Tektronix TBS2104, TBS2102, TBS2074, TBS2072 User Manual

x
TBS2000 Series Oscilloscopes
ZZZ
User Manual
*P077114702*
077-1147-02
xx
TBS2000 Series Oscilloscopes
ZZZ
User Manual
Click the following link to protect your product.
www.tek.com/register
www.tek.com
077-1147-02
Copyright © Tektronix. All rights reserved. Licensed software products are owned by Tektronix or its subsidiaries or suppliers, and are protected by na
tional copyright laws and international treaty provisions.
Tektronix pro previously published material. Specications and price change privileges reserved.
TEKTRONIX and TEK are registered trademarks of Tektronix, Inc.
TekVPI is a registered trademark of Tektronix, Inc.
TekSecure and TekSmartLab are trademarks of Tektronix, Inc.
ducts are covered by U.S. and foreign patents, issued and pending. Information in this publication supersedes that in all
Contacting Tektronix
Tektronix, Inc. 14150 SW Karl Braun Drive P.O. Box 500 Beaverton, OR 97077 USA
For product i nformation, sales, service, and technical support:
In North America, call 1-800-833-9200. Worldwide, visit www.tek.com to nd contacts in your area.
TBS2000 Series Oscilloscopes
Warranty
Tektronix warrants that the product will be free from defects in materials and workmanship for a period of ve (5) years from the date of original purchase from an authorized Tektronix distributor. If the product proves defective during this warranty period, Tektronix, at its option, either will repair the defective product without charge for parts and labor, or will provide a replacement in exchange for the defective product. Batteries are excluded from this warranty. Parts, modules and replacement products used by Tektronix for warranty work may be new or reconditioned to like new performance. All replaced parts, modules and products become the property of Tektronix.
In order to obtain service under this warranty, Customer must notify Tektronix of the defect before the expiration of the warranty period and make suitable arrangements for the performance of s ervice. C ustomer shall be responsible for packaging and shipping the defective product to the service center designated by Tektronix, shipping charges prepaid, and with a copy of customer proof of purchase. Tektronix shall pay for the return of the product to Customer if the shipment is to a location within the country in which the Tektronix service center is located. Customer shall be responsible for paying all shipping charges, duties, taxes, and any other charges for products returned to any other locations.
This warranty shall not apply to any defect, failure or damage caused by improper use or improper or inadequate maintenance and care. Tektronix shall not be obligated to furnish service under this warranty a) to repair damage resulting from attempts by personnel other than Tektronix representatives to install, repair or service the product; b) to repair damage resulting from improper use or connection to incompatible equipment; c) to repair any damage or malfunction caused by the use of non-Tektronix supplies; or d) to service a product that has been modied or integrated with other products when the effect of such modication or integration increases the time or difculty of servicing the product.
THIS WARRANTY IS GIVEN BY TEKTR ON IX WITH RES PEC T TO THE PRODUCT IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED. TEKTRONIX AND ITS VENDORS DISCLAIM ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. TEKTRONIX' RESPONSIBILITY TO REPAIR OR REPLACE DEFECTIVE PRODUCTS IS THE SOLE AND EXCLUSIVE REMEDY PROVIDED TO THE CUSTOMER FOR BREACH OF THIS WARRANTY. T EKT RONIX AND ITS VENDORS WILL NOT BE LIABLE FOR ANY INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES IRRESPECTIVE OF WHETHER TEKTRONIX OR THE VENDOR HAS ADVANCE NOTICE OF THE POSSIBILITY OF SUCH DAMAGES.
TPP0100 Probe
Warranty
Tektronix warrants that this product will be free from defects in materials and workmanship for a period of one (1) year from the date of shipment. If any such product proves defective during this warranty period, Tektronix, at its option, either will repair the defective product without charge for parts and labor, or will provide a replacement in exchange for the defective product. Parts, modules and replacement products used by Tektronix for warranty work may be new or reconditioned to like new performance. All replaced parts, modules and products become the property of Tektronix.
In order to obtain service under this warranty, Customer must notify Tektronix of the defect before the expiration of the warranty period and make suitable arrangements for the performance of service. Customer shall be responsible for packaging and shipping the defective product to the service center designated by Tektronix, with shipping charges prepaid. Tektronix shall pay for the return of the product to Customer if the shipment is to a location within the country in which the Tektronix service center is located. Customer shall be responsible for paying all shipping charges, duties, taxes, and any other charges for products returned to any other locations.
This warranty shall not apply to any defect, failure or damage caused by improper use or improper or inadequate maintenance and care. Tektronix shall not be obligated to furnish service under this warranty a) to repair damage resulting from attempts by personnel other than Tektronix r epresentatives to install, repair or service the product; b) to repair damage resulting from improper use or connection to incompatible equipment; c) to repair any damage or malfunction caused by the use of non-Tektronix supplies; or d) to service a product that has been modied or integrated with other products when the effect of such modication or integration increases the time or difculty of servicing the product.
THIS WARRANTY IS GIVEN BY TEKTRONIX WITH RESPECT TO THE PRODUCT IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED. TEKTRONIX AND ITS VENDORS DISCLAIM ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. TEKTRONIX' RESPONSIBILITY TO REPAIR OR REPLACE DEFECTIVE PRODUCTS IS THE SOLE AND EXCLUSIVE REMEDY PROVIDED TO THE CUSTOMER FOR BREACH OF THIS WARRANTY. T EKTRONIX AND ITS VENDO RS WILL NOT BE LIABLE FOR ANY INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES IRRESPECTIVE OF WHETHER TEKTRONIX OR THE VENDOR HAS ADVANCE NOTICE OF THE POSSIBILITY OF SUCH DAMAGES.
Table of Contents
Important safety information .......................................................................................................... v
Preface ................................................................................................................................. ix
Key features...................................................................................................................... ix
Terms in this manual ... . ... . ... . . . ... . ... . . . ... . ... . . . ... . ... . ... . .. ... . ... . . . ... . ... . ... . .. ... . ... . . . ... . ... . ... . .. ... . ... . . . ... x
Symbols and terms on the product . ... . ... . . . ... . ... . .. ... . ... . . . ... . ... . . . ... . ... . .. ... . ... . . . ... . ... . . . ... . ... . .. ... . ... . . . ... x
Conventions used in this manual ... . . . ... . ... . ... . . . ... . ... . ... . ... . .. ... . ... . ... . ... . .. ... . ... . ... . ... . .. ... . ... . ... . ... . .. ... . xi
Installation.............................................................................................................................. 1
Before installation ................................................................................................................ 1
Operating requirements . . . . ... . ... . .. ... . ... . . . ... . ... . . . ... . ... . .. ... . ... . . . ... . ... . . . ... . ... . .. ... . ... . . . ... . ... . . . ... . ... . .. ....... 4
Environment requirements. . .. ... . . . ... . ... . . . ... . ... . .. ... . . . ... . ... . . . ... . . . ... . ... . . . ... . ... . .. ... . . . ... . ... . . . ... . ... . . . ... . . 4
Power requirements.. . ... . . . ... . ... . .. ... . ... . . . ... . . . ... . ... . . . ... . ... . .. ... . ... . . . ... . ... . . . ... . . . ... . ... . .. ... . ... . . . ... . ... . . 4
Getting acquainted with the oscilloscope .. . .. ... . ... . ... . . . ... . ... . . . ... . ... . ... . ... . .. ... . ... . ... . ... . . . ... . ... . ... . ... . .. ... . ... . .. 5
Powering on and off the oscilloscope ........................................................................................... 5
Changing the user interface language . . ... . .. ... . ... . . . ... . ... . . . ... . ... . .. ... . ... . . . ... . ... . . . ... . ... . .. ... . ... . . . ... . ... . . . .. 6
Changing the date and time . . .. ... . ... . . . ... . ... . .. ... . ... . .. ... . ... . . . ... . . . ... . ... . . . ... . ... . .. ... . . . ... . ... . . . ... . . . ... . ... . . 9
Connecting probes to the oscilloscope . .. ... . ... . ... . .. ... . ... . ... . ... . .. ... . ... . ... . ... . .. ... . ... . ... . . . ... . ... . . . ... . ... . ... . 11
Reducing electrostatic damage while taking measuremens . . . ... . . . ... . . . ... . . . ... . . . ... . . . ... . . . ... . . . ... . . . ... . . . ... . 11
Doing a functional check.. . .. ... . ... . ... . . . ... . ... . . . ... . ... . ... . ... . .. ... . ... . ... . ... . .. ... . ... . ... . . . ... . ... . . . ... . ... . ... . ... 12
What isAutoset?........................................................................................................... 14
Compensating a passive voltage probe . . . ... . ... . . . ... . ... . . . ... . ... . ... . .. ... . ... . . . ... . ... . ... . .. ... . ... . . . ... . ... . ... . .. ... 15
Signal path compensation (SPC). . . ... . ... . ... . .. ... . . . ... . ... . . . ... . ... . . . ... . ... . .. ... . ... . . . ... . ... . . . ... . ... . .. ... . ... . . . .. 18
Getting on-screen help for settings: Help Everywhere ........................................................................ 19
The Scope Intro function........................................................................................................ 21
Sampling oscilloscope concepts ..................................................................................................... 22
Sampling andacquisition concepts ............................................................................................ 22
Trigger concepts .. . ... . ... . .. ... . ... . ... . ... . .. ... . ... . ... . . . ... . ... . . . ... . ... . ... . ... . .. ... . ... . ... . ... . .. ... . ... . ... . . . ... . ... 24
Trigger slope and level concepts. . ... . . . ... . ... . . . ... . ... . ... . . . ... . ... . .. ... . ... . ... . . . ... . ... . . . ... . ... . . . ... . ... . ... . .. 25
Setting channel input parameters. . .. ... . . . ... . ... . ... . . . ... . ... . . . ... . ... . ... . . . ... . ... . .. ... . ... . ... . . . ... . ... . . . ... . ... . ... . . . .... 28
Setting input signal coupling .. . . . ... . ... . ... . .. ... . ... . ... . . . ... . ... . . . ... . ... . ... . . . ... . ... . . . ... . ... . ... . . . ... . ... . . . ... . ... . . 28
Inverting the input signal .. . . . ... . ... . ... . . . ... . ... . . . ... . ... . ... . . . ... . ... . .. ... . ... . ... . . . ... . ... . . . ... . ... . ... . . . ... . ... . .. ... 28
ing the oscilloscope bandwidth. . ... . ... . .. ... . ... . ... . . . ... . ... . . . ... . ... . ... . ... . .. ... . ... . ... . ... . .. ... . ... . ... . . . ... . ... 29
Sett
Setting the probe type (voltage orcurrent)..................................................................................... 29
Setting the probe attenuation factor .. . .. ... . ... . ... . ... . .. ... . ... . ... . . . ... . ... . . . ... . ... . ... . ... . .. ... . ... . ... . ... . .. ... . ... . . 30
Quickly setting the probe attenuation to 1X or 10X. . . . ... . ... . ... . ... . .. ... . ... . ... . ... . .. ... . ... . ... . . . ... . ... . . . ... . ... . ... . 30
Setting the Measure Current mode for voltage probes ... . . . ... . ... . ... . . . ... . ... . .. ... . ... . . . ... . ... . . . ... . ... . . . ... . ... . . . .. 31
Setting the input signal vertical offset . ... . ... . . . ... . ... . .. ... . ... . ... . . . ... . ... . .. ... . ... . ... . . . ... . ... . .. ... . ... . ... . . . ... . ... 31
Setting the waveform vertical position.......................................................................................... 32
The difference between vertical position and vertical offset ............................................................. 32
Setting channel deskew. .. ... . ... . ... . . . ... . ... . . . ... . ... . ... . . . ... . ... . . . ... . ... . ... . . . ... . ... . . . ... . ... . ... . . . ... . ... . . . ... . .. 33
Trigger setup . ... . . . ... . ... . .. ... . ... . . . ... . ... . . . ... . . . ... . ... . .. ... . ... . . . ... . ... . . . ... . ... . .. ... . . . ... . ... . . . ... . ... . . . ... . ......... 34
Triggering on a waveform edge .. . ... . ... . ... . . . ... . ... . . . ... . ... . ... . ... . . . ... . ... . ... . ... . .. ... . ... . ... . ... . .. ... . ... . ... . ... 34
Triggering on a speciedpulse width .......................................................................................... 35
Table of Content
s
TBS2000 Series User Manual i
Table of Content
Acquisition setup...................................................................................................................... 38
Waveform display settings ........................................................................................................... 44
Analyzing a waveform . . .. ... . ... . . . ... . ... . ... . .. ... . ... . ... . . . ... . ... . . . ... . ... . ... . . . ... . ... . . . ... . ... . ... . . . ... . ... . . . ... . ... . .... 47
Saving data ........................................................................................................................... 63
s
Triggering on a runt pulse....................................................................................................... 36
Setting the trigger mode .. . .. ... . ... . . . ... . ... . ... . . . ... . ... . ... . . . ... . ... . . . ... . ... . ... . ... . .. ... . ... . ... . ... . .. ... . ... . ... . . . . 37
Using Autoset ................................................................................................................... 38
Autoset tips ................................................................................................................ 38
How to disable Autoset in the oscilloscope............................................................................... 38
How to change the Autoset password .. . . . ... . ... . .. ... . . . ... . ... . .. ... . ... . . . ... . ... . .. ... . . . ... . . . ... . ... . . . ... . . . ... . . 39
Starting and stopping an acquisition . ... . ... . ... . . . ... . ... . . . ... . ... . ... . . . ... . ... . . . ... . ... . ... . . . ... . ... . . . ... . ... . ... . . . ... . 40
Setting the acquisition mode.................................................................................................... 40
Setting the acquisition trigger delay time. . . . . . . . . . . . ... . .. .. . . . . ... . .. .. . . . . ... . .. .. . . . . ... . . . . . . ... . .. .. . . . . ... . .. .. . . . . ... . .. 41
Setting the record length. ... . ... . . . ... . ... . ... . . . ... . ... . . . ... . ... . ... . . . ... . ... . . . ... . ... . ... . . . ... . ... . . . ... . ... . ... . . . ... . ... 42
Using the roll display mode ..................................................................................................... 43
Setting the oscilloscope to factory default values (Default Setup) ............................................................ 43
Displaying and removing a waveform .......................................................................................... 44
Setting the waveform persistence .............................................................................................. 44
The XY display mode ........................................................................................................... 45
Setting the backlight intensity................................................................................................... 46
Taking automatic measurements............................................................................................... 47
Automatic measurements tip.............................................................................................. 48
Taking a measurements snapshot. . .. ... . . . ... . ... . . . ... . ... . ... . .. ... . . . ... . ... . . . ... . ... . ... . .. ... . . . ... . ... . . . ... . ... . ... . .. 48
Snapshot measurement tip. .. ... . .. ... . ... . . . ... . . . ... . ... . . . ... . . . ... . ... . .. ... . . . ... . ... . . . ... . . . ... . ... . . . ... . . . ... . ... 48
Automatic measurement descriptions.......................................................................................... 49
Frequency measurement descriptions. ... . ... . . . ... . . . ... . ... . .. ... . ... . . . ... . ... . . . ... . ... . .. ... . . . ... . ... . . . ... . ... . . . . 49
Time measurement descriptions.......................................................................................... 49
Amplitude measurement descriptions .................................................................................... 50
Area measurement descriptions .......................................................................................... 52
Taking a measurement on just a part of the waveform (Gating) .............................................................. 52
Using cursors to take manual measurements . . ... . . . ... . ... . .. ... . . . ... . ... . ... . . . ... . ... . .. ... . . . ... . ... . ... . . . ... . ... . .. ... 53
Creating math waveforms ...................................................................................................... 55
Math waveform tips........................................................................................................ 56
Using FFT to see signal frequency information ... . ... . ... . .. ... . ... . . . ... . ... . ... . .. ... . ... . . . ... . ... . ... . .. ... . ... . . . ... . ... . 56
FFT tips .................................................................................................................... 58
About FFT windows . .. ... . . . ... . . . ... . ... . .. ... . . . ... . . . ... . . . ... . ... . .. ... . ... . .. ... . ... . .. ... . . . ... . . . ... . . . ... . ... . .. .. 59
FFT and display waveform aliasing....................................................................................... 60
Displaying reference waveforms ............................................................................................... 61
Reference waveform tips.................................................................................................. 61
How to view long record length waveforms (Zoom) .. . ... . ... . . . ... . ... . . . ... . ... . .. ... . ... . . . ... . ... . . . ... . ... . .. ... . ... . . . .. 62
Saving screen images to a le.................................................................................................. 63
About saved image le formats ........................................................................................... 64
Saving waveform data .......................................................................................................... 64
About waveform data les................................................................................................. 65
Saving oscilloscope setup information ......................................................................................... 66
ii TBS2000 Series User Manual
Table of Content
Saving les to USB with the Save File button.................................................................................. 67
Recalling data......................................................................................................................... 68
Recalling oscilloscope setup information....................................................................................... 68
Recalling waveform data........................................................................................................ 69
Using the USB File Utility functions.................................................................................................. 70
Overview of the File Utility pane . . . ... . ... . ... . ... . . . ... . ... . ... . ... . . . ... . ... . ... . ... . ... . ... . . . ... . ... . ... . ... . ... . .. ... . ... . . 70
Changing the default le save location on the USB drive..................................................................... 72
Default save folder location rules ......................................................................................... 72
Creating a new folder on the USB drive........................................................................................ 73
Folder creation tip ......................................................................................................... 73
Deleting les orfolders from the USB drive.................................................................................... 73
Renaming les orfolders on the USB drive ................................................................................... 74
File, folder renaming tip .. . ... . ... . ... . . . ... . ... . .. ... . ... . ... . . . ... . ... . . . ... . ... . ... . . . ... . ... . .. ... . ... . ... . . . ... . ... . . . 74
Formatting the USB drive....................................................................................................... 75
About automatically generated le names ..................................................................................... 75
Image, setting, and waveform le tips .................................................................................... 75
Erasing data from oscilloscope memory (TekSecure)............................................................................... 76
Setting or viewing USB Device port parameters .................................................................................... 77
Selecting which device is attached to the USB Device port................................................................... 77
Disabling the USB Device port ................................................................................................. 78
Viewing theUSBTMC information.............................................................................................. 78
Setting up the LAN network ..........................................................................................................79
Viewing the IP address - Ethernet.. . ... . . . ... . ... . .. ... . ... . ... . . . ... . ... . .. ... . ... . ... . . . ... . ... . .. ... . ... . ... . . . ... . ... . .. ... 79
Setting the IP address (DHCP network)- Ethernet. . . ... . ... . . . ... . ... . .. ... . ... . . . ... . ... . . . ... . ... . .. ... . ... . . . ... . ... . . . ... . 80
Setting the IP address (nonDHCP network)- Ethernet .. . ... . .. ... . ... . . . ... . ... . ... . .. ... . ... . . . ... . ... . ... . .. ... . ... . . . ... . . 80
Turning Ethernet DHCP on oroff............................................................................................... 81
Setting up the Wi-Fi network ......................................................................................................... 82
Turning Wi-Fi on or off .......................................................................................................... 82
Viewing Wi-Fi settings .......................................................................................................... 83
Viewing andselecting available Wi-Fi networks ............................................................................... 83
Setting the IP address (DHCP network) in Wi-Fi . . . ... . ... . . . ... . . . ... . . . ... . ... . . . ... . . . ... . ... . .. ... . . . ... . . . ... . ... . .. ... . . 84
Setting the IP address (nonDHCP network) in Wi-Fi . . ... . ... . . . ... . . . ... . ... . . . ... . . . ... . ... . .. ... . . . ... . ... . . . ... . . . ... . ... . 85
Turning DHCP on or off (Wi-Fi)................................................................................................. 86
Connecting your oscilloscope to a computer ... . ... . . . ... . ... . . . ... . ... . . . ... . ... . .. ... . ... . . . ... . ... . . . ... . ... . .. ... . ... . . . ... . ... . 87
Using a socket server........................................................................................................... 88
Remotely controlling the oscilloscope from a Web browser (LXI) .................................................................. 89
Installing new rmware on the oscilloscope ......................................................................................... 90
Running diagnostic tests .. . ... . ... . .. ... . ... . ... . . . ... . ... . . . ... . ... . ... . . . ... . ... . . . ... . ... . ... . . . ... . ... . . . ... . ... . ... . . . ... . ...... 91
Courseware on-instrument education and training. .. ... . ... . .. ... . ... . . . ... . ... . ... . .. ... . ... . . . ... . ... . ... . .. ... . ... . . . ... . ... . ... 92
Loading a courseware le from a USB drive................................................................................... 93
Running Courseware lab exercises ............................................................................................ 94
Saving Courseware lab results ................................................................................................. 95
The oscilloscope controls ............................................................................................................ 96
The Navigation controls......................................................................................................... 96
The Horizontal controls ......................................................................................................... 98
s
TBS2000 Series User Manual iii
Table of Content
The graphica
Warranted specications ........................................................................................................... 112
The default
Physically securing the oscilloscope...............................................................................................115
Environme
Safety and compliance information ................................................................................................ 117
Index
s
The Trigger controls. ... . . . ... . ... . ... . ... . .. ... . ... . ... . ... . . . ... . ... . ... . ... . . . ... . ... . ... . ... . .. ... . ... . ... . ... . . . ... . ... . ... . 98
The Vertical co
The Resources controls....................................................................................................... 100
Other front-panel controls. ... . . . ... . ... . ... . . . ... . ... . . . ... . ... . ... . . . ... . ... . . . ... . ... . ... . . . ... . ... . . . ... . ... . ... . . . ... . ... . 100
Using the menu
Front-panel connectors . .. ... . . . ... . ... . . . ... . ... . . . ... . ... . .. ... . ... . ... . . . ... . ... . .. ... . ... . . . ... . ... . . . ... . ... . .. ... . ... . .. 103
Rear-panel connectors. . ... . ... . . . ... . ... . .. ... . . . ... . ... . ... . . . ... . ... . .. ... . ... . . . ... . ... . . . ... . ... . .. ... . ... . . . ... . ... . . . .. 104
Labeling channels and buses. . . ... . ... . . . ... . ... . . . ... . ... . .. ... . ... . . . ... . ... . . . ... . ... . .. ... . ... . . . ... . ... . . . ... . ... . .. ... . 109
Oscilloscope settings that are not reset byDefault Setup................................................................... 114
ntal considerations...................................................................................................... 116
Product end-of-life handling . ... . .. ... . ... . ... . ... . .. ... . ... . ... . ... . .. ... . ... . ... . ... . .. ... . ... . ... . . . ... . ... . . . ... . ... . ... . . 116
ntrols ............................................................................................................ 99
system ....................................................................................................... 101
l user interface elements............................................................................................. 105
oscilloscope settings (Default Setup)................................................................................. 113
iv TBS2000 Series User Manual
Important safet
y information
Important saf
This manual contains information and warnings that must be followed by the user for safe operation and to keep the product in a safe condition. To safely perform service on this product, additional information is provided at the end of this section.
General safety summary
Use the product only as specied. Review the following safety precautions to avoid injury and prevent damage to this product or any produ
Comply with local and national safety codes.
For correct and safe operation of the product, it is essential that you follow generally accepted safety procedures in addition to the safety precautions specied in this manual.
The product is designed to be used by trained personnel only.
Only qualied personnel who are aware of the hazards involved should remove the cover for repair, maintenance, or adjustment.
Before use, always check the product with a known source to be sure it is operating correctly.
This product is not intended for detection of hazardous voltages.
Use personal protective equipment to prevent shock and arc blast injury where hazardous live conductors are exposed.
While using this product, you may need to access other parts of a larger system. Read the safety sections of the other component manuals for warnings and cautions related to operating the system.
cts connected to it. Carefully read all instructions. Retain these instructions for future reference.
ety information
When incorporating this equipment into a system, the safety of that system is the responsibility of the assembler of the system.
To avoid re or personal injury
Use proper power cord. Use only the power cord specied for this product and certied for the country of use.
Do not use the provided power cord for other products.
Ground the product. This product is grounded through the grounding conductor of the power cord. To avoid electric
shock, the grounding conductor must be connected to earth ground. Before making connections to the input or output terminals of the product, ensure that the product is properly grounded.
Do not disable the power cord grounding connection.
Power disconnect. The power cord disconnects the product from the power source. See instructions for the location.
Do not position the equipment so that it is difcult to access the power cord; it must remain accessible to the user at all times to allow for quick disconnection if needed.
Connect and disconnect properly. Do not connect or disconnect probes or test leads while they are connected
to a voltage source.
Use only insulated voltage probes, test leads, and adapters supplied with the product, or indicated by Tektronix to be suitable for the product.
Observe all terminal ratings. To avoid re or shock hazard, observe all ratings and markings on the product. Consult
the product manual for further ratings information before making connections to the product. Do not exceed the Measurement
TBS2000 Series User Manual v
Important safet
Category (CAT) rating and voltage or current rating of the lowest rated individual component of a product, probe, or accessory. Use
Do not apply a potential to any terminal, including the common terminal, that exceeds the maximum rating of that terminal.
Do not oat the common terminal above the rated voltage for that terminal.
Do not operate without covers. Do not operate this product with covers or panels removed, or with the c ase open.
Hazardous voltage exposure is possible.
Avoid exposed circuitry. Do not touch exposed connections and components when power is present.
Do not operate with suspected failures. If you suspect that there is damage to this product, have it inspected by
qualied service personnel.
Disable the product if it is damaged, Do not use the product if it is damaged or operates incorrectly. If in doubt about safety of the product, turn it off and disconnect the power cord. Cl early mark the product to prevent its further operation.
y information
caution when using 1:1 test leads because the probe tip voltage is directly transmitted to the product.
Before use, inspect v oltage probes, test leads, and accessories for m use probes or test leads if they are damaged, if there is exposed metal, or if a wear indicator shows.
Examine the exterior of the product before you use it. Look for cracks or missing pieces.
Use only specied replacement parts.
echanical damage and replace when damaged. Do not
Do not operate in wet/damp conditions. Be aware that condensation may occur if a unit is moved from a c old to a
warm environment.
Do not operate in an explosive atmosphere.
Keep product surfaces clean and dry.
Remove the input signals before you clean the product.
Provide proper ventilation. To ensure proper cooling, keep the sides and rear of the instrument clear of obstructions.
Slots and openings are provided for ventilation and should never be covered or otherwise obstructed. Do not push objects into any of the openings.
Provide a safe working environment. Always place the product in a location convenient for v iewing the display
and indicators.
Avoid improper or prolonged use of keyboards, pointers, and button pads. Improper or prolonged keyboard or pointer use may result in serious injury.
Be sure your work area meets applicable ergonomic standards. Consult with an ergonomics p ro fessional to avoid stress injuries.
Probes and test leads
Before connecting probes or test leads, connect the power cord from the power connector to a properly grounded power outlet.
Keep ngers behind the nger guards on the probes.
Remove all probes, test leads and accessories that are not in use.
Use only correct Measurement Category (CAT), voltage, temperature, altitude, and amperage and adapters for any measurement.
vi TBS2000 Series User Manual
rated p robes, test leads,
Important safet
y information
Beware of high voltages. Understand the voltage ratings for the probe you are using and do not exceed those ratings.
Two ratings are
important to know and understand:
The maximum me
The m aximum flo
These two volt
WARNING. To prevent electrical shock, do not exceed the maximum measurement or maximum oating voltage for the
oscilloscope input BNC connector, probe tip, or probe reference lead.
Connect and disconn
probe to the circuit under test. Connect the probe reference lead to the circuit under test before connecting the probe input. Disconnect the probe input and the probe reference lead from the circuit under test before disconnecting the probe from the measurement pr
asurement voltage from the probe tip to the probe reference lead
ating voltage from the probe reference lead to earth ground
age ratings depend on the probe and your application. Refer to the Specications manual for more information.
ect properly.
oduct.
Connect the probe output to the measurement product before connecting the
Connect and disconnect properly. De-energize the circuit under test before connecting or disconnecting the current
probe.
Connect the probe reference lead to earth ground only.
Do not connect a current probe to any wire that carries voltages above the current probe voltage rating.
Inspect the probe and accessories. Before each use, inspect probe and accessories for damage (cuts, tears, or
defects in the probe body, accessories, or cable jacket). Do not use if damaged.
Service safety
The Service safety summary section contains additional information required to safely perform service on the product. Only qualied personnel should perform service procedures. Read this Service safety summary and the General safety summary before performing any service procedures.
To avoid elec
summary
tric shock.
Do not touch exposed connections.
Do not service alone. Do not perform internal service or adjustments of this product unless another person capable of
rendering rst aid and resuscitation is present.
Disconnect power. To avoid electric shock, switch off the product power and disconnect the power cord from the mains
power before removing any covers or panels, or opening the case for servicing.
Use care when servicing with power on. Dangerous voltages or currents may exist in this product. Disconnect
power, remove battery (if applicable), and disconnect test leads before removing protective panels, soldering, or replacing components.
Verify safety after repair. Always recheck ground continuity and mains dielectric strength after performing a repair.
TBS2000 Series User Manual vii
Important safet
Terms in product manuals
These terms may appear in the product manuals:
WARNING. Warning statements identify conditions or practices that could r esult in injury or loss of life.
CAUTION. Caution statements identify conditions or practices that could result in damage to this product or other property.
Symbols and terms on the product
These terms may appear on the product:
y information
DANGER indicates an injury hazard immediately accessible as you read the m arking.
WARNING indicates an injury hazard not immediately accessible as you read the marking.
CAUTION indicates a hazard to property including the product.
When this symbol is marked on the product, be sure to consult the manual to nd out the nature o f the potential hazards and any actions which have to be taken to avoid them. (This symbol may also be used to refer the user to ratings
in the manual.)
The following symbol(s) may appear on the product:
viii TBS2000 Series User Manual
Preface
This manual describes the installation and operation of the following oscilloscopes:
TBS2072 TBS2102 TBS2074 TBS2104
Key features
This oscilloscope can help you verify, debug, and characterize electronic designs. Key features include:
100 MHz and 70 MHz bandwidths
2 channel and 4 channel models
TekVP I®Versatile Probe Interface supports active voltage and current probes for automatic scaling and units
Large 9 inch (228 mm) WVGA wide-screen color display
Sample rates up to 1 GS/s (1 channel on 2-channel instruments; 2 channels on 4-channel instruments)
Up to 20 million points record length on every channel
Preface
10,000 waveforms/second capture rate
More than 32 automated measurements
Runt and pulse width triggers
FFT analysis for waveform spectrum analysis
Wi-Fi (with optional TEKUSBWIFI dongle) and Ethernet for remote operation and programming
Embedded LXI Web site, accessed by typing instrument IP address into a Web browser, provides remote UI control and SCPI co
USB 2.0 drives; i nstalling rmware updates; and loading waveforms and settings from saved les
USB 2.0 Device port for direct PC control of the oscilloscope using TekVISA connectivity, and other remote connectivity tools that support USBTMC
Scope Intro provides a built-in overview of oscilloscope concepts and an introduction to the TBS2000 controls and feat
Help
settings
Courseware function provides on-oscilloscope teaching instruction, with hundreds of courses available on the Tektronix Education Web page and the ability to easily create courses specic to your education needs
mmand support
Host ports for quick and easy storage of screen images, instrument settings, and waveforms to USB ash
ures
Everywhere displays graphics and short text descriptions when you access the menus for most oscilloscope
TBS2000 Series User Manual ix
Preface
Terms in this m anual
These terms may appear in this manual:
WARNING. Warning statements identify conditions or practices that could r esult in injury or loss of life.
CAUTION. Caution statements identify conditions or practices that could result in damage to this product or other property.
Symbols and terms on the product
These terms may appear on the product:
DANGER indicates an injury hazard immediately accessible as you read the m arking.
WARNING indicates an injury hazard not immediately accessible as you read the marking.
CAUTION indicates a hazard to property including the product.
When this symbol is marked on the product, be sure to consult the manual to nd out the nature o f the potential hazards and any actions which have to be taken to avoid them. (This symbol may also be used to refer the user to ratings
in the manual.)
The following symbol(s) may appear on the product:
x TBS2000 Series User Manual
Conventions used in this manual
The following icons are used throughout this manual.
Preface
Sequence Step
Front panel power
Connect power
Network
USB
TBS2000 Series User Manual xi
Preface
xii TBS2000 Series User M anual
Installation
Before installation
Unpack the oscilloscope and check that you received all items listed as standard accessories. The following pages list recommended accessories and probes, oscilloscope options, and upgrades. Check the Tektronix Web site (www.tek.com) for the most current information.
Standard accessories
Accessory Description
TBS2000 Series Oscilloscopes Safety and Installation Instructions
TBS2000 Series Oscilloscopes Documentation Browser CD
Calibration certicate documenting traceability to national metrology institute(s), and ISO9001 quality system registration.
Probes (all models)
Five year warranty
Power cord
Printed safety and installation information. The instructions are translated into 10 languages.
Electronic versions of documents, including the User Manual, Programmer Manual and Technical References.
2 Ch Models: Two T PP0100 100 MHz, 10X passive voltage probes with 10 Minput resistance.
4 Ch Models: Four TPP0100 100 MHz, 10X passive voltage probes with 10 Minput resistance.
For details, refer to the warranty at the front of this manual
North America (Option A0)
Universal Euro (Option A1)
United Kingdom (Option A2)
Australia (Option A3)
Switzerland (Option A5)
Japan (Option A6)
China (Option A10)
India (Option A11)
Brazil (Option A12)
No power cord or AC adapter (Option A99)
Installation
Tektronix part number
071-3556-xx
063-4568xx
––
TPP0100
––
161-0348-xx
161-0343-xx
161-0344-xx
161-0346-xx
161-0347-xx
161-0342-xx
161-0341-xx
161-0349-xx
161-0356-xx ––
TBS2000 Series User Manual 1
Installation
Standard accessories (cont.)
Tektronix part
Accessory Description
Front-panel overlays are provided with the ordered language option.
French (Option L1)
Italian (Option L2)
German (Option L3)
Spanish (Option L4)
Japanese (Option L5)
Portuguese (Option L6)
Simplied Chinese (Option L7)
Traditional Chinese (Option L8)
Korean (Option L9)
Russian (Option L10)
number
Optional accessories
Accessory Description Tektronix part number
TEKUSBWIFI The USB module adds Wi-Fi connectivity for remote
programmability and control
TekV P I®probes that work with TBS2000 Series oscilloscopes
50 BNC adapter Connect 50 cables to the oscilloscope
Deskew pulse generator Deskew pulse generator and signal source with
Power measurement deskew and calibration xture
TEK-USB-488 Adapter GPIB to USB Adapter TEK-USB-488
Soft transit case
Hard transit case (requires use of soft transit cas e)
Visit theOscilloscope Probe and Accessory Selector Tool on the Tektronix Web site at www.tek.com
TekVPI oscilloscope interface
Converts TEK-DPG pulse generator output into a series of test point connections
Two-channel oscilloscopes
Four-channel oscilloscopes
Two- and four-channel oscilloscopes HCTEK4321
TEKUSBWIFI
013-0227-00
TEK-DPG
067-1686-00
ACD2000
ACD4000B
The TBS2000 series oscilloscopes work with multiple optional probes. (See page 11, Connecting probes to the oscilloscope.) Check the Tektronix Web site (www.tek.com) for the most current information.
2 TBS2000 Series User Manual
Installation
Related documentation
Accessory Description Tektronix part number
TBS2000 Series Oscilloscopes User Manual
TBS2000 Series Oscilloscopes Specications and Performance Verication Manual
TBS2000 Series Oscilloscopes Programmer
l
Manua
000 Series Oscilloscopes Service
TBS2 Manual
English 077-1147-xx
French 077-1264-xx
German
Italian 077-1266-xx
Spanish
Portuguese 077-1268-xx
Korean 077-1269-x
Japanese 077-1270-xx
Simple Chinese
Traditional Chinese
Russian 077-1273-xx
Describes the oscilloscope specications and performance verication procedure.
le electronically on the Documentation
Availab Browser C D or for download from www.tek.com/downloads. English only.
Describes commands for remote control of
cilloscope. Available electronically
the os on the Documentation Browser CD or for download from www.tek.com/manuals.
sh only.
Engli
ice information. Available electronically
Serv on the Documentation Browser CD or for download from www.tek.com/downloads.
ish only
Engl
077-1265-xx
077-1267-xx
077-1271-xx
077-1272-xx
8-xx
077-114
077-1149-xx
077-1150-xx
x
TBS2000 Series User Manual 3
Operating requi
rements
Operating req
Make sure to operate the instrument within the following environmental and power requirements.
uirements
Environment requirements
Characteristic Description
Operating temperature 0 °C to +50 °C, with 5 °C/minute maximum gradient, noncondensing, up to 3000 meter
Operating humidity 5% to 95% relative humidity (% RH) up to +30 °C
Operating altitude Up to 3000 meters (9842 feet)
Power requirements
Characteristic Description
Power source voltage
Power source frequency 50/60 Hz over entire source voltage range
Power consumption All models: 80 W maximum
altitude
5% to 60% RH above +30 °C up to +50 °C, noncondensing
100 V
400 Hz (360 Hz to 440 Hz) for 115 V
– 240 VAC±10% RMS, single phase
AC
AC
(100 VAC– 132 VAC) RMS source voltage range
CAUTION. A ground connection through the power cord grounding conductor is essential for safe operation.
4 TBS2000 Series User Manual
Getting acquain
ted with the oscilloscope
Getting acqua
This section shows you how to power on the oscilloscope, and uses a hands-on approach to introduce you to key oscilloscope functions, using the menu system, and verifying that the oscilloscope is operating correctly.
inted with the oscilloscope
Powering on and off the oscilloscope
Grounding the oscilloscope is necessary for safety and to take accurate measurements. The oscilloscope must share the same ground power cord into an outlet grounded to earth ground.
To connect the power cord and power on the oscilloscope:
as any circuits that you are testing. You connect the oscilloscope to ground by plugging the three-pronged
wer off the oscilloscope and remove the power cord:
To po
TBS2000 Series User Manual 5
Getting acquain
ted with the oscilloscope
NOTE. The current instrument settings are stored in nonvolatile memory when you power off the oscilloscope. The
oscilloscope restores the settings when you power on.
Changing the user interface language
You can change the language used for the oscilloscope on-screen display, measurements, readouts, and menus to one of 11 languages.
The following steps show how to change the user interface language. These steps also introduce you to the oscilloscope menu system.
1. Push the Utility front-panel button. The oscilloscope displays a side menu on the right side of the screen.
6 TBS2000 Series User Manual
Getting acquain
ted with the oscilloscope
2. Push the Langua
The oscillosc menu.
YouwillusetheMu ltip urpose knob to select and following text describes how the Multipurpose knob works.
The Multipurpose knob lets you interact with on-screen boxes.
A blue-colored M icon on a menu, message, or dialog the Multipurpose knob to select and click values in that item.
The turn arrow indicator, located below the knob, turns green when you can use the knob to m menu or dialog box.
menus, messages, and dialog
box label means that you can use
ake selections or enter values in a
ge side-menu button.
ope opens the Language
click menu items. The
The knob has two functions:
Select function, where you turn the
knob to select (highlight) a menu item. Selecting a menu item does not execute (run) that function.
Click function, where you push the
knob to either run the selected menu item or enable a eld in that menu item to enter numbers or select values.
TBS2000 Series User Manual 7
Getting acquain
ted with the oscilloscope
3. Turn the Multip language.
4. Click (push) the Multipurpose knob to enter the highlighted language. The selected language takes effect immediately.
5. Push the Menu On/Off buttontoclose the Utility menu.
urpose knob to select a
6. If you load a language other than English,
install the plastic overlay on the front panel to provide labels in that language. Fold the overlay tabs. Push the overlay over the knobs until the knob hole tabs click over the bottom edges of the knobs. Insert the overlay tabs into the small slots.
If you are changing from a non English language to English, remove the front-panel language overlay.
8 TBS2000 Series User Manual
Changing the date and time
Set the current data and time so that les that you save are marked with the correct date and time. The date and time are shown in the lower-right corner of the screen. Time is shown using a 24-hour clock.
NOTE. The clock does not automatically adjust for seasonal time changes. The calendar does adjust for leap years.
The following steps show how to set the oscilloscope clock with the current date and time. These steps also introduce you to more functions of the menu system.
1. Push Utility front-panel button.
Getting acquain
ted with the oscilloscope
2. Push Set D
button. The oscilloscope shows the Set
Date & Time menu.
3. Turn the Mu ltipurpose knob to select
the Yea
ate & Time side-menu
r eld.
TBS2000 Series User Manual 9
Getting acquain
4. Click the Multipurpose knob to enable
5. Turn the Multipurpose knob to change
6. Repeat steps 3 – 5 to select and change
7. When you have nished making all date
ted with the oscilloscope
setting the year value. A white box is drawn around t that you can use the Multipurpose knob to change that value.
the year value in the eld.
When the val Multipurpose knob. This enters the number and returns the knob to menu select mode
the remain (Month, Day, Hour, Minute).
and time changes, turn the Multipurpose knob to s click the knob to enter the date/time settings into the oscilloscope.
he number eld, indicating
ue is correct, click the
.
ing date and time settings
elect Set Date & Time, then
8. To turn off displaying the date and time,
Display Date & Time and click the
select
Multipurpose knob to toggle On or Off.
9. Push the Menu On/Off buttontoclose
the Utility side menu.
The new date and time are shown in the lower-right corner of the screen.
10 TBS2000 Series User Manual
Connecting probes to the oscilloscope
You must connect probes or cables to an oscilloscope before you can display a waveform and take measurements. The following text describes how to connect probes to the oscilloscope.
1. BNC probes or cables: Push the BNC
probe or cable on to the connector so that the connector pins align with the slots, then turn the BNC connector clockwise to lock. The probes that ship with the oscilloscope are BNC connector probes.
NOTE. If you connect a cable to the channel
input, you will need an impedance matching adapter to convert the cable impedance (typically 50 , but it depends on the cable) to work with the 1 Mchannel input impedance.
Getting acquain
ted with the oscilloscope
2. Tektronix Versatile Probe Interface (TekVPI®): Push the probe base into the channel connector until the probe base
connector clicks. To remove, push and hold the button on the probe base and pull the probe from the connector.
®
TekVPI (10X, 1X, X10, and so on).
probes automatically set the oscilloscope probe parameters such as type (voltage, current) and attenuation
Supported probe types
For more information on the many probes available for use with TBS2000 Series oscilloscopes, visit the Oscilloscope Probe and Accessory Selector tool on the Tektronix Web site (www.tek.com).
cing electrostatic damage while taking measuremens
Redu
Static electricity that builds up on your body can damage static-sensitive components.
uareworkingwithstatic-sensitive
If yo components, ground yourself when using probes. Wearing a grounding strap safely
ds static charges on your body to earth
sen ground.
Connect the grounding strap to the
cilloscope ground, or to the same ground
os circuit that the oscilloscope is connected to.
TBS2000 Series User Manual 11
Getting acquain
ted with the oscilloscope
Doing a functional check
Perform this quick functional check to verify that your oscilloscope is operating correctly.
1. Connect the oscilloscope power cable as described in Powering On the Oscilloscope. (See page 5.)
2. Power on the oscilloscope.
3. Connect a probe that came with the
oscilloscope to channel 1.
4. Connec
5. Push Default Setup. Default Setup
t the probe tip and ground lead to the PROBE COMP connectors on the oscilloscope front panel. The probe
nectstothe5Vconnector, and
tip con the ground clip connects to the ground connector.
returns the oscilloscope settings to factory default values. (See page 113,
The default oscilloscope settings (Default Setup).)
12 TBS2000 Series User Manual