Features & Benets
Comprehensive Set of Signal Integrity Tools that Allow You to Quickly Isolate, Identify, and Debug Complex Signal Integrity Issues
Glitch Trigger and Storage – Allows you to trigger on and highlight
al signal integrity problems. Not only can the TLA6000 Series
potenti trigger on the problem, but by highlighting suspected problems in red, you will be able to easily determine which signals you need to investigate further iCapture – Route the suspected signal to the analog output of the TLA6000 using the exclusive Tektronix iCapture feature. Th is
tes the need to double-probe with an oscilloscope probe,
elimina reducing time to debug iView – Time-correlated view of both logic analyzer and oscilloscope data to trace the SI p roblem across the digital and analog domain
Performance and Ease of Use to Debug, Validate, and Optimize Digital Systems
125 ps Resolution MagniVu™ Acquisition to Accurate ly See Signal Relationshi State Speed – Sample your fastest synchronous buses with clock rates up to 800 MHz and data rates up to 1.25 Gb/s 15 in. Display, with Optional Touch Screen to See More of Your Data and Navigate Efciently through Your Data 3 Models w ith 68/102/136 Channels and Up to 128 Mb Record Length offer Flexi Drag-and-Drop Triggering – Simply drag any one of eight different trigger types from a table onto the waveform and the TLA will automatically set up the trigger conditions. Eliminates errors, improves repeatability, and saves time Drag-and-Drop Measurements – Simply drag an icon from the measuremen a table of results. Saves time, removes complexity, and reduces measurement uncertainty
Analysis T
FPGA DDR A Broad Selection of Microprocessor and Bus Support MIPI CSI and DSI Debug
ps in Your System
ble Solutions to Fit Any Budget
t toolbar and drop it on your signal of interest and get
ools for Debugging and Validating Today’s Digital Systems
Applications
Hardware Validation and Debug
Digital
Monitoring, Measurement, and Optimization of Digital Hardware Performance
Embedded Software Integration, Debug, and Verication
Data Sheet
Efciently Debug and Validate Your Digital System at a Price You Will Like!
The affordable TLA6000 Series of logic analyzers offer the performance needed to debug, validate, and optimize the functionality of your digital system. The TLA6000 Series also provides a comprehensive set of signal integrity deb
ug tools that allow you quickly isolate, identify, and characterize elusive and hard-to-n d problems. Add a broad range of support for today’s applications, and you have the ideal tool to help you meet all of the debug challenges of today’s digital designs.
The TLA6000 Series allows you to effectively validate and d ebug the functionality of your digital designs:
Use the patented 8 GHz Mag niVu technology to accurately measure timing relationships. The single, integrated acquisition architecture of the TLA6000 Series eliminates the timing skew problems inherent in other logic analyzer architectures
Capture on buses with clock rates up to 800 MHz and data rates up to
1.25 Gb/s
Buy the capability you need now and upgrade as your measurement needs grow
Quickly isolate events through a simple and intuitive drag-and-drop trigger setup
Easily summarize your design’s performance with sophisticated drag-and-drop measurements such as frequency, period, pulse width, duty cycle, and edge count
View data in a variety of time-correlated formats including waveform, listing, graph, disassembly, source code, or compare
Find Tough Signal Integrity Problems
Today’s logic analyzers not only need to help troubleshoot functional issues in your design, but also need to help nd signal integrity problems caused by crosst help debug these problems, the TLA6000 Series includes a comprehensive suite of signal debug tools.
These tools allow you to:
alk, termination mismatches, ground bounce, and other issu es. To
Use glitch trigger to monitor selected signals in your design and trigger when a signal integrity problem is found on any one of these signals
Automatically tag any found signal integrity problems, allowing you to quickly identify the signals of interest
Gain more insight into the problem using the exclusive iCapture functionality to view both digital and analog data through a single probe
Use iView to see time-correlated digital and analog displays of you r data, letting you track the signal integrity problem across both analog and digital domains
TLA6000 Selection Guide
Characteristic
Channels High-speed Timing Maximum Timing
Sample Rate (Quarter/Half/Full channel)
Maximum State Clock Rate (Quarter/Half/Full channel)
Maximum State Data Rate (Quarter/Half/Full channel)
Maximum Record Length
Analog Mux
Probing Options P6810 General-purpose probe with Option 1P – supports
TLA6202 TLA6203 TLA6204
68 102 136
8 GHz (125 ps) with 16 Kb record length
2GHz/1GHz/500MHz
450 MHz / 450 MHz / 235 MHz (standard)
625MHz/800MHz/450MHz(withOption45)
900 Mb/s / 470 Mb/s / 235 Mb/s (standard)
1.25 Gb/s / 900 Mb/s / 450 Mb/s (with Option 45)
2 Mb (standard)
8MbwithOption1S
32 Mb with Option 2S
128 Mb with Option 3S
4 xed channels (standard)
Any signal (user selectable) may be routed to
4 output BNCs with Option AM
single-ended and differential signals
Mictor connections with Option 2P
P6960 D-Max probe with Option 3P
Characteristics
General
Characteristic Description
Number of Channels (All channels are acquired including clocks)
TLA6202
TLA6203
TLA6204
Channel grouping No limit to number of groups or number of
mp
Time Sta
Clocking/Acquisition Modes
Expansion Capability The TLA6000 Series can be used as either a
68 channels
102 channels (4 are clock and 2 are qualier channels)
136 channels (4 are clock and 4 are qualier channels)
channels per group (all channels can be reused in multiple groups)
51 bits a
Asynchronous/Synchronous 8 GHz MagniVu high-speed timing is available simultaneous with all modes
master or expansion mainframe in systems consisting of up to 8 TLA6000/TLA7000 instruments. A TL708EX Instrument Hub and Expander is required when connecting 3-8 instruments together using TekLink™ cables
(4 are clock channels)
t 125 ps resolution (3.25 days duration)
2 www.tektronix.com
Tektronix Logic Analyzers — TLA6000 Series
PC Characteristics
Characteristi
Operating System Microsoft®Windows®XP Professional and
Processor
Chipset Intel®965GME
Memory
Sound Line In, Line Out, and Mic Out connectors
RemovableHardDrive
Optical Drive Internal 4.7 GB DVD±R/RW
External Display Port Type
External Display Resolution
Network Port
USB 2.0 Port Seven (7); three (3) in front and four (4) in rear
c
Description
Multilingual User Interface Pack
2.2 GHz Intel Core 2 Duo T7500
1GBDDR2exp
3.5 in., 80 GB Serial ATA, 7200 RPM
One (1) DV connect
Up to 1600×1200 noninterlaced at 32-bit color, each for both primary and secondary displays
Two (2) 10/100/1000 LAN with RJ-45 connector
andable to 2 GB DDR memory
I-I (primary – digital and analog)
or and one (1) VGA connector
Integral Controls
Characteristic Description
Front-panel Display
Simultaneous Display Capability
Panel
Front
TouchScreen AvailablewithOption18
Size: 15 in. (38.1 cm) diagonal Type: Active-matrix color TFT LCD with backlight Resolution: 1024×768
Both the front-panel and one external display can be used simultaneously at 1024×768 resolution
General-purpose knob with dedicated hotkeys and knobs for horizontal and vertical scaling and scrolling
Integrated View (iView™) Capability
Characteristic Description
TLA Mainframe Conguration Requirements
er of Tektronix
Numb
illoscopes that can
Osc
onnected to a TLA
be C
tem
Sys
External Oscilloscopes Supported
TLA Connections USB, Trigger In, Trigger Out, Clock Out
Oscilloscope Connections
etup
S
Data Correlation After oscilloscope acquisition is complete, t he
Deskew The oscilloscope and TLA data is automatically
iView™ External Oscilloscope Cable Length
GPIB-iView (Opt. 1C) requires TLA Application Software 5.0 or greater
1
More than 100. For a complete listing of currently supported oscilloscopes, please visit our website http://www.tektronix.com/iview
GPIB, Trigger In, Trigger Out, Clock In (when available) for the GPIB-iView cable (Opt. 1C)
iView™ external oscilloscope wizard automates setup
data is automatically transferred to the TLA and time correlated with the TLA acquisition data
deskewed and time correlated when using the iView™ external oscilloscope cable
2m
Symbolic Support
Characteristi
Number of Symbols/Ranges
Object File Formats Supported
c
Description
Unlimited (limited only by amount of virtual memory available on TLA)
IEEE695, OMF 51, OMF 86, OMF 166, OMF 286, OMF 386, COFF, Elf/Dwarf 1 and 2, Elf/Stabs, TSF (If your software development tools do not generate output in one of the above formats, TSF, or the Tektronix symbol le, a generic ASCII le format is supported. The generic ASCII le format is documented in the TLA User Manual). If a format is not listed, please contact your local Tektronix representative
External Instrumentation Interfaces
Characteristic Description
System Trigger Output
System Trigger Input Forces a system trigger (triggers all modules)
External Signal Output Can be used to drive external circuitry from a
External Signal Input Can be used to provide an external signal to
Asserted whenever a system trigger occurs (TTL-compatible output, back-terminated into 50 Ω)
when asserted (adjustable threshold between
0.5 V and 1.5 V, edge sensitive, falling-edge latched)
module’s trigger mechanism (TTL-compatible output, back-terminated into 50 Ω)
arm or trigger any or all modules (adjustable threshold between 0.5 V and 1.5 V, level sensitive)
Power
Voltage Range/Frequency: 90-250 V AC at 45-66 Hz, 100-132 V AC at 360-440 Hz Input Current: 7 A maximum at 90 V AC (70 A surge) Power Consumption: 750 W maximum
Environmental
Characteristic Description
Temperature
Humidity
titude
Al
Safety UL3111-1, CSA1010.1, EN61010-1, IEC61010-1
Operating: +5 °C to +45 °C Nonoperating: –20 °C to +60 °C
20% to 80% Operating: 30 °C; 80% relative humidity (29 °C maximum wet-bulb temperature) Nonoperating: 8% to 80% (29 °C maximum wet-bulb temperature)
Operating: –1,000 ft. to 10,000 ft. (–305 meters to 3,050 meters)
Physical Characteristics
Dimensions
Height 295 11.6 Width 451 17.75 Depth 460 18.1
Weight kg lb.
Net 17.1 36.7 Shipping (Typical)
mm
30.1 66.7
in.
www.tektronix.com 3
Data Sheet
Input Characteristics (with P6800 or P6900 Series probes)
Characteristi
Capacitive Loading 0.5 pF clock/data (P6900 Series)
Threshold Selection Range
Threshold Selection Channel Granularity
Threshold Accuracy (including probe)
Input Voltage Range
Operating
Nondestructive ±15 V
Minimum Input Signal Swing
Input Signal Minimum Slew Rate
State Acquisition Characteristics (with P6800 or P6900 Ser ies probes)
Full Channel Half Channel Quarter Channel
235 MHz
450 MHz Optional 800 MHz / 800 Mb/s or
Note: When using SQUIRE adapters, the maximum clock rate / data rate is 300 MHz / 600 Mb/s.
Characteristic Description
State Record Length with Time Stamps
Setup-and-Hold Time Selection Range
Setup-and-Hold Window
All channels 625 ps typical
Single channel
Minimum Clock Pulse Width
Active Clock Edge Separation
Demux Channel Selection
c
Description
<0.7 pF clock/data (P6800 Series) (1.0 pF for P6810 in group conguration)
From–2.0Vto+4.5Vin5mVincrements Threshold presets include TTL (1.5 V), CMOS (1.65 V), ECL (–1.3 V), PECL (3.7 V), LVPECL (2.0 V), LVCMOS 1.5 V (0.75 V), LVCMOS 1.8 V (0.9 V), LVCMOS 2.5 V (1.25 V), LVCMOS 3.3 V (1.65 V), LVDS (0 V), and user dened
Separate selection for each of the clock/qualier channels and one per group of 16 data channels for each 34-channel probe
±(35 mV + 1%)
–2.5 V to 5.0 V
300 mV (single ended)
¯
V
MAX–VMIN
> 150 mV (differential)
200 mV/ns typical
450 MHz / 450 Mb/s or
450 MHz / 900 Mb/s
470 Mb/s (DDR)
625MHz/1.25Gb/s
900 Mb/s (DDR)
(Quarter/Half/Full channels) 8/4/2 Mb, 32/16/8 Mb, 128/64/32 Mb, 512/256/128 Mb per channel
From 16 ns before, to 8 ns after clock edge in 125 ps increments. Range may be shifted towards the setup region by 0 ns [+8, –8] ns, 4 ns [+12, –4] ns, or 8 ns [+16, 0] ns
500 ps typical
500 ps, 700 ps (P6810)
400 ps
Channels can be demultiplexed to other channels through user interface with 8-channel granularity
Timing Acquisition Characteristics (with P6800 or P6900 S eries probes)
Characteristic Description
MagniVu™ Timing 125 ps max, adjustments to 250 ps, 500 ps, 1 ns,
and2ns
MagniVu Timing Record Length
Deep Timing
16 Kb per channel, with adjustable trigger position
500ps/1ns/2nsto50ms Resolution (Quarter/Half/Full channels)
Deep Timing
4nsto50ms Resolution with Glitch Storage Enabled
Deep Timing Record Length
8/4/2 Mb, 32/16/8 Mb, 128/64/32 Mb,
512/256/128 Mb per channel (Quarter/Half/Full channels with time stamps and with or without transitional storage)
Deep Timing Record
Half of default main memory depth Length with Glitch Storage Enabled
Channel-to-Channel
300 ps typical Skew
Minimum Recognizable Pulse/Glitch Width
500 ps (P6960, P6964, P6980, P6982, P6860,
P6864, P6880), 750 ps (P6810) (Single channel)
Minimum Detectable
250 ps Setup/Hold Violation
Minimum Recognizable
ample period + channel-to-channel skew
S Multichannel Trigger Event
4 www.tektronix.com
Tektronix Logic Analyzers — TLA6000 Series
Analog Acquisition Characteristics (with P6800 or P6900 Ser ies probes)
xed
c
Description
2GHztypical
10X, ±1%
±50 mV, ±2% of signal amplitude
4
None, analog outputs are always active
Compatible with any supported Tektronix oscilloscope
Low loss, 10X, 36 in. Basic Analog Multiplexer functionality is offered standard on all TLA6000 models. This routes 4 xed channels to the iCapture Analog Output BNCs. The outputs cannot be switched to other logic analyzer channels. Option AM enables full analog multiplexer control and allows the routing of any 4 logic analyzer channels to the iCapture Analog Output BNCs
Characteristi
Bandwidth
Attenuation
Offset and Gain (Accuracy)
Channels Demultiple
Run/Stop Requirements
iCapture™ Analog Outputs
iCapture Analog Output BNC Cable
Trigger Characteristics
Characteristi
Independent Trigger States
Maximum Independent If/Then Clauses per State
Maximum Number o f Events per If/Then Clause
Maximum Number o f Actions per If/Then Clause
Maximum Number o f Trigger Events
Number of Word Recognizers
Number of Transition Recognizers
Number of Range Recognizers
Number of Counters/Timers
Trigger E vent Types
ger Action Types
Trig
Maximum Triggerable Data Rate
Trigger Sequence Rate DC to 500 MHz (2 ns)
Counter/Timer Range 51 bits each (>50 days at 2 ns)
CounterRate DCto500MHz(2ns)
Timer Clock Rate 500 MHz (2 ns)
Counter/Timer Latency
Range Recognizers
Setup-and-Hold Violation Recognizer SetupTimeRange
Setup-and-Hold Violation Recognizer Hold Time Range
Trigger Position Any data sample
MagniVu Trigger Position
Storage Control (Data qualication)
c
Description
16
16
8
8
18 (2 counters/timers plus any 16 other
resources)
16
16
4
2
Word, Group, Channel, Transition, Range,
Anything, Counter Value, Timer Value, Signal,
Glitch, Setup-and-Hold Violation, Snapshot
ger Module, Trigger All Modules, Trigger
Trig
, Trigger MagniVu, Store, Don’t Store, Store
Main
le, Increment Counter, Decrement Counter,
Samp
t Counter, Start Timer, Stop Timer, Reset
Rese
r, Snapshot Current Sample, Goto State,
Time
Clear Signal, Do Nothing
Set/
1250 Mb/s (4X clocking mode)
2ns
Double bounded (408 channel max). Can be as
wide as any group, must be grouped a ccording
to specied order of signicance
From 8 n s before to 7 ns after clock edge in
125 ps increments. This range may be shifted
towards the positive region by 0 ns, 4 ns, or 8 ns
From 7 n s before to 8 ns after clock edge in
125 ps increments. This range may be shifted
towards the positive region by 0 ns [+8, –8] ns,
4 ns [+12, –4] ns, or 8 ns [+16, 0] ns
MagniVu position can be set from 0% to 60%
centered around the MagniVu trigger
Global (conditional), by state (start/stop), block,
by trigger action, or transitional. Also force main
prell selection available
www.tektronix.com 5
Data Sheet
Ordering Information
TLA6202
68-channel Logic Analyzer module, 8 GHz timing, 235 MHz state, 2 Mb record length. Options for up to 128 Mb record length and/or up to 450 MHz state.
TLA6203
102-channel length. Opti
TLA6204
136-channel Logic Analyzer module, 8 GHz timing, 235 MHz state, 2 Mb record length. Options for up to 128 Mb record length and/or up to 450 MHz state.
All Include: Mini Keyboard (119-7275-xx), Optical Wheel Mouse (119-7054-xx), Front-panel cover (200-4939-xx), TLA Application Software CD (063-3881-xx), Certicate of Traceable Calibration.
Please specify probe, power, language, and service options when ordering.
Instrument Options
Option
1P
2P
3P 1S 2S 3S 45 Increase state speed to 450 MHz AM 18 Add touch screen 1C PO TL Add TekLink cable
Logic Analyzer module, 8 GHz timing, 235 MHz state, 2 Mb record
ons for up to 128 Mb record length and/or up to 450 MHz state.
Description
Add full complement of P6810 (General-purpose) probes
Add full complement of P6434 (Mictor) probes. Includes SQUIRE adapters
Add full complement of P6960 (D-Max) probes Increaseto8Mbrecordlength Increase to 32 Mb record length Increase to 128 Mb record length
Add full analog mux control
Add iView cable Add accessory pouch
Recommended Accessories
Accessory Description
LACART (2-shelf cart) K4000 (3-shelf cart)
016-1522-xx 020-2664-xx Rackmount Kit 650-4815-xx
Logic Analyzer Cart
Wheeled Transport Case
Additional Removable Hard Drive Assembly; No SW
Power Plug Options
Option
A0 North America 161-0104-00 A1 Universal Euro 161-0104-06 A2 United Kingdom 161-0104-07 A3 Australia 161-0104-14 A4 240 V, North America 161-0104-08 A5 A6 Japan 161-A005-00 A10 A11 India 161-0324-00 A99
Description
Switzerland
China
No power cord or AC adapter
Order Numbe
161-0167-00
161-0306-00
Language Options
Option Description
L0 English Manual
L5 Japanese Manual
L10 Russian Manual
L99 No Manual
r
6 www.tektronix.com
Tektronix Logic Analyzers — TLA6000 Series
Service Options
Option
Description
CA1 Provides a single calibration event or coverage for
the designated calibration interval, whichever comes rst
C3 Calibration Service, 3 Years C5 Calibration Service, 5 Years D1 D3 D5 R3 R5
Calibration Data Report Calibration Data Report, 3 Years (with Option C3) Calibration Data Report, 5 Years (with Option C5) Repair Service, 3 Years
Repair Service, 5 Years S1 On-site Service, 1 Year S3 On-site Service, 3 Years (with R or C options) R1PW R2PW R3DW
Repair Service Coverage, 1-year Post Warranty
Repair Service Coverage, 2-year Post Warranty
Repair Service Coverage, 3 Years (includes product
warranty period). 3-year period starts at time of
instrument purchase R5DW
Repair Service Coverage, 5 Years (includes product
warranty period). 5-year period starts at time of
instrument purchase
Upgrades
You can increase the state speed, memory depth, or add full analog multiplexer capability to existing TLA6000 models by orde ring the appropriate upgrade kit. Please refer to the TLA Family Upgrade Guide for further details.
Product(s) are manufactured in ISO registered facilities.
Product(s) complies with IEEE Standard 488.1-1987, RS-232-C, and with Tektronix Standard Codes and Formats.
www.tektronix.com 7
Data Sheet
Contact Tektronix:
ASEAN / Australa
Balkans, Israel, South Africa and other ISE Countries +41 52 675 3777
Central East Eu
Mexico, Central/South America & Caribbean (52) 56 04 50 90
* European toll-free number. If not accessible, call: +41 52 675 3777
rope, Ukraine, and the Baltics +41 52 675 3777
Central Europe & Greece +41 52 675 3777
Middle E ast,
Asia, and North Africa +41 52 675 3777
The Netherlands 00800 2255 4835*
People’s Rep
Republic of
United Kingdom & Ireland 00800 2255 4835*
sia (65) 6356 3900
Austria 00800 225 5 4835*
Belgium 00800 22
Brazil +55(11)37597600
Canada 1 800 833 9200
Denmark +4580881401
Finland +41526
France 00800 2255 4 835*
Germany 00800 2255 4835*
Hong Kong 400 8
India 000 800 650 1835
Italy 00800 225 5 4835*
Japan 81 (3) 67
Luxembourg +41526753777
ublic of China 400 820 5835
Poland +41 52 675 3777
Korea 001 800 8255 2835
Russia & CIS +7 (495) 7484900
South Africa +41526753777
Spain 00800
Sweden 008 00 2255 4 835*
Switzerland 00800 2255 4835*
Tai wa n 886 (
55 4835*
75 3777
20 5835
14 3010
Norway 800 16098
Portugal 80 08 12370
2255 4835*
2) 2722 9622
USA 1 800 833 9200
Updated 25 May 2010
www.tektronix.com
For Further Information. Tektronix maintains a comprehensive, constantly expanding collection of application notes, technical briefs and other resources to help engineers working on the cutting edge of technology. Please visit www.tektronix.com
t © Tektronix, Inc. All rights reserved. Tektronix products are covered by U.S. and foreign patents,
Copyrigh
d pending. Information in this publication supersedes that in all previously published material.
issued an
tion and price change privileges reserved. TEKTRONIX and TEK are registered trademarks of
Specica
x, Inc. All other trade names referenced are the service marks, trademarks, or registered trademarks
Tek t ro ni
espective companies.
of their r
07 Sep 2010 52W-25734-0