Tektronix RSA6106A Field Install Instructions

Instructions
RSA6100A Series Real-Time Spectrum Analyzers
Phase Noise and Jitter Measurement (Option 11) Upgrade
071-2558-00
Warning
www.tektronix.com
*P071255800*
071255800
Copyright © Tektronix. All rights reserved. Licensed software products are owned by Tektronix or its subsidiaries or suppliers, and are protected by national copyright laws and international treaty provisions.
Tektronix products are covered by U.S. and foreign patent s, issued and pending. Information in this publication superced es that in all previously published material. Specifications and price change privile ges reserved.
TEKTRONIX and TEK are registered trademarks of Tektronix, Inc.
Contacting Tektronix
Tektronix, Inc. 14200 SW Karl Braun Drive P.O. Box 500 Beaverton, OR 97077 USA
For product information, sales, service, and technical support:
H In North America, call 1-800-833-9200.
H Worldwide, visit www.tektronix.com to find contacts in your area.
Kit Description
Products
Kit Parts List
This kit describes the installation of the Phase Noise and Jitter Measurement Upgrade (Option 11) in an RSA6100A Series Real-Time Spectrum Analyzer.
RSA6100A Series All Serial Numbers.
Quantity Part number Description
1ea 071-2558-00 MANUAL, TECH: INSTALLATION, RSA6UP, OPT11
1ea NS DATA SHEET; SOFTWARE OPTION KEY AUTHORIZATION
CERTIFICATE, UPGRADE KITS
1ea NS LABEL, MANUFACTURED; OPTION KEY UPGRADE LABEL
2.100 X 2.700, SAFETY CONTROLLED
NS Not Saleable
RSA6100A Series Phase Noise and Jitter Measurement Installation (Option 11)
1
Kit Description
2
RSA6100A Series Phase Noise and Jitter Measurement Installation (Option 11)
Installation Instructions
The software that takes Phase Noise and Jitter measurements is included in all spectrum analyzers running application software version 1.3.x or higher. However, you need an option installation key to activate it. To activate the Phase Noise and Jitter Measurement capability, you must enter the new option installation key supplied with this kit into the spectrum analyzer application. If your spectrum analyzer is running an earlier version of the application software, you will have to download and install the latest software before you can enter the option key that enables the Phase Noise and Jitter measurements.
Updating the Instrument Application Software
Select Help > About.. from the spectrum analyzer software menu bar to check the version of your spectrum analyzer’s software. The software version appears at the top-right corner of the About box. If your spectrum analyzer is not running version 1.3.x or later software, you must download and install the latest version of the application software. If your spectrum analyzer is running version 1.3.x or later software, proceed to Install Option Key.
To install the latest version of the spectrum analyzer application software:
Install Option Key
1. Use your Web browser to go to: www.tektronix.com/software.
2. Enter your instrument model number in the Search by keyword text box and click Go.
3. Follow the link for the RSA6100A Series Software and download the
software.
4. Follow the instructions on the Web page to install the software.
To activate the Phase Noise and Jitter Measurement option:
1. In the spectrum analyzer application, select Tools > Install Upgrades.The Install Upgrade wizard starts, as shown in Figure 1. Click Continue.
RSA6100A Series Phase Noise and Jitter Measurement Installation (Option 11)
3
Installation Instructions
Figure 1: Starting the option upgrade
2. The Install Upgrade Enter Key screen appears (see Figure 2).
Figure 2: Entering the option installation key
3. Type the option installation key into the empty text box and click Continue.
An Installation Success dialog box opens, as shown in Figure 3.
4
RSA6100A Series Phase Noise and Jitter Measurement Installation (Option 11)
Figure 3: Upgrade success notification
Installation Instructions
4. Click Close. Exit and restart the RSA6100A application to enable the new feature.
5. Press the Displays button on the RSA6100A.
6. In the Folders panel, select the RF Measurements folder.
7. In the Available displays panel, verify that you can select the Phase Noise
measurement.
This completes the installation of the Option Installation Key.
Installing the Option Key Label
Place the new option key label over the existing label on the instrument rear panel.
This completes the installation of the Phase Noise and Jitter Measurement (Option 11) upgrade kit.
g End of document g
RSA6100A Series Phase Noise and Jitter Measurement Installation (Option 11)
5