Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supersedes that in all previously published
material. Specifications and price change privileges reserved.
TEKTRONIX and TEK are registered trademarks of Tektronix, Inc.
Contacting Tektronix
Tektronix, Inc.
14150 SW Karl Braun Drive
P.O. Box 500
Beaverton, OR 97077
USA
For product information, sales, service, and technical support:
In North America, call 1-800-833-9200.
Worl dwi de, v isit www.tektronix.com to find contacts in your area.
Table of Contents
General safety summary ...........................................................................................................................................ii
Service safety summary.......................... .................................. ................................ ................................................v
Media and data export devices ...............................................................................................................................7
Disassemble the instrument......................................................................................................................... .........14
Reassemble the instrument ........................... ................................ .................................. .....................................15
Tektronix BERTScope BSA Series Declassification and Security Instructionsi
General safety summary
General safety summary
Review the following safety precautions to avoid injury and prevent damage to this product or any products connected to it.
To avoid potential hazards, use this product only as specified.
Only qualified personnel should perform service procedures.
While using this product, you may need to access other parts of a larger system. Read the safety sections of the other
component manuals for warnings and cautions related to operating the system.
To avoid fire or personal
injury
Use proper power cord.
Connect and disconnect properly.
source.
Ground the product.
the grounding conductor must be connected to ea
the product, ensure that the product is properly grounded.
Observe all terminal ratings.
product manual for further ratings information before making connections to the product.
The inputs are not rated for connection to mains or Category II, III, or IV circuits.
Do not apply a potential to any terminal, including the common terminal, that exceeds the maximum rating of that terminal.
Power disconnect.
must remain accessible to the user at all times.
Do not operate without covers.
Do not operate with suspected failures.
service personnel.
Use only the power cord specified for this product and certified for the country of use.
Do not connect or disconnect probes or test leads while they are connected to a voltage
This product is grounded through the grounding conductor of the power cord. To avoid electric shock,
rth ground. Before making connections to the input or output terminals of
To avoid fire or shock hazard, observe all ratings and markings on the product. Consult the
The power cord disconnects the product from the power source. Do not block the power cord; it
Do not operate this product with covers or panels removed.
If you suspect that there is damage to this product, have it inspected by qualified
iiTektronix BERTScope BSA Series Declassification and Security Instructions
General safety summary
Terms in this manual
Avoid exposed circuitry.
Wear eye protection.
Do not operate in wet/damp conditions.
Do not operate in an explosive atmosphere.
Keep product surfaces clean and dry.
Provide proper ventilation.
proper ventilation.
These terms may appear in this manual:
WAR NI NG .
CAUTION.
Warning statements identify conditions or practices that could result in injury or loss of life.
Caution statements identify conditions or practices that could result in damage to this product or other property.
Do not touch exposed connections and components when power is present.
Wear eye protection if exposure to high-intensity rays or laser radiation exists.
Refer to the manual's installation instructions for details on installing the product so it has
Tektronix BERTScope BSA Series Declassification and Security Instructionsiii
General safety summary
Symbols and terms on the
product
These terms may appear on the product:
DANGER indicates an injury hazard immediately accessible as you read the marking.
WARNING indicates an injury hazard not immediately accessible as you read the marking.
CAUTION indicates a hazard to property including the product.
The following symbol(s) may appear on the product:
ivTektronix BERTScope BSA Series Declassification and Security Instructions
Service safety summary
Only qualified personnel should perform service procedures. Read this Service Safety Summary and the General Safety
Summary before performing any service procedures.
Do not service alone.
rendering first aid and resuscitation is present.
Disconnect power.
mains power.
Use care when servicing with power on.
remove battery (if applicable), and disconnect test leads before removing protective panels, soldering, or replacing
components.
To avoid electric shock, do not touch exposed connections.
Do not perform internal service or adjustments of this product unless another person capable of
To avoid electric shock, switch off the instrument power, then disconnect the power c ord from the
Dangerous voltages or currents may exist in this product. Disconnect power,
Tektronix BERTScope BSA Series Declassification and Security Instructionsv
Preface
Preface
This document helps customers with data security concerns to sanitize or remove memory devices from the Tektronix
BERTScope BSA Series Bit Error Rate Analyzers.
These products have data storage (memory) devices and data output devices (USB ports). These instructions tell how to
clear or sanitize the memory devices and disable the data output devices. The instructions also tell how to declassify an
instrument that is not functioning.
Reference
Products
Terms
The procedures in this document are written to meet the requirements specified in:
NISPOM, DoD 5220.22–M, Chapter 8
ISFO Process Manual for Certification & Accreditation of Classified Systems under NISPOM
The following Tektronix products are covered by this document:
BSA85C
BSA125C
BSA175C
BSA260C
BSA286C
The following terms may be used in this document:
Clear.
deny access to previously stored information by standard means of access.
Erase.
This removes data on media/memory before reusing it in a secured area. All reusable memory is cleared to
This is equivalent to clear.
viTektronix BERTScope BSA Series Declassification and Security Instructions
Preface
Instrument declassification.
A term that refers to procedures that must be undertaken before an instrument can be
removed from a secure environment. Declassification procedures include memory sanitization and memory removal,
and sometimes both.
Media storage/data export device.
Any of several devices that can be used to store or export data from the
instrument, such as a USB port.
Nonvolatile memory.
Power off.
Some instruments have a “Standby” mode, in which power is still supplied to the instrument. For the
Data is retained when the instrument is p owered off.
purpose of clearing data, putting the instrument in Standby mode does not qualify as powering off. For these products,
you will need to either press a rear-panel OFF switch or remove the power source from the instrument.
Remove.
This is a physical means to clear the data by removing the memory device from the instrument. Instructions
are available in the product Service Manual.
Sanitize.
This eradicates the data from media/memory so that the data cannot be recovered by other means or
technology. This is typically used when the device will be moved (temporarily or permanently) from a secured
area to a non-secured area.
Scrub.
User accessible.
User-modifiable.
This is equivalent to sanitize.
User is able to directly retrieve the memory device contents.
The u ser can write to the memory device during normal instrument operation, using the instrument
interface or remote control.
User-modifiable.
The u ser can write to the memory device during normal instrument operation, using the instrument
interface or remote control.
Volatile memory.
Data is lost when the instrument is powered off.
Tektronix BERTScope BSA Series Declassification and Security Instructionsvii