Tektronix RSA34UP, RSA3300B, RSA3400B Field Install Instructions

Instructions
RSA3303B, RSA3308B, & RSA3408B Real-Time Spectrum Analyzers Software Upgrade
071-2427-00
www.tektronix.com
071242700
Copyright © Tektronix. All rights reserved. Licensed software products are owned by Tektronix or its subsidiaries or suppliers, and are protected by national copyright laws and international treaty provisions.
Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supercedes that in all previously published material. Specifications and price change privileges reserved.
TEKTRONIX and TEK are registered trademarks of Tektronix, Inc.
Contacting Tektronix
Tektronix, Inc. 14200 SW Karl Braun Drive
P.O. Box 500 Beaverton, OR 97077 USA
For product information, sales, service, and technical support:
H In North America, call 1-800-833-9200.
H Worldwide, visit www.tektronix.com to find contacts in your area.
Software Upgrade
This kit includes materials to upgrade the basic software and optional analysis software for the following products:
H RSA3303B
H RSA3308B
H RSA3408B
The software is contained in the CD-ROM supplied with this kit. You have to install the software via LAN from a CD-ROM drive of an external PC to the analyzer. Prepare a Windows PC with which the analyzer is able to share the CD-ROM drive.
There are two ways to connect the analyzer and the PC (see Figure 1):
H Connect the analyzer to a single PC using the LAN cross cable supplied with
H Connect the analyzer to a PC via LAN.
this kit.
or
LAN cross cable supplied with this kit Ethernet LAN
The software is installed via network from the CD-ROM drive of an external PC to the analyzer.
Figure 1: Connection between the analyzer and PC
NOTE. When you connect the analyzer to LAN (the right case in Figure 1), contact your system administrator for the network settings.
The details of the software upgrade are provided on the following pages.
RSA3303B, RSA3308B, & RSA3408B Software Upgrade Instructions
1
Software Upgrade
Before Starting the Software Installation
Before starting installation of the latest version of software, set up the analyzer and the PC.
Setting Up the Analyzer
Checking the Version of Existing Application Software.
1. Turn on the power to the analyzer.
2. Press the System key on the front panel.
3. Press the Versions and Installed Options... side key.
The screen as shown in Figure 2 appears.
Main system version
Optional software versions
Figure 2: Checking the software version (an example of RSA3408B)
Note the versions of the main system and optional software (if installed). The version information may be necessary for troubleshooting if the software upgrade did not complete normally.
Connecting a Mouse and a Keyboard. Connect a USB mouse and a USB keyboard to the USB ports on the side panel. You can also connect the mouse to the USB port on the keyboard.
RSA3303B, RSA3308B, & RSA3408B Software Upgrade Instructions
2
Software Upgrade
USB ports
Front
Figure 3: USB ports (side panel)
Displaying Windows XP Desktop. Display the Windows XP desktop on the screen
of the analyzer with these steps:
1. With the mouse, move the pointer to the bottom of screen. The task bar appears.
2. Right click the icon indicating the analyzer model name (located on the task bar). A menu opens. The figure below is an example of RSA3408B.
3. Select Close from the menu.
The analyzer system program stops, and the Windows XP desktop displays.
RSA3303B, RSA3308B, & RSA3408B Software Upgrade Instructions
3
Software Upgrade
Network Settings for the Analyzer. No network setting is made for the analyzer when it is shipped from the factory. Configure your analyzer with the following procedure:
H When you connect the analyzer to a single PC with the LAN cross cable:
Use the following steps to set the networking parameters.
H When you connect the analyzer to a PC via LAN:
Contact your system administrator for the network settings. If the analyzer is already connected to the LAN, set up the CD-ROM drive of a PC (other than the analyzer) in shared status and insert the CD-ROM (supplied with this upgrade kit) into its CD-ROM drive to upgrade the software in accordance with Installing the Software on page 10.
1. From the Windows desktop of the analyzer, select the following: Start Setting Control Panel Network Connections.
2. Double-click Local Area Connection.
RSA3303B, RSA3308B, & RSA3408B Software Upgrade Instructions
4
Software Upgrade
3. In the Local Area Connection Properties dialog box, select Internet Pro­tocol (TCP/IP) in the General tab and then click the Properties button.
4. In the Internet Protocol (TCP/IP) Properties dialog box, select Use the fol­lowing IP address and then enter the IP address and the subnet mask.
For example, enter 192.168.10.1 for the IP address and 255.255.255.0 for the subnet mask.
When finished, click the OK button.
RSA3303B, RSA3308B, & RSA3408B Software Upgrade Instructions
5
Software Upgrade
In the Local Area Connection Properties dialog box, click the
5.
Advanced tab
.
6. Clear the Internet Connection Firewall checkbox and then click OK.
RSA3303B, RSA3308B, & RSA3408B Software Upgrade Instructions
6
Software Upgrade
In the Internet Connection Firewall dialog box, click Ye s.
7.
8. When you finish the network settings, close all of the windows.
9. Press the On/Standby switch on the front panel to turn the power off.
Setting Up the PC
Network Settings for the PC. Set networking parameters on the PC in the same
manner as for the analyzer. Refer to Network Settings for the Analyzer on page 4 for the procedure.
In step 4 on page 5, enter a different IP address for the PC than for the analyzer. For example, enter 192.168.10.2 for the IP address and 255.255.255.0 for the subnet mask as shown in the figure below.
RSA3303B, RSA3308B, & RSA3408B Software Upgrade Instructions
7
Software Upgrade
Setting Up the CD-ROM Sharing.
1. On the Windows desktop, double-click on the My Computer icon.
2. Select the CD-ROM drive icon and then click on it with the right
mouse button. A menu appears.
3. From the menu, select Sharing...
4. The CD-ROM Property dialog box opens. From the Sharing tab, select Share this folder.
5. Insert the CD-ROM supplied with this kit into the shared CD-ROM drive.
Connecting the Analyzer with the PC. Connect the analyzer with the PC via LAN. Figure 4 shows the Ethernet connector location on the analyzer.
Figure 4: Ethernet connector (side panel)
Ethernet 10/100 BASE-T connector
Front
RSA3303B, RSA3308B, & RSA3408B Software Upgrade Instructions
8
Software Upgrade
1. Connect a LAN cable.
NOTE. Leave the mouse and keyboard connected to the analyzer.
H When you connect the analyzer to a single PC:
Connect a LAN cross cable supplied with this kit to the analyzer and to the PC Ethernet port.
LAN cross cable
included in the kit
H When you connect the analyzer to a PC via LAN:
NOTE. When you connect the analyzer to your LAN, contact your system administrator for the network settings such as IP address. Do not use the LAN cross cable (supplied with the kit) for the connection in this case.
Ethernet LANEthernet LAN cable
2. Turn on the power to the analyzer.
3. Exit the analyzer system program to display the Windows XP desktop.
(Refer to Displaying Windows XP Desktop on page 3 for the procedure.)
RSA3303B, RSA3308B, & RSA3408B Software Upgrade Instructions
9
Software Upgrade
Installing the Software
Search for the PC to be shared, then install the new software from the CD-ROM supplied with the upgrade kit.
Searching for the PC
Being Shared
Search for the PC with the shared CD-ROM drive:
1. From the Windows desktop of the analyzer, right click the My Net­work Places icon. From the menu, select Search for Computers...
2. In the Search Results Computers dialog box, enter the shared PC name in the Computer name field (for example, “PC123”), and then click the Search button to start searching for the PC. If the PC is found, the name appears in the Name list.
10
RSA3303B, RSA3308B, & RSA3408B Software Upgrade Instructions
Software Upgrade
NOTE. If the name of the PC is not displayed, repeat the search process after several minutes.
Copying the Software
from the CD-ROM
Use the following steps to copy the software from the CD-ROM.
1. Double-click the name of the PC (“PC123” in this example) displayed in the Search Results Computers dialog box.
2. A list of folders shared with the PC is displayed. Double-click the CD-ROM
drive in shared status to display the CD-ROM contents.
3. From the list of files stored in the CD-ROM, double-click Setup.exe.
The setup starts. The following figure shows the “Preparing to Install...” screen before starting the installation.
If you want to abort the installation, click Cancel.
RSA3303B, RSA3308B, & RSA3408B Software Upgrade Instructions
11
Software Upgrade
4. When the installation starts, the following message is displayed. Click Next.
5. The InstallShield Wizard dialog box appears. Click Next to start file copy.
12
RSA3303B, RSA3308B, & RSA3408B Software Upgrade Instructions
Software Upgrade
During the installation, the setup status is displayed as shown in the following figure.
6. When the installation is completed, the message is displayed as shown in the following figure. Click Finish.
7. When you finish the installation, close all of the windows.
8. Turn the analyzer off and back on again by pressing the On/Standby switch
on the front panel to restart the analyzer.
RSA3303B, RSA3308B, & RSA3408B Software Upgrade Instructions
13
Software Upgrade
Entering the Soft Key Code
Enter the soft key code (indicated on the SOFT KEY label supplied with this upgrade kit) on the analyzer to enable the software.
1. Press the System key on the front panel.
2. Press the Versions and Installed Options... side key.
3. Press the Option Key side key and then enter the soft key code using the
USB keyboard or from the keypad of the analyzer.
NOTE. To input “”(hyphen) from the keypad, press the “.” (period) key.
Figure 5: Entering the soft key code
4. After you enter the soft key code, press the Change Option Key side key to
Option Key Enters the soft key code.
Change Option Key Activates the software.
activate the software. The analyzer displays either of these two messages at the bottom of screen:
H “Valid key entered. Please restart instrument”
indicates that the optional software has been successfully enabled. Restart the analyzer. Refer to the User Manual for details on operation.
H “Option key: Bad Keystring”
indicates that you entered an incorrect value. Reenter the soft key code.
14
RSA3303B, RSA3308B, & RSA3408B Software Upgrade Instructions
Attaching the Soft Key and the ID Labels
After you finish the software installation, attach the soft key and the ID labels (supplied with this upgrade kit) onto the rear panel of the analyzer. Figure 6 shows the locations for these labels.
RSA3303B RSA3308B
Software Upgrade
RSA3408B
ID label
ID label
Soft key label
Soft key label
Figure 6: Attaching the soft key and the ID labels
This completes the software upgrade procedure.
RSA3303B, RSA3308B, & RSA3408B Software Upgrade Instructions
15
Software Upgrade
Installing the RTPA2A Probe Adapter Driver Software
If you use the RTPA2A Probe Adapter, you must install an additional device driver on your analyzer, enabling communication with the probe adapter hardware through a USB cable.
Before You Start
Installing the Software
H You do not need to exit the analyzer application, reboot the analyzer, or
cycle power on the analyzer at any time during this procedure.
H Verify that the analyzer is using the main system version 3.01.004 or higher.
H If the analyzer is currently acquiring the signal, press the Run/Stop key until
it enters the PAUSE state. This allows Windows XP to detect the hardware and activate the driver much faster.
H Connect power to the RTPA2A probe adapter (refer to the RTPA2A manual).
1. Connect a USB cable from the probe adapter to the analyzer. Use the side-mounted USB ports (see Figure 7) or you can use the ports on the back of the keyboard.
USB ports
Front
16
Figure 7: USB ports (side panel)
RSA3303B, RSA3308B, & RSA3408B Software Upgrade Instructions
Software Upgrade
2. After a short wait, Windows XP will display the Found New Hardware Wizard. Select “No, not this time”, as shown, and click Next.
3. Select “Install from a list or specific location (Advanced)”, and click Next.
RSA3303B, RSA3308B, & RSA3408B Software Upgrade Instructions
17
Software Upgrade
4. Select “Include this location in the search” and use Browse to identify the following path: C:\Program Files\Tektronix\wca200a\ProbeAdapterDriver. Click Next.
5. Soon after the installation begins, the following dialog box will appear.
18
RSA3303B, RSA3308B, & RSA3408B Software Upgrade Instructions
Software Upgrade
6. Click Continue Anyway, and allow the driver to complete installation.
7. Click Finish.
RSA3303B, RSA3308B, & RSA3408B Software Upgrade Instructions
19
Software Upgrade
8. Verify that the driver was installed.
a. Select Start Settings Control Panel Add/Remove Programs.
b. Search the “Currently Installed Programs” list for “Tektronix RTSA
Probe Adapter USB Drivers”.
20
9. Verify that the probe adapter is functioning correctly. Refer to the performance verification procedure in the RTPA2A Instruction Manual (Tektronix part number 071-1766-XX).
RSA3303B, RSA3308B, & RSA3408B Software Upgrade Instructions
インストラクション・シート
RSA3303BRSA3308BRSA3408B
ソフトウェア・アップグレード
このアップグレード・キットでは、次の機種の基本ソフトウェアと各種解析ソフト ウェア(オプション)をアップグレードします。
H RSA3303B H RSA3308B H RSA3408B
ソフトウェアは、付属の CD -ROM に入っています。LAN 経由で外部 PC CD ­ROM ドライブから本機器に読み込ませます。ネットワークを介して CD-ROM
共有できる Windows PC を用意してください。 本機器と PC の接続方法は、次の 2通りがあります(図 1)。
H 本機器を付属の LAN クロス・ケーブルで PC 11 で接続する H 本機器を LAN 経由で PC に接続する
または
ソフトウェアは、ネットワーク経由で外部 PC の CD-ROM ドライブから読み込ませます。
1:本機器と PC の接続
注:本機器を LA N に接続する場合(上図右側の場合)のネットワーク設定につい
ては、システム管理者にお問い合わせください。
Ethernet LAN付属の LANクロス・ケーブル
以下に詳細な手順を示します。
インストラクション・シート 071-2427-00
1
ソフトウェア・アップグレード
インストールの前に
ソフトウェアをインストールする前に本機器と PC のセットアップを行います。
本機器のセットアップ
既存アプリケーションのバージョン確認
現在インストールされているアプリケーションのバージョンを確認します。
1. 本機器の電源を入れます。
2. 前面パネルの System キーを押します。
3. Versions and Installed Options...サイド・キーを押します。
4. 2 のような画面が表示されます。
メイン・システムとオプション(インストールされている場合)のバージョン を確認してください。これらのバージョン情報は、ソフトウェアのアップグ レードが正常に行なわれなかった場合、トラブルシューティングの際に必要に なることがあります。
メイン・システムのバージョン
オプションのバージョン
2:バージョンの確認(RSA3408B 型の例)
2
RSA3303B/RSA3308B/RSA3408B 型
ソフトウェア・アップグレード
マウスとキーボードの接続
USBマウスおよびキーボードを側面パネルの USBコネクタに接続します(図 3)。 マウスは、キーボードの USB コネクタにも接続できます。
USB コネクタ
前面
3USB コネクタ(側面パネル)
Windows XP デスクトップ画面の表示
本機器の画面に Windows XP デスクトップを表示します。
1. マウスを使い、ポインタを画面の下端に移動します。 タスク・バーが表示されます。
2. タスク・バー内で、機器型名を示すアイコン(下図は、RSA3408B 型の例)に ポインタを移動し、マウス右ボタンをクリックします。メニューが現れます。
インストラクション・シート
3. メニューから 閉じる を選択します。 本機器のシステム・プログラムが終了し、Windows XP のデスクトップ画面が
表示されます。
3
ソフトウェア・アップグレード
本機器のネットワーク設定
本機器の出荷時には、ネットワークの設定はされていません。次の手順で設定して ください。
H 本機器を付属の LAN クロス・ケーブルで PC 11 で接続する場合
H 本機器を LAN 経由で PC に接続する場合
1. マウスを使用し、本機器の Windows デスクトップ画面から Start Sett ing
下記の手順でネットワークの設定を行います。
ネットワークの設定については、システム管理者にお問い合わせください。本 機器がすでに LAN に接続されている場合には、他の PC CD-ROM ドライブ を共有設定にして、付属の CD-ROM を挿入し、10ページの「ソ フトウェ アの インストール」に進んで、アップグレードを実行してください。
Control Panel Network Connections を選択します。
2. Local Area Connection をダブルクリックします。
4
RSA3303B/RSA3308B/RSA3408B 型
ソフトウェア・アップグレード
3. Local Area Connection Properties ダイアログ・ボックスの Genera l タブで、
Internet Protocol (TCP/IP) を選択し、Properties ボタンをクリックします。
4. Internet Protocol (TCP/IP) Properties ダイアログ・ボックスで、Use the follow- ing IP address を選択し、IP アドレスとサブネット・マスクを入力します(ここ
では、IP アドレス 192.168.10.1、サブネット・マスク 255.255.255.0)。
入力し終えたら OK をクリックします。
インストラクション・シート
5
ソフトウェア・アップグレード
5. Local Area Connection Properties ダイアログ・ボックスで Advanced タブを選択 します。
6. Internet Connection Firewall のチェックを外し、OK をクリックします。
7. Internet Connection Firewall ダイアログ・ボックスで Ye s をクリックします。
8. 作業が終了したら、すべてのウィンドウを閉じます。
9. 前面パネルの On/Standby ボタンを押して、電源を切ります。
6
RSA3303B/RSA3308B/RSA3408B 型
ソフトウェア・アップグレード
PC のセットアップ
PC のネットワーク設定
本機器と同様に PC でネットワーク設定を行います。 設定手順については、前節「本機器のネットワーク設定」を参照してください。
ただし、5ページの手順4 では、PC IP アドレスは本機器と異なる値を設定して ください(下図参照。ここでは、IP アドレス 192.168.10.2、サブネット・マスク
255.255.255.0)。
CD-ROM の共有設定
1. デスクトップで マイコンピュータ をダブルクリックします。
2. CD-ROM ドライブのアイコンを選択し、マウス右ボタンをクリックします。
3. メニューから共有 (H
4. CD-ROM プロパティダイアログ・ボックスで、共有タブ内のこのフォルダを
共有するを選択し、OK をクリックします。
5. 付属の CD-ROM を共有の CD-ROM ドライブに挿入します。
)...を選択します。
インストラクション・シート
7
ソフトウェア・アップグレード
本機器と PC の接続
本機器を PC にネットワーク接続します。 本機器の Ethernet コネクタの位置を下図に示します。
Ethernet 10/100BASE-T コネクタ
前面
4Ethernet コネクタ(側面パネル)
1. LAN ケーブルを接続します。
注:マウスとキーボードは、本機器に接続したままにしておきます。
H 本機器を PC 11 で接続する場合
付属の LAN クロス・ケーブルを本機器と PC Ethernet コネクタに接続 します。
付属の LAN クロス・ケーブル
8
RSA3303B/RSA3308B/RSA3408B 型
ソフトウェア・アップグレード
H 本機器を PC LAN で接続する場合
Ethernet LAN ケーブルを本機器とネットワークに接続します。
注:本機器を LAN に接続する場合、IP アドレスなどのネットワーク設定について は、システム管理者にお問い合わせください。また、この場合には、ネットワーク の接続に付属の LAN クロス・ケーブルは使用できません。
Ethernet LANEthernet LAN ケーブル
2. 本機器の電源を入れます。
3. 本機器のアプリケーションを終了し、Windows XP デスクトップを表示します。
手順については、3ページの「Windows XP デスクトップ画面の表示」を参照 してください)。
インストラクション・シート
9
ソフトウェア・アップグレード
ソフトウェアのインストール
共有 PC を検 索して、 付属の CD-ROM から新しいソフトウェアをイ ンストール し ます。
共有 PC の検索
CD-ROM を共有する PC を検索します。
1. 本機器のデスクトップ画面で My Net wo rk Plac es アイコ ンを選択し て、マウ ス 右ボタンをクリックし、Search for Computers... を選択します。
2. Search Results Computers ダイアログ・ボックスで、Computer name: の欄に 共有 PC のコンピュータ名を入力して(ここでは “PC123”)、Search ボタンを クリックします。検索に成功すると、Name の下に PC 名が表示されます。
注:PC 名が表示されない場合には、数分後にもう一度検索を実行してください。
10
RSA3303B/RSA3308B/RSA3408B 型
ソフトウェア・アップグレード
インストール
CD-ROM からソフトウェアを読み込みます。
1. Search Results Computers ダイアログ・ボックスに表示された PC 名(ここでPc123)をダブルクリックします。
2. PC で共有しているフォルダの一覧が表示されます。 共有設定された CD-ROM ドライブをダブルクリックして、CD-ROM の内容を 表示します。
3. CD-ROM のファイル一覧から Setup.exe ファイルを選択し、ダブルクリックし ます。
セットアップが開始されます。図は、インストール開始前の準備画面です。
インストールを実行せずに終了するときは、Cancel ボタンをク リックしてくだ さい。
4. インストールが始まると、初めに下図のメッセージが現れます。 Next をクリックします。
インストラクション・シート
11
ソフトウェア・アップグレード
5. 下図のようなインストール情報が表示されます。Next をクリックします。 ファイルのコピーが開始されます。
インストール中は、下図のようなセットアップ・ステータスが表示されます。
12
6. インストールが終了すると、下図のメッセージが表示されます。
Finish をクリックします。
7. インストール終了後、表示されているすべてのウィンドウを閉じます。
8. 前面パネルの On/Standby キーを押して電源を一度切り、再度入れて本機器を
立ち上げ直してください。
RSA3303B/RSA3308B/RSA3408B 型
ソフト・キー・コードの入力
添付の SOFT KEY ラベルに記されたソフト ・キー・コードを本機器に入力して、 ソフトウェアを使用できる状態にします。
1. 前面パネルの System キーを押します。
2. Versions and Installed Options...サイド・キーを押します。
3. Option Keyサイド・キーを押し、添付の SO FT KEY ラベル に記されたソフ ト・
キー・コードを入力します。入力には、本機器に接続したキーボードまたは前面 パネルのキーパッドを使います。
注:前面パネルのキーパッドから (ハイフン)を入力するときには、“.”(ピリ オド)キーを押してください。
4. ソフト・キー・コードを入力したら、Change Option Key サイド・キーを押し、 ソフトウェアの機能を有効にします。
ソフトウェア・アップグレード
5:ソフト・キー・コードの入力
Option Key
ソフト・キー・コードを入 力します。
Change Option Key
ソフトウェアの機能を有効 にします。
H 有効な値を入力すれば、画面下側に “Valid key entered. Please restart
instrument” のメッセージが表示されます。本機器を再起動してください。
操作については、ユーザ・マニュアルを参照してください。
H 間違った値を入力すると、画面下側に “Option key: Bad Keystring” と表示
されます。ソフト・キー・コードを入力し直してください。
インストラクション・シート
13
ソフトウェア・アップグレード
ソフト・キー・ラベルと IDラベルの貼り付け
ソフトウェアのインストール作業終了後、添付の SOFT KEY ラベルと ID ラベルを 本機器の後部パネルに貼り付けてください。
RSA3303B RSA3308B
ソフト・キー・ラベル
ID ラベル
RSA3408B
ID ラベル
ソフト・キー・ラベル
6:ソフト・キー・ラベルと ID ラベルの貼り付け
以上でアップグレードは終了です。
14
RSA3303B/RSA3308B/RSA3408B 型
ソフトウェア・アップグレード
RTPA2A 型プローブ・アダプタのドライバのインストール
RTPA2A RT SA プローブ・アダプタを使用する場合は、USB ケーブルを通して プローブ・アダプタをコントロールするため、本機器に追加でデバイス・ドライバ をインストールする必要があります。
インストールの前に
H インストールを実行する際、本機器を再起動したり、電源を入れ直した りする
必要はありません。本機器のアプリケーションを終了する必要もありません。
H 本機器のメイン・システム・バージョンが 3.01.004 以上であることを確認して
ください。
H 本機器でデータ取り込み中 の場 合に は、 Run/Stop キー を押 して PA U S E 状態に
してください。Windows XP のハードウェア検出とドライバの起動がより速く なります。
H プローブ・アダプタを電源に接続します(RTPA2A 型マニュアル参照)。
ソフトウェアのインストール
1. プローブ・アダプタの USBケーブルを本機器の側面パネルの USBコネクタに 接続します(図 7)。または、キーボードの USB コネクタも使用できます。
USB コネクタ
7USB コネクタ(側面パネル)
前面
インストラクション・シート
15
ソフトウェア・アップグレード
2. 接続後、Windows XP Found New Hardware Wizard が表示されます(下図)。
3. Install from a list or specific location (Advanced)」を選択し、Next をクリック
No, not this time」を選択し、Next をクリックします。
します。
16
4. Includethislocationinthesearch」を選択し、Browse をクリックして、次の パスを表示します:C:\Program Files\Tektronix\wca200a\ProbeAdapterDriver。 Next をクリックします。
RSA3303B/RSA3308B/RSA3408B 型
ソフトウェア・アップグレード
5. インストールが始まり、次のダイアログが現れます。
6. Continue Anyway をクリックして、インストールを終了します。
7. Finish をクリックします。
インストラクション・シート
17
ソフトウェア・アップグレード
8. ドライバがインストールされたことを確認します。 a. Start Settings Control Panel Add/Remove Programs を選択します。 b. Currently Installed Programs のリストに「Tektronix RTSA Probe Adapter
USB Drivers」が示されていることを確かめます。
9. プローブ・アダプタが正しく動作していることを確認します。
RTPA2A Instruction Manual (当社部品番号:071-1766-XX) の性能確認手順を参 照してください。
18
RSA3303B/RSA3308B/RSA3408B 型
Loading...