Tektronix RSA3303B, RSA3308B, RSA3408B User manual

User Manual
RSA3303B, RSA3308B, & RSA3408B Option 24 GSM/EDGE Analysis Software
071-2398-00
This document applies to firmware version 4.0 and above.
Copyright © Tektronix. All rights reserved. Licensed software products are owned by Tektronix or its subsidiaries or suppliers, and are protected by national copyright laws and international treaty provisions.
Tektronix products are covere d by U.S. and foreign patents, issued and pending. Information in this publication supercedes that in all previously published material. Specifications and price change privileges reserved.
TEKTRONIX and TEK are registered trademarks of Tektronix, Inc.
Contacting Tektronix
Tektronix, Inc. 14200 SW Karl Braun Drive P.O. Box 500 Beaverton, OR 97077 USA
For product information, sales, service, and technical support:
H In North America, call 1-800-833-9200.
H Worldwide, visit www.tektronix.com to find contacts in your area.
Warranty 2
Tektronix warrants that thi s product will be free from defects in materials and workmanship for a period of one (1) year from the date of shipment. If any such product proves defective during this warranty period, Tektronix, at its option, either will repair the defective product without charge for parts and labor, or will provide a replacement in exchange for the defective product. Batteries are excluded from this warranty. Parts, modules and replacement products used by Tektronix for warranty work may be new or reconditioned to like new performance. All replaced parts, modules and products become the property of Tektronix.
In order to obtain service under this warranty, Customer must notify Tektronix of the defect before the expiration of the warranty period and make suitable arrangements for the performance of service. Customer shall be responsible for packaging and shipping the defective product to the service center designated by Tektronix, shipping charges prepaid, and with a copy of customer proof of purchase. Tektronix shall pay for the return of the product to Customer if the shipment is to a location within the country in which the Tektronix service c enter is located. Customer shall be responsible for paying all shipping charges, duties, taxes, and any other charges for products returned to any other locations
This warranty shall not apply to any defect, failure or damage caused by improper use or improper or inadequate maintenance and care. Tektronix shall not be obligated to furnish service under this warranty a) to repair damage resulting from attempts by personnel other than Tektronix representatives to install, repair or service the product; b) to repair damage resulting from improper use or connection to incompatible equipment; c) to repair any damage or malfunction caused by the use of non--Tektronix supplies; or d) to service a product that has been modified or integrated with other products when the effect of such modification or integration increases the time or difficulty of servicing the product.
THIS WARRANTY IS GIVEN BY TEKTRONIX WITH RESPECT TO THE PRODUCT IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED. TEKTRONIX AND ITS VENDORS DISCLAIM ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PAR TICULAR PURPOSE. TEKTRONIX EXCLUSIVE REMEDY PROVIDED TO THE CUSTOMER FOR BREACH OF THIS WARRANTY. TEKTRONIX AND ITS VENDORS WILL NOT BE LIABLE FOR ANY INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES IRRESPECTIVE OF WHETHER TEKTRONIX OR THE VENDOR HAS ADVANCE NOTICE OF THE POSSIBILITY OF SUCH DAMAGES
ٛF RESPONSIBILITY TO REPAIR OR REPLACE DEFECTIVE PRODUCTS IS THE SOLE AND

Table of Contents

Getting Started
Operating Basics
Preface v...................................................
About This Manual v...............................................
Related Documents vi...............................................
Definition of the GSM/EDGE Analysis 1--2...............................
Channel Frequencies 1--2.............................................
Measurement Functions 1--3...........................................
Measurement Menu 1--8..............................................
Burst Analysis 2--1............................................
Measurement Procedure 2--1...........................................
Meas Setup Menu 2--4................................................
Modulation Accuracy Measurement 2--6.................................
Mean Carrier Power Measurement 2--7...................................
Power versus Time Measurement 2--8...................................
Modulation Spectrum Measurement 2--9.................................
Switching Spectrum Measurement 2 --10...................................
Spurious Analysis 2--11.........................................
Measurement Procudure 2--11...........................................
Meas Setup Menu 2--12................................................
Measurement Example 2--13............................................
Scale and Format of View 2--15...................................
Constellation View 2--16...............................................
EVM View 2--18.....................................................
Power versus Time View 2--20..........................................
Appendices
Appendix A: Scale Setting Range A--1............................
Index
RSA3303B, RSA3308B, & RSA3408B Option 24 User Manual
i
Table of Contents

List of Figures

Figure 1--1: An example of the GSM/EDGE analysis display 1--1......
Figure 1--2: Slot data structure 1--3...............................
Figure 1--3: GSM/EDGE standard masks for Power versus Time
measurement 1--4..........................................
Figure 1--4: GSM/EDGE measurement menu 1--8...................
Figure 2--1: Setting analysis range on the overview 2--2..............
Figure 2--2: Modulation accuracy measurement 2--6................
Figure 2--3: Mean carrier power measurement 2--7..................
Figure 2--4: Power versus Time measurement 2--8..................
Figure 2--5: Modulation spectrum measurement 2--9................
Figure 2--6: Switching spectrum measurement 2--10..................
Figure 2--7: Spurious measurement 2--13...........................
Figure 2--8: Vector and Constellation display 2--16...................
Figure 2--9: EVM, amplitude error, and phase error display 2--18......
Figure 2--10: Expanding a burst 2--20..............................
ii
RSA3303B, RSA3308B, & RSA3408B Option 24 User Manual

List of Tables

Table of Contents
Table 1--1: Additional functions in Option 24 1--1..................
Table 1--2: Channel Frequencies 1--2.............................
Table 1--3: Measurement items 1--3..............................
Table 1--4: Modulation spectrum standard masks 1 1--5............
Table 1--5: Switching spectrum standard masks 1 1--6..............
Table 1--6: Spurious measurement conditions 1--7..................
Tabl e A--1: Display format and scale A--1.........................
RSA3303B, RSA3308B, & RSA3408B Option 24 User Manual
iii
Table of Contents
iv
RSA3303B, RSA3308B, & RSA3408B Option 24 User Manual

Preface

About This Manual

This manual describes how to use the RSA3303B, RSA3308B, and RSA3408B Option 24 GSM/EDGE Analysis Software.
This manual supports the following instruments:
H RSA3303B Option 24
H RSA3308B Option 24
H RSA3408B Option 24
The manual consists of the following sections:
H Getting Started describes t he overview of the GSM/EDGE analysis.
H Operating Basics explains the menu functions and measurement procedures.
H Appendices provide additional information about scale setting ranges.
The analyzer uses Microsoft Windows XP as the operating system. This manual does not describe common usage of Windows XP. Refer to your Windows manuals as necessary .
RSA3303B, RSA3308B, & RSA3408B Option 24 User Manual
v
Preface

Related Documents

The following documents are also available for the analyzer:
H RSA3303B & RSA3308B User Manual
(Standard accessory; Tektronix part number 071-2363-XX)
RSA3408B User Manual
(Standard accessory; Tektronix part number 071-2364-XX) Describes how to install the analyzer and how to work with the menus, and details the standard functions.
H RSA3000B Series Programmer Manual
(Standard accessory; PDF, Tektronix part number 071-2382-XX) Contains an alphabetical listing of the programming commands and other information related to controlling the analyzer over the GPIB interface.
PDF Manual
The RSA3000B Series Programmer Manual (PDF only) is included in the Documents CD (Tektronix part number 063-4089-XX).
vi
RSA3303B, RSA3308B, & RSA3408B Option 24 User Manual
Getting Started

Getting Started

This section outlines the modulation analysis according to the GSM/EDGE standard using the RSA3303B, RSA3308B, and RSA3408B Option 24. Table 1--1 summarizes the additional functions in Option 24 by measurement mode.
Table 1- 1: Additional functions in Option 24
Measurement mode Additional functions
S/A (spectrum analysis) None
Demod (modulation analysis) Six measurement functions under the GSM/EDGE standard
Time (time analysis) None
Figure 1--1 shows an example of the GSM/EDGE analysis.
Figure 1- 1: An example of the GSM/EDGE analysis display
RSA3303B, RSA3308B, & RSA3408B Option 24 User Manual
1- 1
Getting Started

Definition of the GSM/EDGE Analysis

The analyzer performs GSM/EDGE analysis that conforms to the 3GPP TS45.005 V4.1.0.5 standard.

Channel Frequencies

The analyzer includes GSM/EDGE channel tables as shown in Table 1--2:
Table 1- 2: Channel Frequencies
Channel
Standard Link
GSM850 Uplink 128 to 251 824.2 to 848.8 0.2 (N -- 128) + 824.2
Downlink 128 to 251 869.2 to 893.8 0.2 (N -- 128) + 869.2
GSM900 Uplink 0to124 890 to 914.8 0.2N + 890
Downlink 0to124 935 to 959.8 0.2N + 935
DCS1800 Uplink 512 to 885 1710.2 to 1784.8 0.2 (N -- 512) + 1710.2
Downlink 512 to 885 1805.2 to 1879.8 0.2 (N --512) + 1805.2
PCS1900 Uplink 512 to 810 1850.2 to 1908.8 0.2 (N -- 512) + 1850.2
Downlink 512 to 810 1930.2 to 1989.8 0.2 (N -- 512) + 1930.2
(N)
975 to 1023 880.2 to 889.8 0.2 (N -- 1024) + 890
975 to 1023 925.2 to 934.8 0.2 (N -- 1024) + 935
Frequency range (MHz)
Frequency calculation formula (MHz)
1- 2
RSA3303B, RSA3308B, & RSA3408B Option 24 User Manual

Measurement Functions

The analyzer provides six GSM/EDGE measurement functions as shown in Table 1--3:
Table 1- 3: Measurement items
Measurement item Standard
Modulation accuracy GSM 11.20 -- 2.1.6.2
Mean carrier power GSM 11.20 -- 2.1.6.3
Power versus Time GSM 11.20 -- 2.1.6.4
Modulation spectrum GSM 11.20 -- 2.1.6.5.1
Switching spectrum GSM 11.20 -- 2.1.6.5.2
Spurious signals within transmis­sion band
GSM 5.05 v.8.5.0/4.3.3
Getting Started
Modulation Accuracy
Mean Carrier Power
The analyzer measures EVM (Error Vector Magnitude), amplitude error, and phase error in accordance with the GSM standard 11.20 -- 2.1.6.2.
The analyzer uses the 147 symbols located at the center of a specified burst to measure EVM, amplitude error, phase error, waveform quality (ρ), frequency error, and origin offset. (“Origin offset” is also called “IQ feedthrough.”)
The analyzer measures mean carrier power in accordance with the GSM standard
11.20 -- 2.1.6.3.
Figure 1--2 illustrates the data structure of a slot. The analyzer measures power in the interval E (Data 2) located after TS (Training Sequence) for each burst to calculate the mean value of the power within the measurement range.
T (#H0) G (#HFF)
T (#H0)
E
(Data 1)
58
3
TS
(#H0970897)
26
E
(Data 2)
58
3bit
8.25
Figure 1- 2: Slot data structure
RSA3303B, RSA3308B, & RSA3408B Option 24 User Manual
1- 3
Getting Started
Power versus Time
[dB]
+4
+1
0
-- 1
-- 6
-- 3 0
*1
10 8 10 542.8 10 8 10 [ms]
The analyzer measures Power versus Time in accordance with the GSM standard
11.20 -- 2.1.6.4.
The analyzer demodulates a specified burst and synchronizes with the TS (Training Sequence). The analyzer uses the comparison between the spectrum and the GSM/EDGE standard mask (see Figure 1--3), to determine the Pass/Fail status of the test.
GMSK (GSM850/900, DCS1800)
[dB]
+4
+1
0
-- 1
-- 6
-- 3 0
*1
10 8 10 542.8 10 8 10 [ms]
GMSK (PCS1900)
[dB]
+4
+2.4
+1
-- 1 5
-- 3 0
0
-- 1
-- 6
*1
10 8 10 542.8 10 8 10 [ms]
2222
EDGE
*1. --59 dBc or --54 dBm (whichever is higher)
for GSM850/900 uplink bands
--48 dBc or --48 dBm (whichever is higher) for DCS1800 and PCS1900 uplink bands
--30 dBc for all downlink bands
Figure 1- 3: GSM/EDGE standard masks for Power versus Time measurement
1- 4
RSA3303B, RSA3308B, & RSA3408B Option 24 User Manual
Getting Started
Modulation Spectrum
The analyzer measures the spectrum generated by the modulation process in accordance with the GSM standard 11.20 -- 2.1.6.5.1.
The analyzer acquires the input signal with a span of 15 MHz and demodulates a single burst. The spectrum of the burst is calculated from the center of the training sequence over an interval of 320 ms. This spectrum is calculated using a 30 kHz RBW up to 1.8 MHz from t he carrier, and 100 kHz RBW from 1.8 to 6 MHz from the carrier. Finally, the analyzer compares the spectrum and GSM/EDGE standard masks (see Table 1--4 below) to determine pass/fail status of testing.
-- 5 4
-- 5 4
1
1.8<3≥3
<1.8
-- 6 0 -- 6 3 -- 6 5 -- 7 1
1.8<3≥3
<1.8
-- 7 0 -- 7 3 -- 7 5 -- 8 0
<6
<6
6
6
Table 1- 4: Modulation spectrum standard masks
GSM850/900 uplink
Offset (MHz) 0.1 0.2 0.25 0.4 0.6
Level (dBc) +0.5 -- 3 0 -- 3 3 -- 6 0
GSM850/900 downlink
Offset (MHz) 0.1 0.2 0.25 0.4 0.6
Level (dBc) +0.5 -- 3 0 -- 3 3 -- 6 0
DCS1800 uplink
Offset (MHz) 0.1 0.2 0.25 0.4 0.6
<1.8
Level (dBc) +0.5 -- 3 0 -- 3 3 -- 6 0
-- 5 4
DCS1800 downlink
Offset (MHz) 0.1 0.2 0.25 0.4 0.6
Level (dBc) +0.5 -- 3 0 -- 3 3 -- 6 0
-- 5 6
1
The levels are common for GMSK and EDGE. In cases where two values are indicated in a single column, however, values in the upper line are for GMSK and values in the lower line are for EDGE.
-- 6 0 -- 5 9 -- 6 7
<1.2
-- 7 0 -- 7 3 -- 7 5 -- 8 0
1.8<6≥6
1.2
<1.8
1.8<6≥6
RSA3303B, RSA3308B, & RSA3408B Option 24 User Manual
1- 5
Getting Started
Table 1- 4: Modulation spectrum standard masks
PCS1900 uplink
Offset (MHz) 0.1 0.2 0.25 0.4 0.6
1
(Cont.)
<1.2
1.2 <1.8
1.8<6≥6
Switching Spectrum
Level (dBc) +0.5 -- 3 0 -- 3 3 -- 6 0
-- 5 4
PCS1900 downlink
Offset (MHz) 0.1 0.2 0.25 0.4 0.6
Level (dBc) +0.5 -- 3 0 -- 3 3 -- 6 0
-- 5 6
-- 6 0 -- 6 0 -- 5 9 -- 6 7
1.2
<1.2
-- 7 0 -- 7 3 -- 7 5 -- 8 0
<1.8
1.8<6≥6
The analyzer measures the spectrum due to switching transients in accordance with the GSM standard 11.20 -- 2.1.6.5.2.
The analyzer acquires the input signal with a span of 5 MHz, and calculates the spectrum using a 30 kHz RBW conversion. The analyzer uses peak hold for multiple bursts, and compares the spectrum with GSM/EDGE masks (see Table 1--5) to determine pass/fail status of the test.
Table 1- 5: Switching spectrum standard masks
GSM850/900, DCS1800, and PCS1900 uplink
Offset (MHz) 0.4 0.6 1.2 1.8
1
1- 6
Level (dBc) -- 2 3 -- 2 6 -- 3 2 -- 3 6
GSM850/900 downlink
Offset (MHz) 0.4 0.6 1.2 1.8
Level (dBc) -- 5 7 / -- 5 2 -- 6 7 / -- 6 2 -- 7 4 -- 7 4
DCS1800 and PCS1900 downlink
Offset (MHz) 0.4 0.6 1.2 1.8
Level (dBc) -- 5 0 -- 5 8 -- 6 6 -- 6 6
1
The levels are common for GMSK and EDGE. In cases where two values are indicated in a single column, however, the values to the left are for GMSK and the values to the right are for EDGE.
RSA3303B, RSA3308B, & RSA3408B Option 24 User Manual
Getting Started
f
f
)
30kHz(Offse
t≥1.8MHz)
d
B
Inband Spurious Signals
The analyzer detects the spurious signals existing within the transmission band in accordance with the GSM standard 5.05 version 8.5.0/4.3.3.
The analyzer calculates the spectrum of the input signal, using the correct R BW for the frequency offset from the carrier, as shown i n Table 1--6. The largest peak in the specified transmission band is assumed to be the carrier and all other peaks are assumed to be spurious responses.
Table 1- 6: Spurious measurement conditions
Standard Transmission band RBW Threshold
GSM850 824 to 849 MHz (Uplink)
869 to 894 MHz (Downlink)
GSM900 876 to 915 MHz (Uplink)
921 to 960 MHz (Downlink)
DCS1800 1710 to 1785 MHz (Uplink)
1805 to 1880 MHz (Downlink)
PCS1900 1850 to 1910 MHz (Uplink)
1930 to 1960 MHz (Downlink)
1
User-definable
30 kHz(O 100 kHz (Offset 6MHz)
set 1.8 MHz
-- 3 6
1
m
RSA3303B, RSA3308B, & RSA3408B Option 24 User Manual
1- 7
Getting Started

Measurement Menu

Figure 1--4 shows the measurement menu items added in Option 24.
Standard... G SM/EDGE Modulation Accuracy
Mean Carrier Power Power versus Time Modulation Spectrum Switching Spectrum Inband Spurious
Figure 1- 4: GSM/EDGE measurement menu
The following sections provide the measurement procedures.
1- 8
RSA3303B, RSA3308B, & RSA3408B Option 24 User Manual
Operating Basics

Burst Analysis

The following five measurements can be performed on one or more GSM/EDGE bursts:
H Modulation accuracy
H Mean carrier power
H Power versus time
H Modulation spectrum
H Switching spectrum
The burst analysis is based on the digital modulation analysis function. For the digital modulation analysis, refer to your instrument user manual.
For the spurious signal analysis, refer to page 2--11.

Measurement Procedure

Use the following steps to perform the burst analysis:
1. Select the measurement:
a. Press the Demod key on the front panel.
b. Press the Standard... side key and then the GSM/EDGE side key.
c. Press one of the following side keys to select the measurement:
Modulation Accuracy Mean Carrier Power Power vs. Time Modulation Spectrum Switching Spectrum
2. Acquire the waveform of signal to be measured:
NOTE. When the input signal is not according to the GSM/EDGE standard, no measurement result may be displayed. However , the waveform of the signal will still be displayed in the overview.
a. Press the Frequency/Channel key on t he front panel to set center
frequency.
RSA3303B, RSA3308B, & RSA3408B Option 24 User Manual
2- 1
Burst Analysis
A
How to use the channel table:
H Press Channel Table... side key.
H Select one of the GSM/EDGE standards.
H Use Channel side key to select a channel.
b. Press the Span key on the front panel to s et span. R ange: 1 to 15 MHz
NOTE. It is important to set the span as narrow as possible for the selected modulation type, and to adjust the reference level carefully. Setting these parameters incorrectly can result in incorrect recognition of the signal’s modulation type.
c. Press the Amplitude key on the front panel to set up the amplitude of
the signal near the full scale in the overview.
d. Press the Trig key on the front panel to set up the trigger as necessary.
e. Press the Acquisition/Analysis key on the front panel, and then press
the Acquisition Length side key t o set the number of slots for one acquisition block (see Figure 2--1). Default: 18 slots.
f. After you have acquired the measurement data, you can stop the
acquisition using the Run/Stop key.
cquisition History (Block number)
Overview
The burst specified with the Burst Select side key selects the burst to be analyzed. The area between two vertical green lines indicates the analysis range. The result of analysis is displayed in the main view.
The area between two vertical pink lines indicates the range of the FFT process, that is one FFT frame, to display the spectrum in the subview.
Acquisition Length
(Time length to acquire one block)
Figure 2- 1: Setting analysis range on the overview
2- 2
RSA3303B, RSA3308B, & RSA3408B Option 24 User Manual
Burst Analysis
3. From the overview, select the burst to be analyzed (see Figure 2-- 1).
a. Press the Acquisition/Analysis key on the front panel.
b. If you acquired the signal in continuous trigger repeat:
Press the Acquisition History side key to specify the block number to be analyzed. Block number “0” corresponds to the latest block.
c. Press the Burst Select side key to specify the burst number to be
analyzed. Burst number “0” corresponds to the latest burst.
How to return to the first burst:
To select the first burst of all the data that has been acquired in memory, press the Return to First Burst side key.
NOTE. In GSM/EDGE, the analysis length must be at least 1.28 ms.
The specified burst is analyzed and the result of the analysis is displayed on the screen.
4. Press the Meas Setup key and change the measurement conditions as necessary.
For the Meas Setup menu, refer to page 2--4.
5. To analyze waveform data that has been acquired in memory, do the following steps:
a. Press the Acquisition/Analysis key on the front panel.
b. If you acquired the signal in continuous trigger repeat:
Press the Acquisition History side key to specify the block number to be analyzed.
c. Press the Burst Select side key to specify the burst number to be
analyzed.
How to return to the first burst:
To select the first burst of all the data that has been acquired in memory, press the Return to First Burst side key.
d. Press the Meas Setup key on the front panel and then press the Analyze
from Selected Burst side key.
The analyzer performs analysis from the burst specified in step c to the end of the waveform data. To interrupt the analysis, press the Cancel-Back (top) side key.
RSA3303B, RSA3308B, & RSA3408B Option 24 User Manual
2- 3
Burst Analysis

Meas Setup Menu

The Meas Setup menu items for the burst analysis are as follows:
Modulation Type. Selects the modulation type.
H GMSK. Default. Selects GMSK (Gaussian filtered Minimum Shift Keying).
H EDGE. Selects EDGE (Enhanced Data rate for GSM Evolution).
Standard... Selects specification of the mask for comparison with the spectrum waveform:
H GSM850-UL
H GSM850-DL
H GSM900-UL
H GSM900-DL
H DCS1800-UL
H DCS1800-DL
H PCS1900-UL
H PCS1900-DL
UL and DL mean uplink and downlink, respectively.
This menu item is unavailable in the mean carrier power measurement.
Burst Select. Sets the burst number to be analyzed. This menu item is the same as the Burst Index parameter in the Acquisition/Analysis menu. Burst number “0” corresponds to the latest burst. The larger the negative values, the older the bursts.
Return to First Burst. Selects the first burst of all the data that has been acquired in memory. This menu item is invalid during acquisition of an input signal.
Analyze from Selected Burst. Press this key for repeated analysis of waveform data that has previously been acquired in memory. The analysis is done from the selected burst. This menu item is invalid during acquisition of an input signal.
2- 4
RSA3303B, RSA3308B, & RSA3408B Option 24 User Manual
Burst Analysis
TS Code Filtering. Determines whether to perform the analysis while specifying Training Sequence (TS), or not.
H Off. Default. No training sequence is specified. The analyzer will perform
the analysis for all the training sequences.
H 0 to 7. Sets the training sequence code number to be analyzed. The analysis
result is displayed in the main view only for the bursts containing the specified training sequence, and only results from bursts containing the specified training sequence are included in averaged results.
This menu item is unavailable in the switching spectrum measurement.
Analyze Includes. Sets the number of symbols for EVM calculation in the modulation accuracy measurement.
H 142. Measures 142 symbols excluding the tail bits for the EDGE signal.
H 147. Measures 147 symbols specified for the GMSK signal.
H 148. Measures all symbols in a burst.
Midpoint shift. Defines the center of the mask in the power versus time measure­ment.
H Off. Positions the center of the mask halfway between symbol 13 and 14 in
the training sequence.
H On. Aligns the center of the mask with symbol 14 in the training sequence.
Auto Carrier. Determines whether to activate the automatic carrier detection.
H On. Default. The carrier is automatically detected during data analysis.
H Off. No detection of carrier frequency is performed. Set the carrier frequency
offset in Frequency Offset.
This menu item is unavailable in the switching spectrum measurement.
Frequency Offset. When Off is selected in Auto Carrier above, it is necessary to set the carrier frequency offset with reference to the center frequency.
This setup item is unavailable in the switching spectrum measurement.
RSA3303B, RSA3308B, & RSA3408B Option 24 User Manual
2- 5
Burst Analysis

Modulation Accuracy Measurement

Figure 2--2 shows an example of the modulation accuracy measurement.
H Overview: Power versus Time for the specified block
H Subview: Constellation for the specified burst
H Main view: Measurement results and EVM view
Pass/Fail status
Measurement results
H EVM (RMS/Peak/95 H Amplitude error (RMS/Peak) H Phase error (RMS/Peak) H Frequency error H Origin offset (IQ feedthrough) H Training sequence code
The pass/fail test item is displayed in green when passed or in red when failed.
th
percentile)
Figure 2- 2: Modulation accuracy measurement
Changing Views. You can change the presentation of the overview, the subview,
and the main view. P rocedures to change the presentation of the overview or the subview are common with those for the modulation analysis. Refer to your instrument user manual.
To change the presentation of the main view, proceed as follows:
2- 6
1. Press the View: Define key on the front panel.
2. Press the Mainview Content... side key and select the main view content:
H Constellation
H EVM (Error Vector Magnitude)
RSA3303B, RSA3308B, & RSA3408B Option 24 User Manual

Mean Carrier Power Measurement

Figure 2--3 shows an example of the mean carrier power measurement.
H Overview: Power versus Time for the specified block
H Subview: Constellation for the specified burst
H Main view: Power versus Time for the specified burst
The blue domain in the Power versus Time display on the right of the main view shows the range of calculation process. The mean power, maximum power, and minimum power are indicated on the left of the main view for each burst.
Burst Analysis
Burst number
Training sequence code
Measurement results: Mean power
Figure 2- 3: Mean carrier power measurement
Changing Views. You can change the presentation of the overview and the
subview. The procedures to change the presentation of the overview and the subview are common with those of the modulation analysis. Refer to your instrument user manual.
RSA3303B, RSA3308B, & RSA3408B Option 24 User Manual
Blue domain indicates the range of calculation
2- 7
Burst Analysis

Power versus Time Measurement

Figure 2--4 shows an example of the power versus time measurement.
H Overview: Power versus Time for the specified block
H Subview: Constellation for the specified burst
H Main view: Measurement results and the mask for the specified burst
The Power versus Time waveform and the GSM/EDGE standard mask are shown on the right of the main view. The mean power as well as Pass/Fail status of testing are shown on the left of the main view for each burst.
Pass/Fail status
2- 8
Burst number
Training sequence code
Measurement results
H Mean power H Pass/Fail
GSM/EDGE standard mask
Figure 2- 4: Power versus Time measurement
Changing Views. You can change the presentation of the overview and the
subview. The procedures to change the presentation of the overview and the subview are common with those of the modulation analysis. Refer to your instrument user manual.
RSA3303B, RSA3308B, & RSA3408B Option 24 User Manual

Modulation Spectrum Measurement

Figure 2--5 shows an example of the modulation spectrum measurement.
H Overview: Power versus Time for the specified block
H Subview: Constellation for the specified burst
H Main view: Spectrum and the mask for the specified burst
The spectrum waveform and the GSM/EDGE specification mask are displayed in the main view. To select the mask specification, use the Standard... side key in the Meas Setup menu.
Burst Analysis
Pass/Fail status
Standard...
Select a mask specification.
The mask selected with the Standard... side key
Figure 2- 5: Modulation spectrum measurement
Changing Views. You can change the presentation of the overview and the
subview. The procedures to change the presentation of the overview and the subview are common with those of the modulation analysis. Refer to your instrument user manual.
RSA3303B, RSA3308B, & RSA3408B Option 24 User Manual
2- 9
Burst Analysis

Switching Spectrum Measurement

Figure 2--6 shows an example of the switching spectrum measurement.
H Overview: Power versus Time for the specified block
H Subview: Constellation for the specified burst
H Main view: Spectrum and the mask for the specified burst
The spectrum waveform and the GSM/EDGE specification mask are shown in the main view. To select the mask specification, use the Standard... side key in the Meas Setup menu.
Pass/Fail status
Standard...
Select a mask specification.
Figure 2- 6: Switching spectrum measurement
Changing Views. You can change the presentation of the overview. The procedure
to change the presentation of the overview is common with that of the modula­tion analysis. Refer to your instrument user manual for the details.
2- 10
The mask selected with the Standard... side key
RSA3303B, RSA3308B, & RSA3408B Option 24 User Manual

Spurious Analysis

This section describes operating basics for the measurement of spurious signals within a transmission band. The spurious signal measurement in GSM/EDGE is based on that function in the normal spectrum analysis. For the basics, refer to Spurious Signal Measurement in your instrument user manual.

Measurement Procedure

The following is the fundamental procedure for the spurious signal measurement.
1. Press the Demod key on the front panel.
2. Press the side key GSM/EDGE Inband Spurious.
3. Display the spectrum waveform of the measurement signal:
NOTE. For details on setting frequency, span, and amplitude, refer to your instrument user manual.
a. Press the Run/Stop key on the front panel to start data acquisition.
b. Set the frequency by pressing the Frequency/Channel key on the front
panel.
How to use the channel table:
H Press the Channel Table... side key.
H Select one of the GSM/EDGE standards.
H Use the Channel side key to select a channel.
c. Set the span by pressing the Span key on the front panel.
d. Set the amplitude by pressing the Amplitude key on the front panel.
4. Set the following measurement setup controls by pressing the Meas Setup key on the front panel.
RSA3303B, RSA3308B, & RSA3408B Option 24 User Manual
2- 11
Spurious Analysis

Meas Setup Menu

The Meas Setup menu for the spurious signal measurement contains the following controls:
Standard... Selects a specification of t he mask for comparison with the spectrum waveform:
H GSM850-UL
H GSM850-DL
H GSM900-UL
H GSM900-DL
H DCS1800-UL
H DCS1800-DL
H PCS1900-UL
H PCS1900-DL
UL and DL mean uplink and downlink, respectively.
Signal Threshold. Sets the threshold for detecting the carrier. A signal with the amplitude larger than this threshold is regarded as a carrier . Range: --100 to +30 dBm (default: --20 dBm)
Spurious Threshold. Sets the threshold for detecting spurious signals. A signal with the amplitude larger than this threshold is regarded as a spurious signal. Range: --150 to 0 dBm (default: --36 dBm)
Scroll Table. Horizontally scrolls the spurious table displayed in the lower part of the screen. Up to 10 spurious signals are displayed.
2- 12
RSA3303B, RSA3308B, & RSA3408B Option 24 User Manual

Measurement Example

Pass/Fail status of testing
Signal Threshold:
A signal with larger amplitude than this
level is regarded as a standard signal.
Spurious Analysis
Figure 2--7 shows an example of the spurious measurement. The analyzer compares the spectrum waveform with the standard mask to extract 10 peaks that exceeded the spurious threshold in ascending order. Detected spurious signals are assigned markers, numbered in descending order by amplitude. The frequency and the amplitude are shown in the table at the bottom of the screen.
Spurious marker
Spurious Threshold:
A signal with larger amplitude than this
level is regarded as a spurious signal.
Measurement results (10 spurious points)
H Frequency H Amplitude
Figure 2- 7: Spurious measurement
The region within (carrier frequency) ±1.6 MHz is
out of test range in the spurious measurement.
RSA3303B, RSA3308B, & RSA3408B Option 24 User Manual
2- 13
Spurious Analysis
2- 14
RSA3303B, RSA3308B, & RSA3408B Option 24 User Manual

Scale and Format of View

Setup procedures for the scale and format of views in the GSM/EDGE analysis are the same with those in other measurement modes, except the following views:
H Constellation view
H EVM view
H Power versus Time view (for the Power versus Time measurement only)
This section describes the Scale menus for these three views. For details on setup procedures for the other views, refer to Scale and Format of Views in your instrument user manual.
RSA3303B, RSA3308B, & RSA3408B Option 24 User Manual
2- 15
Scale and Format of View

Constellation View

The Scale menu for the constellation view in the GSM/EDGE analysis has the following controls:
Measurement Content. Select vector or constellation display.
H Vector. Selects the vector display. The phase and amplitude of the input
signal are displayed in a two-dimensional IQ diagram. The red points indicate the symbol positions of the measured signal, and the yellow trace indicates the IQ trajectory between symbols.
H Constellation. Selects the constellation display. It is basically the same as
the vector display, except that symbols of the measured signal are indicated in red, and the IQ trajectory between the symbols is not shown. The cross marks (+) indicate symbol positions of ideal signal.
Vector display Constellation display
Figure 2- 8: Vector and Constellation display
EDGE Inverse Filter. Determines whether to apply the inverse filter to the received
data for displaying the waveform of an EDGE signal.
H Off. Displays the waveform without applying the inverse filter to the
received data.
H On. Default. Displays the waveform while applying the inverse filter to the
received data.
This menu item is invalid for a GMSK signal. It is available when you select EDGE with Modulation Type in the Meas Setup menu.
2- 16
RSA3303B, RSA3308B, & RSA3408B Option 24 User Manual
Scale and Format of View
Slice Timing. Selects the positions on which the red points are to be located.
H 0. Default for GMSK. The red points are located at the ideal symbol
positions.
H 0.5. Default for EDGE. The red points are located at positions halfway
between the ideal symbols.
For the EDGE modulation analysis, this menu item is available when you select Off with EDGE Inverse Filter above.
RSA3303B, RSA3308B, & RSA3408B Option 24 User Manual
2- 17
Scale and Format of View

EVM View

The Scale menu for the EVM view in the GSM/EDGE analysis has the following controls:
Measurement Content.... Selects one of the following formats for view (see
Figure 2--9).
H EVM. Default. Displays the temporal response of EVM (Error Vector
Magnitude) versus time.
H Mag Error. Displays the amplitude error versus time.
H Phase Error. Displays the phase error versus time.
EVM display Magnitude error display Phase error display
Figure 2- 9: EVM, amplitude error, and phase error display
EVM Bandpass Filter. Turns on or off the Raised Cosine Windowed Raised
Cosine filter. The default setting is On according to the GSM/EDGE standard.
Auto Scale. Executes the auto scale function. When auto scale is activated, the starting value and the scale of the vertical axis are automatically set so that the waveform will be displayed for optimal viewing.
2- 18
RSA3303B, RSA3308B, & RSA3408B Option 24 User Manual
Scale and Format of View
Horizontal Scale. Sets the scale of t he horizontal axis.
Horizontal Start. Sets the starting value of the horizontal axis.
Vertical Scale. Sets the of the scale of the vertical axis.
Vertical Stop. Sets the maximum value (top edge) of the vertical axis.
Full Scale. Sets the scale of the vertical axis to the default full-scale value.
RSA3303B, RSA3308B, & RSA3408B Option 24 User Manual
2- 19
Scale and Format of View

Power versus Time View

The Scale menu for the power versus time display on the main view in the Power versus Time measurement has the following controls:
View Full Burst. Displays the entire burst (see Figure 2--10).
View Rising Edge. Expands the rising edge horizontally (see Figure 2--10).
View Falling Edge. Expands the falling edge horizontally (see Figure 2--10).
View Full Burst View Rising Edge View Falling Edge
Figure 2- 10: Expanding a burst
Auto Scale. Sets the start value and scale of the vertical axis to automatically
display the entire waveform.
Horizontal Scale. Sets the scale of t he horizontal axis.
Horizontal Start. Sets the minimum value (left edge) of the horizontal axis.
Vertical Scale. Sets the scale of the vertical axis.
Vertical Stop. Sets the maximum value (top edge) of the vertical axis.
Full Scale. Sets the scale and start value of the vertical axis to the default
full-scale value.
2- 20
RSA3303B, RSA3308B, & RSA3408B Option 24 User Manual
Appendices

Appendix A: Scale Setting Range

This section lists the setting ranges of the horizontal and the vertical scales for the views used in the GSM/EDGE analysis.
Table A- 1: Display format and scale
Display format Horizontal range Vertical range
Spectrum 0Hzto8GHz --200 to +100 dBm
Spectrogram 0Hzto8GHz Frame --15999 to 0
Time domain view -- ( Tf× Nf)to0s* --200 to +100 dBm (Amplitude)
Constellation -- ( Tf× Nf)to0s* fixed
EVM -- ( Tf× Nf)to0s* --100 to +200% (EVM)
Frame --63999 to 0 (Option 02)
-- 3 0 t o + 3 0 V (I/Q level)
--300 to +300% (AM)
--38.4 to +38.4 MHz (FM/FVT)
--675 to +675 degrees (PM)
--300 to +300% (amplitude error)
--675 to +675 degrees (phase error)
Eye diagram -- ( Tf× Nf)to0s* fixed
Symbol table 0 to (1024 × Nf) symbols NA
*Tf: Frame time; Nf: Frame number
RSA3303B, RSA3308B, & RSA3408B Option 24 User Manual
A-1
Scale Setting Range
A-2
RSA3303B, RSA3308B, & RSA3408B Option 24 User Manual
Index

Index

A
Additional functions in Option 24, 1--1
B
Burst analysis, 2--1
mean carrier power, 2-- 7 Meas Setup menu, 2--4 measurement procedure, 2--1 modulation accuracy, 2--6 modulation spectrum, 2--9 power versus time, 2--8 switching spectrum, 2--10
C
Constellation, Scale menu, 2--16 Conventions, vi
D
Definition of the GSM/EDGE analysis, 1--2 Documentation list, vi
PDF , vi
E
M
Manuals list, vi
PDF , vi Mean carrier power, burst analysis, 2--7 Meas Setup menu
burst analysis, 2--4
spurious analysis, 2--12 Measurement procedure
burst analysis, 2--1
spurious analysis, 2--11 Modulation accuracy, burst analysis, 2--6 Modulation spectrum, burst analysis, 2--9
P
PDF manual, vi Power versus Time
burst analysis, 2--8
Scale menu, 2-- 20
S
Setting, range of scale, A--1 Spurious analysis, 2--11
Meas Setup menu, 2--12
measurement procedure, 2--11 Switching spectrum, burst analysis, 2--10
EVM, Scale menu, 2--18
G
GSM/EDGE analysis, definition, 1--2
RSA3303B, RSA3308B, & RSA3408B Option 24 User Manual
V
View, 2- -15
constellation, 2--16
EVM, 2--18
Power versus Time, 2--20
Index- 1
Index
Index- 2
RSA3303B, RSA3308B, & RSA3408B Option 24 User Manual
Loading...