Tektronix TBS1000C Specification and Performance Verification

TBS1000C Series Oscilloscope Specification and Performance Verification
Register now! Click the following link to protect your product. www.tek.com/register
*P077158302*
077-1583-02
Copyright © Tektronix. All rights reserved. Licensed software products are owned by Tektronix or its subsidiaries or suppliers, and are protected by national copyright laws and international treaty provisions. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supersedes that in all previously published material. Specifications and price change privileges reserved.
TEKTRONIX and TEK are registered trademarks of Tektronix, Inc.
Contacting Tektronix
Tektronix, Inc.
14150 SW Karl Braun Drive
P.O. Box 500
Beaverton, OR 97077
USA
For product information, sales, service, and technical support:
In North America, call 1-800-833-9200.
Worldwide, visit www.tek.com to find contacts in your area.

Table of Contents

Table of Contents
List of Tables................................................................................................................................................................................. 4
Important safety information..........................................................................................................................................................5
General safety summary........................................................................................................................................................5
Service safety summary.........................................................................................................................................................7
Terms in the manual...............................................................................................................................................................7
Terms on the product............................................................................................................................................................. 7
Symbols on the product......................................................................................................................................................... 7
Specifications ............................................................................................................................................................................... 9
Performance verification............................................................................................................................................................. 20
Required equipment.............................................................................................................................................................20
Test record........................................................................................................................................................................... 20
Performance verification procedures................................................................................................................................... 21
Self test.........................................................................................................................................................................21
Signal calibration.......................................................................................................................................................... 22
Check DC gain accuracy.............................................................................................................................................. 22
Check bandwidth.......................................................................................................................................................... 23
Check sample rate accuracy and delay time accuracy.................................................................................................24
Check edge trigger sensitivity.......................................................................................................................................25
Check Aux In edge trigger sensitivity............................................................................................................................26
Check Vertical Offset Accuracy.....................................................................................................................................28
TBS1000C Series Oscilloscope Specification and Performance Verification 3

List of Tables

List of Tables
Table 1: Performance verification................................................................................................................................................20
Table 2: Test record.....................................................................................................................................................................20
Table 3: Vertical Offset Accuracy...............................................................................................................................................0
TBS1000C Series Oscilloscope Specification and Performance Verification 4

Important safety information

Important safety information
This manual contains information and warnings that must be followed by the user for safe operation and to keep the product in a safe condition.
To safely perform service on this product, see the Service safety summary that follows the General safety summary.

General safety summary

Use the product only as specified. Review the following safety precautions to avoid injury and prevent damage to this product or any products connected to it. Carefully read all instructions. Retain these instructions for future reference.
This product shall be used in accordance with local and national codes.
For correct and safe operation of the product, it is essential that you follow generally accepted safety procedures in addition to the safety precautions specified in this manual.
The product is designed to be used by trained personnel only.
Only qualified personnel who are aware of the hazards involved should remove the cover for repair, maintenance, or adjustment.
Before use, always check the product with a known source to be sure it is operating correctly.
This product is not intended for detection of hazardous voltages.
Use personal protective equipment to prevent shock and arc blast injury where hazardous live conductors are exposed.
While using this product, you may need to access other parts of a larger system. Read the safety sections of the other component manuals for warnings and cautions related to operating the system.
When incorporating this equipment into a system, the safety of that system is the responsibility of the assembler of the system.
To avoid fire or personal injury
Use proper power cord Use only the power cord specified for this product and certified for the country of use. Ground the product This product is grounded through the grounding conductor of the power cord. To avoid
electric shock, the grounding conductor must be connected to earth ground. Before making connections to the input or output terminals of the product, ensure that the product is properly grounded. Do not disable the power cord grounding connection.
Ground-referenced oscilloscope use Do not float the reference lead of this probe when using with ground-referenced oscilloscopes.
The reference lead must be connected to earth potential (0 V).
Power disconnect The power cord disconnects the product from the power source. See instructions for the
location. Do not position the equipment so that it is difficult to operate the power cord; it must remain accessible to the user at all times to allow for quick disconnection if needed.
Connect and disconnect properly Do not connect or disconnect probes or test leads while they are connected to a voltage
source.
Use only insulated voltage probes, test leads, and adapters supplied with the product, or indicated by Tektronix to be suitable for the product.
Observe all terminal ratings To avoid fire or shock hazard, observe all rating and markings on the product. Consult the
product manual for further ratings information before making connections to the product. Do not exceed the Measurement Category (CAT) rating and voltage or current rating of the lowest rated individual component of a product, probe, or accessory. Use caution when using 1:1 test leads because the probe tip voltage is directly transmitted to the product.
Do not apply a potential to any terminal, including the common terminal, that exceeds the maximum rating of that terminal.
TBS1000C Series Oscilloscope Specification and Performance Verification 5
Important safety information
Do not float the common terminal above the rated voltage for that terminal.
Do not operate without covers Do not operate this product with covers or panels removed, or with the case open. Hazardous
voltage exposure is possible.
Avoid exposed circuitry Do not touch exposed connections and components when power is present. Do not operate with suspected
failures
Do not operate in wet/damp conditions
Do not operate in an explosive atmosphere
Keep product surfaces clean and dry Remove the input signals before you clean the product. Provide proper ventilation Refer to the installation instructions in the manual for details on installing the product so it has
Provide a safe working environment Always place the product in a location convenient for viewing the display and indicators.
If you suspect that there is damage to this product, have it inspected by qualified service personnel.
Disable the product if it is damaged. Do not use the product if it is damaged or operates incorrectly. If in doubt about safety of the product, turn it off and disconnect the power cord. Clearly mark the product to prevent its further operation.
Before use, inspect voltage probes, test leads, and accessories for mechanical damage and replace when damaged. Do not use probes or test leads if they are damaged, if there is exposed metal, or if a wear indicator shows.
Examine the exterior of the product before you use it. Look for cracks or missing pieces.
Use only specified replacement parts.
Be aware that condensation may occur if a unit is moved from a cold to a warm environment.
proper ventilation.
Slots and openings are provided for ventilation and should never be covered or otherwise obstructed. Do not push objects into any of the openings.
Avoid improper or prolonged use of keyboards, pointers, and button pads. Improper or prolonged keyboard or pointer use may result in serious injury.
Be sure your work area meets applicable ergonomic standards. Consult with an ergonomics professional to avoid stress injuries.
Probes and test leads
Before connecting probes or test leads, connect the power cord from the power connector to a properly grounded power outlet.
Keep fingers behind the protective barrier, protective finger guard, or tactile indicator on the probes.
Remove all probes, test leads and accessories that are not in use.
Use only correct Measurement Category (CAT), voltage, temperature, altitude, and amperage rated probes, test leads, and adapters for any measurement.
Beware of high voltages Understand the voltage ratings for the probe you are using and do not exceed those ratings.
Two ratings are important to know and understand:
The maximum measurement voltage from the probe tip to the probe reference lead
The maximum floating voltage from the probe reference lead to earth ground
These two voltage ratings depend on the probe and your application. Refer to the Specifications section of the manual for more information.
Warning: To prevent electrical shock, do not exceed the maximum measurement or maximum floating voltage for the oscilloscope input BNC connector, probe tip, or probe reference lead.
TBS1000C Series Oscilloscope Specification and Performance Verification 6
Important safety information
Connect and disconnect properly Connect the probe output to the measurement product before connecting the probe to the
circuit under test. Connect the probe reference lead to the circuit under test before connecting the probe input. Disconnect the probe input and the probe reference lead from the circuit under test before disconnecting the probe from the measurement product.
Connect and disconnect properly De-energize the circuit under test before connecting or disconnecting the current probe.
Connect the probe reference lead to earth ground only.
Do not connect a current probe to any wire that carries voltages or frequencies above the current probe voltage rating.
Inspect the probe and accessories Before each use, inspect probe and accessories for damage (cuts, tears, or defects in the
probe body, accessories, or cable jacket). Do not use if damaged.

Service safety summary

The Service safety summary section contains additional information required to safely perform service on the product. Only qualified personnel should perform service procedures. Read this Service safety summary and the General safety summary before performing any service procedures.
To avoid electric shock Do not touch exposed connections. Do not service alone Do not perform internal service or adjustments of this product unless another person capable of
rendering first aid and resuscitation is present.
Disconnect power To avoid electric shock, switch off the product power and disconnect the power cord from the
mains power before removing any covers or panels, or opening the case for servicing.
Use care when servicing with poweronDangerous voltages or currents may exist in this product. Disconnect power, remove battery
(if applicable), and disconnect test leads before removing protective panels, soldering, or replacing components.
Verify safety after repair Always recheck ground continuity and mains dielectric strength after performing a repair.

Terms in the manual

These terms may appear in this manual:
Warning:
CAUTION: Caution statements identify conditions or practices that could result in damage to this product or other property.
Warning statements identify conditions or practices that could result in injury or loss of life.

Terms on the product

These terms may appear on the product:
DANGER indicates an injury hazard immediately accessible as you read the marking.
WARNING indicates an injury hazard not immediately accessible as you read the marking.
CAUTION indicates a hazard to property including the product.

Symbols on the product

When this symbol is marked on the product, be sure to consult the manual to find out the nature of the potential hazards and any actions which have to be taken to avoid them. (This symbol may also be used to refer the user to ratings in the manual.)
TBS1000C Series Oscilloscope Specification and Performance Verification 7
The following symbols may appear on the product:
``` ``` ```
Important safety information
TBS1000C Series Oscilloscope Specification and Performance Verification 8

Specifications

Specifications
Model overview
Bandwidth 50 MHz 70 MHz 100 MHz 200 MHz Channels 2 2 2 2 Sample Rate 1 GS/s 1 GS/s 1 GS/s 1 GS/s Record Length 20K points 20K points 20K points 20K points
TBS1052C TBS1072C TBS1102C TBS1202C
Vertical system - analog channels
Vertical resolution 8 bits
Input sensitivity range 1 mV/Div to 10V/Div in 1-2-5 sequence with probe attenuation set to 1X
Maximum input voltage 300 V RMS, Installation Category II; derate above 4 MHz at 20 dB per decade to 200 MHz
Vertical offset range 1 mV/div to 50 mV/div: +/- 1V
100 mV/div to 500 mV/div: +/- 10 V
1 V/div to 5 V/div: +/- 100 V
Bandwidth limit 20 MHz (Typ)
Input coupling DC or AC
Input resistance, DC coupled 1 MΩ, ±2 %
Input capacitance, DC coupled 14 pF ± 2 pF
Vertical zoom Vertically expand or compress a live or a stopped waveform
Acquisition modes
Sample Acquire sampled values Peak Detect Captures glitches as narrow as 3.5 ns at all
sweep speeds.
Average From 2 to 256 waveforms included in
average.
Hi-Res Averages multiple sample of one acquisition
interval into one waveform point.
Roll Scrolls waveforms right to left across the
screen at sweep speeds slower than or equal to 40 ms/div
TBS1000C Series Oscilloscope Specification and Performance Verification 9
Loading...
+ 19 hidden pages