Tektronix TLA6000 DATASHEET

Tektronix Logic Analyzers
TLA6000 Series Data Sheet
Features & Benets
Comprehensive Set of Signal Integrity Tools that Allow You to Quickly Isolate, Identify, and Debug Complex Signal Integrity Issues
Glitch Trigger and Storage – Allows you to trigger on and highlight
al signal integrity problems. Not only can the TLA6000 Series
potenti trigger on the problem, but by highlighting suspected problems in red, you will be able to easily determine which signals you need to investigate further iCapture – Route the suspected signal to the analog output of the TLA6000 using the exclusive Tektronix iCapture feature. Th is
tes the need to double-probe with an oscilloscope probe,
elimina reducing time to debug iView – Time-correlated view of both logic analyzer and oscilloscope data to trace the SI p roblem across the digital and analog domain
Performance and Ease of Use to Debug, Validate, and Optimize Digital Systems
125 ps Resolution MagniVu™ Acquisition to Accurate ly See Signal Relationshi State Speed – Sample your fastest synchronous buses with clock rates up to 800 MHz and data rates up to 1.25 Gb/s 15 in. Display, with Optional Touch Screen to See More of Your Data and Navigate Efciently through Your Data 3 Models w ith 68/102/136 Channels and Up to 128 Mb Record Length offer Flexi Drag-and-Drop Triggering – Simply drag any one of eight different trigger types from a table onto the waveform and the TLA will automatically set up the trigger conditions. Eliminates errors, improves repeatability, and saves time Drag-and-Drop Measurements – Simply drag an icon from the measuremen a table of results. Saves time, removes complexity, and reduces measurement uncertainty
Analysis T
FPGA DDR A Broad Selection of Microprocessor and Bus Support MIPI CSI and DSI Debug
ps in Your System
ble Solutions to Fit Any Budget
t toolbar and drop it on your signal of interest and get
ools for Debugging and Validating Today’s Digital Systems
Applications
Hardware Validation and Debug
Digital
Monitoring, Measurement, and Optimization of Digital Hardware Performance
Embedded Software Integration, Debug, and Verication
Data Sheet
Efciently Debug and Validate Your Digital System at a Price You Will Like!
The affordable TLA6000 Series of logic analyzers offer the performance needed to debug, validate, and optimize the functionality of your digital system. The TLA6000 Series also provides a comprehensive set of signal integrity deb
ug tools that allow you quickly isolate, identify, and characterize elusive and hard-to-n d problems. Add a broad range of support for today’s applications, and you have the ideal tool to help you meet all of the debug challenges of today’s digital designs.
The TLA6000 Series allows you to effectively validate and d ebug the functionality of your digital designs:
Use the patented 8 GHz Mag niVu technology to accurately measure timing relationships. The single, integrated acquisition architecture of the TLA6000 Series eliminates the timing skew problems inherent in other logic analyzer architectures
Capture on buses with clock rates up to 800 MHz and data rates up to
1.25 Gb/s
Buy the capability you need now and upgrade as your measurement needs grow
Quickly isolate events through a simple and intuitive drag-and-drop trigger setup
Easily summarize your design’s performance with sophisticated drag-and-drop measurements such as frequency, period, pulse width, duty cycle, and edge count
View data in a variety of time-correlated formats including waveform, listing, graph, disassembly, source code, or compare
Find Tough Signal Integrity Problems
Today’s logic analyzers not only need to help troubleshoot functional issues in your design, but also need to help nd signal integrity problems caused by crosst help debug these problems, the TLA6000 Series includes a comprehensive suite of signal debug tools.
These tools allow you to:
alk, termination mismatches, ground bounce, and other issu es. To
Use glitch trigger to monitor selected signals in your design and trigger when a signal integrity problem is found on any one of these signals
Automatically tag any found signal integrity problems, allowing you to quickly identify the signals of interest
Gain more insight into the problem using the exclusive iCapture functionality to view both digital and analog data through a single probe
Use iView to see time-correlated digital and analog displays of you r data, letting you track the signal integrity problem across both analog and digital domains
TLA6000 Selection Guide
Characteristic
Channels High-speed Timing Maximum Timing
Sample Rate (Quarter/Half/Full channel)
Maximum State Clock Rate (Quarter/Half/Full channel)
Maximum State Data Rate (Quarter/Half/Full channel)
Maximum Record Length
Analog Mux
Probing Options P6810 General-purpose probe with Option 1P – supports
TLA6202 TLA6203 TLA6204
68 102 136
8 GHz (125 ps) with 16 Kb record length
2GHz/1GHz/500MHz
450 MHz / 450 MHz / 235 MHz (standard)
625MHz/800MHz/450MHz(withOption45)
900 Mb/s / 470 Mb/s / 235 Mb/s (standard)
1.25 Gb/s / 900 Mb/s / 450 Mb/s (with Option 45)
2 Mb (standard)
8MbwithOption1S
32 Mb with Option 2S
128 Mb with Option 3S
4 xed channels (standard)
Any signal (user selectable) may be routed to
4 output BNCs with Option AM
single-ended and differential signals
Mictor connections with Option 2P
P6960 D-Max probe with Option 3P
Characteristics
General
Characteristic Description
Number of Channels (All channels are acquired including clocks)
TLA6202
TLA6203
TLA6204
Channel grouping No limit to number of groups or number of
mp
Time Sta
Clocking/Acquisition Modes
Expansion Capability The TLA6000 Series can be used as either a
68 channels
102 channels (4 are clock and 2 are qualier channels)
136 channels (4 are clock and 4 are qualier channels)
channels per group (all channels can be reused in multiple groups)
51 bits a
Asynchronous/Synchronous 8 GHz MagniVu high-speed timing is available simultaneous with all modes
master or expansion mainframe in systems consisting of up to 8 TLA6000/TLA7000 instruments. A TL708EX Instrument Hub and Expander is required when connecting 3-8 instruments together using TekLink™ cables
(4 are clock channels)
t 125 ps resolution (3.25 days duration)
2 www.tektronix.com
Tektronix Logic Analyzers — TLA6000 Series
PC Characteristics
Characteristi
Operating System Microsoft®Windows®XP Professional and
Processor
Chipset Intel®965GME
Memory
Sound Line In, Line Out, and Mic Out connectors
RemovableHardDrive
Optical Drive Internal 4.7 GB DVD±R/RW
External Display Port Type
External Display Resolution
Network Port
USB 2.0 Port Seven (7); three (3) in front and four (4) in rear
c
Description
Multilingual User Interface Pack
2.2 GHz Intel Core 2 Duo T7500
1GBDDR2exp
3.5 in., 80 GB Serial ATA, 7200 RPM
One (1) DV connect
Up to 1600×1200 noninterlaced at 32-bit color, each for both primary and secondary displays
Two (2) 10/100/1000 LAN with RJ-45 connector
andable to 2 GB DDR memory
I-I (primary – digital and analog)
or and one (1) VGA connector
Integral Controls
Characteristic Description
Front-panel Display
Simultaneous Display Capability
Panel
Front
TouchScreen AvailablewithOption18
Size: 15 in. (38.1 cm) diagonal Type: Active-matrix color TFT LCD with backlight Resolution: 1024×768
Both the front-panel and one external display can be used simultaneously at 1024×768 resolution
General-purpose knob with dedicated hotkeys and knobs for horizontal and vertical scaling and scrolling
Integrated View (iView™) Capability
Characteristic Description
TLA Mainframe Conguration Requirements
er of Tektronix
Numb
illoscopes that can
Osc
onnected to a TLA
be C
tem
Sys
External Oscilloscopes Supported
TLA Connections USB, Trigger In, Trigger Out, Clock Out
Oscilloscope Connections
etup
S
Data Correlation After oscilloscope acquisition is complete, t he
Deskew The oscilloscope and TLA data is automatically
iView™ External Oscilloscope Cable Length
GPIB-iView (Opt. 1C) requires TLA Application Software 5.0 or greater
1
More than 100. For a complete listing of currently supported oscilloscopes, please visit our website http://www.tektronix.com/iview
GPIB, Trigger In, Trigger Out, Clock In (when available) for the GPIB-iView cable (Opt. 1C)
iView™ external oscilloscope wizard automates setup
data is automatically transferred to the TLA and time correlated with the TLA acquisition data
deskewed and time correlated when using the iView™ external oscilloscope cable
2m
Symbolic Support
Characteristi
Number of Symbols/Ranges
Object File Formats Supported
c
Description
Unlimited (limited only by amount of virtual memory available on TLA)
IEEE695, OMF 51, OMF 86, OMF 166, OMF 286, OMF 386, COFF, Elf/Dwarf 1 and 2, Elf/Stabs, TSF (If your software development tools do not generate output in one of the above formats, TSF, or the Tektronix symbol le, a generic ASCII le format is supported. The generic ASCII le format is documented in the TLA User Manual). If a format is not listed, please contact your local Tektronix representative
External Instrumentation Interfaces
Characteristic Description
System Trigger Output
System Trigger Input Forces a system trigger (triggers all modules)
External Signal Output Can be used to drive external circuitry from a
External Signal Input Can be used to provide an external signal to
Asserted whenever a system trigger occurs (TTL-compatible output, back-terminated into 50 Ω)
when asserted (adjustable threshold between
0.5 V and 1.5 V, edge sensitive, falling-edge latched)
module’s trigger mechanism (TTL-compatible output, back-terminated into 50 Ω)
arm or trigger any or all modules (adjustable threshold between 0.5 V and 1.5 V, level sensitive)
Power
Voltage Range/Frequency: 90-250 V AC at 45-66 Hz, 100-132 V AC at 360-440 Hz Input Current: 7 A maximum at 90 V AC (70 A surge) Power Consumption: 750 W maximum
Environmental
Characteristic Description
Temperature
Humidity
titude
Al
Safety UL3111-1, CSA1010.1, EN61010-1, IEC61010-1
Operating: +5 °C to +45 °C Nonoperating: –20 °C to +60 °C
20% to 80% Operating: 30 °C; 80% relative humidity (29 °C maximum wet-bulb temperature) Nonoperating: 8% to 80% (29 °C maximum wet-bulb temperature)
Operating: –1,000 ft. to 10,000 ft. (–305 meters to 3,050 meters)
Physical Characteristics
Dimensions
Height 295 11.6 Width 451 17.75 Depth 460 18.1
Weight kg lb.
Net 17.1 36.7 Shipping (Typical)
mm
30.1 66.7
in.
www.tektronix.com 3
Loading...
+ 5 hidden pages