Tektronix TLA6202, TLA6203, TLA6204 Performance Verification

xx
TLA6000 Series Logic Analyzer
ZZZ
Product Specications & Performance Verication
Technical Reference
Revision A
This document applies to TLA System Software Version 5.7 and above
These servicing instructions are for use by qualied personnel only. To avoid personal injury, do not perform any servicing unless you are qualied to do so. Refer to all safety summaries before performing service.
www.tektronix.com
P077048400*
*
077-0484-00
Copyright © Tektronix. All rights reserved. Licensed software products are owned by Tektronix or its subsidiaries or suppliers, and are protected by national copyright laws and international treaty provisions.
Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supersedes that in all previously published material. Specications and price change privileges reserved.
TEKTRONIX and TEK are registered trademarks of Tektronix, Inc.
MagniVu and iView are registered trademarks of Tektronix, Inc.
Contacting Tektronix
Tektronix, Inc. 14150 SW Karl Braun Drive P.O . B o x 5 00 Beaverton, OR 97077 USA
For product information, sales, service, and technical support:
In North America, call 1-800-833-9200. World wi de , visi t www.tektronix.com to nd contacts in your area.
Table of Contents
General safety summary ............ ................................ ................................ .............. iii
Service safety summary............................................................................................ v
Preface ............................................................................................................. vii
Related Doc
Specications .................... .................................. ................................ ................. 1
Atmospheric Characteristics............... ................................ ................................ ... 2
System Characteristics ......... .................................. ................................ ............. 2
Performance Verication Procedures............................................................................ 17
Summary Verication ........................................................................................ 17
Test Eq u
Functional Verication ....... ................................ ................................ ................ 18
Certication ......................... ................................ ................................ .......... 20
Performance Verication Procedures......... ................................ .............................. 20
Threshold Accuracy Test........................................... ................................ .......... 22
Setup and Hold...................................... ................................ .......................... 25
Fixtures.................. ................................ ................................ ...................... 29
Test
Threshold Accuracy Test Fixture ........................................................................... 29
Setup and Hold Test Fixture ................. ................................ ................................ 30
Calibration Data Report..................... ................................ ................................ ...... 32
TLA6000 Test Record.................... ................................ .................................. .. 32
Test Data ....................................................................................................... 32
umentation ..................................................................................... vii
ipment................................ ................................ ................................ 18
TLA6000 Series Product Specications & Performance Verication i
Table of Contents
List of Figure
Figure 1: Dimensions of the TLA6000 series logic analyzer................. ................................ 15
Figure 2: Setting trigger parameters. .... ... . ... . ... .... ... . ... . ... . . ... ... . ... . ... . ... .... ... . ... . ... .... ... . ... 23
Figure 3: Set the trigger states ... ................................ ................................ ................ 27
Figure 4: Threshold Accuracy test xture ...................................................................... 29
Figure 5: Solder square pins to the SMA connector......... .................................. ................ 30
Figure 6: Solder the SMA connectors together .......................... ................................ ...... 31
Figure 7: Completed xture with termination and coupler ........... ................................ ........ 31
List of Tables
Table 1: Atmospheric characteristics............................................................................. 2
Table 2: Backplane interface ...................................................................................... 2
Table 3: System trigger and external signal input latencies (Typical) ........................................ 2
Table 4: System trigger and external signal o utput latencies(Typical)........................................ 3
Table 5: External signal interface.............. ................................ .................................. . 3
Table 6: Display system .......................... ................................ ................................ . 5
Table 7: Front-panel interface...................... ................................ ............................... 5
Table 8: Rear-panel interface...................................................................................... 6
Table 9: AC power source.... ................................ .................................. ................... 6
Table 10: Transportation and storage............................................................................. 7
Table 11: Cooling................................................................................................... 7
Table 12: Input parameters (with probes)........................................................................ 7
Table 13: Analog output ........................................................................................... 8
Table 14: Channel width and depth............................................ ................................ ... 8
Table 15: Clocking .. ................................ .................................. ............................. 9
Table 16: Trigger system ......................... .................................. .............................. 12
Table 17: MagniVu acquisition . . ... ... . ... . ... . ... .. ... ... . ... . ... . ... .. ... ... . ... . ... . ... .. ... ... . ... . ... . ... .. 14
Table 18: Data placement....... ................................ .................................. ................ 14
Table 19: NVRAM ................ .................................. ................................ .............. 14
Table 20: Mechanical ............................................................................................. 15
Table 21: Test equipment................... ................................ .................................. .... 18
Table 22: Parameters checked by verication procedures .................................................... 20
s
ii TLA6000 Series Product Specications & Performance Verication
General safety summary
General safet
To avoid re or personal
injury
y summary
Review the fo this product or any products connected to it.
To avoid pot
Only qualied personnel should perform service procedures.
While using this product, you may need to access other parts of a larger system. Read the safety sections of the other component manuals for warnings and cautions r
Use proper power cord. Use only the power cord specied for this product and certied for the country of use.
Connect and disconnect properly. Do not connect or disconnect probes or test leads while they are connected to a voltage source.
Ground the product. This product is grounded through the grounding conductor of the power cord. To avoid electric shock, the grounding conductor must be connected to earth ground. Before making connections to the input or output terminals of the product, ensure that the product is properly grounded.
llowing safety precautions to avoid injury and prevent damage to
ential hazards, use this product only as specied.
elated to operating the system.
Observe all terminal ratings. To avoid re or shock hazard, observe all ratings and markings on the product. Consult the product manual for further ratings information before making connections to the product.
The inputs are not rated for connection to mains or Category II, III, or IV circuits.
Connect the p robe reference lead to earth ground only.
Power disconnect. The power cord disconnects the product from the power source. Do not block the power cord; it must remain accessible to the user at all times.
Do not operate without covers. Do not operate this product with covers or panels removed.
Do not operate with suspected failures. If you suspect that there is damage to this product, have it inspected by qualied service personnel.
Avoid exposed circuitry. Do not touch exposed connections and components when power is present.
Use proper fuse. Use only the fuse type and rating s pecied for this product.
TLA6000 Series Product Specications & Performance Verication iii
General safety summary
Termsinthismanual
Symbols and terms on the
product
Do not operate i
Do not operate in an explosive atmosphere.
Keep product surfaces clean and dry.
Provide prop
on installing the product so it has proper ventilation.
These terms may appear in this manual:
WARNING.
in injury or loss of life.
CAUTION
damage to this product or other property.
These t
erms may appear on the product:
DANGER indicates an injury hazard immediately accessible as you read the ma
n wet/damp conditions.
er ventilation. Refer to the manual's installation instructions for details
Warning statements identify conditions or practices that could result
. Caution statements identify conditions or practices that could result in
rking.
WARNING indicates an injury hazard not immediately accessible as you
the marking.
read
CAUTION indicates a hazard to property including the product.
The following symbol(s) may appear on the product:
iv TLA6000 Series Product Specications & Performance Verication
Service safety summary
Service safet
ysummary
Only qualifie safety summary and the General safety summary before performing any service procedures.
Do not service alone. Do not perform internal service or adjustments of this product unless another person capable of rendering rst aid and resuscitation is present.
Disconnect power. To avoid electric shock, switch off the instrument power, then disconnect the power cord from the mains power.
Use care when servicing with power on. Dangerous voltages or currents may exist in this p test leads before removing protective panels, soldering, or replacing components.
To avoi
d personnel should perform service procedures. Read this Service
roduct. Disconnect power, remove battery (if applicable), and disconnect
d electric s hock, do not touch exposed connections.
TLA6000 Series Product Specications & Performance Verication v
Service s afety summary
vi TLA6000 Series Product Specications & Performance Verication
Preface
This document lists the characteristics and specications of the TLA6000 series logic analyzers. It also includes the performance verication procedures. Microproces
sor-related products and individual logic analyzer probes have their
own documentation for characteristics and specications.
Related Documentation
To prevent p
ersonal injury or damage consider the following requirements before
attempting service:
The proced
ures in this manual should be performed only by qualied service
personnel.
Read the G
eneral Safety Summary and Service Safety Summary found at
the beginning of this manual.
Be sure t
The fol
o follow all warnings, cautions, and notes in this manual.
lowing list and table provide information on the related documentation available for your Tektronix product. For additional information, refer to the Tektronix Web site (www.tektronix.com/manuals).
Related documentation
Item Purpose
TLA Quick Start User Manuals
Online Help
Installation Reference Sheets High-level installation information
Installation Manuals
XYZs of Logic A nalyzers
Declassication and Securities instructions Data security concerns specic to sanitizing
Application notes
Product Specications & Performance Verication Procedures
TPI.NET Documentation
Field upgrade kits
Optional Service Manuals Self-service documentation for modules and
High-level operational overview
In-depth operation and UI help
Detailed rst-tim e installation information
Logic analyzer basics
or removing memory devices from Tektronix products
Collection of logic analyzer application specic notes
TLA Product specications and performance verication procedures
Detailed information for controlling the logic analyzer using .NET
Upgrade information for your logic analyzer
mainframes
TLA6000 Series Product Specications & Performance Verication vii
Preface
viii TLA6000 Series Product Specications & Performance Verication
Specications
The following tables list the specications for the TLA6000 series logic analyzers. All specications are guaranteed unless noted Typ i c a l. Typical characteristics describe typ
ical or average performance and provide useful reference information.
Specications that are marked with the indirectly
The performance limits in this specication are valid with these conditions:
For optimum performance using an external oscilloscope, please consult the documentation for any external oscilloscopes used with your Tektronix logic analy requirements.
)inthePerformance Verication chapter of this document.
The instrument must be in an environment with temperature, altitude, humidity, and vibration within the operating limits described in these specica
The instrument must have had a warm-up period of at least 30 minutes.
The instrument must have been calibrated/adjusted at an ambient temperature between +20 °C and +30 °C.
zer to determine the warm-up period and signal-path compensation
tions.
symbol are checked directly (or
TLA6000 Series Product Specications & Performance Verication 1
Specications
Atmospheric C
haracteristics
The following table lists the Atmospher ic characteristics of components in the TLA6000 series logic analyzers.
Table 1: Atm
Characteristic Description
Temperatur
Relative Humidity
Altitude
ospheric characteristics
e
Operating (no media in CD or DVD drive)
+5 °C to +40 °C (+41 °F to +104 °F), 11 °C/hr (52 °F/hr) maximum gradient, noncondensing (derated 1 °C (34 °F) per 305 m (1000 ft) above 1524 m (5000 ft) altitude)
Nonoperating (no media in drive)
-20 °C to +60 °C (-4 °F to +104 °F), 15 °C/hr (59 °F/hr) maximum gradient, noncondensing
Operating (no media in drive)
5% to 80% relative humidity, up to +30 °C (+86 °F), 75% from +30 to +40 °C (+86 °F to +104 °F) noncon
Nonop
5% to 9
Oper
To 3 0
Nonoperating
12,190 m (40,000 ft )
densing. Maximum wet bulb temperature: +29.4 °C (+85 °F)
erating (no media in drive)
0% relative humidity, noncondensing. Maximum wet bulb temperature: +40 °C (+104 °F)
ating
00 m (9843 ft), (derated 1 °C (34 °F) per 305 m (1000 ft) above 1524 m (5000 ft) altitude.
System Characteristics
ble 2: Backplane interface
Ta
Characteristic Description
0 MHz ±100 ppm
Clock10 Frequency (system clock)
able 3: System trigger and external signal input latencies (Typical)
T
ogic analyzer source characteristic
L
External system trigger input to LA probe tip
External Signal In to LA probe tip via Signals 3, 4 (TTLTRG 0,1)
External Signal In to LA probe tip via Signals 1, 2 (ECLTRG 0,1)
1
In the Waveform window, triggers are always marked immediately except when delayed to the rst sample. In the Listing window, triggers are always marked on the next sample period following their occurrence.
2
Clk represents the time to the next master clock at the destination logic analyzer module. With asynchronous clocking this represents the delta time to the next sample clock. With synchronous sampling this represents the time to the next master clock generated by the setup of the clocking state machine and the supplied SUT clocks and qualication data.
3
Signals 1 and 2 (ECLTRG0, 1) are limited to a broadcast mode where only one source can drive the signal node at any one time. The signal source can be used to drive any combination of destinations.
1
2
23
1
escription
D
–626 ns
–535 ns + Clk
–627 ns + Clk
2 TLA6000 Series Product Specications & Performance Verication
Specications
Table 4: System
Logic analyze
LA probe tip to
LA probe tip t
trigger and external signal output latencies(Typical)
r source characteristic
external system trigger out (skid)
o External Signal Out via Signal 3, 4 (TTLTRG 0,1)
1
2
3
Deacripton
794 ns + Smpl
OR function 793 ns + Smpl
AND functio
LA probe ti
1
SMPL represents the time from the event to the next valid data sample at the probe tip of the LA module. With asynchronous sampling, this represents the delta time to the next sample clock. With MagniVu asynchronous sampling, this represents 500 ps or less. With synchronous sampling, this represents the timetothe next master clock generated by the setup of the clocking state machine, the system-under-test supplied clocks, and the qualication dat
2
Skid is commonly referred to as the system level system trigger and signaling output latency. This is the absolute time from when the event rst appears at the input probe tips of a module to when the corresp onding event that it generates appears at the system trigger or external signal outputs.
3
All signal output latencies are validated to the rising edge of an active (true) high output.
4
Signals 1 and 2 (ECLTRG0, 1) are limited to a broadcast mode where only one source can drive the signal node at any one time. The signal source can be used to drive any combination of destinations.
n
p to External Signal Out via Signals 1, 2 (ECLTRG0,1)
34
803 ns + Smpl
793 ns + Smp
l
a.
Table 5: External signal interface
Characteristic Description
System Trigger Input
External Signal Input
Input levels 0 V to 3.0 V
Minimum input voltage swing
Threshold range 0.5 V to 1.5 V
Threshold step size 50 mV
Input destination
Input Mode
Minimum Pulse Width 12 ns
Active Period Accepts system triggers during valid acquisition periods via real-time
Maximum Input Voltage 0 to + 5 V peak
Input Destination
Input levels 0 V to 3.0 V
Minimum input voltage swing
Threshold range 0.5 V to 1.5 V
Threshold step size 50 mV
Input Mode
Input Bandwidth
1
Active Period Accepts s ignals during valid acquisition periods via real-time gating
Maximum Input Voltage 0 V to 5 V peak
TTL compatible input via rear panel mounted BNC connectors
300 mV
System trigger
Falling edge sensitive, latched (active low)
gating, resets system trigger input latch between valid acquisition periods
TTL compatible input via rear panel mounted BNC connectors
Signal 1, 2, 3, 4
300 mV
Active (true) low, level sensitive
Signal 1, 2 Signal 3, 4
50 MHz square wave minimum 10 MHz square wave minimum
TLA6000 Series Product Specications & Performance Verication 3