while preparing to service it. Contact your nearest Tektronix, Inc.,
Service Center or Tektronix Factory Service Center for installation assistance.
CAUTION. Many components within the instrument are susceptible to static-discharge damage.
Service only in a static-free environment. Observe standard handling precautions
for static-sensitive devices.
Always wear a grounded wrist strap, grounded foot strap, and static-resistant
apparel while installing this kit.
WARNING. Dangerous voltages may be present. Before performing any procedure
in this subsection, disconnect the power cord from the line voltage source.
Failure to do so could cause serious injury or death.
HDo not handle static-sensitive components on boards.
HTransport and store static-sensitive boards in their original containers or on
conductive foam. Label any package that contains static-sensitive assemblies.
TLA6UP Logic Analyzer Field Upgrade Kit Instruction Manual
1--3
TLA6UP Option 10: MAX HDD and MAX DRAM Installation
HWear anti-static wrist strap while handling the boards to discharge the static
voltage from your body.
HDo not allow anything capable of holding or generating a static charge on
the work surface.
HAvoid handling boards in areas that have a floor or work surface cover that
is capable of generating a static charge.
Remove the Trim
Remove the logic analyzer trim to gain access to either the TLA60X closed face
bracket or the TLA61X/62X flat panel display. You will need a screwdriver with
both a size T-15 Torx tip and a size T-20 Torx tip to perform this procedure.
Removal
Remove the trim as shown in Figure 1--1 on page 1--5 and Figure 1--2 on
page 1--6, using the following procedure.
1. Turn the logic analyzer off.
2. Remove the power cord and all probes.
3. Remove the top cover trim.
a. Remove the accessory pouch; it snaps off.
b. Remove the four T--15 Torx-drive screws that secure the top cover trim
to the instrument. The T--15 Torx-drive screws also secure the snap rings
to the top cover.
c. Remove the top cover trim from the instrument.
4. Remove carrying handle and right/left side trim.
a. Remove the T--20 Torx-drive screws that secure the handle to the
instrument and then remove the handle.
b. Slide the side trim panels toward the rear of the instrument allowing the
tabs to clear the cover openings, then pull out to remove the panels from
the instrument.
1--4
NOTE. You may want to place a small strip of adhesive tape over the elastomeric
On/Standby button to prevent losing it when you remove the trim ring.
TLA6UP Logic Analyzer Field Upgrade Kit Instruction Manual
5. Remove the front panel trim. Use the spudger tool that came with this kit to
6. Remove the input panel; Tilt the instrument onto its cord-wrap feet and
T-15 Torx-drive screws (4)
Snap ring (4)
Left side trim
TLA6UP Option 10: MAX HDD and MAX DRAM Installation
pry on the edges of the trim ring to release the three plastic snaps. Grasp the
trim ring by its top edge and pull toward you to gently remove it from the
instrument.
remove the three T-15 Torx-drive screws that secure the input panel to the
instrument.
Top cover trim
Elastomeric
On/Standby button
Front panel trim
To remove the trim ring,
use the spudger tool to
pry loose the snaps.
Then, grasp the top edge
and flex it toward you
before pulling upward.
Figure 1--1: TLA60X trim removal
Carrying handle
Input panel
T-15 Torx-drive screws (3)
Right side trim
T-20 Torx-drive
screws (2)
TLA6UP Logic Analyzer Field Upgrade Kit Instruction Manual
1--5
Loading...
+ 53 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.