Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication
supersedes that in all previously published material. Specifications and price change privileges reserved.
TEKTRONIX and TEK are registered trademarks of Tektronix, Inc.
Contacting Tektronix
Tektronix, Inc.
14150 SW Karl Braun Drive
P.O. B o x 5 0 0
Beaverto
USA
For product information, sales, service, and technical support:
n, OR 97077
In North America, call 1-800-833-9200.
Worl dwid e, vis it www.tektronix.com to find contacts in your area.
Page 3
Service safety summary
Only qualified personnel should perform service procedures. Read this Service
Safety Summary and the General Safety Summary located in the RSA5100B
Real-Time Si
before performing any service procedures.
Do Not Service Alone. Do not perform internal service or adjustments of this
product unless another person capable of rendering first aid and resuscitation is
present.
Disconnect Power. To avoid electric shock, switch off the instrument power, then
disconnect the power cord from the mains power.
UseCareWhenServicingWithPowerOn. Dangerousvoltagesorcurrentsmay
exist in this product. Disconnect power, remove battery (if applicable), and
nect test leads before removing protective panels, soldering, or replacing
discon
components.
gnal Analyzer Service manual (Tektronix part number 077-0903-XX)
To avo
id electric shock, do not touch exposed connections.
RSA5100B Series Hard Drive Upgrades1
Page 4
Kit description
Kit description
Products
This kit describes the installation of the following upgrade options:
Option 56: Removable Solid State Drive
Option 59: Internal Hard Drive
RSA5103B Series. All serial numbers.
RSA5106B Series. All serial numbers.
Option 56 kit parts list
RSA5115B
Series. All serial numbers.
RSA5126B Series. All serial numbers.
QuantityPart numberDescription
1 ea075-1056-XX
1 ea071-2191-XX
2 ea211-1050-XX
4 ea211-1081-XX
1 ea407-5337-XX
1 ea407-5473-XX
MANUAL, TECH: RSA5KB Option 56 and 59
INSTALLATION INSTRUCTIONS
MANUAL, TECH; SVCPT-UPG; TEKTRONIX
SUPPLEMENTAL INFORMATION SHEET FOR
THE PEOP LES REPUBLIC OF CHINA; CHINA
ROHS
SCREW, MACHINE; M3 X 0.5 X 3.5MM,
FLAT WAFER HD W/SERRATIONS ST R ESS
RELIEVED, PHL, ZINC PLATED STEEL
BRACKET, RHDD; SATA COMBO CABLE
RETENTION
BRACKET; HARD DRIVE 2.5 INCH REMOVABLE
1 ea335-3314-XX
1 ea850-0263-XX
1ea
N/ALABEL, MANUFACTURED; PRODUCT LABEL,
MARKER, ID, REMOVABLE HD
DRIVE ASSEMBLY; REMOVABLE HARD DRIVE,
PROGRAMMED, RSA5XXXB SERIES
SAFETY CONTROLLED
2RSA5100B Series Hard Drive Upgrades
Page 5
Kit description
Option 59 kit p
arts list
QuantityPart numberDescription
1 ea075-1056-XX
1 ea071-2191-XX
1 ea200-5324-XX
4 ea210-1543-XX
4 ea211-0510-XX
2 ea211-0690-XX
4 ea348-1835-XX
1 ea850-0264-XX
1ea
N/ALABEL, MANUFACTURED; PRODUCT LABEL,
MANUAL, TECH: RSA5KB Option 56 and 59
INSTALLATION INSTRUCTIONS
MANUAL, TECH; SVCPT-UPG; TEKTRONIX
SUPPLEMENTAL INFORMATION SHEET FOR
THE PEOPLE S REPUBLIC OF CHINA; CHINA
ROHS
COVER; EMPTY DRIVE BAY
SCREW, SHOULDER, SPECIAL; 6-32 (USE WITH
VIBE ISOLATION GROMMETT)
SCREW, MACHINE; 6-32 X 0.375, PNH, ZINC
PLATED STEEL, T15
SCREW, MACHINE; 6-32 X 0.875, PNH, BLACK
ZINC PLATED STEEL, TORX & SLOT
GROMMET; VIBRATION ISOLATION
DRIVE ASS EMBLY; INTERNAL FIXED DRIVE,
PROGRAMMED, RSA5XXXB SERIES
SAFETY CONTROLLED
RSA5100B Series Hard Drive Upgrades3
Page 6
Removing the installed drives
Removing the installed drives
This section contains all the procedures to remove Option 56 (Removable Hard
Disk Drive) or Option 59 (Internal Hard Disk Drive only) from your instrument.
The section f
Minimum tool and equipment list
ollowing this one describes the installation of the new drive(s).
The followi
standard tools that are readily available.
Table 1: Tools required for installation
Item
no.NameDescription
1.
2.No. 2 Phi
3.P-1 Phi
4.
5.
These instructions are for qualified service personnel who are familiar
with servicing the product. If you need further details for disassembling or
reassembling the product, refer to the RSA5100B Series Real-Time SignalAnalyzers Service Manual, Tektronix part number 077-0903-XX.
ng tools are required to for installation of this kit. All tools are
Phillips or Pozidriv-driver tip for number 2 size screw heads
Phillips driver tip for P-1 size screw heads
TORX driver tip for T-15 size screw heads
TORX driver tip for T-20 size screw heads
moving a removable hard disk drive (Option 56)
Re
WARNING. To avoid electric shock, switch off the instrument power, then
disconnect the power cord from the mains power. Failure to do so could result
in injury or death.
4RSA5100B Series Hard Drive Upgrades
Page 7
Removing the installed drives
If you are upgra
assembly from the instrument to begin the upgrade process. Perform the following
steps to remove the removable hard disk.
1. Loosen the thumbscrews securing the drive to the front panel.
2. Grasp the dr
straight out of the instrument.
3. Place the re
protected location for possible future use or discard the drive.
ding from Option 56 to Option 59, you need to remove the drive
ive assembly by the thumbscrews and pull the drive assembly
moved drive assembly in anti-static packaging and store it in a
Removing the internal hard drive (Option 59)
NOTE. Right-side or left-side references in these instructions assume you are
viewing the instrument from the front panel.
WAR NI NG . To avoid electric shock, switch off the instrument power, then
disconnect the power cord from the mains power. Failure to do so could result
ry or death.
in inju
If you are upgrading from Option 59 (internal hard drive) to Option 56, you have
move the internal hard drive from your instrument.
to re
1. Remove the power cord.
2. If it is installed, pull the front cover off the instrument.
3. Remove the two T-15 Torx-head screws that secure the plastic carrying handle
to the side of the instrument. (It is not necessary to remove the black metal
handles.) (See Figure 1.)
4. Remove four T15 Torx-head screws along each side that attach the top and
bottom covers to the instrument, and two T20 screws near the front edge of
he top cover (next to the folding handles).
t
5. Remove the top and bottom covers. Remove the top cover by pulling it
straight back about 1 inch. Pull out on the sides of the top cover, flexing the
sides slightly to clear the instrument chassis, and pull the top cover away
from the instrument.
6. Remove the eighteen T15 Torx-head screws that secure the top shield to the
chassis and remove the shield.
RSA5100B Series Hard Drive Upgrades5
Page 8
Removing the installed drives
Figure 1: Remove covers
6RSA5100B Series Hard Drive Upgrades
Page 9
Removing the installed drives
Removing the internal hard
drive
1. Disconnect the
out of the way.
two video cables from the PC carrier board. Move the cables
2. Remove the four screws at the corners of the hard disk drive mounting plate
that secure the mounting plate to the instrument.
3. Lift the hard disk drive mounting plate out of the instrument. Disconnect the
SATA cable from the hard disk drive.
4. Remove the four screws that secure the hard disk drive to the mounting plate.
RSA5100B Series Hard Drive Upgrades7
Page 10
Installing new drive options
5. Place the remov
protected location for possible future use or discard the drive.
NOTE. If you discard or recycle the removed drive, be sure to follow your
organization’s security protocols to ensure the destruction of sensitive data.
6. Reinstall the hard disk drive mounting plate in the chassis.
ed hard drive in anti-static packaging and store it in a
Installing new drive options
This sections describes how to install your new drive options.
Installing Option 56: Removable hard disk drive
To perform the following procedure you must have already removed option 59
from your instrument. (See page 5, Removing the internal hard drive (Option 59).)
1. Attach the removable hard drive to the removable hard disk drive bracket
(part number 407-5473-XX) with four screws (part number 211-1081-XX)
using a torque driver with a P1 tip. Tighten the screws to 4.0 in-lbs.
2. Attach the removable hard drive label to the removable hard drive bracket.
Start by centering one end of the label and making it flush with the bracket.
Make sure the label is correctly oriented with the bottom of the label aligned
with the bottom of the bracket.
3. Slide the removable hard disk drive assembly into the drive opening and
secure the hard drive with the two thumbscrews.
8RSA5100B Series Hard Drive Upgrades
Page 11
Installing new drive options
4. Connect the SAT
removable hard drive.
5. Slide the SATA combo cable retention bracket (part number 407-5337-XX)
over the cable and secure the retention bracket with two screws (part number
211-1050-XX) using a torque driver with a T15 tip. Tighten the screws
to 4.0 in-lbs.
A and power cable connector to the connector on the
Reinstall top shield and
cosmetic covers
RSA5100B Series Hard Drive Upgrades9
1. Place the instrument on its bottom feet.
2. Place the top shield on top of the instrument and reinstall the eighteen T15
Torx-head screws.
3. Place the instrument on its rear feet, so the front panel is facing up and the
topistowardyou.
4. Place the top cover over the top of the instrument and slide it toward the
front panel. Make sure that the top cover wraps around the flanges on the
rear panel on all three sides.
Page 12
Installing new drive options
5. Reinstall the f
edge of the top cover (next to the folding handles) that secure the top cover
to the instrument.
6. Rotate the instrument so the bottom faces you.
7. Place the bo
8. Align the four screw holes on each side in the top and bottom covers with the
holes in the
side. Torque these screws to 8.0 in/lb.
9. Position t
instrument, and install the two T15 Torx-head screws that secure it in place.
Torque these screws to 8.0 in/lb.
This completes the upgrade to Option 56.
our T20 Torx-head screws (two on each side) near the front
ttom cover on the instrument, with the flip feet towards the front.
chassis, and install eight T15 Torx-head screws, four on each
he plastic carrying handle and its bracket on the right side of the
Installing Option 59: Internal hard drive
To perform the following procedure you must have already removed Option
56 from your instrument. (See page 4, Removing a removable hard disk drive(Option 56).)
To install the internal hard drive:
1. Disconnect the video cables from the PC Carrier board and fold them over
the front of the instrument.
2. Remove the four screws that secure the HDD bracket to the chassis and
remove the bracket.
10RSA5100B Series Hard Drive Upgrades
Page 13
Installing new drive options
3. Install four grommets (part number 348-1835-XX) on the HDD bracket as
shown.
4. Plac
RSA5100B Series Hard Drive Upgrades11
e the drive assembly (part number 850-0264-XX) onto the HDD bracket
so that the connector appears in the cutout in the HDD bracket. Secure
the drive assembly to the HDD bracket with four screws (part number
210-1543-XX) using a torque drive with a P1 tip. Tighten the screws to
4.0 in-lbs.
Page 14
Installing new drive options
5. Connect the HDD SATA cable to the drive assembly.
6. Place the drive assembly and HDD bracket on the chassis as shown. Secure
the HDD bracket to the chassis with four screws using a torque driver with a
T15 tip. Tighten these screws to 10 in/lb.
12RSA5100B Series Hard Drive Upgrades
Page 15
Installing new drive options
Reinstall top
cosmetic covers
shield and
7. Reconnect the s
8. Reconnect the larger video cable to the PC Carrier board.
1. Place the instrument on its bottom feet.
2. Place the top shield on top of the instrument and reinstall the eighteen T15
Torx-head screws.
3. Place the instrument on its rear feet, so the front panel is facing up and the
topistowardyou.
4. Place the top cover over the top of the instrument and slide it toward the
front panel. Make sure that the top cover wraps around the flanges on the
rear panel on all three sides.
5. Reinstall the four T20 Torx-head screws (two on each side) near the front
edge of the top cover (next to the folding handles) that secure the top cover
to the instrument.
6. Rotate the instrument so the bottom faces you.
7. Place the bottom cover on the instrument, with the flip feet towards the front.
8. Align the four screw holes on each side in the top and bottom covers with the
holes in the chassis, and install eight T15 Torx-head screws, four on each
side. Torque these screws to 8.0 in/lb.
maller video cable to the PC Carrier board.
tach labels
At
Attach the product/option
label
9. Position the plastic carrying handle and its bracket on the right side of the
instrument, and install the two T15 Torx-head screws that secure it in place.
Torque these screws to 8.0 in/lb.
This completes the upgrade to Option 5 9.
Please attach all labels provided in this k it on the instrument’s rear panel.
Place the new product label over the existing label on the rear panel.
RSA5100B Series Hard Drive Upgrades13
Page 16
Verify instrument software version
Verify instru
ment software version
Tektroni x re
your instrument.
1. Select Help
2. Use your Web browser to go to: www.tektronix.com/software.
3. Search for your instrument’s model number and follow the link to the software.
4. If the installed software is older than that available, download the software.
5. Follow the instructions on the Web page to install the software.
■ End of D
commends to update to the latest available application software for
> About to check the software version.
ocument ■
14RSA5100B Series Hard Drive Upgrades